zabbix_export: version: '6.2' date: '2022-06-07T19:33:14Z' template_groups: - uuid: e960332b3f6c46a1956486d4f3f99fce name: 'Templates/Server hardware' templates: - uuid: 9fde0e1c36f8453da72f97535d4e74ca template: 'DELL PowerEdge R740 SNMP' name: 'DELL PowerEdge R740 SNMP' description: | Template for DELL PowerEdge R740 servers with iDRAC version 7 and later. MIBs used: IDRAC-MIB-SMIv2 SNMPv2-MIB You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates Template tooling version used: 0.41 groups: - name: 'Templates/Server hardware' items: - uuid: a0886c2161f04d2d9c0611c03cb9f2b3 name: 'Dell R740: System contact details' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.4.0 key: 'dell.server.contact[sysContact]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. inventory_link: CONTACT preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: 48db6854d25c40f2bcbe736cd0d07b38 name: 'Dell R740: System description' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.1.0 key: 'dell.server.descr[sysDescr]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: c32ef141053241cfa8874f9f6b87f2a9 name: 'Dell R740: Firmware version' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.1.1.8.0 key: 'dell.server.hw.firmware[racFirmwareVersion]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the firmware version of a remote access card. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: fc9618eb512e4d9b9eddf21c2700582e expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R740 SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R740 SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0' name: 'Dell R740: Firmware has changed' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: INFO description: 'Firmware version has changed. Ack to close.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: e786d1813aff4098b8b9f75c57e767a0 name: 'Dell R740: Hardware model name' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.1.3.12.0 key: 'dell.server.hw.model[systemModelName]' history: 7d trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the model name of the system. inventory_link: MODEL preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: 07581939572b47c9b1752899e100aefb name: 'Dell R740: Hardware serial number' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.1.3.2.0 key: 'dell.server.hw.serialnumber[systemServiceTag]' history: 7d trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the service tag of the system. inventory_link: SERIALNO_A preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system triggers: - uuid: 21ee92eed6f04ea59864dd09b1fac68a expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R740 SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R740 SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0' name: 'Dell R740: Device has been replaced' event_name: 'Dell R740: Device has been replaced (new serial number received)' priority: INFO description: 'Device serial number has changed. Ack to close' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 774878145ad344408e2cc2c8d7f1eb3b name: 'Dell R740: System location' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.6.0 key: 'dell.server.location[sysLocation]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. inventory_link: LOCATION preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: 3794e08f1f404a18b834e1134ab4b036 name: 'Dell R740: System name' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.5.0 key: 'dell.server.name[sysName]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. inventory_link: NAME preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system triggers: - uuid: edc8087b2d2b423fb637b7caefeb50fb expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R740 SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R740 SNMP/dell.server.name[sysName]))>0' name: 'Dell R740: System name has changed' event_name: 'Dell R740: System name has changed (new name: {ITEM.VALUE})' priority: INFO description: 'System name has changed. Ack to close.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 4d696ff91efc40dd9df759276cfa239e name: 'Dell R740: System object ID' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.2.0 key: 'dell.server.objectid[sysObjectID]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining 'what kind of box' is being managed. For example, if vendor 'Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its 'Fred Router'. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: 0e55ea34eb984e3d8b0ec22f5a8086d2 name: 'Dell R740: Overall system health status' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.2.1.0 key: 'dell.server.status[globalSystemStatus]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc. valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: health - tag: component value: system triggers: - uuid: 2a44b7a84ef84d25a40e58239cc305d1 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.DISASTER}' name: 'Dell R740: System is in unrecoverable state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: DISASTER description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 7efda5ac8a21449ba32ff3f005433fc1 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.CRIT}' name: 'Dell R740: System status is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for errors.' tags: - tag: scope value: availability - uuid: 5d3dd609897a4f9ba644db1916045a6f expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.WARN}' name: 'Dell R740: System status is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for warnings.' dependencies: - name: 'Dell R740: System status is in critical state' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.CRIT}' tags: - tag: scope value: availability - uuid: 869eb1dae24e44c1acdfb128d6080ecd name: 'Dell R740: Operating system' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.1.3.6.0 key: 'dell.server.sw.os[systemOSName]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the name of the operating system that the host is running. inventory_link: OS preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: 9917b5d4d2684398b09ce42842b15146 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R740 SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R740 SNMP/dell.server.sw.os[systemOSName]))>0' name: 'Dell R740: Operating system description has changed' priority: INFO description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Ack to close.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: eea538aa7a344a548b713de22c36beaf name: 'Dell R740: Uptime' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.3.0 key: 'dell.server.uptime[sysUpTime]' history: 2w trends: 0d units: uptime description: | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: component value: system triggers: - uuid: 91449180f6dd435f8104a51ae5645fc3 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.uptime[sysUpTime])<10m' name: 'Dell R740: has been restarted' event_name: 'Dell R740: {HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING description: 'Uptime is less than 10 minutes.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: d829666064144c05b45982114d4b62fe name: 'Dell R740: SNMP traps (fallback)' type: SNMP_TRAP key: snmptrap.fallback history: 2w trends: '0' value_type: LOG description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items' logtimefmt: 'hh:mm:sszyyyy/MM/dd' tags: - tag: component value: network - uuid: 3d357c53b0774e01b286062d9aa4acbe name: 'Dell R740: SNMP agent availability' type: INTERNAL key: 'zabbix[host,snmp,available]' history: 7d valuemap: name: zabbix.host.available preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: health - tag: component value: system triggers: - uuid: 6c5688c758b64c2f91f2523855578be9 expression: 'max(/DELL PowerEdge R740 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'Dell R740: No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.' tags: - tag: scope value: availability discovery_rules: - uuid: f857333511534d31ba074025893d9cc2 name: 'Array controller cache discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#BATTERY_NUM},1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,{#BATTERY_NAME},1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]' key: array.cache.discovery delay: 1h description: 'Scanning table of Array controllers: IDRAC-MIB-SMIv2::batteryTable' item_prototypes: - uuid: be4a3804b89640248fdc06dcfaf497db name: 'Dell R740: {#BATTERY_NAME} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}' key: 'dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 Current state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and needs to be replaced. 4: The battery temperature is high or charge level is depleting. 5: The battery is missing or not detected. 6: The battery is undergoing the re-charge phase. 7: The battery voltage or charge level is below the threshold. valuemap: name: 'IDRAC-MIB-SMIv2::batteryState' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: battery - tag: component value: diskarray trigger_prototypes: - uuid: 19f9217f3d3a4f98a516c3569d35bd21 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' name: 'Dell R740: {#BATTERY_NAME} is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: b89350f48b354abf864372e3210cbb76 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' name: 'Dell R740: {#BATTERY_NAME} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R740: {#BATTERY_NAME} is in critical state' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' tags: - tag: scope value: availability - uuid: df1277db9cae4a10b18d08a38fefaec5 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' name: 'Dell R740: {#BATTERY_NAME} is not in optimal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R740: {#BATTERY_NAME} is in critical state' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' - name: 'Dell R740: {#BATTERY_NAME} is in warning state' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' tags: - tag: scope value: availability preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 4be96c48d54649f193b9bc561c03c11e name: 'Array controller discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,{#CNTLR_NAME},1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79]' key: array.discovery delay: 1h description: 'Scanning table of Array controllers: IDRAC-MIB-SMIv2::controllerTable' item_prototypes: - uuid: 0890ad92aa0543a2b88ab54d87ab2b8d name: 'Dell R740: {#CNTLR_NAME} Model' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}' key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]' history: 7d trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 The controller's name as represented in Storage Management. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: diskarray - tag: component value: storage - uuid: 28e9ac765bc04849bdbbbda006415f9d name: 'Dell R740: {#CNTLR_NAME} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}' key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 The status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: diskarray - tag: component value: storage trigger_prototypes: - uuid: 1be163a9cbf241deb9075ff06b596eb6 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}' name: 'Dell R740: {#CNTLR_NAME} is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for faults.' dependencies: - name: 'Dell R740: {#CNTLR_NAME} is in unrecoverable state' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL}' tags: - tag: scope value: availability - uuid: 9ba11fff789445e69be1a53fa7d0e07e expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL}' name: 'Dell R740: {#CNTLR_NAME} is in unrecoverable state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: DISASTER description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 0c06b18258914e7c8dc9941d0b94f512 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN}' name: 'Dell R740: {#CNTLR_NAME} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' dependencies: - name: 'Dell R740: {#CNTLR_NAME} is in critical state' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}' - name: 'Dell R740: {#CNTLR_NAME} is in unrecoverable state' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL}' tags: - tag: scope value: availability preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 65b22817caf3430795f98dd137660936 name: 'FAN discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.4.700.12.1.5,{#FAN_DESCR},1.3.6.1.4.1.674.10892.5.4.700.12.1.8,{#TYPE},1.3.6.1.4.1.674.10892.5.4.700.12.1.7]' key: fan.discovery delay: 1h filter: conditions: - macro: '{#TYPE}' value: '3' formulaid: A description: 'IDRAC-MIB-SMIv2::coolingDeviceTable' item_prototypes: - uuid: bf2405914d064eafb6ee07f143ed8872 name: 'Dell R740: {#FAN_DESCR} Speed' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}' key: 'dell.server.sensor.fan.speed[coolingDeviceReading.{#SNMPINDEX}]' history: 7d units: rpm description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. tags: - tag: component value: fan - uuid: f7e5afd5c5d04fa482a1a3b6c55c1fe4 name: 'Dell R740: {#FAN_DESCR} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}' key: 'dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the cooling device. valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: fan trigger_prototypes: - uuid: 87d1cd50bf134d6e8bf30e1c97b63880 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"failed"}' name: 'Dell R740: {#FAN_DESCR} is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the fan unit.' tags: - tag: scope value: availability - uuid: 79dc96ea76e44df9b7e0615c97bcd3a7 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalLower"}' name: 'Dell R740: {#FAN_DESCR} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the fan unit.' dependencies: - name: 'Dell R740: {#FAN_DESCR} is in critical state' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"failed"}' tags: - tag: scope value: availability preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: fea760333bef4fbdb8162692fdcc5941 name: 'Physical disk discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,{#DISK_NAME},1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2]' key: physicaldisk.discovery delay: 1h description: 'Scanning table of physical drive entries IDRAC-MIB-SMIv2::physicalDiskTable.' item_prototypes: - uuid: 7074a7eee90a405eafdc9cd88f1f013b name: 'Dell R740: {#DISK_NAME} Media type' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 The media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Drive (SSD). valuemap: name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: 380aaeeabbbd44b59d1afffdfedb0452 name: 'Dell R740: {#DISK_NAME} Model name' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]' history: 7d trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 The model number of the physical disk. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: f76c78de6bde438f8764165f5bae69ed name: 'Dell R740: {#DISK_NAME} Serial number' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]' history: 7d trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 The physical disk's unique identification number from the manufacturer. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 6a99f1c73c9644369947c25d187e812c expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0' name: 'Dell R740: {#DISK_NAME} has been replaced' event_name: 'Dell R740: {#DISK_NAME} has been replaced (new serial number received)' priority: INFO description: '{#DISK_NAME} serial number has changed. Ack to close' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 7c425c1e8ce44e649afeef826c40fcf7 name: 'Dell R740: {#DISK_NAME} Size' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]' history: 7d trends: 0d units: B description: | MIB: IDRAC-MIB-SMIv2 The size of the physical disk in megabytes. preprocessing: - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: cac85f9f55a64fe79f393b5b738e2ec8 name: 'Dell R740: {#DISK_NAME} S.M.A.R.T. Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 Indicates whether the physical disk has received a predictive failure alert. valuemap: name: 'IDRAC-MIB-SMIv2::BooleanType' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: b8d469d16cd7455a94daeeeafb1be82e expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}' name: 'Dell R740: {#DISK_NAME} S.M.A.R.T. failed' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Disk probably requires replacement.' dependencies: - name: 'Dell R740: {#DISK_NAME} failed' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"}' tags: - tag: scope value: availability - uuid: 72672e6e76c24b469dbf296389d7a285 name: 'Dell R740: {#DISK_NAME} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 The status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable valuemap: name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 940630ac993842379dbd17168fcc3f4e expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"}' name: 'Dell R740: {#DISK_NAME} failed' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check physical disk for warnings or errors.' tags: - tag: scope value: availability - uuid: 4b252f24da774362a77be992e0c2e1da expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN:"nonCritical"}' name: 'Dell R740: {#DISK_NAME} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check physical disk for warnings or errors.' dependencies: - name: 'Dell R740: {#DISK_NAME} failed' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R740 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"}' tags: - tag: scope value: availability preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 2d12dc932f974895a55c16d511487fbb name: 'PSU discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.4.600.12.1.5,{#PSU_DESCR},1.3.6.1.4.1.674.10892.5.4.600.12.1.8]' key: psu.discovery delay: 1h description: 'IDRAC-MIB-SMIv2::powerSupplyTable' item_prototypes: - uuid: 7e15cbbcf34d43a2bb55a46705fa44a1 name: 'Dell R740: {#PSU_DESCR}' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}' key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 0600.0012.0001.0005 This attribute defines the status of the power supply. valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: psu trigger_prototypes: - uuid: 6e055e9cf8e34d189b96c121f05cb529 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"nonRecoverable"}' name: 'Dell R740: Power supply {#PSU_DESCR} is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the power supply unit for errors.' tags: - tag: scope value: availability - uuid: 65f2765b5b4e4297ac7cc93499466cc2 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.WARN:"nonCritical"}' name: 'Dell R740: Power supply {#PSU_DESCR} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the power supply unit for errors.' dependencies: - name: 'Dell R740: Power supply {#PSU_DESCR} is in critical state' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"nonRecoverable"}' tags: - tag: scope value: availability preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 69f433d988ac4cb2ad702d972d640896 name: 'Temperature discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.4.700.20.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.674.10892.5.4.700.20.1.8]' key: temp.discovery delay: 1h description: 'Scanning table of Temperature Probe Table IDRAC-MIB-SMIv2::temperatureProbeTable' item_prototypes: - uuid: 1630c8d0f27446a485eb317005dd391f name: 'Dell R740: {#SENSOR_LOCALE} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}' key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]' history: 7d trends: 0d value_type: FLOAT description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the temperature probe. Possible values: other(1), -- probe status is not one of the following: unknown(2), -- probe status is unknown (not known or monitored) ok(3), -- probe is reporting a value within the thresholds nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold criticalUpper(5), -- probe has crossed the upper critical threshold nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold nonCriticalLower(7), -- probe has crossed the lower noncritical threshold criticalLower(8), -- probe has crossed the lower critical threshold nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold failed(10) -- probe is not functional valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: temperature trigger_prototypes: - uuid: a145a8ebf20641b8b2907e1c3e4048d5 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' name: 'Dell R740: Probe {#SENSOR_LOCALE} is in critical status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: fa01e3ea0b5e44739f5ceef4db36cf43 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' name: 'Dell R740: Probe {#SENSOR_LOCALE} is in warning status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R740: Probe {#SENSOR_LOCALE} is in critical status' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' tags: - tag: scope value: availability - uuid: 128395cf2bbf43cf9311bb6dd6573f40 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$SENSOR.TEMP.STATUS.OK}' name: 'Dell R740: Probe {#SENSOR_LOCALE} is not in optimal status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: INFO description: 'Please check the device for faults.' manual_close: 'YES' dependencies: - name: 'Dell R740: Probe {#SENSOR_LOCALE} is in critical status' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' - name: 'Dell R740: Probe {#SENSOR_LOCALE} is in warning status' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R740 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' tags: - tag: scope value: notice - uuid: a87195afc4704b1db8b32bcbf5e6c8a9 name: 'Dell R740: {#SENSOR_LOCALE} Value' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}' key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]' history: 7d value_type: FLOAT units: °C description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. preprocessing: - type: MULTIPLIER parameters: - '0.1' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: temperature preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: b991939e3f2249e08833bb1c61c036ba name: 'Virtual disk discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,{#DISK_NAME},1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2]' key: virtualdisk.discovery delay: 1h description: 'IDRAC-MIB-SMIv2::virtualDiskTable' item_prototypes: - uuid: e55b1c2d1b7d498b9a46e483a16fc6dc name: 'Dell R740: {#DISK_NAME} Layout type' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]' history: 7d description: | MIB: IDRAC-MIB-SMIv2 The virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concatenated RAID 1 10: Concatenated RAID 5 valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskLayout' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 4c7c8f0890cd40a9a86afd50dc1f4cd8 name: 'Dell R740: {#DISK_NAME} Read policy' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.readpolicy[virtualDiskReadPolicy.{#SNMPINDEX}]' delay: 1h history: 2w description: | MIB: IDRAC-MIB-SMIv2 The read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy' tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: ccd5cfbb6e7e419c9169e6ef28c722f8 name: 'Dell R740: {#DISK_NAME} Size' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]' history: 7d trends: 0d units: B description: | MIB: IDRAC-MIB-SMIv2 The size of the virtual disk in megabytes. preprocessing: - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 6fa2291e865246e7ae786ed666f442b8 name: 'Dell R740: {#DISK_NAME} Current state' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]' delay: 3m history: 2w description: | MIB: IDRAC-MIB-SMIv2 The state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration. 3: A Consistency Check (CC) is being performed on the virtual disk. 4: The virtual disk is being initialized. 5: BackGround Initialization (BGI) is being performed on the virtual disk. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState' tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 9b9d9e1d8999455ea8d70834164ecff0 name: 'Dell R740: {#DISK_NAME} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]' history: 7d description: | MIB: IDRAC-MIB-SMIv2 The current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost. 4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskState' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: storage - tag: component value: virtualdisk trigger_prototypes: - uuid: 128bcdb7dc7b445390edd429d01dabf8 expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.CRIT:"failed"}' name: 'Dell R740: {#DISK_NAME} failed' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the virtual disk for warnings or errors.' tags: - tag: scope value: availability - uuid: ce63508ee9c64b80bfaf95568dd7954f expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.WARN:"degraded"}' name: 'Dell R740: {#DISK_NAME} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the virtual disk for warnings or errors.' dependencies: - name: 'Dell R740: {#DISK_NAME} failed' expression: 'last(/DELL PowerEdge R740 SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.CRIT:"failed"}' tags: - tag: scope value: availability - uuid: 8dc6e7a46374409a9f614b854d2ee503 name: 'Dell R740: {#DISK_NAME} Write policy' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.writepolicy[virtualDiskWritePolicy.{#SNMPINDEX}]' delay: 1h history: 2w description: | MIB: IDRAC-MIB-SMIv2 The write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy' tags: - tag: component value: storage - tag: component value: virtualdisk preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: class value: hardware - tag: target value: dell - tag: target value: 'dell poweredge' macros: - macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' value: '3' description: 'The critical status of the disk array cache battery for trigger expression.' - macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' value: '2' description: 'The OK status of the disk array cache battery for trigger expression.' - macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' value: '4' description: 'The warning status of the disk array cache battery for trigger expression.' - macro: '{$DISK.ARRAY.STATUS.CRIT}' value: '5' description: 'The critical status of the disk array for trigger expression.' - macro: '{$DISK.ARRAY.STATUS.FAIL}' value: '6' description: 'The disaster status of the disk array for trigger expression.' - macro: '{$DISK.ARRAY.STATUS.WARN}' value: '4' description: 'The warning status of the disk array for trigger expression.' - macro: '{$DISK.SMART.STATUS.FAIL}' value: '1' description: 'The critical S.M.A.R.T status of the disk for trigger expression.' - macro: '{$DISK.STATUS.FAIL:"critical"}' value: '5' description: 'The critical status of the disk for trigger expression.' - macro: '{$DISK.STATUS.FAIL:"nonRecoverable"}' value: '6' description: 'The critical status of the disk for trigger expression.' - macro: '{$DISK.STATUS.WARN:"nonCritical"}' value: '4' description: 'The warning status of the disk for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"criticalLower"}' value: '8' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"criticalUpper"}' value: '5' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"failed"}' value: '10' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"nonRecoverableLower"}' value: '9' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"nonRecoverableUpper"}' value: '6' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.WARN:"nonCriticalLower"}' value: '7' description: 'The warning value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.WARN:"nonCriticalUpper"}' value: '4' description: 'The warning value of the FAN sensor for trigger expression.' - macro: '{$HEALTH.STATUS.CRIT}' value: '5' description: 'The critical status of the health for trigger expression.' - macro: '{$HEALTH.STATUS.DISASTER}' value: '6' description: 'The disaster status of the health for trigger expression.' - macro: '{$HEALTH.STATUS.WARN}' value: '4' description: 'The warning status of the health for trigger expression.' - macro: '{$PSU.STATUS.CRIT:"critical"}' value: '5' description: 'The critical value of the PSU sensor for trigger expression.' - macro: '{$PSU.STATUS.CRIT:"nonRecoverable"}' value: '6' description: 'The critical value of the PSU sensor for trigger expression.' - macro: '{$PSU.STATUS.WARN:"nonCritical"}' value: '4' description: 'The warning value of the PSU sensor for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.CRIT:"criticalLower"}' value: '8' description: 'The critical status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}' value: '5' description: 'The critical status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' value: '9' description: 'The critical status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}' value: '6' description: 'The critical status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.OK}' value: '3' description: 'The OK status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' value: '7' description: 'The warning status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}' value: '4' description: 'The warning status of the temperature probe for trigger expression.' - macro: '{$SNMP.TIMEOUT}' value: 5m description: 'The time interval for SNMP agent availability trigger expression.' - macro: '{$VDISK.STATUS.CRIT:"failed"}' value: '3' description: 'The critical status of the virtual disk for trigger expression.' - macro: '{$VDISK.STATUS.WARN:"degraded"}' value: '4' description: 'The warning status of the virtual disk for trigger expression.' valuemaps: - uuid: 00de3138244c4b758736da399416b193 name: 'IDRAC-MIB-SMIv2::batteryState' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Ready - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - value: '5' newvalue: Missing - value: '6' newvalue: Charging - value: '7' newvalue: 'Below threshold' - uuid: 30da32599eab4478bc8645382d02a460 name: 'IDRAC-MIB-SMIv2::BooleanType' mappings: - value: '0' newvalue: ok - value: '1' newvalue: failed - uuid: c51def0f0ce640e7ae70f9fe0da7589d name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCritical - value: '5' newvalue: critical - value: '6' newvalue: nonRecoverable - uuid: 349663986938482ca7e4519516a289ea name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCritical - value: '5' newvalue: critical - value: '6' newvalue: nonRecoverable - uuid: 1945a0e1d81f495ab41c9ef848e8fde9 name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: HDD - value: '3' newvalue: SSD - uuid: b3e8adf66be04293ab6b1416705721a6 name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCriticalUpper - value: '5' newvalue: criticalUpper - value: '6' newvalue: nonRecoverableUpper - value: '7' newvalue: nonCriticalLower - value: '8' newvalue: criticalLower - value: '9' newvalue: nonRecoverableLower - value: '10' newvalue: failed - uuid: c6b9cc21da864d47982d1bb4223d5826 name: 'IDRAC-MIB-SMIv2::virtualDiskLayout' mappings: - value: '1' newvalue: Other - value: '2' newvalue: RAID-0 - value: '3' newvalue: RAID-1 - value: '4' newvalue: RAID-5 - value: '5' newvalue: RAID-6 - value: '6' newvalue: RAID-10 - value: '7' newvalue: RAID-50 - value: '8' newvalue: RAID-60 - value: '9' newvalue: 'Concatenated RAID 1' - value: '10' newvalue: 'Concatenated RAID 5' - uuid: 4dbff414bf354da499f98c7391453e47 name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState' mappings: - value: '1' newvalue: 'Not applicable' - value: '2' newvalue: Reconstructing - value: '3' newvalue: Resynching - value: '4' newvalue: Initializing - value: '5' newvalue: 'Background init' - uuid: 5d2e0552eab844728f62b95db3d9dd24 name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy' mappings: - value: '1' newvalue: 'No Read Ahead' - value: '2' newvalue: 'Read Ahead' - value: '3' newvalue: 'Adaptive Read Ahead' - uuid: 2d250d26187e410492725f1022ae7b26 name: 'IDRAC-MIB-SMIv2::virtualDiskState' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Online - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - uuid: 9536e2ee81374408aa40ad069533d6da name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy' mappings: - value: '1' newvalue: 'Write Through' - value: '2' newvalue: 'Write Back' - value: '3' newvalue: 'Force Write Back' - uuid: a5ac79d4c3f14ce59155b61cb0780e57 name: zabbix.host.available mappings: - value: '0' newvalue: 'not available' - value: '1' newvalue: available - value: '2' newvalue: unknown