diff options
Diffstat (limited to 'templates/app/pfsense_snmp/README.md')
-rw-r--r-- | templates/app/pfsense_snmp/README.md | 6 |
1 files changed, 4 insertions, 2 deletions
diff --git a/templates/app/pfsense_snmp/README.md b/templates/app/pfsense_snmp/README.md index 92ca642601b..34c80b95cab 100644 --- a/templates/app/pfsense_snmp/README.md +++ b/templates/app/pfsense_snmp/README.md @@ -55,6 +55,8 @@ No specific Zabbix configuration is required. |{$SWAP.PFREE.MIN.WARN} |<p>Threshold of free swap space for warning trigger in %.</p> |`50` | |{$VFS.DEV.DEVNAME.MATCHES} |<p>This macro is used in block devices discovery. Can be overridden on the host or linked template level</p> |`.+` | |{$VFS.DEV.DEVNAME.NOT_MATCHES} |<p>This macro is used in block devices discovery. Can be overridden on the host or linked template level</p> |`^(loop[0-9]*|sd[a-z][0-9]+|nbd[0-9]+|sr[0-9]+|fd[0-9]+|dm-[0-9]+|ram[0-9]+|ploop[a-z0-9]+|md[0-9]*|hcp[0-9]*|cd[0-9]*|pass[0-9]*|zram[0-9]*)` | +|{$VFS.FS.FREE.MIN.CRIT} |<p>The critical threshold of the filesystem utilization.</p> |`5G` | +|{$VFS.FS.FREE.MIN.WARN} |<p>The warning threshold of the filesystem utilization.</p> |`10G` | |{$VFS.FS.FSNAME.MATCHES} |<p>This macro is used in filesystems discovery. Can be overridden on the host or linked template level</p> |`.+` | |{$VFS.FS.FSNAME.NOT_MATCHES} |<p>This macro is used in filesystems discovery. Can be overridden on the host or linked template level</p> |`^(/dev|/sys|/run|/var/run|/proc|.+/shm$)` | |{$VFS.FS.FSTYPE.MATCHES} |<p>This macro is used in filesystems discovery. Can be overridden on the host or linked template level</p> |`.*(9.3|hrFSBerkeleyFFS)$` | @@ -191,8 +193,8 @@ There are no template links in this template. |PFSense: High ICMP ping response time |<p>Average ICMP response time is too big.</p> |`avg(/PFSense SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- PFSense: Unavailable by ICMP ping</p> | |PFSense: has been restarted (uptime < 10m) |<p>Uptime is less than 10 minutes.</p> |`last(/PFSense SNMP/system.uptime)<10m` |INFO |<p>Manual close: YES</p> | |PFSense: No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/PFSense SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- PFSense: Unavailable by ICMP ping</p> | -|PFSense: [{#FSNAME}]: Disk space is critically low (used > {$VFS.FS.PUSED.MAX.CRIT:"{#FSNAME}"}%) |<p>Two conditions should match: First, space utilization should be above {$VFS.FS.PUSED.MAX.CRIT:"{#FSNAME}"}.</p><p>Second condition should be one of the following:</p><p> - The disk free space is less than 5G.</p><p> - The disk will be full in less than 24 hours.</p> |`last(/PFSense SNMP/vfs.fs.pused[{#SNMPINDEX}])>{$VFS.FS.PUSED.MAX.CRIT:"{#FSNAME}"} and ((last(/PFSense SNMP/vfs.fs.total[{#SNMPINDEX}])-last(/PFSense SNMP/vfs.fs.used[{#SNMPINDEX}]))<5G or timeleft(/PFSense SNMP/vfs.fs.pused[{#SNMPINDEX}],1h,100)<1d) ` |AVERAGE |<p>Manual close: YES</p> | -|PFSense: [{#FSNAME}]: Disk space is low (used > {$VFS.FS.PUSED.MAX.WARN:"{#FSNAME}"}%) |<p>Two conditions should match: First, space utilization should be above {$VFS.FS.PUSED.MAX.WARN:"{#FSNAME}"}.</p><p>Second condition should be one of the following:</p><p> - The disk free space is less than 5G.</p><p> - The disk will be full in less than 24 hours.</p> |`last(/PFSense SNMP/vfs.fs.pused[{#SNMPINDEX}])>{$VFS.FS.PUSED.MAX.WARN:"{#FSNAME}"} and ((last(/PFSense SNMP/vfs.fs.total[{#SNMPINDEX}])-last(/PFSense SNMP/vfs.fs.used[{#SNMPINDEX}]))<10G or timeleft(/PFSense SNMP/vfs.fs.pused[{#SNMPINDEX}],1h,100)<1d) ` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- PFSense: [{#FSNAME}]: Disk space is critically low (used > {$VFS.FS.PUSED.MAX.CRIT:"{#FSNAME}"}%)</p> | +|PFSense: [{#FSNAME}]: Disk space is critically low (used > {$VFS.FS.PUSED.MAX.CRIT:"{#FSNAME}"}%) |<p>Two conditions should match: First, space utilization should be above {$VFS.FS.PUSED.MAX.CRIT:"{#FSNAME}"}.</p><p>Second condition should be one of the following:</p><p> - The disk free space is less than {$VFS.FS.FREE.MIN.CRIT:"{#FSNAME}"}.</p><p> - The disk will be full in less than 24 hours.</p> |`last(/PFSense SNMP/vfs.fs.pused[{#SNMPINDEX}])>{$VFS.FS.PUSED.MAX.CRIT:"{#FSNAME}"} and ((last(/PFSense SNMP/vfs.fs.total[{#SNMPINDEX}])-last(/PFSense SNMP/vfs.fs.used[{#SNMPINDEX}]))<{$VFS.FS.FREE.MIN.CRIT:"{#FSNAME}"} or timeleft(/PFSense SNMP/vfs.fs.pused[{#SNMPINDEX}],1h,100)<1d) ` |AVERAGE |<p>Manual close: YES</p> | +|PFSense: [{#FSNAME}]: Disk space is low (used > {$VFS.FS.PUSED.MAX.WARN:"{#FSNAME}"}%) |<p>Two conditions should match: First, space utilization should be above {$VFS.FS.PUSED.MAX.WARN:"{#FSNAME}"}.</p><p>Second condition should be one of the following:</p><p> - The disk free space is less than {$VFS.FS.FREE.MIN.WARN:"{#FSNAME}"}.</p><p> - The disk will be full in less than 24 hours.</p> |`last(/PFSense SNMP/vfs.fs.pused[{#SNMPINDEX}])>{$VFS.FS.PUSED.MAX.WARN:"{#FSNAME}"} and ((last(/PFSense SNMP/vfs.fs.total[{#SNMPINDEX}])-last(/PFSense SNMP/vfs.fs.used[{#SNMPINDEX}]))<{$VFS.FS.FREE.MIN.WARN:"{#FSNAME}"} or timeleft(/PFSense SNMP/vfs.fs.pused[{#SNMPINDEX}],1h,100)<1d) ` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- PFSense: [{#FSNAME}]: Disk space is critically low (used > {$VFS.FS.PUSED.MAX.CRIT:"{#FSNAME}"}%)</p> | |PFSense: [{#FSNAME}]: Running out of free inodes (free < {$VFS.FS.INODE.PFREE.MIN.CRIT:"{#FSNAME}"}%) |<p>It may become impossible to write to disk if there are no index nodes left.</p><p>As symptoms, 'No space left on device' or 'Disk is full' errors may be seen even though free space is available.</p> |`min(/PFSense SNMP/vfs.fs.inode.pfree[{#SNMPINDEX}],5m)<{$VFS.FS.INODE.PFREE.MIN.CRIT:"{#FSNAME}"}` |AVERAGE | | |PFSense: [{#FSNAME}]: Running out of free inodes (free < {$VFS.FS.INODE.PFREE.MIN.WARN:"{#FSNAME}"}%) |<p>It may become impossible to write to disk if there are no index nodes left.</p><p>As symptoms, 'No space left on device' or 'Disk is full' errors may be seen even though free space is available.</p> |`min(/PFSense SNMP/vfs.fs.inode.pfree[{#SNMPINDEX}],5m)<{$VFS.FS.INODE.PFREE.MIN.WARN:"{#FSNAME}"}` |WARNING |<p>**Depends on**:</p><p>- PFSense: [{#FSNAME}]: Running out of free inodes (free < {$VFS.FS.INODE.PFREE.MIN.CRIT:"{#FSNAME}"}%)</p> | |