diff options
Diffstat (limited to 'templates/net/morningstar_snmp/sunsaver_mppt_snmp/sunsaver_mppt_snmp.yaml')
-rw-r--r-- | templates/net/morningstar_snmp/sunsaver_mppt_snmp/sunsaver_mppt_snmp.yaml | 77 |
1 files changed, 76 insertions, 1 deletions
diff --git a/templates/net/morningstar_snmp/sunsaver_mppt_snmp/sunsaver_mppt_snmp.yaml b/templates/net/morningstar_snmp/sunsaver_mppt_snmp/sunsaver_mppt_snmp.yaml index a2f8434eddb..3feb1ca76fa 100644 --- a/templates/net/morningstar_snmp/sunsaver_mppt_snmp/sunsaver_mppt_snmp.yaml +++ b/templates/net/morningstar_snmp/sunsaver_mppt_snmp/sunsaver_mppt_snmp.yaml @@ -1,11 +1,13 @@ zabbix_export: version: '5.4' - date: '2021-05-09T00:00:00Z' + date: '2021-05-10T19:41:15Z' groups: - + uuid: 57b7ae836ca64446ba2c296389c009b7 name: Templates/Modules templates: - + uuid: f1336fd88ab0415a9c02892a71e50032 template: 'Morningstar SunSaver MPPT SNMP' name: 'Morningstar SunSaver MPPT SNMP' description: | @@ -18,6 +20,7 @@ zabbix_export: name: Templates/Modules items: - + uuid: 9836b1fc81b84a44b2a708291bd5bf1a name: 'Array: Sweep Pmax' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.57.0 @@ -47,6 +50,7 @@ zabbix_export: tag: Application value: Array - + uuid: 0842746ca41c44128a575113307259e2 name: 'Array: Sweep Vmp' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.56.0 @@ -76,6 +80,7 @@ zabbix_export: tag: Application value: Array - + uuid: 0e3371208513416ab1b9afdf2c3b2c08 name: 'Array: Sweep Voc' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.58.0 @@ -105,6 +110,7 @@ zabbix_export: tag: Application value: Array - + uuid: da1f347b28dd4fbeb123f228adefb0ed name: 'Array: Voltage' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.31.0 @@ -134,6 +140,7 @@ zabbix_export: tag: Application value: Array - + uuid: f8803a1390b745f08673d4ea998548a9 name: 'Battery: Battery Voltage discovery' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.30.0 @@ -153,6 +160,7 @@ zabbix_export: tag: Application value: 'Zabbix raw items' - + uuid: a36313ef0933403788a42de8a62b4838 name: 'Battery: Charge Current' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.33.0 @@ -182,6 +190,7 @@ zabbix_export: tag: Application value: Battery - + uuid: 4da765c8e26540c190ea07be08b87abc name: 'Battery: Charge State' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.39.0 @@ -215,11 +224,13 @@ zabbix_export: value: Battery triggers: - + uuid: 0362139c66f4464db8c022b9ffce5502 expression: 'last(/Morningstar SunSaver MPPT SNMP/charge.state[chargeState.0])={$CHARGE.STATE.CRIT}' name: 'Battery: Device charge in critical state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: d5439cee53b148ecb4186286c4e93ada expression: 'last(/Morningstar SunSaver MPPT SNMP/charge.state[chargeState.0])={$CHARGE.STATE.WARN}' name: 'Battery: Device charge in warning state' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -229,6 +240,7 @@ zabbix_export: name: 'Battery: Device charge in critical state' expression: 'last(/Morningstar SunSaver MPPT SNMP/charge.state[chargeState.0])={$CHARGE.STATE.CRIT}' - + uuid: 149545b9154044e3af27b4e9ad809c0e name: 'Counter: Charge Amp-hours' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.43.0 @@ -253,6 +265,7 @@ zabbix_export: tag: Application value: Counter - + uuid: f6d0f89c747b4418ad34c32b5ac9a5b9 name: 'Counter: Charge KW-hours' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.45.0 @@ -265,6 +278,7 @@ zabbix_export: tag: Application value: Counter - + uuid: 28e679eace174d289ca5ccf90f3b9150 name: 'Counter: Load Amp-hours' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.49.0 @@ -289,6 +303,7 @@ zabbix_export: tag: Application value: Counter - + uuid: 6491ee507d9a4c099852d33e57df48a9 name: 'Load: Current' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.34.0 @@ -318,6 +333,7 @@ zabbix_export: tag: Application value: Load - + uuid: c5dfef2deee445ec88e2d63dbfbbaf68 name: 'Load: State' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.46.0 @@ -351,11 +367,13 @@ zabbix_export: value: Load triggers: - + uuid: bbd3a89b012a40daa646ec7113d43e43 expression: 'last(/Morningstar SunSaver MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar SunSaver MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"fault"}' name: 'Load: Device load in critical state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 8f6967c1b577431c995a3c13f8cdb1c1 expression: 'last(/Morningstar SunSaver MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.WARN:"lvdWarning"} or last(/Morningstar SunSaver MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.WARN:"override"}' name: 'Load: Device load in warning state' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -365,6 +383,7 @@ zabbix_export: name: 'Load: Device load in critical state' expression: 'last(/Morningstar SunSaver MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar SunSaver MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"fault"}' - + uuid: a9ca69fcedbb4524a8eb4b92b975008e name: 'Load: Voltage' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.32.0 @@ -394,6 +413,7 @@ zabbix_export: tag: Application value: Load - + uuid: 91f2c1893b594e808032eb0140247d7a name: 'Status: Alarms' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.52.0 @@ -451,71 +471,85 @@ zabbix_export: value: Status triggers: - + uuid: 47c0f032d78a4906ab3fb52520f15591 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","currentLimit")=2' name: 'Status: Device has "currentLimit" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: 39070380e3484abbabf763c63f38a358 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","currentOffset")=2' name: 'Status: Device has "currentOffset" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: a3e45273d08d4841bdf52c0df0c88a85 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorOpen")=2' name: 'Status: Device has "heatsinkTempSensorOpen" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: e8d8de46d71342dfb1bb85dda214826a expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorShorted")=2' name: 'Status: Device has "heatsinkTempSensorShorted" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: 6fc0f510ffcb42419d0bc1ad735b0265 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","highVaCurrentLimit")=2' name: 'Status: Device has "highVaCurrentLimit" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: 08e15aef1a9c44feb60fcd5f6f523bf7 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","mosfetSOpen")=2' name: 'Status: Device has "mosfetSOpen" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: f9003326837946a1a0271c2bd76565af expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","p12VoltageReferenceOff")=2' name: 'Status: Device has "p12VoltageReferenceOff" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: 055924cada5b4f629204b813a43b2258 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","rtsDisconnected")=2' name: 'Status: Device has "rtsDisconnected" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: 0ef0fa63dee84fcfafee5146a37f2f0b expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","rtsMiswire")=2' name: 'Status: Device has "rtsMiswire" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: 0a1827675b3d4b7ab09da471cb2a7b0e expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","rtsShorted")=2' name: 'Status: Device has "rtsShorted" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: 8c6a7527eda644ed8c79d7eeda634753 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","sspptHot")=2' name: 'Status: Device has "sspptHot" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: 90f796488bf04008a19823ad95ae574d expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","systemMiswire")=2' name: 'Status: Device has "systemMiswire" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: 38b3af5550ba4734ba35d8c7d09b5ec7 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.alarms[alarms.0],#3,"like","uncalibrated")=2' name: 'Status: Device has "uncalibrated" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING - + uuid: f44756455697466cb905aa6ae4d0220d name: 'Status: Array Faults' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.40.0 @@ -564,51 +598,61 @@ zabbix_export: value: Status triggers: - + uuid: 7a107f9923c84ccd97e7a46d163109bb expression: 'count(/Morningstar SunSaver MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","arrayHvd")=2' name: 'Status: Device has "arrayHvd" array faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: ad3c2ad08fa14bffa7f3aaea203da00f expression: 'count(/Morningstar SunSaver MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","batteryHvd")=2' name: 'Status: Device has "batteryHvd" array faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: f7f11c0b7390489d80954285275ea46c expression: 'count(/Morningstar SunSaver MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","customSettingsEdit")=2' name: 'Status: Device has "customSettingsEdit" array faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 456ce09e92a446a388c3d8a440b08852 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","localTempSensorDamaged")=2' name: 'Status: Device has "localTempSensorDamaged" array faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: aac39c8bc01c4d6d9f93208934e57981 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","mosfetSShorted")=2' name: 'Status: Device has "mosfetSShorted" array faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 70d1548951e144be915d012610cd6fe4 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","overcurrent")=2' name: 'Status: Device has "overcurrent" array faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 288ff71737154bcc9ad4175937d4c3c4 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","rtsNoLongerValid")=2' name: 'Status: Device has "rtsNoLongerValid" array faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: d7a47ad9ecdf40bfa989ee244a55cfbf expression: 'count(/Morningstar SunSaver MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","rtsShorted")=2' name: 'Status: Device has "rtsShorted" array faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 1794d566eb014fc386d513ee38b7eed1 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","softwareFault")=2' name: 'Status: Device has "softwareFault" array faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 24762b0c264745548150a4bd5913156f name: 'Status: Load Faults' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.47.0 @@ -656,46 +700,55 @@ zabbix_export: value: Status triggers: - + uuid: 027b2ae4a0064bbeaf3222770f6ec711 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","customSettingsEdit")=2' name: 'Status: Device has "customSettingsEdit" load faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 338edbed121c48aba4a26713825c7b67 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","externalShortCircuit")=2' name: 'Status: Device has "externalShortCircuit" load faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 8040ee4dbe1242fdaab9e56e191e7180 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","highTempDisconnect")=2' name: 'Status: Device has "highTempDisconnect" load faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 96e4bfb0c2bf40cc8c7b04a3edff0c4c expression: 'count(/Morningstar SunSaver MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","loadHvd")=2' name: 'Status: Device has "loadHvd" load faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 83bfd2db681940d58ce2787d76eeeaa8 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","mosfetShorted")=2' name: 'Status: Device has "mosfetShorted" load faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: dedf0e3dbf474e72b81b1d0cbb35f867 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","overcurrent")=2' name: 'Status: Device has "overcurrent" load faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: d4ace4734e774a4e984d7b60504f1026 expression: 'count(/Morningstar SunSaver MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","software")=2' name: 'Status: Device has "software" load faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: ec7c053a94a248408224c9f61632fb5c expression: 'count(/Morningstar SunSaver MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","unknownLoadFault")=2' name: 'Status: Device has "unknownLoadFault" load faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 63512390f2a04885bf8d0e19653a72b1 name: 'Status: Uptime' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.3.0 @@ -714,18 +767,21 @@ zabbix_export: value: Status triggers: - + uuid: fd5dcb256d4547da9c432c1b9c01b0ae expression: 'last(/Morningstar SunSaver MPPT SNMP/status.uptime)<10m' name: 'Status: Device has been restarted (uptime < 10m)' priority: INFO description: 'Uptime is less than 10 minutes' manual_close: 'YES' - + uuid: 8f3d2977a5c544248af8f6b4e4b15428 expression: 'nodata(/Morningstar SunSaver MPPT SNMP/status.uptime,5m)=1' name: 'Status: Failed to fetch data (or no data for 5m)' priority: WARNING description: 'Zabbix has not received data for items for the last 5 minutes' manual_close: 'YES' - + uuid: 52afa576b83b49e69ec8d379fbc42965 name: 'Battery: Target Voltage' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.42.0 @@ -755,6 +811,7 @@ zabbix_export: tag: Application value: Battery - + uuid: 430cf6fcb9b74943a8ca7f1d9d06fa56 name: 'Temperature: Ambient' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.37.0 @@ -774,6 +831,7 @@ zabbix_export: tag: Application value: Temperature - + uuid: 157faa85ae244950b4a114b95bad6d50 name: 'Temperature: Battery' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.36.0 @@ -794,16 +852,19 @@ zabbix_export: value: Temperature triggers: - + uuid: a4d773e1cf1c4566bc6e3f5cfd113a5a expression: 'min(/Morningstar SunSaver MPPT SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}' name: 'Temperature: Critically high battery temperature (over {$BATTERY.TEMP.MAX.CRIT}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 92d2b86e30e4404bbd7901ff784b3de5 expression: 'max(/Morningstar SunSaver MPPT SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}' name: 'Temperature: Critically low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 0b1682a5aab042b2a24d47916886febb expression: 'min(/Morningstar SunSaver MPPT SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.WARN}' name: 'Temperature: High battery temperature (over {$BATTERY.TEMP.MAX.WARN}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -813,6 +874,7 @@ zabbix_export: name: 'Temperature: Critically high battery temperature (over {$BATTERY.TEMP.MAX.CRIT}C for 5m)' expression: 'min(/Morningstar SunSaver MPPT SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}' - + uuid: f56a8231c34b498faa3007df93238d12 expression: 'max(/Morningstar SunSaver MPPT SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.WARN}' name: 'Temperature: Low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -822,6 +884,7 @@ zabbix_export: name: 'Temperature: Critically low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)' expression: 'max(/Morningstar SunSaver MPPT SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}' - + uuid: 5f238fe557a7412cad5f3864e407284e name: 'Temperature: Heatsink' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.35.0 @@ -842,6 +905,7 @@ zabbix_export: value: Temperature discovery_rules: - + uuid: 81b324d81e6549d59cbf14163181fb48 name: 'Battery voltage discovery' type: DEPENDENT key: battery.voltage.discovery @@ -849,6 +913,7 @@ zabbix_export: description: 'Discovery for battery voltage triggers' item_prototypes: - + uuid: 903b96b7eb37482da469fc802d3da1b0 name: 'Battery: Voltage{#SINGLETON}' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.33333.3.30.0 @@ -876,16 +941,19 @@ zabbix_export: value: Battery trigger_prototypes: - + uuid: 14106e96a9b741498b7e8f8a715f7769 expression: 'min(/Morningstar SunSaver MPPT SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}' name: 'Battery: Critically high battery voltage (over {#VOLTAGE.MAX.CRIT}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 3478c3e1c29543f59dcd24839d007b38 expression: 'max(/Morningstar SunSaver MPPT SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}' name: 'Battery: Critically low battery voltage (below {#VOLTAGE.MIN.CRIT}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH - + uuid: 436548c625184ecea07dca150e44844b expression: 'min(/Morningstar SunSaver MPPT SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.WARN}' name: 'Battery: High battery voltage (over {#VOLTAGE.MAX.WARN}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -895,6 +963,7 @@ zabbix_export: name: 'Battery: Critically high battery voltage (over {#VOLTAGE.MAX.CRIT}V for 5m)' expression: 'min(/Morningstar SunSaver MPPT SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}' - + uuid: 7eade0d03a904eef9747082c9b7bebb1 expression: 'max(/Morningstar SunSaver MPPT SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.WARN}' name: 'Battery: Low battery voltage (below {#VOLTAGE.MIN.WARN}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -905,6 +974,7 @@ zabbix_export: expression: 'max(/Morningstar SunSaver MPPT SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}' graph_prototypes: - + uuid: b3520796c85a45df954633bc5f87d80b name: 'Voltage: Battery/Load{#SINGLETON}' graph_items: - @@ -1003,6 +1073,7 @@ zabbix_export: macro: '{$VOLTAGE.MIN.WARN}' valuemaps: - + uuid: b51b9440e801481fbb76f28b4a5431d1 name: 'SunSaver MPPT charge state' mappings: - @@ -1033,6 +1104,7 @@ zabbix_export: value: '8' newvalue: Equalize - + uuid: f21076ed51104b84ba4d78dd74bd1a5b name: 'SunSaver MPPT load state' mappings: - @@ -1064,6 +1136,7 @@ zabbix_export: newvalue: NotUsed graphs: - + uuid: 6090c266226d431193b00fb3db49ae07 name: 'Array: Voltage' graph_items: - @@ -1087,6 +1160,7 @@ zabbix_export: host: 'Morningstar SunSaver MPPT SNMP' key: 'array.voltage[arrayVoltage.0]' - + uuid: ad5b73c7352747a6930c9d8647f70bf1 name: 'Current: Charge/Load' graph_items: - @@ -1103,6 +1177,7 @@ zabbix_export: host: 'Morningstar SunSaver MPPT SNMP' key: 'load.current[loadCurrent.0]' - + uuid: 7b96265600a748728d881f5dfee485d2 name: 'Temperature: Ambient/Battery/Heatsink' graph_items: - |