--- tag: g425 title: Backlash Calibration brief: Use a conductive object to calibrate XYZ backlash author: marcio-ao experimental: true requires: CALIBRATION_GCODE group: calibration codes: [ G425 ] notes: - | Requires `CALIBRATION_GCODE` and the following parameters: - `CALIBRATION_MEASUREMENT_RESOLUTION` determines the increments taken in mm when performing measurements. - `CALIBRATION_FEEDRATE_SLOW`, `CALIBRATION_FEEDRATE_FAST` and `CALIBRATION_FEEDRATE_TRAVEL` determine the speed of motion during the calibration. - `CALIBRATION_NOZZLE_TIP_HEIGHT` and `CALIBRATION_NOZZLE_OUTER_DIAMETER` refer to the conical part of the nozzle tip. - `CALIBRATION_REPORTING` enables `G425 V` for reporting of measurements. - `CALIBRATION_OBJECT_CENTER` and `CALIBRATION_OBJECT_DIMENSIONS` define the true location and dimensions of a cube/bolt/washer mounted on the bed. - `CALIBRATION_MEASURE_RIGHT`, `CALIBRATION_MEASURE_FRONT`, `CALIBRATION_MEASURE_LEFT` and `CALIBRATION_MEASURE_BACK` define the usable touch points. Comment out any sides which are unreachable by the probe. For best results, all four sides should be reachable. - `CALIBRATION_PIN`, `CALIBRATION_PIN_INVERTING`, `CALIBRATION_PIN_PULLDOWN` and `CALIBRATION_PIN_PULLUP` configure the pin used for calibration. For example, if the nozzle is grounded, the calibation cube would be connected to a digital input pin with a pull-up enabled. parameters: - tag: B optional: true description: Perform calibration of backlash only. - tag: T optional: true description: Perform calibration of one toolhead only. values: - tag: index type: int - tag: V optional: true description: Probe cube and print position, error, backlash and hotend offset. (Requires `CALIBRATION_REPORTING`) - tag: U optional: true description: 'Uncertainty: how far to start probe away from the cube (mm)' values: - tag: linear type: float examples: - pre: 'Check positional accuracy before calibration (Requires `CALIBRATION_REPORTING`):' code: - T1 ; Switch to second nozzle - G425 V ; Showing positional report for T1 - T0 ; Switch to first nozzle - G425 V ; Showing positional report for T0 - pre: 'Perform automatic calibration:' code: - G425 ; Perform full calibration sequence - M425 F1 S0 ; Enable backlash compensation at 100% - pre: 'Check positional accuracy after calibration (Requires `CALIBRATION_REPORTING`):' code: - T1 ; Switch to second nozzle - G425 V ; Validate by showing report for T1 - T0 ; Switch to first nozzle - G425 V ; Validate by showing report for T0 --- This command performs an automatic calibration of backlash, positional errors, and nozzle offset by touching the nozzle to the sides of a bed-mounted, electrically-conductive object (_e.g.,_ a cube, washer or bolt). This command measures backlash but doesn't enable backlash correction. Use [`M425`](/docs/gcode/M425.html) to enable backlash correction.