Welcome to mirror list, hosted at ThFree Co, Russian Federation.

github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
Diffstat (limited to 'templates/server/cisco_ucs_manager_snmp/README.md')
-rw-r--r--templates/server/cisco_ucs_manager_snmp/README.md76
1 files changed, 38 insertions, 38 deletions
diff --git a/templates/server/cisco_ucs_manager_snmp/README.md b/templates/server/cisco_ucs_manager_snmp/README.md
index dafcb078f90..d384c2349a7 100644
--- a/templates/server/cisco_ucs_manager_snmp/README.md
+++ b/templates/server/cisco_ucs_manager_snmp/README.md
@@ -3,7 +3,7 @@
## Overview
-For Zabbix version: 5.4 and higher
+For Zabbix version: 6.0 and higher
Cisco UCS® Manager provides unified, embedded management of all software and hardware
components of the Cisco Unified Computing System™ (Cisco UCS) across multiple chassis
and rack servers. It enables server, fabric, and storage provisioning as well as,
@@ -100,12 +100,12 @@ There are no template links in this template.
|Disk_arrays |{#DISKARRAY_LOCATION}: Disk array controller model |<p>MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB</p> |SNMP |cisco.ucs.hw.diskarray.model[cucsStorageControllerModel.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> |
|Disk_arrays |{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery status |<p>MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB</p> |SNMP |cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `6h`</p> |
|Fans |{#FAN_LOCATION}: Fan status |<p>MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB</p><p>Cisco UCS equipment:Fan:operState managed object property</p> |SNMP |cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `6h`</p> |
-|General |SNMP traps (fallback) |<p>Item is used to collect all SNMP traps unmatched by other snmptrap items</p> |SNMP_TRAP |snmptrap.fallback |
-|General |System location |<p>MIB: SNMPv2-MIB</p><p>The physical location of this node (e.g., `telephone closet,</p><p>3rd floor'). If the location is unknown, the value is the zero-length string.</p> |SNMP |cisco.ucs.location[sysLocation.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1h`</p> |
-|General |System contact details |<p>MIB: SNMPv2-MIB</p><p>The textual identification of the contact person for this managed</p><p>node, together with information on how to contact this person. If no contact</p><p>information is known, the value is the zero-length string.</p> |SNMP |cisco.ucs.contact[sysContact.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> |
-|General |System object ID |<p>MIB: SNMPv2-MIB</p><p>The vendor's authoritative identification of the network management</p><p>subsystem contained in the entity. This value is allocated within the SMI enterprises</p><p>subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining 'what</p><p>kind of box' is being managed. For example, if vendor 'Flintstones, Inc.' was</p><p>assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1</p><p>to its 'Fred Router'.</p> |SNMP |cisco.ucs.objectid[sysObjectID.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1h`</p> |
-|General |System name |<p>MIB: SNMPv2-MIB</p><p>An administratively-assigned name for this managed node.By</p><p>convention, this is the node's fully-qualified domain name. If the name is unknown,</p><p>the value is the zero-length string.</p> |SNMP |cisco.ucs.name[sysName.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1h`</p> |
-|General |System description |<p>MIB: SNMPv2-MIB</p><p>A textual description of the entity. This value should</p><p>include the full name and version identification of the system's hardware type, software operating-system, and</p><p>networking software.</p> |SNMP |cisco.ucs.descr[sysDescr.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> |
+|General |SNMP traps (fallback) |<p>The item is used to collect all SNMP traps unmatched by other snmptrap items</p> |SNMP_TRAP |snmptrap.fallback |
+|General |System location |<p>MIB: SNMPv2-MIB</p><p>The physical location of this node (e.g., `telephone closet,</p><p>3rd floor'). If the location is unknown, the value is the zero-length string.</p> |SNMP |cisco.ucs.location[sysLocation.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
+|General |System contact details |<p>MIB: SNMPv2-MIB</p><p>The textual identification of the contact person for this managed</p><p>node, together with information on how to contact this person. If no contact</p><p>information is known, the value is the zero-length string.</p> |SNMP |cisco.ucs.contact[sysContact.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
+|General |System object ID |<p>MIB: SNMPv2-MIB</p><p>The vendor's authoritative identification of the network management</p><p>subsystem contained in the entity. This value is allocated within the SMI enterprises</p><p>subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining 'what</p><p>kind of box' is being managed. For example, if vendor 'Flintstones, Inc.' was</p><p>assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1</p><p>to its 'Fred Router'.</p> |SNMP |cisco.ucs.objectid[sysObjectID.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
+|General |System name |<p>MIB: SNMPv2-MIB</p><p>An administratively-assigned name for this managed node.By</p><p>convention, this is the node's fully-qualified domain name. If the name is unknown,</p><p>the value is the zero-length string.</p> |SNMP |cisco.ucs.name[sysName.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
+|General |System description |<p>MIB: SNMPv2-MIB</p><p>A textual description of the entity. This value should</p><p>include the full name and version identification of the system's hardware type, software operating-system, and</p><p>networking software.</p> |SNMP |cisco.ucs.descr[sysDescr.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
|Inventory |{#UNIT_LOCATION}: Hardware model name |<p>MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB</p><p>Cisco UCS compute:RackUnit:model managed object property</p> |SNMP |cisco.ucs.hw.model[cucsComputeRackUnitModel.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> |
|Inventory |{#UNIT_LOCATION}: Hardware serial number |<p>MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB</p><p>Cisco UCS compute:RackUnit:serial managed object property</p> |SNMP |cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> |
|Network_interfaces |Interface {#IFNAME}({#IFALIAS}): Operational status |<p>MIB: IF-MIB</p><p>The current operational state of the interface.</p><p>- The testing(3) state indicates that no operational packet scan be passed</p><p>- If ifAdminStatus is down(2) then ifOperStatus should be down(2)</p><p>- If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic</p><p>- It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection)</p><p>- It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state</p><p>- It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.</p> |SNMP |cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `6h`</p> |
@@ -144,37 +144,37 @@ There are no template links in this template.
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----|----|----|
-|{#DISKARRAY_LOCATION}: Disk array controller is in critical state |<p>Please check the device for faults</p> |`{TEMPLATE_NAME:cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}].last()}={$DISK.ARRAY.STATUS.CRIT:"inoperable"}` |HIGH | |
-|{#DISKARRAY_LOCATION}: Disk array controller is in warning state |<p>Please check the device for faults</p> |`{TEMPLATE_NAME:cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}].last()}={$DISK.ARRAY.STATUS.WARN:"degraded"}` |AVERAGE |<p>**Depends on**:</p><p>- {#DISKARRAY_LOCATION}: Disk array controller is in critical state</p> |
-|{#DISKARRAY_LOCATION}: Disk array controller is not in optimal state |<p>Please check the device for faults</p> |`{TEMPLATE_NAME:cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}].last()}>{$DISK.ARRAY.STATUS.OK:"operable"}` |WARNING |<p>**Depends on**:</p><p>- {#DISKARRAY_LOCATION}: Disk array controller is in critical state</p><p>- {#DISKARRAY_LOCATION}: Disk array controller is in warning state</p> |
-|{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state! |<p>Please check the device for faults</p> |`{TEMPLATE_NAME:cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}].last()}={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}` |AVERAGE | |
-|{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is not in optimal state |<p>Please check the device for faults</p> |`{TEMPLATE_NAME:cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}].last()}<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}` |WARNING |<p>**Depends on**:</p><p>- {#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!</p> |
-|{#FAN_LOCATION}: Fan is in critical state |<p>Please check the fan unit</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}].last()}={$FAN.STATUS.CRIT:"inoperable"}` |AVERAGE | |
-|{#FAN_LOCATION}: Fan is in warning state |<p>Please check the fan unit</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}].last()}={$FAN.STATUS.WARN:"degraded"}` |WARNING |<p>**Depends on**:</p><p>- {#FAN_LOCATION}: Fan is in critical state</p> |
-|System name has changed (new name: {ITEM.VALUE}) |<p>System name has changed. Ack to close.</p> |`{TEMPLATE_NAME:cisco.ucs.name[sysName.0].diff()}=1 and {TEMPLATE_NAME:cisco.ucs.name[sysName.0].strlen()}>0` |INFO |<p>Manual close: YES</p> |
-|{#UNIT_LOCATION}: Device has been replaced (new serial number received) |<p>Device serial number has changed. Ack to close</p> |`{TEMPLATE_NAME:cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}].diff()}=1 and {TEMPLATE_NAME:cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}].strlen()}>0` |INFO |<p>Manual close: YES</p> |
-|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p><p>3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and ({TEMPLATE_NAME:cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}].last()}=2 and {TEMPLATE_NAME:cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}].diff()}=1)`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}].last()}<>2 or {$IFCONTROL:"{#IFNAME}"}=0` |AVERAGE |<p>Manual close: YES</p> |
-|Interface {#IFNAME}({#IFALIAS}): High error rate on {#IFNAME} ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m) |<p>Recovers when value below {$IF.ERRORS.WARN:"{#IFNAME}"} threshold.</p> |`{TEMPLATE_NAME:cisco.ucs.if.in.errors[ifInErrors.{#SNMPINDEX}].min(5m)}>{$IF.ERRORS.WARN:"{#IFNAME}"} or {Cisco UCS Manager SNMP:cisco.ucs.if.out.errors[ifOutErrors.{#SNMPINDEX}].min(5m)}>{$IF.ERRORS.WARN:"{#IFNAME}"}` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|{#DISK_LOCATION}: Physical disk failed |<p>Please check physical disk for warnings or errors</p> |`{TEMPLATE_NAME:cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}].last()}={$DISK.STATUS.FAIL:"failed"}` |HIGH | |
-|{#DISK_LOCATION}: Physical disk error |<p>Please check physical disk for warnings or errors</p> |`{TEMPLATE_NAME:cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}].last()}={$DISK.STATUS.CRIT:"bad"} or {TEMPLATE_NAME:cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}].last()}={$DISK.STATUS.CRIT:"predictiveFailure"}` |AVERAGE |<p>**Depends on**:</p><p>- {#DISK_LOCATION}: Physical disk failed</p> |
-|{#DISK_LOCATION}: Disk has been replaced (new serial number received) |<p>Disk serial number has changed. Ack to close</p> |`{TEMPLATE_NAME:cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}].diff()}=1 and {TEMPLATE_NAME:cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}].strlen()}>0` |INFO |<p>Manual close: YES</p> |
-|{#PSU_LOCATION}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}].last()}={$PSU.STATUS.CRIT:"inoperable"}` |AVERAGE | |
-|{#PSU_LOCATION}: Power supply is in warning state |<p>Please check the power supply unit for errors</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}].last()}={$PSU.STATUS.WARN:"degraded"}` |WARNING |<p>**Depends on**:</p><p>- {#PSU_LOCATION}: Power supply is in critical state</p> |
-|{HOST.NAME} has been restarted (uptime < 10m) |<p>Uptime is less than 10 minutes</p> |`{TEMPLATE_NAME:cisco.ucs.uptime[sysUpTime.0].last()}<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
-|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`{TEMPLATE_NAME:zabbix[host,snmp,available].max({$SNMP.TIMEOUT})}=0` |WARNING | |
-|{#UNIT_LOCATION}: System status is in critical state |<p>Please check the device for errors</p> |`{TEMPLATE_NAME:cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].last()}={$HEALTH.STATUS.CRIT:"computeFailed"} or {TEMPLATE_NAME:cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].last()}={$HEALTH.STATUS.CRIT:"configFailure"} or {TEMPLATE_NAME:cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].last()}={$HEALTH.STATUS.CRIT:"unconfigFailure"} or {TEMPLATE_NAME:cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].last()}={$HEALTH.STATUS.CRIT:"inoperable"}` |HIGH | |
-|{#UNIT_LOCATION}: System status is in warning state |<p>Please check the device for warnings</p> |`{TEMPLATE_NAME:cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].last()}={$HEALTH.STATUS.WARN:"testFailed"} or {TEMPLATE_NAME:cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].last()}={$HEALTH.STATUS.WARN:"thermalProblem"} or {TEMPLATE_NAME:cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].last()}={$HEALTH.STATUS.WARN:"powerProblem"} or {TEMPLATE_NAME:cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].last()}={$HEALTH.STATUS.WARN:"voltageProblem"} or {TEMPLATE_NAME:cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}].last()}={$HEALTH.STATUS.WARN:"diagnosticsFailed"}` |WARNING |<p>**Depends on**:</p><p>- {#UNIT_LOCATION}: System status is in critical state</p> |
-|{#SENSOR_LOCATION}.Ambient: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP.MAX.WARN:"Ambient"}`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].max(5m)}<{$TEMP.MAX.WARN:"Ambient"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p> |
-|{#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP.MAX.CRIT:"Ambient"}`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}].max(5m)}<{$TEMP.MAX.CRIT:"Ambient"}-3` |HIGH | |
-|{#SENSOR_LOCATION}.Front: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP.MAX.WARN:"Ambient"}`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].max(5m)}<{$TEMP.MAX.WARN:"Ambient"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p> |
-|{#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP.MAX.CRIT:"Ambient"}`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}].max(5m)}<{$TEMP.MAX.CRIT:"Ambient"}-3` |HIGH | |
-|{#SENSOR_LOCATION}.Rear: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP.MAX.WARN:"Ambient"}`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].max(5m)}<{$TEMP.MAX.WARN:"Ambient"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p> |
-|{#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].avg(5m)}>{$TEMP.MAX.CRIT:"Ambient"}`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}].max(5m)}<{$TEMP.MAX.CRIT:"Ambient"}-3` |HIGH | |
-|{#SENSOR_LOCATION}.IOH: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].avg(5m)}>{$TEMP.MAX.WARN:"Ambient"}`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].max(5m)}<{$TEMP.MAX.WARN:"Ambient"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p> |
-|{#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].avg(5m)}>{$TEMP.MAX.CRIT:"Ambient"}`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}].max(5m)}<{$TEMP.MAX.CRIT:"Ambient"}-3` |HIGH | |
-|{#SENSOR_LOCATION}: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"CPU"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].avg(5m)}>{$TEMP.MAX.WARN:"CPU"}`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].max(5m)}<{$TEMP.MAX.WARN:"CPU"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_LOCATION}: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"CPU"}</p> |
-|{#SENSOR_LOCATION}: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"CPU"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].avg(5m)}>{$TEMP.MAX.CRIT:"CPU"}`<p>Recovery expression:</p>`{TEMPLATE_NAME:cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}].max(5m)}<{$TEMP.MAX.CRIT:"CPU"}-3` |HIGH | |
-|{#VDISK_LOCATION}: Virtual disk is not in OK state |<p>Please check virtual disk for warnings or errors</p> |`{TEMPLATE_NAME:cisco.ucs.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}].last()}<>{$VDISK.STATUS.OK:"equipped"}` |WARNING | |
+|{#DISKARRAY_LOCATION}: Disk array controller is in critical state |<p>Please check the device for faults</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT:"inoperable"}` |HIGH | |
+|{#DISKARRAY_LOCATION}: Disk array controller is in warning state |<p>Please check the device for faults</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN:"degraded"}` |AVERAGE |<p>**Depends on**:</p><p>- {#DISKARRAY_LOCATION}: Disk array controller is in critical state</p> |
+|{#DISKARRAY_LOCATION}: Disk array controller is not in optimal state |<p>Please check the device for faults</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])>{$DISK.ARRAY.STATUS.OK:"operable"}` |WARNING |<p>**Depends on**:</p><p>- {#DISKARRAY_LOCATION}: Disk array controller is in critical state</p><p>- {#DISKARRAY_LOCATION}: Disk array controller is in warning state</p> |
+|{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state! |<p>Please check the device for faults</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}` |AVERAGE | |
+|{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is not in optimal state |<p>Please check the device for faults</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}` |WARNING |<p>**Depends on**:</p><p>- {#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!</p> |
+|{#FAN_LOCATION}: Fan is in critical state |<p>Please check the fan unit</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"inoperable"}` |AVERAGE | |
+|{#FAN_LOCATION}: Fan is in warning state |<p>Please check the fan unit</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}])={$FAN.STATUS.WARN:"degraded"}` |WARNING |<p>**Depends on**:</p><p>- {#FAN_LOCATION}: Fan is in critical state</p> |
+|System name has changed (new name: {ITEM.VALUE}) |<p>System name has changed. Ack to close.</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.name[sysName.0],#1)<>last(/Cisco UCS Manager SNMP/cisco.ucs.name[sysName.0],#2) and length(last(/Cisco UCS Manager SNMP/cisco.ucs.name[sysName.0]))>0` |INFO |<p>Manual close: YES</p> |
+|{#UNIT_LOCATION}: Device has been replaced (new serial number received) |<p>Device serial number has changed. Ack to close</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager SNMP/cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}],#2) and length(last(/Cisco UCS Manager SNMP/cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> |
+|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p><p>3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}],#2))`<p>Recovery expression:</p>`last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0` |AVERAGE |<p>Manual close: YES</p> |
+|Interface {#IFNAME}({#IFALIAS}): High error rate on {#IFNAME} ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m) |<p>Recovers when value below {$IF.ERRORS.WARN:"{#IFNAME}"} threshold.</p> |`min(/Cisco UCS Manager SNMP/cisco.ucs.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Cisco UCS Manager SNMP/cisco.ucs.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} ` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|{#DISK_LOCATION}: Physical disk failed |<p>Please check physical disk for warnings or errors</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"failed"}` |HIGH | |
+|{#DISK_LOCATION}: Physical disk error |<p>Please check physical disk for warnings or errors</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.CRIT:"bad"} or last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.CRIT:"predictiveFailure"}` |AVERAGE |<p>**Depends on**:</p><p>- {#DISK_LOCATION}: Physical disk failed</p> |
+|{#DISK_LOCATION}: Disk has been replaced (new serial number received) |<p>Disk serial number has changed. Ack to close</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}],#2) and length(last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> |
+|{#PSU_LOCATION}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"inoperable"}` |AVERAGE | |
+|{#PSU_LOCATION}: Power supply is in warning state |<p>Please check the power supply unit for errors</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}])={$PSU.STATUS.WARN:"degraded"}` |WARNING |<p>**Depends on**:</p><p>- {#PSU_LOCATION}: Power supply is in critical state</p> |
+|{HOST.NAME} has been restarted (uptime < 10m) |<p>Uptime is less than 10 minutes</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.uptime[sysUpTime.0])<10m` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/Cisco UCS Manager SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
+|{#UNIT_LOCATION}: System status is in critical state |<p>Please check the device for errors</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"computeFailed"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"configFailure"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"unconfigFailure"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"inoperable"}` |HIGH | |
+|{#UNIT_LOCATION}: System status is in warning state |<p>Please check the device for warnings</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"testFailed"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"thermalProblem"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"powerProblem"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"voltageProblem"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"diagnosticsFailed"}` |WARNING |<p>**Depends on**:</p><p>- {#UNIT_LOCATION}: System status is in critical state</p> |
+|{#SENSOR_LOCATION}.Ambient: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}`<p>Recovery expression:</p>`max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p> |
+|{#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}`<p>Recovery expression:</p>`max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3` |HIGH | |
+|{#SENSOR_LOCATION}.Front: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}`<p>Recovery expression:</p>`max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p> |
+|{#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}`<p>Recovery expression:</p>`max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3` |HIGH | |
+|{#SENSOR_LOCATION}.Rear: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}`<p>Recovery expression:</p>`max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p> |
+|{#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}`<p>Recovery expression:</p>`max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3` |HIGH | |
+|{#SENSOR_LOCATION}.IOH: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}`<p>Recovery expression:</p>`max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p><p>- {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}</p> |
+|{#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}`<p>Recovery expression:</p>`max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3` |HIGH | |
+|{#SENSOR_LOCATION}: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"CPU"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"CPU"}`<p>Recovery expression:</p>`max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"CPU"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_LOCATION}: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"CPU"}</p> |
+|{#SENSOR_LOCATION}: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"CPU"} |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"CPU"}`<p>Recovery expression:</p>`max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"CPU"}-3` |HIGH | |
+|{#VDISK_LOCATION}: Virtual disk is not in OK state |<p>Please check virtual disk for warnings or errors</p> |`last(/Cisco UCS Manager SNMP/cisco.ucs.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}])<>{$VDISK.STATUS.OK:"equipped"}` |WARNING | |