diff options
Diffstat (limited to 'templates/net/brocade_fc_sw_snmp/README.md')
-rw-r--r-- | templates/net/brocade_fc_sw_snmp/README.md | 10 |
1 files changed, 5 insertions, 5 deletions
diff --git a/templates/net/brocade_fc_sw_snmp/README.md b/templates/net/brocade_fc_sw_snmp/README.md index e6e287bf3a0..632b7c213f0 100644 --- a/templates/net/brocade_fc_sw_snmp/README.md +++ b/templates/net/brocade_fc_sw_snmp/README.md @@ -84,7 +84,7 @@ There are no template links in this template. |General |System description |<p>MIB: SNMPv2-MIB</p><p>A textual description of the entity. This value should</p><p>include the full name and version identification of the system's hardware type, software operating-system, and</p><p>networking software.</p> |SNMP |system.descr[sysDescr.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> | |Inventory |Hardware serial number |<p>MIB: SW-MIB</p> |SNMP |system.hw.serialnumber<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> | |Inventory |Firmware version |<p>MIB: SW-MIB</p> |SNMP |system.hw.firmware<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> | -|Memory |Memory utilization |<p>MIB: SW-MIB</p><p>Memory utilization in %</p> |SNMP |vm.memory.util[swMemUsage.0] | +|Memory |Memory utilization |<p>MIB: SW-MIB</p><p>Memory utilization in %.</p> |SNMP |vm.memory.util[swMemUsage.0] | |Network interfaces |Interface {#IFNAME}({#IFALIAS}): Operational status |<p>MIB: IF-MIB</p><p>The current operational state of the interface.</p><p>- The testing(3) state indicates that no operational packet scan be passed</p><p>- If ifAdminStatus is down(2) then ifOperStatus should be down(2)</p><p>- If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic</p><p>- It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection)</p><p>- It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state</p><p>- It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.</p> |SNMP |net.if.status[ifOperStatus.{#SNMPINDEX}] | |Network interfaces |Interface {#IFNAME}({#IFALIAS}): Bits received |<p>MIB: IF-MIB</p><p>The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.</p> |SNMP |net.if.in[ifHCInOctets.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- CHANGE_PER_SECOND</p><p>- MULTIPLIER: `8`</p> | |Network interfaces |Interface {#IFNAME}({#IFALIAS}): Bits sent |<p>MIB: IF-MIB</p><p>The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.</p> |SNMP |net.if.out[ifHCOutOctets.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- CHANGE_PER_SECOND</p><p>- MULTIPLIER: `8`</p> | @@ -123,14 +123,14 @@ There are no template links in this template. |{#SENSOR_INFO}: Power supply is not in normal state |<p>Please check the power supply unit for errors</p> |`count(/Brocade FC SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1` |INFO |<p>**Depends on**:</p><p>- {#SENSOR_INFO}: Power supply is in critical state</p> | |System status is in critical state |<p>Please check the device for errors</p> |`count(/Brocade FC SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1` |HIGH | | |System status is in warning state |<p>Please check the device for warnings</p> |`count(/Brocade FC SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"offline\"}")=1 or count(/Brocade FC SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"testing\"}")=1` |WARNING |<p>**Depends on**:</p><p>- System status is in critical state</p> | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/Brocade FC SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/Brocade FC SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/Brocade FC SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> | |Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/Brocade FC SNMP/icmpping,#3)=0` |HIGH | | |High ICMP ping loss |<p>-</p> |`min(/Brocade FC SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade FC SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> | |High ICMP ping response time |<p>-</p> |`avg(/Brocade FC SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> | -|{#SENSOR_INFO}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:""} or last(/Brocade FC SNMP/sensor.temp.status[swSensorStatus.{#SNMPINDEX}])={$TEMP_WARN_STATUS} `<p>Recovery expression:</p>`max(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_INFO}: Temperature is above critical threshold</p> | -|{#SENSOR_INFO}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}`<p>Recovery expression:</p>`max(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3` |HIGH | | -|{#SENSOR_INFO}: Temperature is too low |<p>-</p> |`avg(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}`<p>Recovery expression:</p>`min(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3` |AVERAGE | | +|{#SENSOR_INFO}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_INFO}"} or last(/Brocade FC SNMP/sensor.temp.status[swSensorStatus.{#SNMPINDEX}])={$TEMP_WARN_STATUS} `<p>Recovery expression:</p>`max(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_INFO}"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_INFO}: Temperature is above critical threshold</p> | +|{#SENSOR_INFO}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}`<p>Recovery expression:</p>`max(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3` |HIGH | | +|{#SENSOR_INFO}: Temperature is too low |<p>-</p> |`avg(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}`<p>Recovery expression:</p>`min(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}+3` |AVERAGE | | ## Feedback |