Welcome to mirror list, hosted at ThFree Co, Russian Federation.

github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
Diffstat (limited to 'templates/net/morningstar/morningstar_prostar_pwm_snmp/template_net_morningstar_prostar_pwm_snmp.yaml')
-rw-r--r--templates/net/morningstar/morningstar_prostar_pwm_snmp/template_net_morningstar_prostar_pwm_snmp.yaml321
1 files changed, 281 insertions, 40 deletions
diff --git a/templates/net/morningstar/morningstar_prostar_pwm_snmp/template_net_morningstar_prostar_pwm_snmp.yaml b/templates/net/morningstar/morningstar_prostar_pwm_snmp/template_net_morningstar_prostar_pwm_snmp.yaml
index 7dee3a295c2..8866f789984 100644
--- a/templates/net/morningstar/morningstar_prostar_pwm_snmp/template_net_morningstar_prostar_pwm_snmp.yaml
+++ b/templates/net/morningstar/morningstar_prostar_pwm_snmp/template_net_morningstar_prostar_pwm_snmp.yaml
@@ -1,6 +1,6 @@
zabbix_export:
version: '6.0'
- date: '2021-12-17T06:32:04Z'
+ date: '2022-01-26T09:52:22Z'
groups:
-
uuid: 57b7ae836ca64446ba2c296389c009b7
@@ -14,7 +14,7 @@ zabbix_export:
MIBs used:
PROSTAR-PWM
- Template tooling version used: 0.40
+ Template tooling version used: 0.41
groups:
-
name: Templates/Modules
@@ -37,8 +37,8 @@ zabbix_export:
Modbus address:0x0013
tags:
-
- tag: Application
- value: Array
+ tag: component
+ value: array
-
uuid: a80ad3ace9b14446bc5fd5d6aaa5af87
name: 'Battery: Battery Voltage discovery'
@@ -52,8 +52,14 @@ zabbix_export:
description: 'MIB: PROSTAR-PWM'
tags:
-
- tag: Application
- value: 'Zabbix raw items'
+ tag: component
+ value: battery
+ -
+ tag: component
+ value: discovery
+ -
+ tag: component
+ value: raw
-
uuid: 148008b117c94155ba81600e3050ab25
name: 'Battery: Charge Current'
@@ -72,8 +78,8 @@ zabbix_export:
Modbus address:0x0011
tags:
-
- tag: Application
- value: Battery
+ tag: component
+ value: battery
-
uuid: a7ae2d3b911e4bb5a7eeb770470245a5
name: 'Battery: Charge State'
@@ -105,8 +111,8 @@ zabbix_export:
- 1h
tags:
-
- tag: Application
- value: Battery
+ tag: component
+ value: battery
triggers:
-
uuid: f12fc2c1a7a142a287304c18bafa1181
@@ -114,6 +120,10 @@ zabbix_export:
name: 'Battery: Device charge in critical state'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: adf8cf02aa1e42fa84e1f11ddae4df01
expression: 'last(/Morningstar ProStar PWM SNMP/charge.state[chargeState.0])={$CHARGE.STATE.WARN}'
@@ -124,6 +134,10 @@ zabbix_export:
-
name: 'Battery: Device charge in critical state'
expression: 'last(/Morningstar ProStar PWM SNMP/charge.state[chargeState.0])={$CHARGE.STATE.CRIT}'
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 8acd2e7944694a828cf9b739b75513d9
name: 'Counter: Charge Amp-hours'
@@ -147,8 +161,8 @@ zabbix_export:
- '0.1'
tags:
-
- tag: Application
- value: Counter
+ tag: component
+ value: counter
-
uuid: 0e7124df3f2b4298b1a13576d0b2d5e7
name: 'Counter: Charge KW-hours'
@@ -167,8 +181,8 @@ zabbix_export:
Modbus address:0x002A
tags:
-
- tag: Application
- value: Counter
+ tag: component
+ value: counter
-
uuid: 104a7db1c27d40b3bbee506f7f922393
name: 'Counter: Load Amp-hours'
@@ -192,8 +206,8 @@ zabbix_export:
- '0.1'
tags:
-
- tag: Application
- value: Counter
+ tag: component
+ value: counter
-
uuid: dcade8607cf142a2b88333f9880448fc
name: 'Load: Current'
@@ -212,8 +226,8 @@ zabbix_export:
Modbus address:0x0016
tags:
-
- tag: Application
- value: Load
+ tag: component
+ value: load
-
uuid: 14b3ca3869374f54a467e5e9017f918a
name: 'Load: State'
@@ -245,8 +259,8 @@ zabbix_export:
- 1h
tags:
-
- tag: Application
- value: Load
+ tag: component
+ value: load
triggers:
-
uuid: 7a8bf4420b6b48ab8a5bc999eecae760
@@ -254,6 +268,10 @@ zabbix_export:
name: 'Load: Device load in critical state'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 5152f9cd4ee34be485f3cb0a0f60afd5
expression: 'last(/Morningstar ProStar PWM SNMP/load.state[loadState.0])={$LOAD.STATE.WARN:"lvdWarning"} or last(/Morningstar ProStar PWM SNMP/load.state[loadState.0])={$LOAD.STATE.WARN:"override"}'
@@ -264,6 +282,10 @@ zabbix_export:
-
name: 'Load: Device load in critical state'
expression: 'last(/Morningstar ProStar PWM SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar ProStar PWM SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"fault"}'
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: cccc0976a62b47b1a558d521704c125d
name: 'Load: Voltage'
@@ -282,8 +304,8 @@ zabbix_export:
Modbus address:0x0014
tags:
-
- tag: Application
- value: Load
+ tag: component
+ value: load
-
uuid: 7c1c1e03425c4b4bb176cf45458b916a
name: 'Status: Alarms'
@@ -344,8 +366,8 @@ zabbix_export:
return result.length ? result.join('\n') : 'No alarms';
tags:
-
- tag: Application
- value: Status
+ tag: component
+ value: status
triggers:
-
uuid: 67fd46f034c3486e9af3cabfc5dc8056
@@ -353,42 +375,70 @@ zabbix_export:
name: 'Status: Device has "arrayCurrentOffset" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 31cc0b05b83045de80a7d07f26545010
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","batterySenseDisconnected")=2'
name: 'Status: Device has "batterySenseDisconnected" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 9e498d21bc7f4ca1937f1628f4b1ea55
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","batterySenseOutOfRange")=2'
name: 'Status: Device has "batterySenseOutOfRange" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 8a09c7609f9a45cea5b217757a7d2e5e
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","batteryTempOutOfRange")=2'
name: 'Status: Device has "batteryTempOutOfRange" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: b173b8ca12f8464aae6476009b4c89e8
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","controllerReset")=2'
name: 'Status: Device has "controllerReset" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: cdbac88810ff49caa35771e661d8b312
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","currentLimit")=2'
name: 'Status: Device has "currentLimit" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 7758388df28d4540ba393f4423fef00a
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","currentMeasurementError")=2'
name: 'Status: Device has "currentMeasurementError" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: a56fef1f61c44ba884ec448b0d306c1d
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","eepromAccessFailure")=2'
@@ -401,84 +451,140 @@ zabbix_export:
name: 'Status: Device has "fp10SupplyOutOfRange" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: c252c82aff2a4ac680965115cb2fab64
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempLimit")=2'
name: 'Status: Device has "heatsinkTempLimit" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 5b93a0a09a62481d8096ec743c2ceaff
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorOpen")=2'
name: 'Status: Device has "heatsinkTempSensorOpen" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: f28e5143a238470ba93c1345c814f87d
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorShorted")=2'
name: 'Status: Device has "heatsinkTempSensorShorted" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 75c84ef378984fca854b34a8ef79668c
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","hightInputVoltageLimit")=2'
name: 'Status: Device has "hightInputVoltageLimit" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 5c1551f7e2be40e0b8b50ed263f8e293
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","loadCurrentOffset")=2'
name: 'Status: Device has "loadCurrentOffset" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 665117c5b9b64ea09a1d661e9c40fc43
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","loadLvd")=2'
name: 'Status: Device has "loadLvd" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: b89c002c859c419ea748b43d575e9e27
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","logTimeout")=2'
name: 'Status: Device has "logTimeout" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 17f51e7b248b4e63934e8b529b85b2ef
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","mosfetOpen")=2'
name: 'Status: Device has "mosfetOpen" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 75e23772250741d0b1fc1ddff2a72ef6
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","p12SupplyOutOfRange")=2'
name: 'Status: Device has "p12SupplyOutOfRange" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: fc374c9ac9fa4f979fbff9f7c7d83565
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","p33SupplyOutOfRange")=2'
name: 'Status: Device has "p33SupplyOutOfRange" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: fbec2a1fdbe54d8da352471acf67bad1
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","rtsDisconnected")=2'
name: 'Status: Device has "rtsDisconnected" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 915da6e7b1cd410da9a6c68e3b4abd85
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","rtsShorted")=2'
name: 'Status: Device has "rtsShorted" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: e8bf2213a5444e2c9923b6f093d43f75
expression: 'count(/Morningstar ProStar PWM SNMP/status.alarms[alarms.0],#3,"like","uncalibrated")=2'
name: 'Status: Device has "uncalibrated" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 2517d96e51c14372a0336c9a6ed5d078
name: 'Status: Array Faults'
@@ -529,8 +635,8 @@ zabbix_export:
return result.length ? result.join('\n') : 'No faults';
tags:
-
- tag: Application
- value: Status
+ tag: component
+ value: status
triggers:
-
uuid: b2ff69793e124031a79a668b03678fac
@@ -538,78 +644,130 @@ zabbix_export:
name: 'Status: Device has "arrayHvd" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: a4ca36ccaa9d45ceb79303afef1c49f0
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","batteryHvd")=2'
name: 'Status: Device has "batteryHvd" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: f4d1120afb13456b9d45f8795dbc30b7
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","batteryLowVoltageDisconnect")=2'
name: 'Status: Device has "batteryLowVoltageDisconnect" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 9e5f2c575945458ea8a39f33cb23b833
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","customSettingsEdit")=2'
name: 'Status: Device has "customSettingsEdit" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: fd904f4469324784ac2c469e64069f94
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","dipSwitchChanged")=2'
name: 'Status: Device has "dipSwitchChanged" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 62076ce0967049c8bde39f71afcb85d9
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","localTempSensorDamaged")=2'
name: 'Status: Device has "localTempSensorDamaged" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: ea8487afe1c14bc08f3d9fd7f75d208f
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","mosfetSShorted")=2'
name: 'Status: Device has "mosfetSShorted" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: b0bb139541ae493bafc40dac9074d898
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","overcurrent")=2'
name: 'Status: Device has "overcurrent" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 8af94d7ff1a84e18b10122b0e3743d45
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","p3Fault")=2'
name: 'Status: Device has "p3Fault" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: b41cb2e05acb40f59efa50a25f66cd62
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","rtsNoLongerValid")=2'
name: 'Status: Device has "rtsNoLongerValid" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: d99c3f126c7e480cb4fcc705349eb61d
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","rtsShorted")=2'
name: 'Status: Device has "rtsShorted" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 711b28f19cb74c0faeef73263ca1fb8f
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","slaveTimeout")=2'
name: 'Status: Device has "slaveTimeout" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: e4a261d750d546c7b5d5067dd9a0ec25
expression: 'count(/Morningstar ProStar PWM SNMP/status.array_faults[arrayFaults.0],#3,"like","software")=2'
name: 'Status: Device has "software" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 1cd47d04af104cb9ab1cd7dc745a6aea
name: 'Status: Load Faults'
@@ -656,8 +814,8 @@ zabbix_export:
return result.length ? result.join('\n') : 'No faults';
tags:
-
- tag: Application
- value: Status
+ tag: component
+ value: status
triggers:
-
uuid: 99ab5f0d3014459a8cd7d137d3a1f688
@@ -665,54 +823,90 @@ zabbix_export:
name: 'Status: Device has "customSettingsEdit" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 77752192092f4f1caceef19c3c164b72
expression: 'count(/Morningstar ProStar PWM SNMP/status.load_faults[loadFaults.0],#3,"like","dipSwitchChanged")=2'
name: 'Status: Device has "dipSwitchChanged" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: d2e55501d89844aeb47f7887a11754a9
expression: 'count(/Morningstar ProStar PWM SNMP/status.load_faults[loadFaults.0],#3,"like","externalShortCircuit")=2'
name: 'Status: Device has "externalShortCircuit" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: a6548502cfc4406098ba3129af8efcb5
expression: 'count(/Morningstar ProStar PWM SNMP/status.load_faults[loadFaults.0],#3,"like","highTempDisconnect")=2'
name: 'Status: Device has "highTempDisconnect" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 6e8f0127bc7b42dea9d867ab174f458c
expression: 'count(/Morningstar ProStar PWM SNMP/status.load_faults[loadFaults.0],#3,"like","loadHvd")=2'
name: 'Status: Device has "loadHvd" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 2a303d4712e244a9b051fb1b0247fac5
expression: 'count(/Morningstar ProStar PWM SNMP/status.load_faults[loadFaults.0],#3,"like","mosfetShorted")=2'
name: 'Status: Device has "mosfetShorted" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 5720e2e15e5f42099fd7de361f62c99a
expression: 'count(/Morningstar ProStar PWM SNMP/status.load_faults[loadFaults.0],#3,"like","overcurrent")=2'
name: 'Status: Device has "overcurrent" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 2f522d50a8124ed2a8af4d7b6417c31c
expression: 'count(/Morningstar ProStar PWM SNMP/status.load_faults[loadFaults.0],#3,"like","p3Fault")=2'
name: 'Status: Device has "p3Fault" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: e75abe852b9c4e1d91a1f8f83622ef64
expression: 'count(/Morningstar ProStar PWM SNMP/status.load_faults[loadFaults.0],#3,"like","software")=2'
name: 'Status: Device has "software" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 42f6a75d923d4262b37d85c4f7d1d322
name: 'Status: Uptime'
@@ -729,8 +923,8 @@ zabbix_export:
- '0.01'
tags:
-
- tag: Application
- value: Status
+ tag: component
+ value: status
triggers:
-
uuid: dea364bf454746bca6be38d7e0759d06
@@ -739,6 +933,10 @@ zabbix_export:
priority: INFO
description: 'Uptime is less than 10 minutes'
manual_close: 'YES'
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 16c1444a745a47e59fd22bd1a64baef3
expression: 'nodata(/Morningstar ProStar PWM SNMP/status.uptime,5m)=1'
@@ -746,6 +944,10 @@ zabbix_export:
priority: WARNING
description: 'Zabbix has not received data for items for the last 5 minutes'
manual_close: 'YES'
+ tags:
+ -
+ tag: scope
+ value: availability
-
uuid: f4b7bfb000754a17b4719863d3755519
name: 'Battery: Target Voltage'
@@ -769,8 +971,8 @@ zabbix_export:
- 1h
tags:
-
- tag: Application
- value: Battery
+ tag: component
+ value: battery
-
uuid: 13d3479a7b5940b5a53d5f13bea9e2d1
name: 'Temperature: Ambient'
@@ -789,8 +991,8 @@ zabbix_export:
Modbus address:0x001C
tags:
-
- tag: Application
- value: Temperature
+ tag: component
+ value: temperature
-
uuid: 39763f7fccd94aefb720a34871c0962b
name: 'Temperature: Battery'
@@ -809,8 +1011,8 @@ zabbix_export:
Modbus address:0x001B
tags:
-
- tag: Application
- value: Temperature
+ tag: component
+ value: temperature
triggers:
-
uuid: 46eb3a0e80294a4db8324d56337ed712
@@ -818,12 +1020,20 @@ zabbix_export:
name: 'Temperature: Critically high battery temperature (over {$BATTERY.TEMP.MAX.CRIT}C for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: c3f3ba5b2cab4481bb62fa8527554e96
expression: 'max(/Morningstar ProStar PWM SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}'
name: 'Temperature: Critically low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 80aaf1de029b4d6eadce9f2a946f6dde
expression: 'min(/Morningstar ProStar PWM SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.WARN}'
@@ -834,6 +1044,10 @@ zabbix_export:
-
name: 'Temperature: Critically high battery temperature (over {$BATTERY.TEMP.MAX.CRIT}C for 5m)'
expression: 'min(/Morningstar ProStar PWM SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}'
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: cf1db336ea124f9a9fd6eb367f93f0e8
expression: 'max(/Morningstar ProStar PWM SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.WARN}'
@@ -844,6 +1058,10 @@ zabbix_export:
-
name: 'Temperature: Critically low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)'
expression: 'max(/Morningstar ProStar PWM SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}'
+ tags:
+ -
+ tag: scope
+ value: notice
-
uuid: 1d13bd3ea24a4fcab3cd5b7586e6033a
name: 'Temperature: Heatsink'
@@ -862,8 +1080,8 @@ zabbix_export:
Modbus address:0x001A
tags:
-
- tag: Application
- value: Temperature
+ tag: component
+ value: temperature
discovery_rules:
-
uuid: 17148797def9484ba26b0afdcc44bfd5
@@ -888,8 +1106,8 @@ zabbix_export:
Modbus address:0x0021
tags:
-
- tag: Application
- value: Battery
+ tag: component
+ value: battery
trigger_prototypes:
-
uuid: e89cf2b8066840c2876642f0d8db1edd
@@ -897,12 +1115,20 @@ zabbix_export:
name: 'Battery: Critically high battery voltage (over {#VOLTAGE.MAX.CRIT}V for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: capacity
-
uuid: 8356aba9afb242b09902873a5f0e1d47
expression: 'max(/Morningstar ProStar PWM SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}'
name: 'Battery: Critically low battery voltage (below {#VOLTAGE.MIN.CRIT}V for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
+ tags:
+ -
+ tag: scope
+ value: capacity
-
uuid: 77f130af976c43edb8c823de5cbd57b2
expression: 'min(/Morningstar ProStar PWM SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.WARN}'
@@ -913,6 +1139,10 @@ zabbix_export:
-
name: 'Battery: Critically high battery voltage (over {#VOLTAGE.MAX.CRIT}V for 5m)'
expression: 'min(/Morningstar ProStar PWM SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}'
+ tags:
+ -
+ tag: scope
+ value: capacity
-
uuid: 6c288c8b28db4f8e95c8ad2aa8b838ef
expression: 'max(/Morningstar ProStar PWM SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.WARN}'
@@ -923,6 +1153,10 @@ zabbix_export:
-
name: 'Battery: Critically low battery voltage (below {#VOLTAGE.MIN.CRIT}V for 5m)'
expression: 'max(/Morningstar ProStar PWM SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}'
+ tags:
+ -
+ tag: scope
+ value: capacity
graph_prototypes:
-
uuid: 8ecd4f88627a4dadb132fdbb6d911b6b
@@ -969,6 +1203,13 @@ zabbix_export:
}
return JSON.stringify(result);
+ tags:
+ -
+ tag: class
+ value: power
+ -
+ tag: target
+ value: morningstar
macros:
-
macro: '{$BATTERY.TEMP.MAX.CRIT}'