zabbix_export: version: '6.2' date: '2022-04-06T19:54:19Z' groups: - uuid: e960332b3f6c46a1956486d4f3f99fce name: 'Templates/Server hardware' templates: - uuid: fc834b8da8864678b55557e9a237eac9 template: 'DELL PowerEdge R840 SNMP' name: 'DELL PowerEdge R840 SNMP' description: | Template for DELL PowerEdge R840 servers with iDRAC version 7 and later. MIBs used: IDRAC-MIB-SMIv2 SNMPv2-MIB You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates Template tooling version used: 0.41 groups: - name: 'Templates/Server hardware' items: - uuid: ec1d2a94f64a4efe9970eab633714fc3 name: 'Dell R840: System contact details' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.4.0 key: 'dell.server.contact[sysContact]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. inventory_link: CONTACT preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: cc2480186fee4b81b2c6f2094b772642 name: 'Dell R840: System description' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.1.0 key: 'dell.server.descr[sysDescr]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: 090e35f3537244fb92ddc85d1afc757f name: 'Dell R840: Firmware version' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.1.1.8.0 key: 'dell.server.hw.firmware[racFirmwareVersion]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the firmware version of a remote access card. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: c8e3831037544a87abbd671fe191ab98 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R840 SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R840 SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0' name: 'Dell R840: Firmware has changed' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: INFO description: 'Firmware version has changed. Ack to close.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 6ddb21512bc84a0698b0b52c6b43a670 name: 'Dell R840: Hardware model name' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.1.3.12.0 key: 'dell.server.hw.model[systemModelName]' history: 7d trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the model name of the system. inventory_link: MODEL preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: ecbbcab2c41e4ce7aeafb08229102365 name: 'Dell R840: Hardware serial number' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.1.3.2.0 key: 'dell.server.hw.serialnumber[systemServiceTag]' history: 7d trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the service tag of the system. inventory_link: SERIALNO_A preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system triggers: - uuid: 89f591b666d34aceb71715bfcdda6bff expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R840 SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R840 SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0' name: 'Dell R840: Device has been replaced' event_name: 'Dell R840: Device has been replaced (new serial number received)' priority: INFO description: 'Device serial number has changed. Ack to close' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 500dc5a80d934ae78d4f088d8120b7cc name: 'Dell R840: System location' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.6.0 key: 'dell.server.location[sysLocation]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. inventory_link: LOCATION preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: 4c32406c2d1046d9bb33c3c0844198d7 name: 'Dell R840: System name' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.5.0 key: 'dell.server.name[sysName]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. inventory_link: NAME preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system triggers: - uuid: 7a56b961a858470d82c6fdef62f88f43 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R840 SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R840 SNMP/dell.server.name[sysName]))>0' name: 'Dell R840: System name has changed' event_name: 'Dell R840: System name has changed (new name: {ITEM.VALUE})' priority: INFO description: 'System name has changed. Ack to close.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 761781c399a14befb3eeed3af4039b77 name: 'Dell R840: System object ID' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.2.0 key: 'dell.server.objectid[sysObjectID]' delay: 15m history: 2w trends: '0' value_type: CHAR description: | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining 'what kind of box' is being managed. For example, if vendor 'Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its 'Fred Router'. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: eba6c6f1e7c44ed8a85288ed5ea9f193 name: 'Dell R840: Overall system health status' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.2.1.0 key: 'dell.server.status[globalSystemStatus]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc. valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: health - tag: component value: system triggers: - uuid: db2cabad4c3048d692333ae02ec125fe expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.DISASTER}' name: 'Dell R840: System is in unrecoverable state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: DISASTER description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 65c0bb42f06c463abbf667480cafa40f expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.CRIT}' name: 'Dell R840: System status is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for errors.' tags: - tag: scope value: availability - uuid: 4f8b4ed834504bb5bb6d7c7b9d22700e expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.WARN}' name: 'Dell R840: System status is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for warnings.' dependencies: - name: 'Dell R840: System status is in critical state' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.CRIT}' tags: - tag: scope value: availability - uuid: 5a33de4af38042f3bd27066a519f9996 name: 'Dell R840: Operating system' type: SNMP_AGENT snmp_oid: 1.3.6.1.4.1.674.10892.5.1.3.6.0 key: 'dell.server.sw.os[systemOSName]' delay: 1h history: 2w trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the name of the operating system that the host is running. inventory_link: OS preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: 09a2b4ec3e1943b598347358b442b662 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R840 SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R840 SNMP/dell.server.sw.os[systemOSName]))>0' name: 'Dell R840: Operating system description has changed' priority: INFO description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Ack to close.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: afb22553880b4e85a3cdc910413cc26d name: 'Dell R840: Uptime' type: SNMP_AGENT snmp_oid: 1.3.6.1.2.1.1.3.0 key: 'dell.server.uptime[sysUpTime]' history: 2w trends: 0d units: uptime description: | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: component value: system triggers: - uuid: def9f4b7093f421893d2a65f6416cfe5 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.uptime[sysUpTime])<10m' name: 'Dell R840: has been restarted' event_name: 'Dell R840: {HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING description: 'Uptime is less than 10 minutes' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 1b1f301b2c5f4e5d8fc5e8dcfad63be0 name: 'Dell R840: SNMP traps (fallback)' type: SNMP_TRAP key: snmptrap.fallback history: 2w trends: '0' value_type: LOG description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items' logtimefmt: 'hh:mm:sszyyyy/MM/dd' tags: - tag: component value: network - uuid: a988dcd503a54238815cb57aac22a991 name: 'Dell R840: SNMP agent availability' type: INTERNAL key: 'zabbix[host,snmp,available]' history: 7d valuemap: name: zabbix.host.available preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: health - tag: component value: system triggers: - uuid: c428f917029346679f8763611f5357f0 expression: 'max(/DELL PowerEdge R840 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'Dell R840: No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.' tags: - tag: scope value: availability discovery_rules: - uuid: 2e089f4c080945289f60bdc814ef743b name: 'Array controller cache discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#BATTERY_NUM},1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,{#BATTERY_NAME},1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]' key: array.cache.discovery delay: 1h description: 'Scanning table of Array controllers: IDRAC-MIB-SMIv2::batteryTable' item_prototypes: - uuid: 378e8705311b451a902ffa6fd874d3db name: 'Dell R840: {#BATTERY_NAME} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}' key: 'dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 Current state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and needs to be replaced. 4: The battery temperature is high or charge level is depleting. 5: The battery is missing or not detected. 6: The battery is undergoing the re-charge phase. 7: The battery voltage or charge level is below the threshold. valuemap: name: 'IDRAC-MIB-SMIv2::batteryState' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: battery - tag: component value: diskarray trigger_prototypes: - uuid: 8d4d468bddf14d659ecbf002e37dcafc expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' name: 'Dell R840: {#BATTERY_NAME} is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: afcd3be7b0e343bdbeff78f87ba4f803 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' name: 'Dell R840: {#BATTERY_NAME} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R840: {#BATTERY_NAME} is in critical state' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' tags: - tag: scope value: availability - uuid: ab4482d1d0244a25a5dccf787af77fe0 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' name: 'Dell R840: {#BATTERY_NAME} is not in optimal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R840: {#BATTERY_NAME} is in critical state' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' - name: 'Dell R840: {#BATTERY_NAME} is in warning state' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' tags: - tag: scope value: availability preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: ff1cee07cb854136929b15e7084e5cfe name: 'Array controller discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,{#CNTLR_NAME},1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79]' key: array.discovery delay: 1h description: 'Scanning table of Array controllers: IDRAC-MIB-SMIv2::controllerTable' item_prototypes: - uuid: 30bd55f2bad04fb6892e9be8a2003897 name: 'Dell R840: {#CNTLR_NAME} Model' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}' key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]' history: 7d trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 The controller's name as represented in Storage Management. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: diskarray - tag: component value: storage - uuid: 4ac7263337f74fdbad25f33d2ab1bcb4 name: 'Dell R840: {#CNTLR_NAME} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}' key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 The status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: diskarray - tag: component value: storage trigger_prototypes: - uuid: d3111ea966db4b4993d119eb92c5362b expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}' name: 'Dell R840: {#CNTLR_NAME} is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for faults.' dependencies: - name: 'Dell R840: {#CNTLR_NAME} is in unrecoverable state' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL}' tags: - tag: scope value: availability - uuid: ee5704a6f6fc4e5396a90fc51293fbe6 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL}' name: 'Dell R840: {#CNTLR_NAME} is in unrecoverable state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: DISASTER description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 3bd0b53f65114218b4ce01b4923add3b expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN}' name: 'Dell R840: {#CNTLR_NAME} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' dependencies: - name: 'Dell R840: {#CNTLR_NAME} is in critical state' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}' - name: 'Dell R840: {#CNTLR_NAME} is in unrecoverable state' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL}' tags: - tag: scope value: availability preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: b1f1c88993844c0c8e90a08a7e8aff9b name: 'FAN discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.4.700.12.1.5,{#FAN_DESCR},1.3.6.1.4.1.674.10892.5.4.700.12.1.8,{#TYPE},1.3.6.1.4.1.674.10892.5.4.700.12.1.7]' key: fan.discovery delay: 1h filter: conditions: - macro: '{#TYPE}' value: '3' formulaid: A description: 'IDRAC-MIB-SMIv2::coolingDeviceTable' item_prototypes: - uuid: d2efe32f5c614dca883e433c2f887e1a name: 'Dell R840: {#FAN_DESCR} Speed' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}' key: 'dell.server.sensor.fan.speed[coolingDeviceReading.{#SNMPINDEX}]' history: 7d units: rpm description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device. When the value for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute. tags: - tag: component value: fan - uuid: 5c0e76019b144272b9321f8c4978dfa5 name: 'Dell R840: {#FAN_DESCR} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}' key: 'dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the cooling device. valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: fan trigger_prototypes: - uuid: c35ca42a1b304ef6a279c959970ce205 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"failed"}' name: 'Dell R840: {#FAN_DESCR} is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the fan unit.' tags: - tag: scope value: availability - uuid: c5f641ddfb9547188d937f9a5554931a expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalLower"}' name: 'Dell R840: {#FAN_DESCR} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the fan unit.' dependencies: - name: 'Dell R840: {#FAN_DESCR} is in critical state' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"failed"}' tags: - tag: scope value: availability preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: a444b673d69d4ea7892e6aa28bc2ec9d name: 'Physical disk discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,{#DISK_NAME},1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2]' key: physicaldisk.discovery delay: 1h description: 'Scanning table of physical drive entries IDRAC-MIB-SMIv2::physicalDiskTable.' item_prototypes: - uuid: 7a8f30970e4c43aeac4d9c6a391109d5 name: 'Dell R840: {#DISK_NAME} Media type' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 The media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Drive (SSD). valuemap: name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: 18bca784665445d38bd8feb95cca2bf8 name: 'Dell R840: {#DISK_NAME} Model name' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]' history: 7d trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 The model number of the physical disk. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: d4a5a97a7b134f3aa4e52e7512428efb name: 'Dell R840: {#DISK_NAME} Serial number' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]' history: 7d trends: '0' value_type: CHAR description: | MIB: IDRAC-MIB-SMIv2 The physical disk's unique identification number from the manufacturer. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 98c1eb636c534d20ba14d19efe174d9c expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0' name: 'Dell R840: {#DISK_NAME} has been replaced' event_name: 'Dell R840: {#DISK_NAME} has been replaced (new serial number received)' priority: INFO description: '{#DISK_NAME} serial number has changed. Ack to close' manual_close: 'YES' tags: - tag: scope value: notice - uuid: ce34bb1a25364543aeefc8728fddab26 name: 'Dell R840: {#DISK_NAME} Size' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]' history: 7d trends: 0d units: B description: | MIB: IDRAC-MIB-SMIv2 The size of the physical disk in megabytes. preprocessing: - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: 783739113d0a46e4ab3b77aed900500e name: 'Dell R840: {#DISK_NAME} S.M.A.R.T. Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 Indicates whether the physical disk has received a predictive failure alert. valuemap: name: 'IDRAC-MIB-SMIv2::BooleanType' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: f86285d7142e494998da999d56173dd7 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}' name: 'Dell R840: {#DISK_NAME} S.M.A.R.T. failed' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Disk probably requires replacement.' dependencies: - name: 'Dell R840: {#DISK_NAME} failed' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"}' tags: - tag: scope value: availability - uuid: d55a705be2df4770bdcab2c8691d8db1 name: 'Dell R840: {#DISK_NAME} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}' key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 The status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable valuemap: name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 034509befd5e497ba9c255034171b6c0 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"}' name: 'Dell R840: {#DISK_NAME} failed' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check physical disk for warnings or errors.' tags: - tag: scope value: availability - uuid: be7cfc31a83a4ab9a91150e480c2a1f0 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN:"nonCritical"}' name: 'Dell R840: {#DISK_NAME} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check physical disk for warnings or errors.' dependencies: - name: 'Dell R840: {#DISK_NAME} failed' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"}' tags: - tag: scope value: availability preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 9021b849eb1240d2bf78e9aa5b72793b name: 'PSU discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.4.600.12.1.5,{#PSU_DESCR},1.3.6.1.4.1.674.10892.5.4.600.12.1.8]' key: psu.discovery delay: 1h description: 'IDRAC-MIB-SMIv2::powerSupplyTable' item_prototypes: - uuid: 61749b25d08e4912a59f56571a9774d6 name: 'Dell R840: {#PSU_DESCR}' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}' key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]' history: 7d trends: 0d description: | MIB: IDRAC-MIB-SMIv2 0600.0012.0001.0005 This attribute defines the status of the power supply. valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: psu trigger_prototypes: - uuid: 2228b8364d12446181b79a7d5efdc598 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"nonRecoverable"}' name: 'Dell R840: Power supply {#PSU_DESCR} is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the power supply unit for errors.' tags: - tag: scope value: availability - uuid: c661b2832e1d4c0392e24bbb2c8eaca5 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.WARN:"nonCritical"}' name: 'Dell R840: Power supply {#PSU_DESCR} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the power supply unit for errors.' dependencies: - name: 'Dell R840: Power supply {#PSU_DESCR} is in critical state' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"nonRecoverable"}' tags: - tag: scope value: availability preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: eea494f12aea4e39ae4337c8119af079 name: 'Temperature discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.4.700.20.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.674.10892.5.4.700.20.1.8]' key: temp.discovery delay: 1h description: 'Scanning table of Temperature Probe Table IDRAC-MIB-SMIv2::temperatureProbeTable' item_prototypes: - uuid: 16831b8b067544b180f2fde23894ee51 name: 'Dell R840: {#SENSOR_LOCALE} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}' key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]' history: 7d trends: 0d value_type: FLOAT description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the temperature probe. Possible values: other(1), -- probe status is not one of the following: unknown(2), -- probe status is unknown (not known or monitored) ok(3), -- probe is reporting a value within the thresholds nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold criticalUpper(5), -- probe has crossed the upper critical threshold nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold nonCriticalLower(7), -- probe has crossed the lower noncritical threshold criticalLower(8), -- probe has crossed the lower critical threshold nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold failed(10) -- probe is not functional valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: temperature trigger_prototypes: - uuid: 5b552c02873e4ae39b378362c083fb8b expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' name: 'Dell R840: Probe {#SENSOR_LOCALE} is in critical status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 34638bcb7b3940e7ad69c7cf2f2c330d expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' name: 'Dell R840: Probe {#SENSOR_LOCALE} is in warning status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R840: Probe {#SENSOR_LOCALE} is in critical status' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' tags: - tag: scope value: availability - uuid: 0f7c75277fb64927943339a8b32d7dfb expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$SENSOR.TEMP.STATUS.OK}' name: 'Dell R840: Probe {#SENSOR_LOCALE} is not in optimal status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: INFO description: 'Please check the device for faults.' manual_close: 'YES' dependencies: - name: 'Dell R840: Probe {#SENSOR_LOCALE} is in critical status' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' - name: 'Dell R840: Probe {#SENSOR_LOCALE} is in warning status' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' tags: - tag: scope value: notice - uuid: bc5758288a7f4cdc802f01d6a0041c95 name: 'Dell R840: {#SENSOR_LOCALE} Value' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}' key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]' history: 7d value_type: FLOAT units: °C description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. preprocessing: - type: MULTIPLIER parameters: - '0.1' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: temperature preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 7db9cdc32ed841b5aac7cdc456be8732 name: 'Virtual disk discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,{#DISK_NAME},1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2]' key: virtualdisk.discovery delay: 1h description: 'IDRAC-MIB-SMIv2::virtualDiskTable' item_prototypes: - uuid: 1d6d0817bf914664be165d9478aa0514 name: 'Dell R840: {#DISK_NAME} Layout type' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]' history: 7d description: | MIB: IDRAC-MIB-SMIv2 The virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concatenated RAID 1 10: Concatenated RAID 5 valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskLayout' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: a26ef2f0b1364a4fb3372f9038b377b7 name: 'Dell R840: {#DISK_NAME} Read policy' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.readpolicy[virtualDiskReadPolicy.{#SNMPINDEX}]' delay: 1h history: 2w description: | MIB: IDRAC-MIB-SMIv2 The read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy' tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 23fddb41194f4497b140f210d3a91450 name: 'Dell R840: {#DISK_NAME} Size' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]' history: 7d trends: 0d units: B description: | MIB: IDRAC-MIB-SMIv2 The size of the virtual disk in megabytes. preprocessing: - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 602c22ba4876450aacde99e08205c5d8 name: 'Dell R840: {#DISK_NAME} Current state' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]' delay: 3m history: 2w description: | MIB: IDRAC-MIB-SMIv2 The state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration. 3: A Consistency Check (CC) is being performed on the virtual disk. 4: The virtual disk is being initialized. 5: BackGround Initialization (BGI) is being performed on the virtual disk. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState' tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 14c253cbc8174d1584bcb30f13c63050 name: 'Dell R840: {#DISK_NAME} Status' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]' history: 7d description: | MIB: IDRAC-MIB-SMIv2 The current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost. 4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskState' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: storage - tag: component value: virtualdisk trigger_prototypes: - uuid: 96f488d383e9445b9646ff18f69eea9a expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.CRIT:"failed"}' name: 'Dell R840: {#DISK_NAME} failed' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the virtual disk for warnings or errors.' tags: - tag: scope value: availability - uuid: 37777a2664ea46399847736412b937c5 expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.WARN:"degraded"}' name: 'Dell R840: {#DISK_NAME} is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the virtual disk for warnings or errors.' dependencies: - name: 'Dell R840: {#DISK_NAME} failed' expression: 'last(/DELL PowerEdge R840 SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.CRIT:"failed"}' tags: - tag: scope value: availability - uuid: 1e6bb77e2d114879b86c0afa07161079 name: 'Dell R840: {#DISK_NAME} Write policy' type: SNMP_AGENT snmp_oid: '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}' key: 'dell.server.hw.virtualdisk.writepolicy[virtualDiskWritePolicy.{#SNMPINDEX}]' delay: 1h history: 2w description: | MIB: IDRAC-MIB-SMIv2 The write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy' tags: - tag: component value: storage - tag: component value: virtualdisk preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: class value: hardware - tag: target value: dell - tag: target value: 'dell poweredge' macros: - macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' value: '3' description: 'The critical status of the disk array cache battery for trigger expression.' - macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' value: '2' description: 'The OK status of the disk array cache battery for trigger expression.' - macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' value: '4' description: 'The warning status of the disk array cache battery for trigger expression.' - macro: '{$DISK.ARRAY.STATUS.CRIT}' value: '5' description: 'The critical status of the disk array for trigger expression.' - macro: '{$DISK.ARRAY.STATUS.FAIL}' value: '6' description: 'The disaster status of the disk array for trigger expression.' - macro: '{$DISK.ARRAY.STATUS.WARN}' value: '4' description: 'The warning status of the disk array for trigger expression.' - macro: '{$DISK.SMART.STATUS.FAIL}' value: '1' description: 'The critical S.M.A.R.T status of the disk for trigger expression.' - macro: '{$DISK.STATUS.FAIL:"critical"}' value: '5' description: 'The critical status of the disk for trigger expression.' - macro: '{$DISK.STATUS.FAIL:"nonRecoverable"}' value: '6' description: 'The critical status of the disk for trigger expression.' - macro: '{$DISK.STATUS.WARN:"nonCritical"}' value: '4' description: 'The warning status of the disk for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"criticalLower"}' value: '8' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"criticalUpper"}' value: '5' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"failed"}' value: '10' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"nonRecoverableLower"}' value: '9' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.CRIT:"nonRecoverableUpper"}' value: '6' description: 'The critical value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.WARN:"nonCriticalLower"}' value: '7' description: 'The warning value of the FAN sensor for trigger expression.' - macro: '{$FAN.STATUS.WARN:"nonCriticalUpper"}' value: '4' description: 'The warning value of the FAN sensor for trigger expression.' - macro: '{$HEALTH.STATUS.CRIT}' value: '5' description: 'The critical status of the health for trigger expression.' - macro: '{$HEALTH.STATUS.DISASTER}' value: '6' description: 'The disaster status of the health for trigger expression.' - macro: '{$HEALTH.STATUS.WARN}' value: '4' description: 'The warning status of the health for trigger expression.' - macro: '{$PSU.STATUS.CRIT:"critical"}' value: '5' description: 'The critical value of the PSU sensor for trigger expression.' - macro: '{$PSU.STATUS.CRIT:"nonRecoverable"}' value: '6' description: 'The critical value of the PSU sensor for trigger expression.' - macro: '{$PSU.STATUS.WARN:"nonCritical"}' value: '4' description: 'The warning value of the PSU sensor for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.CRIT:"criticalLower"}' value: '8' description: 'The critical status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}' value: '5' description: 'The critical status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' value: '9' description: 'The critical status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}' value: '6' description: 'The critical status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.OK}' value: '3' description: 'The OK status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' value: '7' description: 'The warning status of the temperature probe for trigger expression.' - macro: '{$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}' value: '4' description: 'The warning status of the temperature probe for trigger expression.' - macro: '{$SNMP.TIMEOUT}' value: 5m description: 'The time interval for SNMP agent availability trigger expression.' - macro: '{$VDISK.STATUS.CRIT:"failed"}' value: '3' description: 'The critical status of the virtual disk for trigger expression.' - macro: '{$VDISK.STATUS.WARN:"degraded"}' value: '4' description: 'The warning status of the virtual disk for trigger expression.' valuemaps: - uuid: 644e180666f042d79bed40ac4e55c9bd name: 'IDRAC-MIB-SMIv2::batteryState' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Ready - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - value: '5' newvalue: Missing - value: '6' newvalue: Charging - value: '7' newvalue: 'Below threshold' - uuid: 42f304068b834ba48db2eb28cb29d9f3 name: 'IDRAC-MIB-SMIv2::BooleanType' mappings: - value: '0' newvalue: ok - value: '1' newvalue: failed - uuid: ee86b423d3444d57b7fc11fbb4989177 name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCritical - value: '5' newvalue: critical - value: '6' newvalue: nonRecoverable - uuid: f655a6ed92e6430d9dbb7eff874f6307 name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCritical - value: '5' newvalue: critical - value: '6' newvalue: nonRecoverable - uuid: 3b74eb4e2b6144da845dfa5068f2dd08 name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: HDD - value: '3' newvalue: SSD - uuid: e87119147cd74d299861d14e1bc9c1af name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCriticalUpper - value: '5' newvalue: criticalUpper - value: '6' newvalue: nonRecoverableUpper - value: '7' newvalue: nonCriticalLower - value: '8' newvalue: criticalLower - value: '9' newvalue: nonRecoverableLower - value: '10' newvalue: failed - uuid: b513b8f45d6a4d17925669c35a68d7b6 name: 'IDRAC-MIB-SMIv2::virtualDiskLayout' mappings: - value: '1' newvalue: Other - value: '2' newvalue: RAID-0 - value: '3' newvalue: RAID-1 - value: '4' newvalue: RAID-5 - value: '5' newvalue: RAID-6 - value: '6' newvalue: RAID-10 - value: '7' newvalue: RAID-50 - value: '8' newvalue: RAID-60 - value: '9' newvalue: 'Concatenated RAID 1' - value: '10' newvalue: 'Concatenated RAID 5' - uuid: 18152f06a04b4dfd84ade32d0a316769 name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState' mappings: - value: '1' newvalue: 'Not applicable' - value: '2' newvalue: Reconstructing - value: '3' newvalue: Resynching - value: '4' newvalue: Initializing - value: '5' newvalue: 'Background init' - uuid: 09d591b105544625acf40b12b0569c9c name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy' mappings: - value: '1' newvalue: 'No Read Ahead' - value: '2' newvalue: 'Read Ahead' - value: '3' newvalue: 'Adaptive Read Ahead' - uuid: 2cae2d1a9ad74ffe861f09a11f644550 name: 'IDRAC-MIB-SMIv2::virtualDiskState' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Online - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - uuid: 6b19b83ac05e49749f592db773ab6db3 name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy' mappings: - value: '1' newvalue: 'Write Through' - value: '2' newvalue: 'Write Back' - value: '3' newvalue: 'Force Write Back' - uuid: 39239bfc67b84ac9a4854f5d10d72f58 name: zabbix.host.available mappings: - value: '0' newvalue: 'not available' - value: '1' newvalue: available - value: '2' newvalue: unknown