Diffstat (limited to 'templates/power/apc')
-rw-r--r--templates/power/apc/apc_ups_galaxy_3500_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_galaxy_3500_snmp/template_power_apc_ups_galaxy_3500_snmp.yaml178
-rw-r--r--templates/power/apc/apc_ups_smart_2200_rm_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_smart_2200_rm_snmp/template_power_apc_ups_smart_2200_rm_snmp.yaml178
-rw-r--r--templates/power/apc/apc_ups_smart_3000_xlm_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_smart_3000_xlm_snmp/template_power_apc_ups_smart_3000_xlm_snmp.yaml178
-rw-r--r--templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml178
-rw-r--r--templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/template_power_apc_ups_smart_rt_1000_xl_snmp.yaml178
-rw-r--r--templates/power/apc/apc_ups_smart_srt_5000_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_smart_srt_5000_snmp/template_power_apc_ups_smart_srt_5000_snmp.yaml178
-rw-r--r--templates/power/apc/apc_ups_smart_srt_8000_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_smart_srt_8000_snmp/template_power_apc_ups_smart_srt_8000_snmp.yaml178
-rw-r--r--templates/power/apc/apc_ups_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_snmp/template_power_apc_ups_snmp.yaml178
-rw-r--r--templates/power/apc/apc_ups_symmetra_lx_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml178
-rw-r--r--templates/power/apc/apc_ups_symmetra_rm_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_symmetra_rm_snmp/template_power_apc_ups_symmetra_rm_snmp.yaml178
-rw-r--r--templates/power/apc/apc_ups_symmetra_rx_snmp/README.md2
-rw-r--r--templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml178
22 files changed, 44 insertions, 1936 deletions
diff --git a/templates/power/apc/apc_ups_galaxy_3500_snmp/README.md b/templates/power/apc/apc_ups_galaxy_3500_snmp/README.md
index 4622dd428cf..cb2d9e4bc33 100644
--- a/templates/power/apc/apc_ups_galaxy_3500_snmp/README.md
+++ b/templates/power/apc/apc_ups_galaxy_3500_snmp/README.md
@@ -129,7 +129,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC UPS Galaxy 3500 SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC UPS Galaxy 3500 SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC UPS Galaxy 3500 SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC UPS Galaxy 3500 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC UPS Galaxy 3500 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC UPS Galaxy 3500 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC UPS Galaxy 3500 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Galaxy 3500 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC UPS Galaxy 3500 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Galaxy 3500 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_galaxy_3500_snmp/template_power_apc_ups_galaxy_3500_snmp.yaml b/templates/power/apc/apc_ups_galaxy_3500_snmp/template_power_apc_ups_galaxy_3500_snmp.yaml
index a7cacc15d08..185b9b9234f 100644
--- a/templates/power/apc/apc_ups_galaxy_3500_snmp/template_power_apc_ups_galaxy_3500_snmp.yaml
+++ b/templates/power/apc/apc_ups_galaxy_3500_snmp/template_power_apc_ups_galaxy_3500_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:24Z'
- groups:
+ date: '2022-06-07T19:37:45Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1624,178 +1624,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: 23bf458b1bbc4ae0b145597292d098cb
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC UPS Galaxy 3500 SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC UPS Galaxy 3500 SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC UPS Galaxy 3500 SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC UPS Galaxy 3500 SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC UPS Galaxy 3500 SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC UPS Galaxy 3500 SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC UPS Galaxy 3500 SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC UPS Galaxy 3500 SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC UPS Galaxy 3500 SNMP'
valuemaps:
-
uuid: 30a78904cbc94fc58609dc1a11aa48ef
diff --git a/templates/power/apc/apc_ups_smart_2200_rm_snmp/README.md b/templates/power/apc/apc_ups_smart_2200_rm_snmp/README.md
index f5b06206e5b..e22da4ce73b 100644
--- a/templates/power/apc/apc_ups_smart_2200_rm_snmp/README.md
+++ b/templates/power/apc/apc_ups_smart_2200_rm_snmp/README.md
@@ -129,7 +129,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC Smart-UPS 2200 RM SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS 2200 RM SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS 2200 RM SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS 2200 RM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS 2200 RM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS 2200 RM SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS 2200 RM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS 2200 RM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS 2200 RM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS 2200 RM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_smart_2200_rm_snmp/template_power_apc_ups_smart_2200_rm_snmp.yaml b/templates/power/apc/apc_ups_smart_2200_rm_snmp/template_power_apc_ups_smart_2200_rm_snmp.yaml
index 535bce834d0..341b803f16a 100644
--- a/templates/power/apc/apc_ups_smart_2200_rm_snmp/template_power_apc_ups_smart_2200_rm_snmp.yaml
+++ b/templates/power/apc/apc_ups_smart_2200_rm_snmp/template_power_apc_ups_smart_2200_rm_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:25Z'
- groups:
+ date: '2022-06-07T19:37:46Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1624,178 +1624,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: ac27c888a2c547b2b71fe6bf1aad69b1
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC Smart-UPS 2200 RM SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC Smart-UPS 2200 RM SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC Smart-UPS 2200 RM SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC Smart-UPS 2200 RM SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC Smart-UPS 2200 RM SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC Smart-UPS 2200 RM SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC Smart-UPS 2200 RM SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC Smart-UPS 2200 RM SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC Smart-UPS 2200 RM SNMP'
valuemaps:
-
uuid: 6940a4d08173433bb4bc8ff3b44e578c
diff --git a/templates/power/apc/apc_ups_smart_3000_xlm_snmp/README.md b/templates/power/apc/apc_ups_smart_3000_xlm_snmp/README.md
index e8c4a917bf8..a2b0044ddf3 100644
--- a/templates/power/apc/apc_ups_smart_3000_xlm_snmp/README.md
+++ b/templates/power/apc/apc_ups_smart_3000_xlm_snmp/README.md
@@ -129,7 +129,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC Smart-UPS 3000 XLM SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS 3000 XLM SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS 3000 XLM SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS 3000 XLM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS 3000 XLM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS 3000 XLM SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS 3000 XLM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS 3000 XLM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS 3000 XLM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS 3000 XLM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_smart_3000_xlm_snmp/template_power_apc_ups_smart_3000_xlm_snmp.yaml b/templates/power/apc/apc_ups_smart_3000_xlm_snmp/template_power_apc_ups_smart_3000_xlm_snmp.yaml
index 97845dade62..66010faee4d 100644
--- a/templates/power/apc/apc_ups_smart_3000_xlm_snmp/template_power_apc_ups_smart_3000_xlm_snmp.yaml
+++ b/templates/power/apc/apc_ups_smart_3000_xlm_snmp/template_power_apc_ups_smart_3000_xlm_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:26Z'
- groups:
+ date: '2022-06-07T19:37:47Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1624,178 +1624,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: 829373d305ce44cc9441714fc9d828a5
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC Smart-UPS 3000 XLM SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC Smart-UPS 3000 XLM SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC Smart-UPS 3000 XLM SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC Smart-UPS 3000 XLM SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC Smart-UPS 3000 XLM SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC Smart-UPS 3000 XLM SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC Smart-UPS 3000 XLM SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC Smart-UPS 3000 XLM SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC Smart-UPS 3000 XLM SNMP'
valuemaps:
-
uuid: 55fecbd639c44c328b4199569a7305ef
diff --git a/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/README.md b/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/README.md
index e7a0f8452cc..68d02024cbb 100644
--- a/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/README.md
+++ b/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/README.md
@@ -129,7 +129,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS RT 1000 RM XL SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS RT 1000 RM XL SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS RT 1000 RM XL SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS RT 1000 RM XL SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS RT 1000 RM XL SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml b/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml
index f0be9e4916e..1bb4c931fb8 100644
--- a/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml
+++ b/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:27Z'
- groups:
+ date: '2022-06-07T19:37:47Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1624,178 +1624,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: 2fba6e227f9b4d8fa584664bfd600cf4
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC Smart-UPS RT 1000 RM XL SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC Smart-UPS RT 1000 RM XL SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC Smart-UPS RT 1000 RM XL SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC Smart-UPS RT 1000 RM XL SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC Smart-UPS RT 1000 RM XL SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC Smart-UPS RT 1000 RM XL SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC Smart-UPS RT 1000 RM XL SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC Smart-UPS RT 1000 RM XL SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC Smart-UPS RT 1000 RM XL SNMP'
valuemaps:
-
uuid: 7cf932d3b9304f2cb151134e9ea3be82
diff --git a/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/README.md b/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/README.md
index b071a90ee4d..68ac1229fb8 100644
--- a/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/README.md
+++ b/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/README.md
@@ -129,7 +129,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC Smart-UPS RT 1000 XL SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS RT 1000 XL SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS RT 1000 XL SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS RT 1000 XL SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS RT 1000 XL SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS RT 1000 XL SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS RT 1000 XL SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 XL SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS RT 1000 XL SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 XL SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/template_power_apc_ups_smart_rt_1000_xl_snmp.yaml b/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/template_power_apc_ups_smart_rt_1000_xl_snmp.yaml
index 8ba73db1516..a5f15401780 100644
--- a/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/template_power_apc_ups_smart_rt_1000_xl_snmp.yaml
+++ b/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/template_power_apc_ups_smart_rt_1000_xl_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:28Z'
- groups:
+ date: '2022-06-07T19:37:48Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1624,178 +1624,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: 8e5f02a3eab44a5f85011b7331696284
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC Smart-UPS RT 1000 XL SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC Smart-UPS RT 1000 XL SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC Smart-UPS RT 1000 XL SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC Smart-UPS RT 1000 XL SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC Smart-UPS RT 1000 XL SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC Smart-UPS RT 1000 XL SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC Smart-UPS RT 1000 XL SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC Smart-UPS RT 1000 XL SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC Smart-UPS RT 1000 XL SNMP'
valuemaps:
-
uuid: b2af1e2dcb874d43949c383f9b347f36
diff --git a/templates/power/apc/apc_ups_smart_srt_5000_snmp/README.md b/templates/power/apc/apc_ups_smart_srt_5000_snmp/README.md
index a32160e41ed..ceb95869a1a 100644
--- a/templates/power/apc/apc_ups_smart_srt_5000_snmp/README.md
+++ b/templates/power/apc/apc_ups_smart_srt_5000_snmp/README.md
@@ -129,7 +129,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC Smart-UPS SRT 5000 SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS SRT 5000 SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS SRT 5000 SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS SRT 5000 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS SRT 5000 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS SRT 5000 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS SRT 5000 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 5000 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS SRT 5000 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 5000 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_smart_srt_5000_snmp/template_power_apc_ups_smart_srt_5000_snmp.yaml b/templates/power/apc/apc_ups_smart_srt_5000_snmp/template_power_apc_ups_smart_srt_5000_snmp.yaml
index 561eec8762d..f4e130a2384 100644
--- a/templates/power/apc/apc_ups_smart_srt_5000_snmp/template_power_apc_ups_smart_srt_5000_snmp.yaml
+++ b/templates/power/apc/apc_ups_smart_srt_5000_snmp/template_power_apc_ups_smart_srt_5000_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:30Z'
- groups:
+ date: '2022-06-07T19:37:49Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1624,178 +1624,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: ceb28c7c39e44859a4c1076978a40788
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC Smart-UPS SRT 5000 SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC Smart-UPS SRT 5000 SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC Smart-UPS SRT 5000 SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC Smart-UPS SRT 5000 SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC Smart-UPS SRT 5000 SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC Smart-UPS SRT 5000 SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC Smart-UPS SRT 5000 SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC Smart-UPS SRT 5000 SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC Smart-UPS SRT 5000 SNMP'
valuemaps:
-
uuid: 41e166e2a5f948488238198920ab4b17
diff --git a/templates/power/apc/apc_ups_smart_srt_8000_snmp/README.md b/templates/power/apc/apc_ups_smart_srt_8000_snmp/README.md
index 43a027be10a..18c2018f37d 100644
--- a/templates/power/apc/apc_ups_smart_srt_8000_snmp/README.md
+++ b/templates/power/apc/apc_ups_smart_srt_8000_snmp/README.md
@@ -129,7 +129,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC Smart-UPS SRT 8000 SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS SRT 8000 SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS SRT 8000 SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS SRT 8000 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS SRT 8000 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS SRT 8000 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS SRT 8000 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 8000 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS SRT 8000 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 8000 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_smart_srt_8000_snmp/template_power_apc_ups_smart_srt_8000_snmp.yaml b/templates/power/apc/apc_ups_smart_srt_8000_snmp/template_power_apc_ups_smart_srt_8000_snmp.yaml
index cda97e31af1..1013bccaf68 100644
--- a/templates/power/apc/apc_ups_smart_srt_8000_snmp/template_power_apc_ups_smart_srt_8000_snmp.yaml
+++ b/templates/power/apc/apc_ups_smart_srt_8000_snmp/template_power_apc_ups_smart_srt_8000_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:31Z'
- groups:
+ date: '2022-06-07T19:37:49Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1624,178 +1624,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: 268ead40a9dd40798df6d75f554ec1bb
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC Smart-UPS SRT 8000 SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC Smart-UPS SRT 8000 SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC Smart-UPS SRT 8000 SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC Smart-UPS SRT 8000 SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC Smart-UPS SRT 8000 SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC Smart-UPS SRT 8000 SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC Smart-UPS SRT 8000 SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC Smart-UPS SRT 8000 SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC Smart-UPS SRT 8000 SNMP'
valuemaps:
-
uuid: 864d59cbfcc8431cb334b812bf7ef3a3
diff --git a/templates/power/apc/apc_ups_snmp/README.md b/templates/power/apc/apc_ups_snmp/README.md
index 11211ad37cd..7ed47d22a19 100644
--- a/templates/power/apc/apc_ups_snmp/README.md
+++ b/templates/power/apc/apc_ups_snmp/README.md
@@ -125,7 +125,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC UPS SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC UPS SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC UPS SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC UPS SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC UPS SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC UPS SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC UPS SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC UPS SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_snmp/template_power_apc_ups_snmp.yaml b/templates/power/apc/apc_ups_snmp/template_power_apc_ups_snmp.yaml
index 47dd06c8be3..0fccd0349b7 100644
--- a/templates/power/apc/apc_ups_snmp/template_power_apc_ups_snmp.yaml
+++ b/templates/power/apc/apc_ups_snmp/template_power_apc_ups_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:23Z'
- groups:
+ date: '2022-06-07T19:37:45Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1621,178 +1621,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: e1b2126fa06d44e3b0984f5bb904cd9a
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC UPS SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC UPS SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC UPS SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC UPS SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC UPS SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC UPS SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC UPS SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC UPS SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC UPS SNMP'
valuemaps:
-
uuid: a808aadebf964e0cb6b8724bf1165013
diff --git a/templates/power/apc/apc_ups_symmetra_lx_snmp/README.md b/templates/power/apc/apc_ups_symmetra_lx_snmp/README.md
index 8e859cf8188..b7dfbed36b8 100644
--- a/templates/power/apc/apc_ups_symmetra_lx_snmp/README.md
+++ b/templates/power/apc/apc_ups_symmetra_lx_snmp/README.md
@@ -129,7 +129,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC UPS Symmetra LX SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC UPS Symmetra LX SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC UPS Symmetra LX SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC UPS Symmetra LX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC UPS Symmetra LX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml b/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml
index 10fd49d4923..44de072230e 100644
--- a/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml
+++ b/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:32Z'
- groups:
+ date: '2022-06-07T19:37:50Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1624,178 +1624,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: fbf5cb79251d48bdbe4bc7b81dbd2d65
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC UPS Symmetra LX SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC UPS Symmetra LX SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC UPS Symmetra LX SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC UPS Symmetra LX SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC UPS Symmetra LX SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC UPS Symmetra LX SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC UPS Symmetra LX SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC UPS Symmetra LX SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC UPS Symmetra LX SNMP'
valuemaps:
-
uuid: aec3362485c242ec928cb8ecfe5e61cf
diff --git a/templates/power/apc/apc_ups_symmetra_rm_snmp/README.md b/templates/power/apc/apc_ups_symmetra_rm_snmp/README.md
index 91450d8fe17..d5adb3840c7 100644
--- a/templates/power/apc/apc_ups_symmetra_rm_snmp/README.md
+++ b/templates/power/apc/apc_ups_symmetra_rm_snmp/README.md
@@ -129,7 +129,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC UPS Symmetra RM SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC UPS Symmetra RM SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC UPS Symmetra RM SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC UPS Symmetra RM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC UPS Symmetra RM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC UPS Symmetra RM SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC UPS Symmetra RM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC UPS Symmetra RM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_symmetra_rm_snmp/template_power_apc_ups_symmetra_rm_snmp.yaml b/templates/power/apc/apc_ups_symmetra_rm_snmp/template_power_apc_ups_symmetra_rm_snmp.yaml
index 923b18cd707..921c747de88 100644
--- a/templates/power/apc/apc_ups_symmetra_rm_snmp/template_power_apc_ups_symmetra_rm_snmp.yaml
+++ b/templates/power/apc/apc_ups_symmetra_rm_snmp/template_power_apc_ups_symmetra_rm_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:33Z'
- groups:
+ date: '2022-06-07T19:37:51Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1624,178 +1624,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: 3d8fa7f93f9f4a0bbc0b9f70282aa5cd
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC UPS Symmetra RM SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC UPS Symmetra RM SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC UPS Symmetra RM SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC UPS Symmetra RM SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC UPS Symmetra RM SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC UPS Symmetra RM SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC UPS Symmetra RM SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC UPS Symmetra RM SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC UPS Symmetra RM SNMP'
valuemaps:
-
uuid: 8516e97893ed4f2ebe70766d17eeacde
diff --git a/templates/power/apc/apc_ups_symmetra_rx_snmp/README.md b/templates/power/apc/apc_ups_symmetra_rx_snmp/README.md
index c14cb5c9e4a..d60f28a4b61 100644
--- a/templates/power/apc/apc_ups_symmetra_rx_snmp/README.md
+++ b/templates/power/apc/apc_ups_symmetra_rx_snmp/README.md
@@ -125,7 +125,7 @@ There are no template links in this template.
|UPS is Off |<p>-</p> |`last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | |
|UPS is Emergency Static Bypass |<p>-</p> |`last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | |
|UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | |
-|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC UPS Symmetra RX SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC UPS Symmetra RX SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC UPS Symmetra RX SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC UPS Symmetra RX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
|{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC UPS Symmetra RX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | |
diff --git a/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml b/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml
index d95833819fe..d6297fbdc67 100644
--- a/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml
+++ b/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml
@@ -1,7 +1,7 @@
zabbix_export:
version: '6.2'
- date: '2022-04-06T20:01:34Z'
- groups:
+ date: '2022-06-07T19:37:51Z'
+ template_groups:
-
uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
name: Templates/Power
@@ -851,7 +851,7 @@ zabbix_export:
name: 'has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
- description: 'Uptime is less than 10 minutes'
+ description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
-
@@ -1624,178 +1624,6 @@ zabbix_export:
macro: '{$UPS.OUTPUT.MAX.WARN}'
value: '80'
description: 'Maximum output load in % for trigger expression.'
- dashboards:
- -
- uuid: b070a774806547ffa7e688b2746c8d58
- name: 'UPS Summary'
- pages:
- -
- widgets:
- -
- type: PLAIN_TEXT
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'system.uptime[sysUpTime.0]'
- host: 'APC UPS Symmetra RX SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'input.fail[upsAdvInputLineFailCause]'
- host: 'APC UPS Symmetra RX SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'output.status[upsBasicOutputStatus]'
- host: 'APC UPS Symmetra RX SNMP'
- -
- type: PLAIN_TEXT
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.status[upsBasicBatteryStatus]'
- host: 'APC UPS Symmetra RX SNMP'
- -
- type: PLAIN_TEXT
- x: '8'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
- host: 'APC UPS Symmetra RX SNMP'
- -
- type: PLAIN_TEXT
- x: '16'
- 'y': '2'
- width: '8'
- fields:
- -
- type: INTEGER
- name: show_as_html
- value: '0'
- -
- type: INTEGER
- name: show_lines
- value: '1'
- -
- type: ITEM
- name: itemids
- value:
- key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
- host: 'APC UPS Symmetra RX SNMP'
- -
- type: GRAPH_CLASSIC
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: 'Capacity of the UPS batteries'
- host: 'APC UPS Symmetra RX SNMP'
- -
- type: GRAPH_CLASSIC
- x: '8'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Voltage
- host: 'APC UPS Symmetra RX SNMP'
- -
- type: GRAPH_CLASSIC
- x: '16'
- 'y': '4'
- width: '8'
- height: '7'
- fields:
- -
- type: INTEGER
- name: source_type
- value: '0'
- -
- type: GRAPH
- name: graphid
- value:
- name: Output
- host: 'APC UPS Symmetra RX SNMP'
valuemaps:
-
uuid: e2877a188bd24918992f8c7878550924