diff options
Diffstat (limited to 'templates/net/cisco_catalyst_3750/cisco_catalyst_3750_24ts_snmp/template_net_cisco_catalyst_3750_24ts_snmp.yaml')
-rw-r--r-- | templates/net/cisco_catalyst_3750/cisco_catalyst_3750_24ts_snmp/template_net_cisco_catalyst_3750_24ts_snmp.yaml | 81 |
1 files changed, 80 insertions, 1 deletions
diff --git a/templates/net/cisco_catalyst_3750/cisco_catalyst_3750_24ts_snmp/template_net_cisco_catalyst_3750_24ts_snmp.yaml b/templates/net/cisco_catalyst_3750/cisco_catalyst_3750_24ts_snmp/template_net_cisco_catalyst_3750_24ts_snmp.yaml index 41d2d7931f5..e5f5224813b 100644 --- a/templates/net/cisco_catalyst_3750/cisco_catalyst_3750_24ts_snmp/template_net_cisco_catalyst_3750_24ts_snmp.yaml +++ b/templates/net/cisco_catalyst_3750/cisco_catalyst_3750_24ts_snmp/template_net_cisco_catalyst_3750_24ts_snmp.yaml @@ -1,11 +1,13 @@ zabbix_export: version: '5.4' - date: '2021-05-09T00:00:00Z' + date: '2021-05-10T19:41:22Z' groups: - + uuid: 57b7ae836ca64446ba2c296389c009b7 name: Templates/Modules templates: - + uuid: 30d084c6b7844b7cab6cf820b00bb7b2 template: 'Cisco Catalyst 3750V2-24TS SNMP' name: 'Cisco Catalyst 3750V2-24TS SNMP' description: | @@ -26,6 +28,7 @@ zabbix_export: name: Templates/Modules items: - + uuid: 872058629f19424995e696d1354fbe01 name: 'ICMP ping' type: SIMPLE key: icmpping @@ -38,11 +41,13 @@ zabbix_export: value: Status triggers: - + uuid: 4b6a2967149642a0a6f2ba1c12b73fad expression: 'max(/Cisco Catalyst 3750V2-24TS SNMP/icmpping,#3)=0' name: 'Unavailable by ICMP ping' priority: HIGH description: 'Last three attempts returned timeout. Please check device connectivity.' - + uuid: 56b5f81de3c34f2aa9acd399dd212d62 name: 'ICMP loss' type: SIMPLE key: icmppingloss @@ -55,6 +60,7 @@ zabbix_export: value: Status triggers: - + uuid: 8b17b555fca74cdda0bb0aa5a135c732 expression: 'min(/Cisco Catalyst 3750V2-24TS SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-24TS SNMP/icmppingloss,5m)<100' name: 'High ICMP ping loss' opdata: 'Loss: {ITEM.LASTVALUE1}' @@ -64,6 +70,7 @@ zabbix_export: name: 'Unavailable by ICMP ping' expression: 'max(/Cisco Catalyst 3750V2-24TS SNMP/icmpping,#3)=0' - + uuid: d34fc050448e4c48b303bf8c75c50060 name: 'ICMP response time' type: SIMPLE key: icmppingsec @@ -76,6 +83,7 @@ zabbix_export: value: Status triggers: - + uuid: 2b5091f33937424baef9d7290805dd2b expression: 'avg(/Cisco Catalyst 3750V2-24TS SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' name: 'High ICMP ping response time' opdata: 'Value: {ITEM.LASTVALUE1}' @@ -88,6 +96,7 @@ zabbix_export: name: 'Unavailable by ICMP ping' expression: 'max(/Cisco Catalyst 3750V2-24TS SNMP/icmpping,#3)=0' - + uuid: c7a43b6281384161b6e1f28840d55aa1 name: 'SNMP traps (fallback)' type: SNMP_TRAP key: snmptrap.fallback @@ -101,6 +110,7 @@ zabbix_export: tag: Application value: General - + uuid: 7f563d184760420080849d161bf373f6 name: 'System contact details' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.4.0 @@ -123,6 +133,7 @@ zabbix_export: tag: Application value: General - + uuid: 74af4fbc07284c9eb9d4a913fd5e7b2b name: 'System description' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.1.0 @@ -146,6 +157,7 @@ zabbix_export: tag: Application value: General - + uuid: a7cf2f68a1c842e081deec4a16410071 name: 'Hardware model name' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.13.1 @@ -166,6 +178,7 @@ zabbix_export: tag: Application value: Inventory - + uuid: 6d9b2e70dd61424f8f0ffebf89d20853 name: 'Hardware serial number' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.11.1 @@ -187,12 +200,14 @@ zabbix_export: value: Inventory triggers: - + uuid: cf93ca1a6c414de99b01446977f5795d expression: '(last(/Cisco Catalyst 3750V2-24TS SNMP/system.hw.serialnumber,#1)<>last(/Cisco Catalyst 3750V2-24TS SNMP/system.hw.serialnumber,#2))=1 and length(last(/Cisco Catalyst 3750V2-24TS SNMP/system.hw.serialnumber))>0' name: 'Device has been replaced (new serial number received)' priority: INFO description: 'Device serial number has changed. Ack to close' manual_close: 'YES' - + uuid: cc4aa80bbd2d49f9bca23b305399f0fa name: 'System location' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.6.0 @@ -215,6 +230,7 @@ zabbix_export: tag: Application value: General - + uuid: 726fa93646ad429789dcec2fbfabc6ff name: 'System name' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.5.0 @@ -238,12 +254,14 @@ zabbix_export: value: General triggers: - + uuid: ef133a22557d417e96866109020352a2 expression: '(last(/Cisco Catalyst 3750V2-24TS SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-24TS SNMP/system.name,#2))=1 and length(last(/Cisco Catalyst 3750V2-24TS SNMP/system.name))>0' name: 'System name has changed (new name: {ITEM.VALUE})' priority: INFO description: 'System name has changed. Ack to close.' manual_close: 'YES' - + uuid: 5e7cd491cf664de0b5046cd011186a0e name: 'System object ID' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.2.0 @@ -264,6 +282,7 @@ zabbix_export: tag: Application value: General - + uuid: 89971d6753ce4d98b68a70bf26f4b99e name: 'Operating system' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.1.0 @@ -290,6 +309,7 @@ zabbix_export: value: Inventory triggers: - + uuid: 7b7b6d91b83b43b493bf12844cf03bb0 expression: '(last(/Cisco Catalyst 3750V2-24TS SNMP/system.sw.os,#1)<>last(/Cisco Catalyst 3750V2-24TS SNMP/system.sw.os,#2))=1 and length(last(/Cisco Catalyst 3750V2-24TS SNMP/system.sw.os))>0' recovery_mode: NONE name: 'Operating system description has changed' @@ -301,6 +321,7 @@ zabbix_export: name: 'System name has changed (new name: {ITEM.VALUE})' expression: '(last(/Cisco Catalyst 3750V2-24TS SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-24TS SNMP/system.name,#2))=1 and length(last(/Cisco Catalyst 3750V2-24TS SNMP/system.name))>0' - + uuid: ecc18617c57a44bb96a565f450d569ac name: Uptime type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.3.0 @@ -322,12 +343,14 @@ zabbix_export: value: Status triggers: - + uuid: 86484c0d62e94532af4202267369f8bf expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/system.uptime)<10m' name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING description: 'Uptime is less than 10 minutes' manual_close: 'YES' - + uuid: 0951ddc53a2847b8ba816a5e4de9da2f name: 'SNMP agent availability' type: INTERNAL key: 'zabbix[host,snmp,available]' @@ -340,6 +363,7 @@ zabbix_export: value: Status triggers: - + uuid: 71e158fccd3145f18b4e7f45f5c8d599 expression: 'max(/Cisco Catalyst 3750V2-24TS SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' @@ -347,6 +371,7 @@ zabbix_export: description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.' discovery_rules: - + uuid: a525aec08c6945fda4cad224232825a9 name: 'CPU discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.109.1.1.1.1.5]' @@ -360,6 +385,7 @@ zabbix_export: In case of a single CPU, cpmCPUTotalTable has only one entry. item_prototypes: - + uuid: a912b6f023a64087a99827f9c3cd8ceb name: '#{#SNMPINDEX}: CPU utilization' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.109.1.1.1.1.8.{#SNMPINDEX}' @@ -379,6 +405,7 @@ zabbix_export: value: CPU trigger_prototypes: - + uuid: 62946e7958cf4bdc93505d8de679e567 expression: 'min(/Cisco Catalyst 3750V2-24TS SNMP/system.cpu.util[{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}' name: '#{#SNMPINDEX}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)' opdata: 'Current utilization: {ITEM.LASTVALUE1}' @@ -386,6 +413,7 @@ zabbix_export: description: 'CPU utilization is too high. The system might be slow to respond.' graph_prototypes: - + uuid: e032e542ed064edc8a5b5a297a0f4839 name: '#{#SNMPINDEX}: CPU utilization' ymin_type_1: FIXED ymax_type_1: FIXED @@ -397,6 +425,7 @@ zabbix_export: host: 'Cisco Catalyst 3750V2-24TS SNMP' key: 'system.cpu.util[{#SNMPINDEX}]' - + uuid: 777db6085eed46dbaef83c05049a8d4b name: 'Entity Serial Numbers discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#ENT_CLASS},1.3.6.1.2.1.47.1.1.1.1.5,{#ENT_NAME},1.3.6.1.2.1.47.1.1.1.1.7,{#ENT_SN},1.3.6.1.2.1.47.1.1.1.1.11]' @@ -415,6 +444,7 @@ zabbix_export: formulaid: A item_prototypes: - + uuid: a7b5453459d24368943dd3394fca3d8f name: '{#ENT_NAME}: Hardware serial number' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.47.1.1.1.1.11.{#SNMPINDEX}' @@ -437,11 +467,13 @@ zabbix_export: value: Inventory trigger_prototypes: - + uuid: 63846328cb644b7fb01df6ee4858f3a8 expression: '(last(/Cisco Catalyst 3750V2-24TS SNMP/system.hw.serialnumber[{#SNMPINDEX}],#1)<>last(/Cisco Catalyst 3750V2-24TS SNMP/system.hw.serialnumber[{#SNMPINDEX}],#2))=1 and length(last(/Cisco Catalyst 3750V2-24TS SNMP/system.hw.serialnumber[{#SNMPINDEX}]))>0' name: '{#ENT_NAME}: Device has been replaced (new serial number received)' priority: INFO description: 'Device serial number has changed. Ack to close' - + uuid: c204b466541d475c959d2613a848f03a name: 'FAN discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.4.1.2]' @@ -450,6 +482,7 @@ zabbix_export: description: 'The table of fan status maintained by the environmental monitor.' item_prototypes: - + uuid: 889b225dd7a84e4a9bce92d7138a6615 name: '{#SNMPVALUE}: Fan status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.13.1.4.1.3.{#SNMPINDEX}' @@ -466,12 +499,14 @@ zabbix_export: value: Fans trigger_prototypes: - + uuid: f299241a1a3c4fde965b3a2b6a3b31d6 expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.fan.status[{#SNMPINDEX}])=4' name: '{#SNMPVALUE}: Fan is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the fan unit' - + uuid: a4021a6d44fb439fa04b160b7cea2bca expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.fan.status[{#SNMPINDEX}])=2' name: '{#SNMPVALUE}: Fan is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' @@ -482,6 +517,7 @@ zabbix_export: name: '{#SNMPVALUE}: Fan is in critical state' expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.fan.status[{#SNMPINDEX}])=4' - + uuid: bcde2f961af64c0eb27ec663577c60e1 name: 'Memory discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.48.1.1.1.2]' @@ -492,6 +528,7 @@ zabbix_export: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html item_prototypes: - + uuid: 3c9040a8de7048baaa169b35f596a145 name: '{#SNMPVALUE}: Free memory' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.48.1.1.1.6.{#SNMPINDEX}' @@ -508,6 +545,7 @@ zabbix_export: tag: Application value: Memory - + uuid: e48d2527e378472ab060592a6b303484 name: '{#SNMPVALUE}: Used memory' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.48.1.1.1.5.{#SNMPINDEX}' @@ -524,6 +562,7 @@ zabbix_export: tag: Application value: Memory - + uuid: c4b89f27f4534408a7fbe72110ce86de name: '{#SNMPVALUE}: Memory utilization' type: CALCULATED key: 'vm.memory.util[{#SNMPINDEX}]' @@ -538,12 +577,14 @@ zabbix_export: value: Memory trigger_prototypes: - + uuid: e9dabd93ad8d4a80874126e8f7ccb7bd expression: 'min(/Cisco Catalyst 3750V2-24TS SNMP/vm.memory.util[{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}' name: '{#SNMPVALUE}: High memory utilization ( >{$MEMORY.UTIL.MAX}% for 5m)' priority: AVERAGE description: 'The system is running out of free memory.' graph_prototypes: - + uuid: 25de5d0bebc34c5d9bdf8e181c53588c name: '{#SNMPVALUE}: Memory utilization' ymin_type_1: FIXED ymax_type_1: FIXED @@ -555,6 +596,7 @@ zabbix_export: host: 'Cisco Catalyst 3750V2-24TS SNMP' key: 'vm.memory.util[{#SNMPINDEX}]' - + uuid: ce14cdd4669c4e8bb7b2badbe071f2d9 name: 'Network interfaces discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#IFTYPE},1.3.6.1.2.1.2.2.1.3]' @@ -620,6 +662,7 @@ zabbix_export: description: 'Discovering interfaces from IF-MIB.' item_prototypes: - + uuid: c8d390c0ef1544a08d6a6974d49f17ad name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}' @@ -642,6 +685,7 @@ zabbix_export: tag: Application value: 'Interface {#IFNAME}({#IFALIAS})' - + uuid: 02a607faaaf0494097e25a81d850d646 name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}' @@ -661,6 +705,7 @@ zabbix_export: value: 'Interface {#IFNAME}({#IFALIAS})' trigger_prototypes: - + uuid: a560bb28af7c455ca0c3114e5a894771 expression: 'min(/Cisco Catalyst 3750V2-24TS SNMP/net.if.in.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco Catalyst 3750V2-24TS SNMP/net.if.in.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8' @@ -673,6 +718,7 @@ zabbix_export: name: 'Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.status[{#SNMPINDEX}])=2)' - + uuid: 8b26f84549f14a91935b85b133e8b85b name: 'Interface {#IFNAME}({#IFALIAS}): Bits received' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}' @@ -696,6 +742,7 @@ zabbix_export: tag: Application value: 'Interface {#IFNAME}({#IFALIAS})' - + uuid: 6afb99d2489a4e4fa6ed329d3b140e99 name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}' @@ -718,6 +765,7 @@ zabbix_export: tag: Application value: 'Interface {#IFNAME}({#IFALIAS})' - + uuid: b58d6657f5e14788829ff03f04bd1ac9 name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}' @@ -737,6 +785,7 @@ zabbix_export: value: 'Interface {#IFNAME}({#IFALIAS})' trigger_prototypes: - + uuid: 0d990df95c2649468fdf7535b2511427 expression: 'min(/Cisco Catalyst 3750V2-24TS SNMP/net.if.out.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco Catalyst 3750V2-24TS SNMP/net.if.out.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8' @@ -749,6 +798,7 @@ zabbix_export: name: 'Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.status[{#SNMPINDEX}])=2)' - + uuid: fc23b72b6e0c4b0a9d5c9828f25cc43b name: 'Interface {#IFNAME}({#IFALIAS}): Bits sent' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}' @@ -772,6 +822,7 @@ zabbix_export: tag: Application value: 'Interface {#IFNAME}({#IFALIAS})' - + uuid: a69f1d2e284a4d468d7226a68560405f name: 'Interface {#IFNAME}({#IFALIAS}): Speed' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.15.{#SNMPINDEX}' @@ -795,6 +846,7 @@ zabbix_export: tag: Application value: 'Interface {#IFNAME}({#IFALIAS})' - + uuid: 9a2539d5137645cc868d80c6543b2a32 name: 'Interface {#IFNAME}({#IFALIAS}): Operational status' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}' @@ -822,6 +874,7 @@ zabbix_export: value: 'Interface {#IFNAME}({#IFALIAS})' trigger_prototypes: - + uuid: cb577e04f0a94508a10656c5f276d4e0 expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.status[{#SNMPINDEX}])=2)' name: 'Interface {#IFNAME}({#IFALIAS}): Link down' opdata: 'Current state: {ITEM.LASTVALUE1}' @@ -831,6 +884,7 @@ zabbix_export: 1. Can be triggered if operations status is down. 2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down. - + uuid: f286f2bafa3e4d17a74842fff0a86dcf name: 'Interface {#IFNAME}({#IFALIAS}): Interface type' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.3.{#SNMPINDEX}' @@ -854,6 +908,7 @@ zabbix_export: value: 'Interface {#IFNAME}({#IFALIAS})' trigger_prototypes: - + uuid: c4c394badfdc45f2be9b6102035df05e expression: | change(/Cisco Catalyst 3750V2-24TS SNMP/net.if.speed[{#SNMPINDEX}])<0 and last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.speed[{#SNMPINDEX}])>0 and ( @@ -879,6 +934,7 @@ zabbix_export: name: 'Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.status[{#SNMPINDEX}])=2)' - + uuid: 39eba8395e4940bb8b2893561b425772 expression: | (avg(/Cisco Catalyst 3750V2-24TS SNMP/net.if.in[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.speed[{#SNMPINDEX}])) and last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.speed[{#SNMPINDEX}])>0 @@ -893,6 +949,7 @@ zabbix_export: name: 'Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.status[{#SNMPINDEX}])=2)' - + uuid: db3576a9825d4bea9c6252fbcd7bb393 expression: | (avg(/Cisco Catalyst 3750V2-24TS SNMP/net.if.out[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.speed[{#SNMPINDEX}])) and last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.speed[{#SNMPINDEX}])>0 @@ -908,6 +965,7 @@ zabbix_export: expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.status[{#SNMPINDEX}])=2)' graph_prototypes: - + uuid: 6be27bc4e258470bb324ef8f90295e92 name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic' graph_items: - @@ -952,6 +1010,7 @@ zabbix_export: host: 'Cisco Catalyst 3750V2-24TS SNMP' key: 'net.if.in.discards[{#SNMPINDEX}]' - + uuid: d1264fbbd4b547a6874152179ed756d5 name: 'EtherLike discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.2.1.10.7.2.1.19,{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2]' @@ -971,6 +1030,7 @@ zabbix_export: description: 'Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered.' item_prototypes: - + uuid: ab70998b12124fee93168b5e8222512e name: 'Interface {#IFNAME}({#IFALIAS}): Duplex status' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.10.7.2.1.19.{#SNMPINDEX}' @@ -1011,11 +1071,13 @@ zabbix_export: value: 'Interface {#IFNAME}({#IFALIAS})' trigger_prototypes: - + uuid: 45b5778869124558b3265d6d7275c186 expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/net.if.duplex[{#SNMPINDEX}])=2' name: 'Interface {#IFNAME}({#IFALIAS}): In half-duplex mode' priority: WARNING description: 'Please check autonegotiation settings and cabling' - + uuid: 742411a65e7f4b5fafc47e861ab8bd23 name: 'PSU discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.5.1.2]' @@ -1024,6 +1086,7 @@ zabbix_export: description: 'The table of power supply status maintained by the environmental monitor card.' item_prototypes: - + uuid: a3617fa8711146a0bdddd2e721cedb52 name: '{#SNMPVALUE}: Power supply status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.13.1.5.1.3.{#SNMPINDEX}' @@ -1040,12 +1103,14 @@ zabbix_export: value: 'Power supply' trigger_prototypes: - + uuid: 23fc241ca9d6438bb1688c77688fd1ed expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.psu.status[{#SNMPINDEX}])=4' name: '{#SNMPVALUE}: Power supply is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the power supply unit for errors' - + uuid: c6ed26fb555642c9b25564ec13fcf920 expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.psu.status[{#SNMPINDEX}])=2' name: '{#SNMPVALUE}: Power supply is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' @@ -1056,6 +1121,7 @@ zabbix_export: name: '{#SNMPVALUE}: Power supply is in critical state' expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.psu.status[{#SNMPINDEX}])=4' - + uuid: 595c88262f2f48c99d16f22ab7d70aac name: 'Temperature discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.3.1.2]' @@ -1066,6 +1132,7 @@ zabbix_export: maintained by the environmental monitor. item_prototypes: - + uuid: e1636ece86b1427cad01e7223052b526 name: '{#SNMPVALUE}: Temperature status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.13.1.3.1.6.{#SNMPINDEX}' @@ -1083,12 +1150,14 @@ zabbix_export: value: Temperature trigger_prototypes: - + uuid: 1820c365ad55416e995d4d978063e4a1 expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.status[{#SNMPINDEX}])=4' name: '{#SNMPVALUE}: Temperature is in critical state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor state' - + uuid: 0b7e6f3085a0404ebb64c33828c9c920 expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.status[{#SNMPINDEX}])=2' name: '{#SNMPVALUE}: Temperature is in warning state' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -1099,6 +1168,7 @@ zabbix_export: name: '{#SNMPVALUE}: Temperature is in critical state' expression: 'last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.status[{#SNMPINDEX}])=4' - + uuid: 16a4c905660349aaaddf52573916e187 name: '{#SNMPVALUE}: Temperature' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.13.1.3.1.3.{#SNMPINDEX}' @@ -1116,6 +1186,7 @@ zabbix_export: value: Temperature trigger_prototypes: - + uuid: 077d265094ff4ea7a3d2c420b20cb700 expression: 'avg(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' @@ -1124,6 +1195,7 @@ zabbix_export: priority: HIGH description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' - + uuid: eb0a959d5916490c930093b69da191ba expression: 'avg(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3' @@ -1137,6 +1209,7 @@ zabbix_export: expression: 'avg(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' recovery_expression: 'max(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' - + uuid: b7d7399634554f108ca4c2e902b330af expression: 'avg(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'min(/Cisco Catalyst 3750V2-24TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3' @@ -1218,6 +1291,7 @@ zabbix_export: value: '50' valuemaps: - + uuid: fea34445b6cd4847b420d212f9b0201e name: 'CISCO-ENVMON-MIB::CiscoEnvMonState' mappings: - @@ -1239,6 +1313,7 @@ zabbix_export: value: '6' newvalue: notFunctioning - + uuid: 867b0e42f8a24a278ee15476aeadfa0b name: 'EtherLike-MIB::dot3StatsDuplexStatus' mappings: - @@ -1251,6 +1326,7 @@ zabbix_export: value: '3' newvalue: fullDuplex - + uuid: 3534f9f22afe4f98a712a86ce755f491 name: 'IF-MIB::ifOperStatus' mappings: - @@ -1275,6 +1351,7 @@ zabbix_export: value: '7' newvalue: lowerLayerDown - + uuid: 88b99531b08248e8be1fc0a3210acee1 name: 'IF-MIB::ifType' mappings: - @@ -2136,6 +2213,7 @@ zabbix_export: value: '290' newvalue: ghn - + uuid: 653ce2314e6f499b84250048df1314f8 name: 'Service state' mappings: - @@ -2145,6 +2223,7 @@ zabbix_export: value: '1' newvalue: Up - + uuid: 690c4c1545894d049ac8e26e3de7ec9c name: zabbix.host.available mappings: - |