zabbix_export: version: '6.2' date: '2022-06-07T19:37:44Z' template_groups: - uuid: e960332b3f6c46a1956486d4f3f99fce name: 'Templates/Server hardware' templates: - uuid: d5eb4ce08a334098a85e6e02c534be90 template: 'Cisco UCS Manager SNMP' name: 'Cisco UCS Manager SNMP' description: | This is a template for Cisco UCS Manager monitoring via Zabbix SNMP Agent that works without any external scripts. MIBs used: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB SNMPv2-MIB CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB CISCO-UNIFIED-COMPUTING-STORAGE-MIB IF-MIB You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/418396-discussion-thread-for-official-zabbix-templates-for-cisco Template tooling version used: 0.41 groups: - name: 'Templates/Server hardware' items: - uuid: ad342e11ce9f4f79bf9b0182c3f83488 name: 'System contact details' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.4.0 key: 'cisco.ucs.contact[sysContact.0]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. inventory_link: CONTACT preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 12h tags: - tag: component value: system - uuid: 286fdb0fa49a4b378a6219a5ed76aac4 name: 'System description' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.1.0 key: 'cisco.ucs.descr[sysDescr.0]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 12h tags: - tag: component value: system - uuid: 88bd32f8520144858a8ddb03dd200638 name: 'System location' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.6.0 key: 'cisco.ucs.location[sysLocation.0]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. inventory_link: LOCATION preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 12h tags: - tag: component value: system - uuid: 8bd3a60e4c70450492432c6abfa7b5f9 name: 'System name' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.5.0 key: 'cisco.ucs.name[sysName.0]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. inventory_link: NAME preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 12h tags: - tag: component value: system triggers: - uuid: 622ac72c0e534bba94bb93636e4dc103 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.name[sysName.0],#1)<>last(/Cisco UCS Manager SNMP/cisco.ucs.name[sysName.0],#2) and length(last(/Cisco UCS Manager SNMP/cisco.ucs.name[sysName.0]))>0' name: 'System name has changed' event_name: 'System name has changed (new name: {ITEM.VALUE})' priority: INFO description: 'System name has changed. Ack to close.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 10d22e53318347658b2418ff33c26e0d name: 'System object ID' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.2.0 key: 'cisco.ucs.objectid[sysObjectID.0]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining 'what kind of box' is being managed. For example, if vendor 'Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its 'Fred Router'. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 12h tags: - tag: component value: system - uuid: b87e425f1bdf404a8e53ff277c0ff0c0 name: Uptime type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.3.0 key: 'cisco.ucs.uptime[sysUpTime.0]' delay: 30s history: 2w trends: 0d units: uptime description: | MIB: SNMPv2-MIB The time in seconds since the network management portion of the system was last re-initialized. preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: component value: system triggers: - uuid: 9026e680b409424e8fa29934878cb771 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.uptime[sysUpTime.0])<10m' name: 'has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - name: 'No SNMP data collection' expression: 'max(/Cisco UCS Manager SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' tags: - tag: scope value: notice - uuid: 5d839f68b6534dc8bd1fb5db7a757f02 name: 'SNMP traps (fallback)' type: SNMP_TRAP key: snmptrap.fallback history: 2w trends: '0' value_type: LOG description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items' logtimefmt: 'hh:mm:sszyyyy/MM/dd' tags: - tag: component value: network - uuid: 0926417e279a4e52a7f12587e9422e92 name: 'SNMP agent availability' type: INTERNAL key: 'zabbix[host,snmp,available]' history: 7d description: | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible value: 0 - not available 1 - available 2 - unknown valuemap: name: zabbix.host.available preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h tags: - tag: component value: health - tag: component value: network triggers: - uuid: 010a749e3a3242cd8e3ea30459fae5a4 expression: 'max(/Cisco UCS Manager SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.' tags: - tag: scope value: availability discovery_rules: - uuid: f44bb3e5a8ad4d0c98df56267700b171 name: 'Array controller cache discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#DISKARRAY_CACHE_LOCATION},1.3.6.1.4.1.9.9.719.1.45.11.1.2]' key: cisco.ucs.array.cache.discovery delay: 1h description: 'Scanning table of Array controllers: CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerTable.' item_prototypes: - uuid: 4e5214066fbb4c719c7e6abfba47e5f6 name: '{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.11.1.9.{#SNMPINDEX}' key: 'cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}]' history: 1w trends: 0d description: 'MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB' valuemap: name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: array - tag: component value: disk - tag: component value: storage trigger_prototypes: - uuid: 0300b4bf4e0b42adb1b9e4985e80e356 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' name: '{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 158561ecab8b4bbd9c0a616f419bda10 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' name: '{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is not in optimal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults' dependencies: - name: '{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!' expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' tags: - tag: scope value: availability - tag: scope value: performance - uuid: bd1cf5ecd41f4dc49c6e31f32119787b name: 'Array controller discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#DISKARRAY_LOCATION},1.3.6.1.4.1.9.9.719.1.45.1.1.2]' key: cisco.ucs.array.discovery delay: 1h description: 'Scanning table of Array controllers: CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerTable.' item_prototypes: - uuid: 5285422113b84c2e8cb00899e0b29493 name: '{#DISKARRAY_LOCATION}: Disk array controller model' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.1.1.5.{#SNMPINDEX}' key: 'cisco.ucs.hw.diskarray.model[cucsStorageControllerModel.{#SNMPINDEX}]' delay: 1d trends: '0' value_type: CHAR description: 'MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: array - tag: component value: disk - tag: component value: storage - uuid: a732688d6fa347b597854078dd084935 name: '{#DISKARRAY_LOCATION}: Disk array controller status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.1.1.6.{#SNMPINDEX}' key: 'cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}]' history: 1w trends: 0d description: | MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB Cisco UCS storage:RaidBattery:operability managed object property. valuemap: name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: array - tag: component value: disk - tag: component value: storage trigger_prototypes: - uuid: 28c32222815f47e193d09afe5aafae79 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT:"inoperable"}' name: '{#DISKARRAY_LOCATION}: Disk array controller is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for faults' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 4e758fac4df54388b5f4555bb170bdd3 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN:"degraded"}' name: '{#DISKARRAY_LOCATION}: Disk array controller is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults' dependencies: - name: '{#DISKARRAY_LOCATION}: Disk array controller is in critical state' expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT:"inoperable"}' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 264e15d04626432987c2193bf190c56c expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])>{$DISK.ARRAY.STATUS.OK:"operable"}' name: '{#DISKARRAY_LOCATION}: Disk array controller is not in optimal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults' dependencies: - name: '{#DISKARRAY_LOCATION}: Disk array controller is in critical state' expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT:"inoperable"}' - name: '{#DISKARRAY_LOCATION}: Disk array controller is in warning state' expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN:"degraded"}' tags: - tag: scope value: availability - tag: scope value: performance - uuid: c799941bb99a4ce0af2ab50253c40259 name: 'FAN discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#FAN_LOCATION},1.3.6.1.4.1.9.9.719.1.15.12.1.2]' key: cisco.ucs.fan.discovery delay: 1h item_prototypes: - uuid: 5e4aa59c4ec44fc7b97b9659c0d7a5c5 name: '{#FAN_LOCATION}: Fan status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.15.12.1.9.{#SNMPINDEX}' key: 'cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}]' delay: 3m history: 2w trends: 0d description: | MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB Cisco UCS equipment:Fan:operState managed object property valuemap: name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: fan trigger_prototypes: - uuid: 7417bd7646c248eb9664875d7d19e9ea expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"inoperable"}' name: '{#FAN_LOCATION}: Fan is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the fan unit' tags: - tag: scope value: availability - tag: scope value: performance - uuid: b3d6cb64470e4e4c9bf1d619c0015823 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}])={$FAN.STATUS.WARN:"degraded"}' name: '{#FAN_LOCATION}: Fan is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the fan unit' dependencies: - name: '{#FAN_LOCATION}: Fan is in critical state' expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"inoperable"}' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 20b43c2620114a9da4ff4d97b409f53e name: 'Network interface discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#IFTYPE},1.3.6.1.2.1.2.2.1.3]' key: cisco.ucs.net.if.discovery delay: 1h filter: evaltype: AND conditions: - macro: '{#IFADMINSTATUS}' value: '{$NET.IFADMINSTATUS.MATCHES}' formulaid: A - macro: '{#IFADMINSTATUS}' value: '{$NET.IFADMINSTATUS.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: B - macro: '{#IFOPERSTATUS}' value: '{$NET.IFOPERSTATUS.MATCHES}' formulaid: I - macro: '{#IFOPERSTATUS}' value: '{$NET.IFOPERSTATUS.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: J - macro: '{#IFNAME}' value: '{$NET.IFNAME.MATCHES}' formulaid: G - macro: '{#IFNAME}' value: '{$NET.IFNAME.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: H - macro: '{#IFDESCR}' value: '{$NET.IFDESCR.MATCHES}' formulaid: E - macro: '{#IFDESCR}' value: '{$NET.IFDESCR.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: F - macro: '{#IFALIAS}' value: '{$NET.IFALIAS.MATCHES}' formulaid: C - macro: '{#IFALIAS}' value: '{$NET.IFALIAS.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: D - macro: '{#IFTYPE}' value: '{$NET.IFTYPE.MATCHES}' formulaid: K - macro: '{#IFTYPE}' value: '{$NET.IFTYPE.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: L description: 'Discovering interfaces from IF-MIB.' item_prototypes: - uuid: 361a4c5a4b04432b84f4e6bfcd7775c6 name: 'Interface {#IFNAME}({#IFALIAS}): Interface description' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.2.{#SNMPINDEX}' key: 'cisco.ucs.if.descr[ifDescr.{#SNMPINDEX}]' delay: 1h history: 7d trends: '0' value_type: CHAR description: | MIB: IF-MIB A textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the interface hardware/software. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 009aeec02b3b46dc93bd52c2f1a4de0a name: 'Interface {#IFNAME}({#IFALIAS}): Broadcast packets received' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.9.{#SNMPINDEX}' key: 'cisco.ucs.if.in.broadcast[ifHCInBroadcastPkts.{#SNMPINDEX}]' delay: 3m history: 7d description: | MIB: IF-MIB The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a broadcast address at this sub-layer. This object is a 64-bit version of ifInBroadcastPkts. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 533b7352983e4adfbd9ca1c0e2e5e4b1 name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}' key: 'cisco.ucs.if.in.discards[ifInDiscards.{#SNMPINDEX}]' delay: 3m history: 7d description: | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 84e21f59350248c185a79dd916587140 name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}' key: 'cisco.ucs.if.in.errors[ifInErrors.{#SNMPINDEX}]' delay: 3m history: 7d description: | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: d72b570e01f5479db47628e399932988 name: 'Interface {#IFNAME}({#IFALIAS}): Multicast packets received' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.8.{#SNMPINDEX}' key: 'cisco.ucs.if.in.multicast[ifHCInMulticastPkts.{#SNMPINDEX}]' delay: 3m history: 7d description: | MIB: IF-MIB The number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a multicast address at this sub-layer. For a MAC layer protocol, this includes both Group and Functional addresses. This object is a 64-bit version of ifInMulticastPkts. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: eef7c3f6945a48e886de08a842c08f72 name: 'Interface {#IFNAME}({#IFALIAS}): Bits received' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}' key: 'cisco.ucs.if.in[ifHCInOctets.{#SNMPINDEX}]' delay: 3m history: 7d units: bps description: | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' - type: MULTIPLIER parameters: - '8' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: f682fdf3144145f3998066a77353c4e2 name: 'Interface {#IFNAME}({#IFALIAS}): Broadcast packets sent' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.13.{#SNMPINDEX}' key: 'cisco.ucs.if.out.broadcast[ifHCOutBroadcastPkts.{#SNMPINDEX}]' delay: 3m history: 7d description: | MIB: IF-MIB The total number of packets that higher-level protocols requested be transmitted, and which were addressed to a broadcast address at this sub-layer, including those that were discarded or not sent. This object is a 64-bit version of ifOutBroadcastPkts. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: b61c1b8a08aa40d696d03ae584230e8e name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}' key: 'cisco.ucs.if.out.discards[ifOutDiscards.{#SNMPINDEX}]' delay: 3m history: 7d description: | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 0b9d7feb75674225ac8e6ad0952380ac name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}' key: 'cisco.ucs.if.out.errors[ifOutErrors.{#SNMPINDEX}]' delay: 3m history: 7d description: | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 3ddc4cca78f14dfc8e6d51efae831ba2 name: 'Interface {#IFNAME}({#IFALIAS}): Multicast packets sent' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.12.{#SNMPINDEX}' key: 'cisco.ucs.if.out.multicast[ifHCOutMulticastPkts.{#SNMPINDEX}]' delay: 3m history: 7d description: | MIB: IF-MIB The total number of packets that higher-level protocols requested be transmitted, and which were addressed to a multicast address at this sub-layer, including those that were discarded or not sent. For a MAC layer protocol, this includes both Group and Functional addresses. This object is a 64-bit version of ifOutMulticastPkts. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: e48a1926828645c49afec898d01fa81a name: 'Interface {#IFNAME}({#IFALIAS}): Bits sent' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}' key: 'cisco.ucs.if.out[ifHCOutOctets.{#SNMPINDEX}]' delay: 3m history: 7d units: bps description: | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' - type: MULTIPLIER parameters: - '8' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 56aa529b14b14f6f8f9a9b5f1a2ba0d8 name: 'Interface {#IFNAME}({#IFALIAS}): Speed' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.31.1.1.1.15.{#SNMPINDEX}' key: 'cisco.ucs.if.speed[ifHighSpeed.{#SNMPINDEX}]' delay: 5m history: 7d trends: 0d units: bps description: | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero. preprocessing: - type: MULTIPLIER parameters: - '1000000' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 16a4394c6b824bacbc7f074d487fcdfb name: 'Interface {#IFNAME}({#IFALIAS}): Operational status' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}' key: 'cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}]' history: 7d trends: '0' description: | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. valuemap: name: 'IF-MIB::ifOperStatus' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' trigger_prototypes: - uuid: edfbf339b2664fae88e2a9003383e37f expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}],#2))' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' name: 'Interface {#IFNAME}({#IFALIAS}): Link down' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: | This trigger expression works as follows: 1. Can be triggered if operations status is down. 2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down. 3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.) WARNING: if closed manually - won't fire again on next poll, because of .diff. manual_close: 'YES' tags: - tag: scope value: availability - uuid: 00b0f0fb6c0b4026b438627edab908fb name: 'Interface {#IFNAME}({#IFALIAS}): Interface type' type: SNMP_AGENT snmp_oid: '1.3.6.1.2.1.2.2.1.3.{#SNMPINDEX}' key: 'cisco.ucs.if.type[ifType.{#SNMPINDEX}]' delay: 1h history: 7d trends: 0d description: | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. valuemap: name: 'IF-MIB::ifType' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' trigger_prototypes: - uuid: caaa61b8d89540c496678d739610ae38 expression: | min(/Cisco UCS Manager SNMP/cisco.ucs.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Cisco UCS Manager SNMP/cisco.ucs.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} name: 'Interface {#IFNAME}({#IFALIAS}): High error rate on {#IFNAME}' event_name: 'Interface {#IFNAME}({#IFALIAS}): High error rate on {#IFNAME} ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)' opdata: 'errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}' priority: WARNING description: 'Recovers when value below {$IF.ERRORS.WARN:"{#IFNAME}"} threshold.' manual_close: 'YES' dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}],#2))' recovery_expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' tags: - tag: scope value: performance graph_prototypes: - uuid: d5e5f60602cc41ba8e0b79a63644bf08 name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic' graph_items: - drawtype: GRADIENT_LINE color: 1A7C11 item: host: 'Cisco UCS Manager SNMP' key: 'cisco.ucs.if.in[ifHCInOctets.{#SNMPINDEX}]' - sortorder: '1' drawtype: BOLD_LINE color: 2774A4 item: host: 'Cisco UCS Manager SNMP' key: 'cisco.ucs.if.out[ifHCOutOctets.{#SNMPINDEX}]' - sortorder: '2' color: F63100 yaxisside: RIGHT item: host: 'Cisco UCS Manager SNMP' key: 'cisco.ucs.if.out.errors[ifOutErrors.{#SNMPINDEX}]' - sortorder: '3' color: A54F10 yaxisside: RIGHT item: host: 'Cisco UCS Manager SNMP' key: 'cisco.ucs.if.in.errors[ifInErrors.{#SNMPINDEX}]' - sortorder: '4' color: FC6EA3 yaxisside: RIGHT item: host: 'Cisco UCS Manager SNMP' key: 'cisco.ucs.if.out.discards[ifOutDiscards.{#SNMPINDEX}]' - sortorder: '5' color: 6C59DC yaxisside: RIGHT item: host: 'Cisco UCS Manager SNMP' key: 'cisco.ucs.if.in.discards[ifInDiscards.{#SNMPINDEX}]' preprocessing: - type: JAVASCRIPT parameters: - | var result = []; JSON.parse(value).forEach(function (netif) { if (typeof netif["{#IFNAME}"] === 'undefined') { netif["{#IFNAME}"] = netif["{#IFDESCR}"]; } if (typeof netif["{#IFALIAS}"] === 'undefined') { netif["{#IFALIAS}"] = ""; } result.push(netif); }); return JSON.stringify(result); - uuid: a8794333ae2c4104ac52c6ce421161fd name: 'Physical disk discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#DISK_LOCATION},1.3.6.1.4.1.9.9.719.1.45.4.1.2]' key: cisco.ucs.physicalDisk.discovery delay: 1h description: 'Scanning table of physical drive entries CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskTable.' item_prototypes: - uuid: 3a1f21ccf92f43df869f66911ab5c0ea name: '{#DISK_LOCATION}: Physical disk media type' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.4.1.17.{#SNMPINDEX}' key: 'cisco.ucs.hw.physicaldisk.media_type[cucsStorageLocalDiskDeviceType.{#SNMPINDEX}]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB Cisco UCS storage:LocalDisk:deviceType managed object property. Actually returns 'HDD' or 'SSD'. valuemap: name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageTechnology' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: disk - tag: component value: storage - uuid: 317d489e9bf94467a228f5bbccb03436 name: '{#DISK_LOCATION}: Physical disk model name' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.4.1.7.{#SNMPINDEX}' key: 'cisco.ucs.hw.physicaldisk.model[cucsStorageLocalDiskModel.{#SNMPINDEX}]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB Cisco UCS storage:LocalDisk:model managed object property. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: disk - tag: component value: storage - uuid: d768239496f2457fbec3a1103e84914d name: '{#DISK_LOCATION}: Physical disk serial number' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.4.1.12.{#SNMPINDEX}' key: 'cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}]' delay: 1h trends: '0' value_type: CHAR description: | MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB Cisco UCS storage:LocalDisk:serial managed object property. Actually returns part number code. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: disk - tag: component value: storage trigger_prototypes: - uuid: 693cdcf58cb34def90ade23e2f2485cb expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}],#2) and length(last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}]))>0' name: '{#DISK_LOCATION}: Disk has been replaced' event_name: '{#DISK_LOCATION}: Disk has been replaced (new serial number received)' priority: INFO description: 'Disk serial number has changed. Ack to close' manual_close: 'YES' tags: - tag: scope value: notice - uuid: c3c38ffc10fb4d139099c551b3c21728 name: '{#DISK_LOCATION}: Disk size' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.4.1.13.{#SNMPINDEX}' key: 'cisco.ucs.hw.physicaldisk.size[cucsStorageLocalDiskSize.{#SNMPINDEX}]' delay: 1h history: 2w trends: 0d units: B description: | MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB Cisco UCS storage:LocalDisk:size managed object property. In MB. preprocessing: - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: disk - tag: component value: storage - uuid: ad4616916d6644f480a2687dbc56a4a3 name: '{#DISK_LOCATION}: Physical disk status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.4.1.18.{#SNMPINDEX}' key: 'cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}]' delay: 3m trends: 0d description: | MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB Cisco UCS storage:LocalDisk:diskState managed object property. valuemap: name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStoragePDriveStatus' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: disk - tag: component value: storage trigger_prototypes: - uuid: ba92b99606fa4bf0bc4f1b6a362c2cdb expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.CRIT:"bad"} or last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.CRIT:"predictiveFailure"}' name: '{#DISK_LOCATION}: Physical disk error' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check physical disk for warnings or errors' dependencies: - name: '{#DISK_LOCATION}: Physical disk failed' expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"failed"}' tags: - tag: scope value: availability - tag: scope value: performance - uuid: eabf5aa62f004a2c996cc11bb5a6716a expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"failed"}' name: '{#DISK_LOCATION}: Physical disk failed' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check physical disk for warnings or errors' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 8ac363db6f2346bba13b63f75cdabd22 name: 'PSU discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#PSU_LOCATION},1.3.6.1.4.1.9.9.719.1.15.56.1.2]' key: cisco.ucs.psu.discovery delay: 1h item_prototypes: - uuid: 88a07d360c42431ba4ef31cbe825dc72 name: '{#PSU_LOCATION}: Power supply status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.15.56.1.7.{#SNMPINDEX}' key: 'cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}]' delay: 3m history: 2w trends: 0d description: | MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB Cisco UCS equipment:Psu:operState managed object property valuemap: name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: power trigger_prototypes: - uuid: 0d2713cf2b72472c8d8896880476c20e expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"inoperable"}' name: '{#PSU_LOCATION}: Power supply is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the power supply unit for errors' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 468f08407a7448a384e5dcde589cb9d0 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}])={$PSU.STATUS.WARN:"degraded"}' name: '{#PSU_LOCATION}: Power supply is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the power supply unit for errors' dependencies: - name: '{#PSU_LOCATION}: Power supply is in critical state' expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"inoperable"}' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 90b24337c3304ff6a30428c7d46c26fd name: 'Temperature CPU discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SENSOR_LOCATION},1.3.6.1.4.1.9.9.719.1.41.2.1.2]' key: cisco.ucs.temp.cpu.discovery delay: 1h item_prototypes: - uuid: 7b822aeed3e24358aace9693e7f03385 name: '{#SENSOR_LOCATION}: Temperature' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.41.2.1.10.{#SNMPINDEX}' key: 'cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}]' delay: 3m value_type: FLOAT units: °C description: | MIB: CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB Cisco UCS processor:EnvStats:temperature managed object property preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: temperature trigger_prototypes: - uuid: c3b3933ceb504207a87054a1f9773a76 expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"CPU"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"CPU"}-3' name: '{#SENSOR_LOCATION}: Temperature is above critical threshold' event_name: '{#SENSOR_LOCATION}: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"CPU"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 13b393265f59431687b776297cb0b104 expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"CPU"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"CPU"}-3' name: '{#SENSOR_LOCATION}: Temperature is above warning threshold' event_name: '{#SENSOR_LOCATION}: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"CPU"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' dependencies: - name: '{#SENSOR_LOCATION}: Temperature is above critical threshold' expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"CPU"}' recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"CPU"}-3' tags: - tag: scope value: availability - tag: scope value: performance - uuid: b99a5c977c32418ea9efded6d507e3b5 name: 'Temperature discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SENSOR_LOCATION},1.3.6.1.4.1.9.9.719.1.9.44.1.2]' key: cisco.ucs.temp.discovery delay: 1h item_prototypes: - uuid: d57481cb764a429f928aa6de6837c4ae name: '{#SENSOR_LOCATION}.IOH: Temperature' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.9.44.1.13.{#SNMPINDEX}' key: 'cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}]' delay: 3m value_type: FLOAT units: °C description: | MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB Cisco UCS compute:RackUnitMbTempStats:ioh1Temp managed object property preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: temperature trigger_prototypes: - uuid: aa4bf1c8b942462dbd21ccf8bd8c4a6b expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3' name: '{#SENSOR_LOCATION}.IOH: Temperature is above critical threshold' event_name: '{#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 7751dd6bf1394daa9d918005d2d99d10 expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3' name: '{#SENSOR_LOCATION}.IOH: Temperature is above warning threshold' event_name: '{#SENSOR_LOCATION}.IOH: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' dependencies: - name: '{#SENSOR_LOCATION}.IOH: Temperature is above critical threshold' expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}' recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3' tags: - tag: scope value: availability - tag: scope value: performance - uuid: d5e4b5b7e18c4545853c48db018dc127 name: '{#SENSOR_LOCATION}.Ambient: Temperature' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.9.44.1.4.{#SNMPINDEX}' key: 'cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}]' delay: 3m value_type: FLOAT units: °C description: | MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB Temperature readings of testpoint: {#SENSOR_LOCATION}.Ambient preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: temperature trigger_prototypes: - uuid: 230958b560374a118857b77418c6ba11 expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3' name: '{#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold' event_name: '{#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 4cdcddd04b0e4625893a1e20ce22a10f expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3' name: '{#SENSOR_LOCATION}.Ambient: Temperature is above warning threshold' event_name: '{#SENSOR_LOCATION}.Ambient: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' dependencies: - name: '{#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold' expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}' recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 9980042de8d74353bf4a386bb0f28d30 name: '{#SENSOR_LOCATION}.Front: Temperature' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.9.44.1.8.{#SNMPINDEX}' key: 'cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}]' delay: 3m value_type: FLOAT units: °C description: | MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB Cisco UCS compute:RackUnitMbTempStats:frontTemp managed object property preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: temperature trigger_prototypes: - uuid: 8ee1dfc360aa4aca84a03b452ead92ce expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3' name: '{#SENSOR_LOCATION}.Front: Temperature is above critical threshold' event_name: '{#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 196c9fe3facf4e3db348337714c77e17 expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3' name: '{#SENSOR_LOCATION}.Front: Temperature is above warning threshold' event_name: '{#SENSOR_LOCATION}.Front: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' dependencies: - name: '{#SENSOR_LOCATION}.Front: Temperature is above critical threshold' expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}' recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3' tags: - tag: scope value: availability - tag: scope value: performance - uuid: e20bfa52f31f4a1a9f08ba02fe27f90c name: '{#SENSOR_LOCATION}.Rear: Temperature' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.9.44.1.21.{#SNMPINDEX}' key: 'cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}]' delay: 3m value_type: FLOAT units: °C description: | MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB Cisco UCS compute:RackUnitMbTempStats:rearTemp managed object property preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: temperature trigger_prototypes: - uuid: a8714fcba51c46f9aa84fa02fba37743 expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3' name: '{#SENSOR_LOCATION}.Rear: Temperature is above critical threshold' event_name: '{#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 87068c693e574cd3952ca90e95a7a681 expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3' name: '{#SENSOR_LOCATION}.Rear: Temperature is above warning threshold' event_name: '{#SENSOR_LOCATION}.Rear: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' dependencies: - name: '{#SENSOR_LOCATION}.Rear: Temperature is above critical threshold' expression: 'avg(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}' recovery_expression: 'max(/Cisco UCS Manager SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 9c5d5ce2f672487db83cf91f22c1a413 name: 'Unit discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#UNIT_LOCATION},1.3.6.1.4.1.9.9.719.1.9.35.1.2]' key: cisco.ucs.unit.discovery delay: 1h item_prototypes: - uuid: 41ecc1caac444d2587d51e33057e6d39 name: '{#UNIT_LOCATION}: Hardware model name' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.9.35.1.32.{#SNMPINDEX}' key: 'cisco.ucs.hw.model[cucsComputeRackUnitModel.{#SNMPINDEX}]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB Cisco UCS compute:RackUnit:model managed object property preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: ac3217187db3453eb8b9932fce7c79c4 name: '{#UNIT_LOCATION}: Hardware serial number' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.9.35.1.47.{#SNMPINDEX}' key: 'cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB Cisco UCS compute:RackUnit:serial managed object property preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system trigger_prototypes: - uuid: 27253665837647bb9c3be58f7d0881ae expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager SNMP/cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}],#2) and length(last(/Cisco UCS Manager SNMP/cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]))>0' name: '{#UNIT_LOCATION}: Device has been replaced' event_name: '{#UNIT_LOCATION}: Device has been replaced (new serial number received)' priority: INFO description: 'Device serial number has changed. Ack to close' manual_close: 'YES' tags: - tag: scope value: notice - uuid: c6ebb7db809f4c62aae795a8b1c4b740 name: '{#UNIT_LOCATION}: Overall system health status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.9.35.1.42.{#SNMPINDEX}' key: 'cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}]' delay: 30s history: 2w trends: 0d description: | MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB Cisco UCS compute:RackUnit:operState managed object property valuemap: name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsLsOperState' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system trigger_prototypes: - uuid: 7f7c337f4f9f44a3a176acce5bf27f29 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"computeFailed"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"configFailure"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"unconfigFailure"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"inoperable"}' name: '{#UNIT_LOCATION}: System status is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for errors' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 15ee6a98f2af4da4bcaa95821ffff524 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"testFailed"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"thermalProblem"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"powerProblem"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"voltageProblem"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"diagnosticsFailed"}' name: '{#UNIT_LOCATION}: System status is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for warnings' dependencies: - name: '{#UNIT_LOCATION}: System status is in critical state' expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"computeFailed"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"configFailure"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"unconfigFailure"} or last(/Cisco UCS Manager SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"inoperable"}' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 6d0760c4d29d4113b179b0e5c18f7e3b name: 'Virtual disk discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#VDISK_LOCATION},1.3.6.1.4.1.9.9.719.1.45.8.1.2]' key: cisco.ucs.virtualDisk.discovery delay: 1h description: 'CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalLunTable' item_prototypes: - uuid: c80f07f350bc472fb73282f5c80e16e3 name: '{#VDISK_LOCATION}: Layout type' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.8.1.14.{#SNMPINDEX}' key: 'cisco.ucs.hw.virtualdisk.layout[cucsStorageLocalLunType.{#SNMPINDEX}]' delay: 1h history: 2w description: | MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB Cisco UCS storage:LocalLun:type managed object property valuemap: name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: disk - tag: component value: storage - uuid: 59a403629e8b40d981c2926ead601966 name: '{#VDISK_LOCATION}: Disk size' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.8.1.13.{#SNMPINDEX}' key: 'cisco.ucs.hw.virtualdisk.size[cucsStorageLocalLunSize.{#SNMPINDEX}]' delay: 1h history: 2w trends: 0d units: B description: | MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB Cisco UCS storage:LocalLun:size managed object property in MB. valuemap: name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType' preprocessing: - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: disk - tag: component value: storage - uuid: 39504e417781414081e1198adef562d4 name: '{#VDISK_LOCATION}: Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.9.9.719.1.45.8.1.10.{#SNMPINDEX}' key: 'cisco.ucs.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}]' delay: 3m history: 2w description: | MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB Cisco UCS storage:LocalLun:presence managed object property valuemap: name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentPresence' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: disk - tag: component value: storage trigger_prototypes: - uuid: 63232b4e1f6b411a93ff8abad1ff3200 expression: 'last(/Cisco UCS Manager SNMP/cisco.ucs.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}])<>{$VDISK.STATUS.OK:"equipped"}' name: '{#VDISK_LOCATION}: Virtual disk is not in OK state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check virtual disk for warnings or errors' tags: - tag: scope value: availability - tag: scope value: performance tags: - tag: class value: hardware - tag: target value: cisco - tag: target value: cisco-ucs-manager macros: - macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' value: '2' description: 'The cache battery critical state for trigger expression.' - macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' value: '1' description: 'The cache battery normal state for trigger expression.' - macro: '{$DISK.ARRAY.STATUS.CRIT:"inoperable"}' value: '2' description: 'The array controller critical state for trigger expression.' - macro: '{$DISK.ARRAY.STATUS.OK:"operable"}' value: '1' description: 'The array controller normal state for trigger expression.' - macro: '{$DISK.ARRAY.STATUS.WARN:"degraded"}' value: '3' description: 'The array controller warning state for trigger expression.' - macro: '{$DISK.STATUS.CRIT:"bad"}' value: '16' description: 'The disk critical state for trigger expression.' - macro: '{$DISK.STATUS.CRIT:"predictiveFailure"}' value: '11' description: 'The disk critical state for trigger expression.' - macro: '{$DISK.STATUS.FAIL:"failed"}' value: '9' description: 'The disk fail state for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"inoperable"}' value: '2' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.WARN:"degraded"}' value: '3' description: 'The warning value of the FAN sensor for trigger expression.' - macro: '{$HEALTH.STATUS.CRIT:"computeFailed"}' value: '30' description: 'The unit health critical state for trigger expression.' - macro: '{$HEALTH.STATUS.CRIT:"configFailure"}' value: '33' description: 'The unit health critical state for trigger expression.' - macro: '{$HEALTH.STATUS.CRIT:"inoperable"}' value: '60' description: 'The unit health critical state for trigger expression.' - macro: '{$HEALTH.STATUS.CRIT:"unconfigFailure"}' value: '34' description: 'The unit health critical state for trigger expression.' - macro: '{$HEALTH.STATUS.WARN:"diagnosticsFailed"}' value: '204' description: 'The unit health warning state for trigger expression.' - macro: '{$HEALTH.STATUS.WARN:"powerProblem"}' value: '62' description: 'The unit health warning state for trigger expression.' - macro: '{$HEALTH.STATUS.WARN:"testFailed"}' value: '35' description: 'The unit health warning state for trigger expression.' - macro: '{$HEALTH.STATUS.WARN:"thermalProblem"}' value: '60' description: 'The unit health warning state for trigger expression.' - macro: '{$HEALTH.STATUS.WARN:"voltageProblem"}' value: '62' description: 'The unit health warning state for trigger expression.' - macro: '{$IF.ERRORS.WARN}' value: '2' - macro: '{$IFCONTROL}' value: '1' - macro: '{$NET.IFADMINSTATUS.MATCHES}' value: '^.*' description: 'This macro is used in network interface discovery. Can be overridden on the host level. Ignore notPresent(6) by default.' - macro: '{$NET.IFADMINSTATUS.NOT_MATCHES}' value: ^2$ description: 'This macro is used in network interface discovery. Can be overridden on the host level. Ignore down(2) administrative status by default.' - macro: '{$NET.IFALIAS.MATCHES}' value: '.*' description: 'This macro is used in network interface discovery. Can be overridden on the host level.' - macro: '{$NET.IFALIAS.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'This macro is used in network interface discovery. Can be overridden on the host level.' - macro: '{$NET.IFDESCR.MATCHES}' value: '.*' description: 'This macro is used in network interface discovery. Can be overridden on the host level.' - macro: '{$NET.IFDESCR.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'This macro is used in network interface discovery. Can be overridden on the host level.' - macro: '{$NET.IFNAME.MATCHES}' value: '^.*$' description: 'This macro is used in network interface discovery. Can be overridden on the host level.' - macro: '{$NET.IFNAME.NOT_MATCHES}' value: '(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12}|sup-fc0)' description: 'This macro is used in network interface discovery. Can be overridden on the host level. Filter out loopbacks, sup-fc0, nulls, docker veth links and docker0 bridge by default.' - macro: '{$NET.IFOPERSTATUS.MATCHES}' value: '^.*$' description: 'This macro is used in network interface discovery. Can be overridden on the host level.' - macro: '{$NET.IFOPERSTATUS.NOT_MATCHES}' value: ^6$ description: 'This macro is used in network interface discovery. Can be overridden on the host level. Ignore notPresent(6) by default.' - macro: '{$NET.IFTYPE.MATCHES}' value: '.*' description: 'This macro is used in network interface discovery. Can be overridden on the host level.' - macro: '{$NET.IFTYPE.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'This macro is used in network interface discovery. Can be overridden on the host level.' - macro: '{$PSU.STATUS.CRIT:"inoperable"}' value: '2' description: 'The critical value of the PSU sensor for trigger expression.' - macro: '{$PSU.STATUS.WARN:"degraded"}' value: '3' description: 'The warning value of the PSU sensor for trigger expression.' - macro: '{$SNMP.TIMEOUT}' value: 5m description: 'The time interval for SNMP agent availability trigger expression.' - macro: '{$TEMP.MAX.CRIT:"Ambient"}' value: '35' description: 'The temperature maximum critical value for trigger expression.' - macro: '{$TEMP.MAX.WARN:"Ambient"}' value: '30' description: 'The temperature maximum warning value for trigger expression.' - macro: '{$VDISK.STATUS.OK:"equipped"}' value: '10' description: 'The vdisk normal state for trigger expression.' dashboards: - uuid: b28e8cdadce64ba299c56054a18ea31d name: 'Network interfaces' pages: - widgets: - type: GRAPH_PROTOTYPE width: '24' height: '5' fields: - type: INTEGER name: source_type value: '2' - type: INTEGER name: columns value: '1' - type: INTEGER name: rows value: '1' - type: GRAPH_PROTOTYPE name: graphid value: host: 'Cisco UCS Manager SNMP' name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic' valuemaps: - uuid: 8648df22d8be42359900e11ea395a98c name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability' mappings: - value: '0' newvalue: unknown - value: '1' newvalue: operable - value: '2' newvalue: inoperable - value: '3' newvalue: degraded - value: '4' newvalue: poweredOff - value: '5' newvalue: powerProblem - value: '6' newvalue: removed - value: '7' newvalue: voltageProblem - value: '8' newvalue: thermalProblem - value: '9' newvalue: performanceProblem - value: '10' newvalue: accessibilityProblem - value: '11' newvalue: identityUnestablishable - value: '12' newvalue: biosPostTimeout - value: '13' newvalue: disabled - value: '14' newvalue: malformedFru - value: '15' newvalue: backplanePortProblem - value: '16' newvalue: chassisIntrusion - value: '51' newvalue: fabricConnProblem - value: '52' newvalue: fabricUnsupportedConn - value: '81' newvalue: config - value: '82' newvalue: equipmentProblem - value: '83' newvalue: decommissioning - value: '84' newvalue: chassisLimitExceeded - value: '100' newvalue: notSupported - value: '101' newvalue: discovery - value: '102' newvalue: discoveryFailed - value: '103' newvalue: identify - value: '104' newvalue: postFailure - value: '105' newvalue: upgradeProblem - value: '106' newvalue: peerCommProblem - value: '107' newvalue: autoUpgrade - value: '108' newvalue: linkActivateBlocked - uuid: 17dde900e96a47929b0abed0d5006c84 name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentPresence' mappings: - value: '0' newvalue: unknown - value: '1' newvalue: empty - value: '10' newvalue: equipped - value: '11' newvalue: missing - value: '12' newvalue: mismatch - value: '13' newvalue: equippedNotPrimary - value: '14' newvalue: equippedSlave - value: '15' newvalue: mismatchSlave - value: '16' newvalue: missingSlave - value: '20' newvalue: equippedIdentityUnestablishable - value: '21' newvalue: mismatchIdentityUnestablishable - value: '22' newvalue: equippedWithMalformedFru - value: '30' newvalue: inaccessible - value: '40' newvalue: unauthorized - value: '100' newvalue: notSupported - value: '101' newvalue: equippedUnsupported - value: '102' newvalue: equippedDiscNotStarted - value: '103' newvalue: equippedDiscInProgress - value: '104' newvalue: equippedDiscError - value: '105' newvalue: equippedDiscUnknown - uuid: c4a3603d4d8944ad8a8d2529bc3f1278 name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsLsOperState' mappings: - value: '0' newvalue: indeterminate - value: '1' newvalue: unassociated - value: '10' newvalue: ok - value: '11' newvalue: discovery - value: '12' newvalue: config - value: '13' newvalue: unconfig - value: '14' newvalue: powerOff - value: '15' newvalue: restart - value: '20' newvalue: maintenance - value: '21' newvalue: test - value: '29' newvalue: computeMismatch - value: '30' newvalue: computeFailed - value: '31' newvalue: degraded - value: '32' newvalue: discoveryFailed - value: '33' newvalue: configFailure - value: '34' newvalue: unconfigFailed - value: '35' newvalue: testFailed - value: '36' newvalue: maintenanceFailed - value: '40' newvalue: removed - value: '41' newvalue: disabled - value: '50' newvalue: inaccessible - value: '60' newvalue: thermalProblem - value: '61' newvalue: powerProblem - value: '62' newvalue: voltageProblem - value: '63' newvalue: inoperable - value: '101' newvalue: decommissioning - value: '201' newvalue: biosRestore - value: '202' newvalue: cmosReset - value: '203' newvalue: diagnostics - value: '204' newvalue: diagnosticsFailed - value: '210' newvalue: pendingReboot - value: '211' newvalue: pendingReassociation - value: '212' newvalue: svnicNotPresent - uuid: 7d09a2b8df18410ca871ed9e7dbe6aa1 name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType' mappings: - value: '0' newvalue: unspecified - value: '1' newvalue: simple - value: '2' newvalue: mirror - value: '3' newvalue: stripe - value: '4' newvalue: raid - value: '5' newvalue: stripeParity - value: '6' newvalue: stripeDualParity - value: '7' newvalue: mirrorStripe - value: '8' newvalue: stripeParityStripe - value: '9' newvalue: stripeDualParityStripe - uuid: 70a906bfe3b447a39e5a0f0ba5210ae2 name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStoragePDriveStatus' mappings: - value: '0' newvalue: unknown - value: '1' newvalue: online - value: '2' newvalue: unconfiguredGood - value: '3' newvalue: globalHotSpare - value: '4' newvalue: dedicatedHotSpare - value: '5' newvalue: jbod - value: '6' newvalue: offline - value: '7' newvalue: rebuilding - value: '8' newvalue: copyback - value: '9' newvalue: failed - value: '10' newvalue: unconfiguredBad - value: '11' newvalue: predictiveFailure - value: '12' newvalue: disabledForRemoval - value: '13' newvalue: foreignConfiguration - value: '14' newvalue: zeroing - value: '15' newvalue: good - value: '16' newvalue: bad - value: '17' newvalue: lockedForeignConfiguration - uuid: e1407fbe331343d3bda7d7eb122c085a name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageTechnology' mappings: - value: '0' newvalue: unspecified - value: '1' newvalue: hdd - value: '2' newvalue: ssd - value: '3' newvalue: nvme - uuid: 2b0fde08268f4ce7b47aae3827ebdf23 name: 'IF-MIB::ifOperStatus' mappings: - value: '1' newvalue: up - value: '2' newvalue: down - value: '3' newvalue: testing - value: '4' newvalue: unknown - value: '5' newvalue: dormant - value: '6' newvalue: notPresent - value: '7' newvalue: lowerLayerDown - uuid: be402fda36e64dd2ad807925755735c4 name: 'IF-MIB::ifType' mappings: - value: '1' newvalue: other - value: '2' newvalue: regular1822 - value: '3' newvalue: hdh1822 - value: '4' newvalue: ddnX25 - value: '5' newvalue: rfc877x25 - value: '6' newvalue: ethernetCsmacd - value: '7' newvalue: iso88023Csmacd - value: '8' newvalue: iso88024TokenBus - value: '9' newvalue: iso88025TokenRing - value: '10' newvalue: iso88026Man - value: '11' newvalue: starLan - value: '12' newvalue: proteon10Mbit - value: '13' newvalue: proteon80Mbit - value: '14' newvalue: hyperchannel - value: '15' newvalue: fddi - value: '16' newvalue: lapb - value: '17' newvalue: sdlc - value: '18' newvalue: ds1 - value: '19' newvalue: e1 - value: '20' newvalue: basicISDN - value: '21' newvalue: primaryISDN - value: '22' newvalue: propPointToPointSerial - value: '23' newvalue: ppp - value: '24' newvalue: softwareLoopback - value: '25' newvalue: eon - value: '26' newvalue: ethernet3Mbit - value: '27' newvalue: nsip - value: '28' newvalue: slip - value: '29' newvalue: ultra - value: '30' newvalue: ds3 - value: '31' newvalue: sip - value: '32' newvalue: frameRelay - value: '33' newvalue: rs232 - value: '34' newvalue: para - value: '35' newvalue: arcnet - value: '36' newvalue: arcnetPlus - value: '37' newvalue: atm - value: '38' newvalue: miox25 - value: '39' newvalue: sonet - value: '40' newvalue: x25ple - value: '41' newvalue: iso88022llc - value: '42' newvalue: localTalk - value: '43' newvalue: smdsDxi - value: '44' newvalue: frameRelayService - value: '45' newvalue: v35 - value: '46' newvalue: hssi - value: '47' newvalue: hippi - value: '48' newvalue: modem - value: '49' newvalue: aal5 - value: '50' newvalue: sonetPath - value: '51' newvalue: sonetVT - value: '52' newvalue: smdsIcip - value: '53' newvalue: propVirtual - value: '54' newvalue: propMultiplexor - value: '55' newvalue: ieee80212 - value: '56' newvalue: fibreChannel - value: '57' newvalue: hippiInterface - value: '58' newvalue: frameRelayInterconnect - value: '59' newvalue: aflane8023 - value: '60' newvalue: aflane8025 - value: '61' newvalue: cctEmul - value: '62' newvalue: fastEther - value: '63' newvalue: isdn - value: '64' newvalue: v11 - value: '65' newvalue: v36 - value: '66' newvalue: g703at64k - value: '67' newvalue: g703at2mb - value: '68' newvalue: qllc - value: '69' newvalue: fastEtherFX - value: '70' newvalue: channel - value: '71' newvalue: ieee80211 - value: '72' newvalue: ibm370parChan - value: '73' newvalue: escon - value: '74' newvalue: dlsw - value: '75' newvalue: isdns - value: '76' newvalue: isdnu - value: '77' newvalue: lapd - value: '78' newvalue: ipSwitch - value: '79' newvalue: rsrb - value: '80' newvalue: atmLogical - value: '81' newvalue: ds0 - value: '82' newvalue: ds0Bundle - value: '83' newvalue: bsc - value: '84' newvalue: async - value: '85' newvalue: cnr - value: '86' newvalue: iso88025Dtr - value: '87' newvalue: eplrs - value: '88' newvalue: arap - value: '89' newvalue: propCnls - value: '90' newvalue: hostPad - value: '91' newvalue: termPad - value: '92' newvalue: frameRelayMPI - value: '93' newvalue: x213 - value: '94' newvalue: adsl - value: '95' newvalue: radsl - value: '96' newvalue: sdsl - value: '97' newvalue: vdsl - value: '98' newvalue: iso88025CRFPInt - value: '99' newvalue: myrinet - value: '100' newvalue: voiceEM - value: '101' newvalue: voiceFXO - value: '102' newvalue: voiceFXS - value: '103' newvalue: voiceEncap - value: '104' newvalue: voiceOverIp - value: '105' newvalue: atmDxi - value: '106' newvalue: atmFuni - value: '107' newvalue: atmIma - value: '108' newvalue: pppMultilinkBundle - value: '109' newvalue: ipOverCdlc - value: '110' newvalue: ipOverClaw - value: '111' newvalue: stackToStack - value: '112' newvalue: virtualIpAddress - value: '113' newvalue: mpc - value: '114' newvalue: ipOverAtm - value: '115' newvalue: iso88025Fiber - value: '116' newvalue: tdlc - value: '117' newvalue: gigabitEthernet - value: '118' newvalue: hdlc - value: '119' newvalue: lapf - value: '120' newvalue: v37 - value: '121' newvalue: x25mlp - value: '122' newvalue: x25huntGroup - value: '123' newvalue: trasnpHdlc - value: '124' newvalue: interleave - value: '125' newvalue: fast - value: '126' newvalue: ip - value: '127' newvalue: docsCableMaclayer - value: '128' newvalue: docsCableDownstream - value: '129' newvalue: docsCableUpstream - value: '130' newvalue: a12MppSwitch - value: '131' newvalue: tunnel - value: '132' newvalue: coffee - value: '133' newvalue: ces - value: '134' newvalue: atmSubInterface - value: '135' newvalue: l2vlan - value: '136' newvalue: l3ipvlan - value: '137' newvalue: l3ipxvlan - value: '138' newvalue: digitalPowerline - value: '139' newvalue: mediaMailOverIp - value: '140' newvalue: dtm - value: '141' newvalue: dcn - value: '142' newvalue: ipForward - value: '143' newvalue: msdsl - value: '144' newvalue: ieee1394 - value: '145' newvalue: if-gsn - value: '146' newvalue: dvbRccMacLayer - value: '147' newvalue: dvbRccDownstream - value: '148' newvalue: dvbRccUpstream - value: '149' newvalue: atmVirtual - value: '150' newvalue: mplsTunnel - value: '151' newvalue: srp - value: '152' newvalue: voiceOverAtm - value: '153' newvalue: voiceOverFrameRelay - value: '154' newvalue: idsl - value: '155' newvalue: compositeLink - value: '156' newvalue: ss7SigLink - value: '157' newvalue: propWirelessP2P - value: '158' newvalue: frForward - value: '159' newvalue: rfc1483 - value: '160' newvalue: usb - value: '161' newvalue: ieee8023adLag - value: '162' newvalue: bgppolicyaccounting - value: '163' newvalue: frf16MfrBundle - value: '164' newvalue: h323Gatekeeper - value: '165' newvalue: h323Proxy - value: '166' newvalue: mpls - value: '167' newvalue: mfSigLink - value: '168' newvalue: hdsl2 - value: '169' newvalue: shdsl - value: '170' newvalue: ds1FDL - value: '171' newvalue: pos - value: '172' newvalue: dvbAsiIn - value: '173' newvalue: dvbAsiOut - value: '174' newvalue: plc - value: '175' newvalue: nfas - value: '176' newvalue: tr008 - value: '177' newvalue: gr303RDT - value: '178' newvalue: gr303IDT - value: '179' newvalue: isup - value: '180' newvalue: propDocsWirelessMaclayer - value: '181' newvalue: propDocsWirelessDownstream - value: '182' newvalue: propDocsWirelessUpstream - value: '183' newvalue: hiperlan2 - value: '184' newvalue: propBWAp2Mp - value: '185' newvalue: sonetOverheadChannel - value: '186' newvalue: digitalWrapperOverheadChannel - value: '187' newvalue: aal2 - value: '188' newvalue: radioMAC - value: '189' newvalue: atmRadio - value: '190' newvalue: imt - value: '191' newvalue: mvl - value: '192' newvalue: reachDSL - value: '193' newvalue: frDlciEndPt - value: '194' newvalue: atmVciEndPt - value: '195' newvalue: opticalChannel - value: '196' newvalue: opticalTransport - value: '197' newvalue: propAtm - value: '198' newvalue: voiceOverCable - value: '199' newvalue: infiniband - value: '200' newvalue: teLink - value: '201' newvalue: q2931 - value: '202' newvalue: virtualTg - value: '203' newvalue: sipTg - value: '204' newvalue: sipSig - value: '205' newvalue: docsCableUpstreamChannel - value: '206' newvalue: econet - value: '207' newvalue: pon155 - value: '208' newvalue: pon622 - value: '209' newvalue: bridge - value: '210' newvalue: linegroup - value: '211' newvalue: voiceEMFGD - value: '212' newvalue: voiceFGDEANA - value: '213' newvalue: voiceDID - value: '214' newvalue: mpegTransport - value: '215' newvalue: sixToFour - value: '216' newvalue: gtp - value: '217' newvalue: pdnEtherLoop1 - value: '218' newvalue: pdnEtherLoop2 - value: '219' newvalue: opticalChannelGroup - value: '220' newvalue: homepna - value: '221' newvalue: gfp - value: '222' newvalue: ciscoISLvlan - value: '223' newvalue: actelisMetaLOOP - value: '224' newvalue: fcipLink - value: '225' newvalue: rpr - value: '226' newvalue: qam - value: '227' newvalue: lmp - value: '228' newvalue: cblVectaStar - value: '229' newvalue: docsCableMCmtsDownstream - value: '230' newvalue: adsl2 - value: '231' newvalue: macSecControlledIF - value: '232' newvalue: macSecUncontrolledIF - value: '233' newvalue: aviciOpticalEther - value: '234' newvalue: atmbond - value: '235' newvalue: voiceFGDOS - value: '236' newvalue: mocaVersion1 - value: '237' newvalue: ieee80216WMAN - value: '238' newvalue: adsl2plus - value: '239' newvalue: dvbRcsMacLayer - value: '240' newvalue: dvbTdm - value: '241' newvalue: dvbRcsTdma - value: '242' newvalue: x86Laps - value: '243' newvalue: wwanPP - value: '244' newvalue: wwanPP2 - value: '245' newvalue: voiceEBS - value: '246' newvalue: ifPwType - value: '247' newvalue: ilan - value: '248' newvalue: pip - value: '249' newvalue: aluELP - value: '250' newvalue: gpon - value: '251' newvalue: vdsl2 - value: '252' newvalue: capwapDot11Profile - value: '253' newvalue: capwapDot11Bss - value: '254' newvalue: capwapWtpVirtualRadio - value: '255' newvalue: bits - value: '256' newvalue: docsCableUpstreamRfPort - value: '257' newvalue: cableDownstreamRfPort - value: '258' newvalue: vmwareVirtualNic - value: '259' newvalue: ieee802154 - value: '260' newvalue: otnOdu - value: '261' newvalue: otnOtu - value: '262' newvalue: ifVfiType - value: '263' newvalue: g9981 - value: '264' newvalue: g9982 - value: '265' newvalue: g9983 - value: '266' newvalue: aluEpon - value: '267' newvalue: aluEponOnu - value: '268' newvalue: aluEponPhysicalUni - value: '269' newvalue: aluEponLogicalLink - value: '270' newvalue: aluGponOnu - value: '271' newvalue: aluGponPhysicalUni - value: '272' newvalue: vmwareNicTeam - value: '277' newvalue: docsOfdmDownstream - value: '278' newvalue: docsOfdmaUpstream - value: '279' newvalue: gfast - value: '280' newvalue: sdci - value: '281' newvalue: xboxWireless - value: '282' newvalue: fastdsl - value: '283' newvalue: docsCableScte55d1FwdOob - value: '284' newvalue: docsCableScte55d1RetOob - value: '285' newvalue: docsCableScte55d2DsOob - value: '286' newvalue: docsCableScte55d2UsOob - value: '287' newvalue: docsCableNdf - value: '288' newvalue: docsCableNdr - value: '289' newvalue: ptm - value: '290' newvalue: ghn - uuid: 9ea529bf28a84fae95f1506ca6ca37b8 name: zabbix.host.available mappings: - value: '0' newvalue: 'not available' - value: '1' newvalue: available - value: '2' newvalue: unknown