diff options
Diffstat (limited to 'templates/power/apc')
22 files changed, 44 insertions, 1936 deletions
diff --git a/templates/power/apc/apc_ups_galaxy_3500_snmp/README.md b/templates/power/apc/apc_ups_galaxy_3500_snmp/README.md index 4622dd428cf..cb2d9e4bc33 100644 --- a/templates/power/apc/apc_ups_galaxy_3500_snmp/README.md +++ b/templates/power/apc/apc_ups_galaxy_3500_snmp/README.md @@ -129,7 +129,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC UPS Galaxy 3500 SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC UPS Galaxy 3500 SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC UPS Galaxy 3500 SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC UPS Galaxy 3500 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC UPS Galaxy 3500 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC UPS Galaxy 3500 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC UPS Galaxy 3500 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Galaxy 3500 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC UPS Galaxy 3500 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Galaxy 3500 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_galaxy_3500_snmp/template_power_apc_ups_galaxy_3500_snmp.yaml b/templates/power/apc/apc_ups_galaxy_3500_snmp/template_power_apc_ups_galaxy_3500_snmp.yaml index a7cacc15d08..185b9b9234f 100644 --- a/templates/power/apc/apc_ups_galaxy_3500_snmp/template_power_apc_ups_galaxy_3500_snmp.yaml +++ b/templates/power/apc/apc_ups_galaxy_3500_snmp/template_power_apc_ups_galaxy_3500_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:24Z' - groups: + date: '2022-06-07T19:37:45Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: 23bf458b1bbc4ae0b145597292d098cb - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC UPS Galaxy 3500 SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC UPS Galaxy 3500 SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC UPS Galaxy 3500 SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC UPS Galaxy 3500 SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC UPS Galaxy 3500 SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC UPS Galaxy 3500 SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC UPS Galaxy 3500 SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC UPS Galaxy 3500 SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC UPS Galaxy 3500 SNMP' valuemaps: - uuid: 30a78904cbc94fc58609dc1a11aa48ef diff --git a/templates/power/apc/apc_ups_smart_2200_rm_snmp/README.md b/templates/power/apc/apc_ups_smart_2200_rm_snmp/README.md index f5b06206e5b..e22da4ce73b 100644 --- a/templates/power/apc/apc_ups_smart_2200_rm_snmp/README.md +++ b/templates/power/apc/apc_ups_smart_2200_rm_snmp/README.md @@ -129,7 +129,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC Smart-UPS 2200 RM SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS 2200 RM SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS 2200 RM SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS 2200 RM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS 2200 RM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS 2200 RM SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS 2200 RM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS 2200 RM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS 2200 RM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS 2200 RM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_smart_2200_rm_snmp/template_power_apc_ups_smart_2200_rm_snmp.yaml b/templates/power/apc/apc_ups_smart_2200_rm_snmp/template_power_apc_ups_smart_2200_rm_snmp.yaml index 535bce834d0..341b803f16a 100644 --- a/templates/power/apc/apc_ups_smart_2200_rm_snmp/template_power_apc_ups_smart_2200_rm_snmp.yaml +++ b/templates/power/apc/apc_ups_smart_2200_rm_snmp/template_power_apc_ups_smart_2200_rm_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:25Z' - groups: + date: '2022-06-07T19:37:46Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: ac27c888a2c547b2b71fe6bf1aad69b1 - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC Smart-UPS 2200 RM SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC Smart-UPS 2200 RM SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC Smart-UPS 2200 RM SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC Smart-UPS 2200 RM SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC Smart-UPS 2200 RM SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC Smart-UPS 2200 RM SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC Smart-UPS 2200 RM SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC Smart-UPS 2200 RM SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC Smart-UPS 2200 RM SNMP' valuemaps: - uuid: 6940a4d08173433bb4bc8ff3b44e578c diff --git a/templates/power/apc/apc_ups_smart_3000_xlm_snmp/README.md b/templates/power/apc/apc_ups_smart_3000_xlm_snmp/README.md index e8c4a917bf8..a2b0044ddf3 100644 --- a/templates/power/apc/apc_ups_smart_3000_xlm_snmp/README.md +++ b/templates/power/apc/apc_ups_smart_3000_xlm_snmp/README.md @@ -129,7 +129,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC Smart-UPS 3000 XLM SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS 3000 XLM SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS 3000 XLM SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS 3000 XLM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS 3000 XLM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS 3000 XLM SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS 3000 XLM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS 3000 XLM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS 3000 XLM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS 3000 XLM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_smart_3000_xlm_snmp/template_power_apc_ups_smart_3000_xlm_snmp.yaml b/templates/power/apc/apc_ups_smart_3000_xlm_snmp/template_power_apc_ups_smart_3000_xlm_snmp.yaml index 97845dade62..66010faee4d 100644 --- a/templates/power/apc/apc_ups_smart_3000_xlm_snmp/template_power_apc_ups_smart_3000_xlm_snmp.yaml +++ b/templates/power/apc/apc_ups_smart_3000_xlm_snmp/template_power_apc_ups_smart_3000_xlm_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:26Z' - groups: + date: '2022-06-07T19:37:47Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: 829373d305ce44cc9441714fc9d828a5 - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC Smart-UPS 3000 XLM SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC Smart-UPS 3000 XLM SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC Smart-UPS 3000 XLM SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC Smart-UPS 3000 XLM SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC Smart-UPS 3000 XLM SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC Smart-UPS 3000 XLM SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC Smart-UPS 3000 XLM SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC Smart-UPS 3000 XLM SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC Smart-UPS 3000 XLM SNMP' valuemaps: - uuid: 55fecbd639c44c328b4199569a7305ef diff --git a/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/README.md b/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/README.md index e7a0f8452cc..68d02024cbb 100644 --- a/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/README.md +++ b/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/README.md @@ -129,7 +129,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS RT 1000 RM XL SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS RT 1000 RM XL SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS RT 1000 RM XL SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS RT 1000 RM XL SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS RT 1000 RM XL SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml b/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml index f0be9e4916e..1bb4c931fb8 100644 --- a/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml +++ b/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:27Z' - groups: + date: '2022-06-07T19:37:47Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: 2fba6e227f9b4d8fa584664bfd600cf4 - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC Smart-UPS RT 1000 RM XL SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC Smart-UPS RT 1000 RM XL SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC Smart-UPS RT 1000 RM XL SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC Smart-UPS RT 1000 RM XL SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC Smart-UPS RT 1000 RM XL SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC Smart-UPS RT 1000 RM XL SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC Smart-UPS RT 1000 RM XL SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC Smart-UPS RT 1000 RM XL SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC Smart-UPS RT 1000 RM XL SNMP' valuemaps: - uuid: 7cf932d3b9304f2cb151134e9ea3be82 diff --git a/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/README.md b/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/README.md index b071a90ee4d..68ac1229fb8 100644 --- a/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/README.md +++ b/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/README.md @@ -129,7 +129,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC Smart-UPS RT 1000 XL SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS RT 1000 XL SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS RT 1000 XL SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS RT 1000 XL SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS RT 1000 XL SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS RT 1000 XL SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS RT 1000 XL SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 XL SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS RT 1000 XL SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 XL SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/template_power_apc_ups_smart_rt_1000_xl_snmp.yaml b/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/template_power_apc_ups_smart_rt_1000_xl_snmp.yaml index 8ba73db1516..a5f15401780 100644 --- a/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/template_power_apc_ups_smart_rt_1000_xl_snmp.yaml +++ b/templates/power/apc/apc_ups_smart_rt_1000_xl_snmp/template_power_apc_ups_smart_rt_1000_xl_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:28Z' - groups: + date: '2022-06-07T19:37:48Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: 8e5f02a3eab44a5f85011b7331696284 - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC Smart-UPS RT 1000 XL SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC Smart-UPS RT 1000 XL SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC Smart-UPS RT 1000 XL SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC Smart-UPS RT 1000 XL SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC Smart-UPS RT 1000 XL SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC Smart-UPS RT 1000 XL SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC Smart-UPS RT 1000 XL SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC Smart-UPS RT 1000 XL SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC Smart-UPS RT 1000 XL SNMP' valuemaps: - uuid: b2af1e2dcb874d43949c383f9b347f36 diff --git a/templates/power/apc/apc_ups_smart_srt_5000_snmp/README.md b/templates/power/apc/apc_ups_smart_srt_5000_snmp/README.md index a32160e41ed..ceb95869a1a 100644 --- a/templates/power/apc/apc_ups_smart_srt_5000_snmp/README.md +++ b/templates/power/apc/apc_ups_smart_srt_5000_snmp/README.md @@ -129,7 +129,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC Smart-UPS SRT 5000 SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS SRT 5000 SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS SRT 5000 SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS SRT 5000 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS SRT 5000 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS SRT 5000 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS SRT 5000 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 5000 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS SRT 5000 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 5000 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_smart_srt_5000_snmp/template_power_apc_ups_smart_srt_5000_snmp.yaml b/templates/power/apc/apc_ups_smart_srt_5000_snmp/template_power_apc_ups_smart_srt_5000_snmp.yaml index 561eec8762d..f4e130a2384 100644 --- a/templates/power/apc/apc_ups_smart_srt_5000_snmp/template_power_apc_ups_smart_srt_5000_snmp.yaml +++ b/templates/power/apc/apc_ups_smart_srt_5000_snmp/template_power_apc_ups_smart_srt_5000_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:30Z' - groups: + date: '2022-06-07T19:37:49Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: ceb28c7c39e44859a4c1076978a40788 - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_lines - value: '1' - - - type: INTEGER - name: show_as_html - value: '0' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC Smart-UPS SRT 5000 SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_lines - value: '1' - - - type: INTEGER - name: show_as_html - value: '0' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC Smart-UPS SRT 5000 SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_lines - value: '1' - - - type: INTEGER - name: show_as_html - value: '0' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC Smart-UPS SRT 5000 SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_lines - value: '1' - - - type: INTEGER - name: show_as_html - value: '0' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC Smart-UPS SRT 5000 SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_lines - value: '1' - - - type: INTEGER - name: show_as_html - value: '0' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC Smart-UPS SRT 5000 SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_lines - value: '1' - - - type: INTEGER - name: show_as_html - value: '0' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC Smart-UPS SRT 5000 SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC Smart-UPS SRT 5000 SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC Smart-UPS SRT 5000 SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC Smart-UPS SRT 5000 SNMP' valuemaps: - uuid: 41e166e2a5f948488238198920ab4b17 diff --git a/templates/power/apc/apc_ups_smart_srt_8000_snmp/README.md b/templates/power/apc/apc_ups_smart_srt_8000_snmp/README.md index 43a027be10a..18c2018f37d 100644 --- a/templates/power/apc/apc_ups_smart_srt_8000_snmp/README.md +++ b/templates/power/apc/apc_ups_smart_srt_8000_snmp/README.md @@ -129,7 +129,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC Smart-UPS SRT 8000 SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC Smart-UPS SRT 8000 SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC Smart-UPS SRT 8000 SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC Smart-UPS SRT 8000 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC Smart-UPS SRT 8000 SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC Smart-UPS SRT 8000 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC Smart-UPS SRT 8000 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 8000 SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC Smart-UPS SRT 8000 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 8000 SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_smart_srt_8000_snmp/template_power_apc_ups_smart_srt_8000_snmp.yaml b/templates/power/apc/apc_ups_smart_srt_8000_snmp/template_power_apc_ups_smart_srt_8000_snmp.yaml index cda97e31af1..1013bccaf68 100644 --- a/templates/power/apc/apc_ups_smart_srt_8000_snmp/template_power_apc_ups_smart_srt_8000_snmp.yaml +++ b/templates/power/apc/apc_ups_smart_srt_8000_snmp/template_power_apc_ups_smart_srt_8000_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:31Z' - groups: + date: '2022-06-07T19:37:49Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: 268ead40a9dd40798df6d75f554ec1bb - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC Smart-UPS SRT 8000 SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC Smart-UPS SRT 8000 SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC Smart-UPS SRT 8000 SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC Smart-UPS SRT 8000 SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC Smart-UPS SRT 8000 SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC Smart-UPS SRT 8000 SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC Smart-UPS SRT 8000 SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC Smart-UPS SRT 8000 SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC Smart-UPS SRT 8000 SNMP' valuemaps: - uuid: 864d59cbfcc8431cb334b812bf7ef3a3 diff --git a/templates/power/apc/apc_ups_snmp/README.md b/templates/power/apc/apc_ups_snmp/README.md index 11211ad37cd..7ed47d22a19 100644 --- a/templates/power/apc/apc_ups_snmp/README.md +++ b/templates/power/apc/apc_ups_snmp/README.md @@ -125,7 +125,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC UPS SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC UPS SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC UPS SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC UPS SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC UPS SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC UPS SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC UPS SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC UPS SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_snmp/template_power_apc_ups_snmp.yaml b/templates/power/apc/apc_ups_snmp/template_power_apc_ups_snmp.yaml index 47dd06c8be3..0fccd0349b7 100644 --- a/templates/power/apc/apc_ups_snmp/template_power_apc_ups_snmp.yaml +++ b/templates/power/apc/apc_ups_snmp/template_power_apc_ups_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:23Z' - groups: + date: '2022-06-07T19:37:45Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1621,178 +1621,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: e1b2126fa06d44e3b0984f5bb904cd9a - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC UPS SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC UPS SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC UPS SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC UPS SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC UPS SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC UPS SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC UPS SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC UPS SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC UPS SNMP' valuemaps: - uuid: a808aadebf964e0cb6b8724bf1165013 diff --git a/templates/power/apc/apc_ups_symmetra_lx_snmp/README.md b/templates/power/apc/apc_ups_symmetra_lx_snmp/README.md index 8e859cf8188..b7dfbed36b8 100644 --- a/templates/power/apc/apc_ups_symmetra_lx_snmp/README.md +++ b/templates/power/apc/apc_ups_symmetra_lx_snmp/README.md @@ -129,7 +129,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC UPS Symmetra LX SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC UPS Symmetra LX SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC UPS Symmetra LX SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC UPS Symmetra LX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC UPS Symmetra LX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml b/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml index 10fd49d4923..44de072230e 100644 --- a/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml +++ b/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:32Z' - groups: + date: '2022-06-07T19:37:50Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: fbf5cb79251d48bdbe4bc7b81dbd2d65 - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC UPS Symmetra LX SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC UPS Symmetra LX SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC UPS Symmetra LX SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC UPS Symmetra LX SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC UPS Symmetra LX SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC UPS Symmetra LX SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC UPS Symmetra LX SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC UPS Symmetra LX SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC UPS Symmetra LX SNMP' valuemaps: - uuid: aec3362485c242ec928cb8ecfe5e61cf diff --git a/templates/power/apc/apc_ups_symmetra_rm_snmp/README.md b/templates/power/apc/apc_ups_symmetra_rm_snmp/README.md index 91450d8fe17..d5adb3840c7 100644 --- a/templates/power/apc/apc_ups_symmetra_rm_snmp/README.md +++ b/templates/power/apc/apc_ups_symmetra_rm_snmp/README.md @@ -129,7 +129,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC UPS Symmetra RM SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC UPS Symmetra RM SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC UPS Symmetra RM SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC UPS Symmetra RM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC UPS Symmetra RM SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC UPS Symmetra RM SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC UPS Symmetra RM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RM SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC UPS Symmetra RM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RM SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_symmetra_rm_snmp/template_power_apc_ups_symmetra_rm_snmp.yaml b/templates/power/apc/apc_ups_symmetra_rm_snmp/template_power_apc_ups_symmetra_rm_snmp.yaml index 923b18cd707..921c747de88 100644 --- a/templates/power/apc/apc_ups_symmetra_rm_snmp/template_power_apc_ups_symmetra_rm_snmp.yaml +++ b/templates/power/apc/apc_ups_symmetra_rm_snmp/template_power_apc_ups_symmetra_rm_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:33Z' - groups: + date: '2022-06-07T19:37:51Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: 3d8fa7f93f9f4a0bbc0b9f70282aa5cd - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC UPS Symmetra RM SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC UPS Symmetra RM SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC UPS Symmetra RM SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC UPS Symmetra RM SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC UPS Symmetra RM SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC UPS Symmetra RM SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC UPS Symmetra RM SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC UPS Symmetra RM SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC UPS Symmetra RM SNMP' valuemaps: - uuid: 8516e97893ed4f2ebe70766d17eeacde diff --git a/templates/power/apc/apc_ups_symmetra_rx_snmp/README.md b/templates/power/apc/apc_ups_symmetra_rx_snmp/README.md index c14cb5c9e4a..d60f28a4b61 100644 --- a/templates/power/apc/apc_ups_symmetra_rx_snmp/README.md +++ b/templates/power/apc/apc_ups_symmetra_rx_snmp/README.md @@ -125,7 +125,7 @@ There are no template links in this template. |UPS is Off |<p>-</p> |`last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=7` |AVERAGE | | |UPS is Emergency Static Bypass |<p>-</p> |`last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=16` |AVERAGE | | |UPS is Hardware Failure Bypass |<p>-</p> |`last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=10` |AVERAGE | | -|has been restarted |<p>Uptime is less than 10 minutes</p> |`last(/APC UPS Symmetra RX SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|has been restarted |<p>Uptime is less than 10 minutes.</p> |`last(/APC UPS Symmetra RX SNMP/system.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | |No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/APC UPS Symmetra RX SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage |<p>-</p> |`min(/APC UPS Symmetra RX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | |{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage |<p>-</p> |`min(/APC UPS Symmetra RX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}` |HIGH | | diff --git a/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml b/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml index d95833819fe..d6297fbdc67 100644 --- a/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml +++ b/templates/power/apc/apc_ups_symmetra_rx_snmp/template_power_apc_ups_symmetra_rx_snmp.yaml @@ -1,7 +1,7 @@ zabbix_export: version: '6.2' - date: '2022-04-06T20:01:34Z' - groups: + date: '2022-06-07T19:37:51Z' + template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 name: Templates/Power @@ -851,7 +851,7 @@ zabbix_export: name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING - description: 'Uptime is less than 10 minutes' + description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - @@ -1624,178 +1624,6 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' - dashboards: - - - uuid: b070a774806547ffa7e688b2746c8d58 - name: 'UPS Summary' - pages: - - - widgets: - - - type: PLAIN_TEXT - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'system.uptime[sysUpTime.0]' - host: 'APC UPS Symmetra RX SNMP' - - - type: PLAIN_TEXT - x: '8' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'input.fail[upsAdvInputLineFailCause]' - host: 'APC UPS Symmetra RX SNMP' - - - type: PLAIN_TEXT - x: '16' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'output.status[upsBasicOutputStatus]' - host: 'APC UPS Symmetra RX SNMP' - - - type: PLAIN_TEXT - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.status[upsBasicBatteryStatus]' - host: 'APC UPS Symmetra RX SNMP' - - - type: PLAIN_TEXT - x: '8' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' - host: 'APC UPS Symmetra RX SNMP' - - - type: PLAIN_TEXT - x: '16' - 'y': '2' - width: '8' - fields: - - - type: INTEGER - name: show_as_html - value: '0' - - - type: INTEGER - name: show_lines - value: '1' - - - type: ITEM - name: itemids - value: - key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' - host: 'APC UPS Symmetra RX SNMP' - - - type: GRAPH_CLASSIC - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: 'Capacity of the UPS batteries' - host: 'APC UPS Symmetra RX SNMP' - - - type: GRAPH_CLASSIC - x: '8' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Voltage - host: 'APC UPS Symmetra RX SNMP' - - - type: GRAPH_CLASSIC - x: '16' - 'y': '4' - width: '8' - height: '7' - fields: - - - type: INTEGER - name: source_type - value: '0' - - - type: GRAPH - name: graphid - value: - name: Output - host: 'APC UPS Symmetra RX SNMP' valuemaps: - uuid: e2877a188bd24918992f8c7878550924 |