diff options
author | dc42 <dcrocker@eschertech.com> | 2020-03-11 11:13:55 +0300 |
---|---|---|
committer | GitHub <noreply@github.com> | 2020-03-11 11:13:55 +0300 |
commit | f2e287b9fac6769389b01b70c8db90f4692ba3a1 (patch) | |
tree | a65ab21129e6d5a93fc80a05440b68fc817ffbbf /WHATS_NEW_RRF3.md | |
parent | 2fddbaa00a2ca3211cd38b419fc839c9c0b65439 (diff) |
Update WHATS_NEW_RRF3.md
Diffstat (limited to 'WHATS_NEW_RRF3.md')
-rw-r--r-- | WHATS_NEW_RRF3.md | 3 |
1 files changed, 2 insertions, 1 deletions
diff --git a/WHATS_NEW_RRF3.md b/WHATS_NEW_RRF3.md index 6f145e79..16049736 100644 --- a/WHATS_NEW_RRF3.md +++ b/WHATS_NEW_RRF3.md @@ -15,7 +15,7 @@ New features/changed behaviour: - Round brackets in GCode lines are no longer treated as enclosing comments if the machine is not in CNC mode - Added functions radians(arg) and degrees(arg) which convert the argument from degrees to radians, and from radians to degrees - M915 now reports the axis or extruder speed that corresponds to the fullsteps/second value of the H parameter -- New object model variable inputs[] is provided, describing the state of each GCode input +- Added more object model properties, including inputs[] describing the state of each GPin, volumes[] describing the attached SD cards, and seqs{} to help DSF and UIs know which non-live object model properties have changed - M207 retraction parameters are now settable on a per-tool basis. The P parameter selects which tool to set. M207 with no P parameter applies the parameters provided to all existing tools. Retraction settings in the object model are moved from extruders[].retraction to tools[].retraction. - Each Z probe can now have its own deploy and retract files. Z probe number # (where # counts up from zero) looks first for deployprobe#.g and if that is not found it falls back to deployprobe.g. Similarly it used retractprobe#.g in preference to retractprobe.g. - The M401 (deploy probe) and M402 (retract probe) commands now accept an optional P parameter which is the Z probe number to deploy mor retract, default 0. @@ -27,6 +27,7 @@ Bug fixes: - M409 incorrectly allowed a '.' to be omitted between the closing square bracket of an index and the following field name - On Duet 3 in standalone mode, on the Ethernet interface the limit on the number of MDNS services was set too low, so only the 'echo' service was created - The HTTP rr_model call sometimes caused a reset due to stack overflow on the Duet WiFi +- When running true bed levelling or auto calibration, if all probe points had zero height error then the initial deviation could be reported as 'nan' RepRapFirmware 3.01-RC3 ======================= |