diff options
author | Andrew Biba <andrew.biba@zabbix.com> | 2022-06-07 23:32:37 +0300 |
---|---|---|
committer | Andrew Biba <andrew.biba@zabbix.com> | 2022-06-07 23:32:37 +0300 |
commit | 24236a893e0037d71eefe61e621486433ab81c20 (patch) | |
tree | 5990290103a2861307c0f2903204cee6b22a5d6a /templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml | |
parent | 4b8e6b21b37de3bce14bc55ca90d6d6cda00ab0b (diff) |
.........T [ZBXNEXT-7596] updated templates for 6.2 version (template_groups and host_groups properties)
Diffstat (limited to 'templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml')
-rw-r--r-- | templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml | 178 |
1 files changed, 3 insertions, 175 deletions
diff --git a/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml b/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml index d95833819fe..d6297fbdc67 100644 --- a/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml +++ b/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:34Z' - groups: + date: '2022-06-07T19:37:51Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: b070a774806547ffa7e688b2746c8d58 - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC UPS Symmetra RX SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC UPS Symmetra RX SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC UPS Symmetra RX SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC UPS Symmetra RX SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC UPS Symmetra RX SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC UPS Symmetra RX SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC UPS Symmetra RX SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC UPS Symmetra RX SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC UPS Symmetra RX SNMP' valuemaps: - uuid: e2877a188bd24918992f8c7878550924 |