authorVyacheslav Khaliev <vyacheslav.khaliev@zabbix.com>2022-04-14 14:57:31 +0300
committerVyacheslav Khaliev <vyacheslav.khaliev@zabbix.com>2022-04-14 14:57:31 +0300
commite80907fffcde6524802f7ee757db8d6d159bae2e (patch)
treec3ba5d48aaaecf6936a24b90962d86108267e6ab /templates/net/dlink_des7200_snmp
parent54a5f9d8c8719b0511609f42fb6d32dc45282374 (diff)
.........T [ZBXNEXT-7582] fixed context macros
Diffstat (limited to 'templates/net/dlink_des7200_snmp')
-rw-r--r--templates/net/dlink_des7200_snmp/README.md10
-rw-r--r--templates/net/dlink_des7200_snmp/template_net_dlink_des7200_snmp.yaml28
2 files changed, 19 insertions, 19 deletions
diff --git a/templates/net/dlink_des7200_snmp/README.md b/templates/net/dlink_des7200_snmp/README.md
index 2c3796a0159..9e5be57d26f 100644
--- a/templates/net/dlink_des7200_snmp/README.md
+++ b/templates/net/dlink_des7200_snmp/README.md
@@ -61,7 +61,7 @@ There are no template links in this template.
|Group|Name|Description|Type|Key and additional info|
|-----|----|-----------|----|---------------------|
-|CPU |CPU utilization |<p>MIB: MY-PROCESS-MIB</p><p>CPU utilization in %</p> |SNMP |system.cpu.util[myCPUUtilization5Min.0] |
+|CPU |CPU utilization |<p>MIB: MY-PROCESS-MIB</p><p>CPU utilization in %.</p> |SNMP |system.cpu.util[myCPUUtilization5Min.0] |
|Fans |{#SNMPVALUE}: Fan status |<p>MIB: MY-SYSTEM-MIB</p> |SNMP |sensor.fan.status[mySystemFanIsNormal.{#SNMPINDEX}] |
|General |SNMP traps (fallback) |<p>The item is used to collect all SNMP traps unmatched by other snmptrap items</p> |SNMP_TRAP |snmptrap.fallback |
|General |System location |<p>MIB: SNMPv2-MIB</p><p>The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.</p> |SNMP |system.location[sysLocation.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
@@ -106,14 +106,14 @@ There are no template links in this template.
|Interface {#IFNAME}({#IFALIAS}): High error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/D-Link DES 7200 SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/D-Link DES 7200 SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/D-Link DES 7200 SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/D-Link DES 7200 SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/D-Link DES 7200 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/D-Link DES 7200 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/D-Link DES 7200 SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/D-Link DES 7200 SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/D-Link DES 7200 SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/D-Link DES 7200 SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/D-Link DES 7200 SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/D-Link DES 7200 SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/D-Link DES 7200 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`<p>Recovery expression:</p>`(change(/D-Link DES 7200 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/D-Link DES 7200 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/D-Link DES 7200 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
|{#SNMPVALUE}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`count(/D-Link DES 7200 SNMP/sensor.psu.status[mySystemElectricalSourceIsNormal.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/D-Link DES 7200 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/D-Link DES 7200 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/D-Link DES 7200 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
|Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/D-Link DES 7200 SNMP/icmpping,#3)=0` |HIGH | |
|High ICMP ping loss |<p>-</p> |`min(/D-Link DES 7200 SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/D-Link DES 7200 SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
|High ICMP ping response time |<p>-</p> |`avg(/D-Link DES 7200 SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> |
-|{#SNMPVALUE}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}`<p>Recovery expression:</p>`max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3` |WARNING |<p>**Depends on**:</p><p>- {#SNMPVALUE}: Temperature is above critical threshold</p> |
-|{#SNMPVALUE}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}`<p>Recovery expression:</p>`max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3` |HIGH | |
-|{#SNMPVALUE}: Temperature is too low |<p>-</p> |`avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}`<p>Recovery expression:</p>`min(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3` |AVERAGE | |
+|{#SNMPVALUE}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SNMPVALUE}: Temperature is above critical threshold</p> |
+|{#SNMPVALUE}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3` |HIGH | |
+|{#SNMPVALUE}: Temperature is too low |<p>-</p> |`avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`min(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3` |AVERAGE | |
## Feedback
diff --git a/templates/net/dlink_des7200_snmp/template_net_dlink_des7200_snmp.yaml b/templates/net/dlink_des7200_snmp/template_net_dlink_des7200_snmp.yaml
index aea11bd53fc..147b0c1effa 100644
--- a/templates/net/dlink_des7200_snmp/template_net_dlink_des7200_snmp.yaml
+++ b/templates/net/dlink_des7200_snmp/template_net_dlink_des7200_snmp.yaml
@@ -1,6 +1,6 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:00:27Z'
+ date: '2022-04-14T10:16:34Z'
groups:
-
uuid: 36bff6c29af64692839d077febfc7079
@@ -170,7 +170,7 @@ zabbix_export:
units: '%'
description: |
MIB: MY-PROCESS-MIB
- CPU utilization in %
+ CPU utilization in %.
tags:
-
tag: component
@@ -440,7 +440,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1129,11 +1129,11 @@ zabbix_export:
trigger_prototypes:
-
uuid: b675df20392d458f9a53dace6bde978a
- expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}'
+ expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3'
+ recovery_expression: 'max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
name: '{#SNMPVALUE}: Temperature is above critical threshold'
- event_name: '{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
+ event_name: '{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
@@ -1146,19 +1146,19 @@ zabbix_export:
value: performance
-
uuid: 8486ed430ee24b13b65786e5b4857684
- expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}'
+ expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3'
+ recovery_expression: 'max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
name: '{#SNMPVALUE}: Temperature is above warning threshold'
- event_name: '{#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:""}'
+ event_name: '{#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
-
name: '{#SNMPVALUE}: Temperature is above critical threshold'
- expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}'
- recovery_expression: 'max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3'
+ expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
+ recovery_expression: 'max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
tags:
-
tag: scope
@@ -1168,11 +1168,11 @@ zabbix_export:
value: performance
-
uuid: ef5a9113e96d4cc095d384cbeeef9bc5
- expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}'
+ expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'min(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3'
+ recovery_expression: 'min(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
name: '{#SNMPVALUE}: Temperature is too low'
- event_name: '{#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:""}'
+ event_name: '{#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
tags: