diff options
Diffstat (limited to 'templates/net/brocade_foundry_sw_snmp')
-rw-r--r-- | templates/net/brocade_foundry_sw_snmp/README.md | 16 | ||||
-rw-r--r-- | templates/net/brocade_foundry_sw_snmp/template_net_brocade_foundry_sw_snmp.yaml | 50 |
2 files changed, 33 insertions, 33 deletions
diff --git a/templates/net/brocade_foundry_sw_snmp/README.md b/templates/net/brocade_foundry_sw_snmp/README.md index a9ba7830e0d..71c9c8ed136 100644 --- a/templates/net/brocade_foundry_sw_snmp/README.md +++ b/templates/net/brocade_foundry_sw_snmp/README.md @@ -121,14 +121,14 @@ There are no template links in this template. |Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/Brocade_Foundry Nonstackable SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Brocade_Foundry Nonstackable SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Brocade_Foundry Nonstackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Brocade_Foundry Nonstackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Brocade_Foundry Nonstackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Brocade_Foundry Nonstackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Brocade_Foundry Nonstackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Brocade_Foundry Nonstackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Brocade_Foundry Nonstackable SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`<p>Recovery expression:</p>`(change(/Brocade_Foundry Nonstackable SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Brocade_Foundry Nonstackable SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/Brocade_Foundry Nonstackable SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> | |PSU {#PSU_INDEX}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`count(/Brocade_Foundry Nonstackable SNMP/sensor.psu.status[snChasPwrSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1` |AVERAGE | | |PSU {#PSU_INDEX}: Power supply is not in normal state |<p>Please check the power supply unit for errors</p> |`count(/Brocade_Foundry Nonstackable SNMP/sensor.psu.status[snChasPwrSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1` |INFO |<p>**Depends on**:</p><p>- PSU {#PSU_INDEX}: Power supply is in critical state</p> | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/Brocade_Foundry Nonstackable SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/Brocade_Foundry Nonstackable SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/Brocade_Foundry Nonstackable SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> | |Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/Brocade_Foundry Nonstackable SNMP/icmpping,#3)=0` |HIGH | | |High ICMP ping loss |<p>-</p> |`min(/Brocade_Foundry Nonstackable SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade_Foundry Nonstackable SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> | |High ICMP ping response time |<p>-</p> |`avg(/Brocade_Foundry Nonstackable SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> | -|{#SENSOR_DESCR}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}`<p>Recovery expression:</p>`max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_DESCR}: Temperature is above critical threshold</p> | -|{#SENSOR_DESCR}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}`<p>Recovery expression:</p>`max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3` |HIGH | | -|{#SENSOR_DESCR}: Temperature is too low |<p>-</p> |`avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}`<p>Recovery expression:</p>`min(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3` |AVERAGE | | +|{#SENSOR_DESCR}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_DESCR}"}`<p>Recovery expression:</p>`max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_DESCR}"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_DESCR}: Temperature is above critical threshold</p> | +|{#SENSOR_DESCR}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_DESCR}"}`<p>Recovery expression:</p>`max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_DESCR}"}-3` |HIGH | | +|{#SENSOR_DESCR}: Temperature is too low |<p>-</p> |`avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}`<p>Recovery expression:</p>`min(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}+3` |AVERAGE | | |Chassis #{#SNMPINDEX}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Chassis"}`<p>Recovery expression:</p>`max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:"Chassis"}-3` |WARNING |<p>**Depends on**:</p><p>- Chassis #{#SNMPINDEX}: Temperature is above critical threshold</p> | |Chassis #{#SNMPINDEX}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Chassis"}`<p>Recovery expression:</p>`max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Chassis"}-3` |HIGH | | |Chassis #{#SNMPINDEX}: Temperature is too low |<p>-</p> |`avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Chassis"}`<p>Recovery expression:</p>`min(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"Chassis"}+3` |AVERAGE | | @@ -258,14 +258,14 @@ There are no template links in this template. |Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/Brocade_Foundry Stackable SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Brocade_Foundry Stackable SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Brocade_Foundry Stackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Brocade_Foundry Stackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Brocade_Foundry Stackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Brocade_Foundry Stackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Brocade_Foundry Stackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Brocade_Foundry Stackable SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Brocade_Foundry Stackable SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`<p>Recovery expression:</p>`(change(/Brocade_Foundry Stackable SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Brocade_Foundry Stackable SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/Brocade_Foundry Stackable SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> | |Unit {#PSU_UNIT} PSU {#PSU_INDEX}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`count(/Brocade_Foundry Stackable SNMP/sensor.psu.status[snChasPwrSupply2OperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1` |AVERAGE | | |Unit {#PSU_UNIT} PSU {#PSU_INDEX}: Power supply is not in normal state |<p>Please check the power supply unit for errors</p> |`count(/Brocade_Foundry Stackable SNMP/sensor.psu.status[snChasPwrSupply2OperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1` |INFO |<p>**Depends on**:</p><p>- Unit {#PSU_UNIT} PSU {#PSU_INDEX}: Power supply is in critical state</p> | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/Brocade_Foundry Stackable SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/Brocade_Foundry Stackable SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/Brocade_Foundry Stackable SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> | |Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/Brocade_Foundry Stackable SNMP/icmpping,#3)=0` |HIGH | | |High ICMP ping loss |<p>-</p> |`min(/Brocade_Foundry Stackable SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade_Foundry Stackable SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> | |High ICMP ping response time |<p>-</p> |`avg(/Brocade_Foundry Stackable SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> | -|{#SENSOR_DESCR}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}`<p>Recovery expression:</p>`max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_DESCR}: Temperature is above critical threshold</p> | -|{#SENSOR_DESCR}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}`<p>Recovery expression:</p>`max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3` |HIGH | | -|{#SENSOR_DESCR}: Temperature is too low |<p>-</p> |`avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}`<p>Recovery expression:</p>`min(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3` |AVERAGE | | +|{#SENSOR_DESCR}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_DESCR}"}`<p>Recovery expression:</p>`max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_DESCR}"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_DESCR}: Temperature is above critical threshold</p> | +|{#SENSOR_DESCR}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_DESCR}"}`<p>Recovery expression:</p>`max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_DESCR}"}-3` |HIGH | | +|{#SENSOR_DESCR}: Temperature is too low |<p>-</p> |`avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}`<p>Recovery expression:</p>`min(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}+3` |AVERAGE | | ## Feedback diff --git a/templates/net/brocade_foundry_sw_snmp/template_net_brocade_foundry_sw_snmp.yaml b/templates/net/brocade_foundry_sw_snmp/template_net_brocade_foundry_sw_snmp.yaml index e86ef4eb120..8a841731d31 100644 --- a/templates/net/brocade_foundry_sw_snmp/template_net_brocade_foundry_sw_snmp.yaml +++ b/templates/net/brocade_foundry_sw_snmp/template_net_brocade_foundry_sw_snmp.yaml @@ -1,6 +1,6 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:00:11Z' + date: '2022-04-14T09:55:12Z' groups: - uuid: 36bff6c29af64692839d077febfc7079 @@ -390,7 +390,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1186,11 +1186,11 @@ zabbix_export: trigger_prototypes: - uuid: bace15be86774bb4a46ca491b3b53516 - expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}' + expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_DESCR}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3' + recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_DESCR}"}-3' name: '{#SENSOR_DESCR}: Temperature is above critical threshold' - event_name: '{#SENSOR_DESCR}: Temperature is above critical threshold: >{$TEMP_CRIT:""}' + event_name: '{#SENSOR_DESCR}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SENSOR_DESCR}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' @@ -1203,19 +1203,19 @@ zabbix_export: value: performance - uuid: 3687c8a7e88949fb9953049fb0f5e54d - expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}' + expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_DESCR}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3' + recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_DESCR}"}-3' name: '{#SENSOR_DESCR}: Temperature is above warning threshold' - event_name: '{#SENSOR_DESCR}: Temperature is above warning threshold: >{$TEMP_WARN:""}' + event_name: '{#SENSOR_DESCR}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SENSOR_DESCR}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' dependencies: - name: '{#SENSOR_DESCR}: Temperature is above critical threshold' - expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}' - recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3' + expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_DESCR}"}' + recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_DESCR}"}-3' tags: - tag: scope @@ -1225,11 +1225,11 @@ zabbix_export: value: performance - uuid: fbe5f29b241248b4b4bff5d55fcc2180 - expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}' + expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'min(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3' + recovery_expression: 'min(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}+3' name: '{#SENSOR_DESCR}: Temperature is too low' - event_name: '{#SENSOR_DESCR}: Temperature is too low: <{$TEMP_CRIT_LOW:""}' + event_name: '{#SENSOR_DESCR}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: AVERAGE tags: @@ -2656,7 +2656,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -3439,11 +3439,11 @@ zabbix_export: trigger_prototypes: - uuid: e1a63b2ebef549ebbd95b307feee8b8d - expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}' + expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_DESCR}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3' + recovery_expression: 'max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_DESCR}"}-3' name: '{#SENSOR_DESCR}: Temperature is above critical threshold' - event_name: '{#SENSOR_DESCR}: Temperature is above critical threshold: >{$TEMP_CRIT:""}' + event_name: '{#SENSOR_DESCR}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SENSOR_DESCR}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' @@ -3456,19 +3456,19 @@ zabbix_export: value: performance - uuid: c1e348e8a5f24100a5b29a840a43dca9 - expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}' + expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_DESCR}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3' + recovery_expression: 'max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_DESCR}"}-3' name: '{#SENSOR_DESCR}: Temperature is above warning threshold' - event_name: '{#SENSOR_DESCR}: Temperature is above warning threshold: >{$TEMP_WARN:""}' + event_name: '{#SENSOR_DESCR}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SENSOR_DESCR}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' dependencies: - name: '{#SENSOR_DESCR}: Temperature is above critical threshold' - expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}' - recovery_expression: 'max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3' + expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_DESCR}"}' + recovery_expression: 'max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_DESCR}"}-3' tags: - tag: scope @@ -3478,11 +3478,11 @@ zabbix_export: value: performance - uuid: 722ee93a637643e9b3cff31e5ea5151d - expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}' + expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'min(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3' + recovery_expression: 'min(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}+3' name: '{#SENSOR_DESCR}: Temperature is too low' - event_name: '{#SENSOR_DESCR}: Temperature is too low: <{$TEMP_CRIT_LOW:""}' + event_name: '{#SENSOR_DESCR}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: AVERAGE tags: |