diff options
-rw-r--r-- | WHATS_NEW.md | 16 |
1 files changed, 11 insertions, 5 deletions
diff --git a/WHATS_NEW.md b/WHATS_NEW.md index 434bf31c..bca5c673 100644 --- a/WHATS_NEW.md +++ b/WHATS_NEW.md @@ -11,19 +11,25 @@ Upgrade notes: New features and changed behaviour: - Endstop mapping and M574 A parameter have been removed - Added 12864 menu items 534-539 +- The 12864 display no longer automatically adds a space column after each item, except for left-justified text items without an explicit width +- The 12864 display system automatically appends a % character to value/alter items that are normally expressed in percent, e.g. fan speeds, print speed, extrusion factors - M302 now waits for movement to stop - M291 now unlocks movement if it is locked, so that PanelDue or DWC can be used to jog axes if M291 was invoked from another input stream -- The status response for DWC and returned by M408 S2 now includes the workplace coordinate system number with variable name "system" -- Increased maximum number of triggers from 10 to 16 +- The status response for DWC and returned by M408 S2 now includes the workplace coordinate system number with variable name "wpl" - On the Duet Maestro, stepper driver open load detection is now disabled when the driver is operating in stealthChop mode +- Prints can now be paused and cancelled while they are waiting for temperatures to be reached +- Increased maximum number of triggers from 10 to 16 +- Increased number of output buffers on Duet WiFi/Ethernet/Maestro from 20 to 24 Bug fixes: - M585 works again -- In resurrect.g file the M290 command now commands absolute babystepping, and the filename in M23 command is enclosed in double quote marks +- In resurrect.g file the M290 command now commands absolute babystepping, the filename in M23 command is enclosed in double quote marks, ands the inches/mm setting is restored - The W5500 chip could not be reset on Duet Maestro - M109 did not run the tool change files if no tool was active initially -- If a print finishes or is cancelled when Z hop is active because of a G10 command without a subsequent G11, the Z hop is cancelled -- Fix (hopefully, not tested!) for issue with Fan 1 on Duet085 +- If a print finishes or is cancelled when Z hop is active because of a G10 command without a subsequent G11, the Z hop is cancelled (but not the associated retraction) +- Blank lines in 12864 display menu files are now ignored +- Visibility attributes were not correctly applied to 12864 display value, alter and image menu items +- Fixed (hopefully - not tested!) issue with Fan 1 on Duet085 in 2.03 beta releases Internal changes: - Use new CoreNG API with common RTOS/non-RTOS builds of CoreNG (same CoreNG as RRF 3) |