Welcome to mirror list, hosted at ThFree Co, Russian Federation.

template_net_brocade_foundry_sw_snmp.yaml « brocade_foundry_sw_snmp « net « templates - github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
blob: a163ab52cfb46aacd887c06d546b5f6c8ae53848 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
zabbix_export:
  version: '5.4'
  date: '2021-05-10T19:41:19Z'
  groups:
    -
      uuid: 57b7ae836ca64446ba2c296389c009b7
      name: Templates/Modules
    -
      uuid: 36bff6c29af64692839d077febfc7079
      name: 'Templates/Network devices'
  templates:
    -
      uuid: 6ecfb7083ddf45f183ab4be50cfba37a
      template: 'Brocade_Foundry Nonstackable SNMP'
      name: 'Brocade_Foundry Nonstackable SNMP'
      description: |
        Template Net Brocade_Foundry Nonstackable
        
        MIBs used:
        FOUNDRY-SN-AGENT-MIB
        
        Template tooling version used: 0.38
      templates:
        -
          name: 'Brocade_Foundry Performance SNMP'
        -
          name: 'Generic SNMP'
        -
          name: 'Interfaces SNMP'
      groups:
        -
          name: 'Templates/Network devices'
      items:
        -
          uuid: 4f58884d810a416ea321dd622c876d06
          name: 'Firmware version'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.1991.1.1.2.1.11.0
          key: system.hw.firmware
          delay: 1h
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: FOUNDRY-SN-AGENT-MIB
            The version of the running software in the form'major.minor.maintenance[letters]'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 1d
          tags:
            -
              tag: Application
              value: Inventory
          triggers:
            -
              uuid: 61623e6327da42749561301d6dbf92fc
              expression: '(last(/Brocade_Foundry Nonstackable SNMP/system.hw.firmware,#1)<>last(/Brocade_Foundry Nonstackable SNMP/system.hw.firmware,#2))=1 and length(last(/Brocade_Foundry Nonstackable SNMP/system.hw.firmware))>0'
              name: 'Firmware has changed'
              opdata: 'Current value: {ITEM.LASTVALUE1}'
              priority: INFO
              description: 'Firmware version has changed. Ack to close'
              manual_close: 'YES'
        -
          uuid: 7d8b9dc153c4408c99a707a9b4d57647
          name: 'Hardware serial number'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.1991.1.1.1.1.2.0
          key: system.hw.serialnumber
          delay: 1h
          history: 2w
          trends: '0'
          value_type: CHAR
          description: 'MIB: FOUNDRY-SN-AGENT-MIB'
          inventory_link: SERIALNO_A
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 1d
          tags:
            -
              tag: Application
              value: Inventory
          triggers:
            -
              uuid: 987c6aebaad147b4a18df3a04d404ea3
              expression: '(last(/Brocade_Foundry Nonstackable SNMP/system.hw.serialnumber,#1)<>last(/Brocade_Foundry Nonstackable SNMP/system.hw.serialnumber,#2))=1 and length(last(/Brocade_Foundry Nonstackable SNMP/system.hw.serialnumber))>0'
              name: 'Device has been replaced (new serial number received)'
              priority: INFO
              description: 'Device serial number has changed. Ack to close'
              manual_close: 'YES'
      discovery_rules:
        -
          uuid: cb46b61100c8456098a85b1e48644146
          name: 'FAN Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#FAN_INDEX},1.3.6.1.4.1.1991.1.1.1.3.1.1.1]'
          key: fan.discovery
          delay: 1h
          description: 'snChasFanTable: A table of each fan information. Only installed fan appears in a table row.'
          item_prototypes:
            -
              uuid: 9edc2a34faa84e908b33259d495b5da1
              name: 'Fan {#FAN_INDEX}: Fan status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.1991.1.1.1.3.1.1.3.{#SNMPINDEX}'
              key: 'sensor.fan.status[snChasFanOperStatus.{#SNMPINDEX}]'
              delay: 3m
              history: 2w
              trends: 0d
              description: 'MIB: FOUNDRY-SN-AGENT-MIB'
              valuemap:
                name: 'FOUNDRY-SN-AGENT-MIB::snChasFanOperStatus'
              tags:
                -
                  tag: Application
                  value: Fans
              trigger_prototypes:
                -
                  uuid: a568359a825b4e2fa7d0f3883cf88e85
                  expression: 'count(/Brocade_Foundry Nonstackable SNMP/sensor.fan.status[snChasFanOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
                  name: 'Fan {#FAN_INDEX}: Fan is in critical state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
                  description: 'Please check the fan unit'
                -
                  uuid: 5abf8a6bfeec426887ac41a0d80fef9f
                  expression: 'count(/Brocade_Foundry Nonstackable SNMP/sensor.fan.status[snChasFanOperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1'
                  name: 'Fan {#FAN_INDEX}: Fan is not in normal state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: INFO
                  description: 'Please check the fan unit'
                  dependencies:
                    -
                      name: 'Fan {#FAN_INDEX}: Fan is in critical state'
                      expression: 'count(/Brocade_Foundry Nonstackable SNMP/sensor.fan.status[snChasFanOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
        -
          uuid: 9ea01b3ce15248868f1ced0b38bf1245
          name: 'PSU Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#PSU_INDEX},1.3.6.1.4.1.1991.1.1.1.2.1.1.1]'
          key: psu.discovery
          delay: 1h
          description: 'snChasPwrSupplyTable: A table of each power supply information. Only installed power supply appears in a table row.'
          item_prototypes:
            -
              uuid: 47e7c7bb4c27483bb4dd458b5a2d2c1e
              name: 'PSU {#PSU_INDEX}: Power supply status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.1991.1.1.1.2.1.1.3.{#SNMPINDEX}'
              key: 'sensor.psu.status[snChasPwrSupplyOperStatus.{#SNMPINDEX}]'
              delay: 3m
              history: 2w
              trends: 0d
              description: 'MIB: FOUNDRY-SN-AGENT-MIB'
              valuemap:
                name: 'FOUNDRY-SN-AGENT-MIB::snChasPwrSupplyOperStatus'
              tags:
                -
                  tag: Application
                  value: 'Power supply'
              trigger_prototypes:
                -
                  uuid: b2f64b6779ec451c8fc3b5f7cbf61aaa
                  expression: 'count(/Brocade_Foundry Nonstackable SNMP/sensor.psu.status[snChasPwrSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
                  name: 'PSU {#PSU_INDEX}: Power supply is in critical state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
                  description: 'Please check the power supply unit for errors'
                -
                  uuid: e42cd46c58f442129c294f4d4e7e92bc
                  expression: 'count(/Brocade_Foundry Nonstackable SNMP/sensor.psu.status[snChasPwrSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1'
                  name: 'PSU {#PSU_INDEX}: Power supply is not in normal state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: INFO
                  description: 'Please check the power supply unit for errors'
                  dependencies:
                    -
                      name: 'PSU {#PSU_INDEX}: Power supply is in critical state'
                      expression: 'count(/Brocade_Foundry Nonstackable SNMP/sensor.psu.status[snChasPwrSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
        -
          uuid: 5b62e90cfc5549d4b189158499b3d9fb
          name: 'Temperature Discovery Chassis'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1991.1.1.1.1.18]'
          key: temp.chassis.discovery
          delay: 1h
          description: 'Since temperature of the chassis is not available on all Brocade/Foundry hardware, this LLD is here to avoid unsupported items.'
          item_prototypes:
            -
              uuid: 699f30c8feee47cf8bf3da4d10f2c8aa
              name: 'Chassis #{#SNMPINDEX}: Temperature'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.1991.1.1.1.1.18.{#SNMPINDEX}'
              key: 'sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}]'
              delay: 3m
              value_type: FLOAT
              units: °C
              description: |
                MIB: FOUNDRY-SN-AGENT-MIB
                Temperature of the chassis. Each unit is 0.5 degrees Celsius.
                Only management module built with temperature sensor hardware is applicable.
                For those non-applicable management module, it returns no-such-name.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.5'
              tags:
                -
                  tag: Application
                  value: Temperature
              trigger_prototypes:
                -
                  uuid: cfce68bf1cd54a0182fd7f120e6ddb07
                  expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Chassis"}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Chassis"}-3'
                  name: 'Chassis #{#SNMPINDEX}: Temperature is above critical threshold: >{$TEMP_CRIT:"Chassis"}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: HIGH
                  description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
                -
                  uuid: 3d05b6e0662d466191b3322b4b240c28
                  expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Chassis"}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:"Chassis"}-3'
                  name: 'Chassis #{#SNMPINDEX}: Temperature is above warning threshold: >{$TEMP_WARN:"Chassis"}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
                  dependencies:
                    -
                      name: 'Chassis #{#SNMPINDEX}: Temperature is above critical threshold: >{$TEMP_CRIT:"Chassis"}'
                      expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Chassis"}'
                      recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Chassis"}-3'
                -
                  uuid: d88d423ddf224e35805320dd055d21ef
                  expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Chassis"}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'min(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snChasActualTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"Chassis"}+3'
                  name: 'Chassis #{#SNMPINDEX}: Temperature is too low: <{$TEMP_CRIT_LOW:"Chassis"}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
        -
          uuid: 44a84963c9d04fc5a82415602ec8db33
          name: 'Temperature Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#SENSOR_DESCR},1.3.6.1.4.1.1991.1.1.2.13.1.1.3]'
          key: temp.discovery
          delay: 1h
          description: 'snAgentTempTable:Table to list temperatures of the modules in the device. This table is applicable to only those modules with temperature sensors.'
          item_prototypes:
            -
              uuid: c181349497cc4d2dbaf43f51712278df
              name: '{#SENSOR_DESCR}: Temperature'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.1991.1.1.2.13.1.1.4.{#SNMPINDEX}'
              key: 'sensor.temp.value[snAgentTempValue.{#SNMPINDEX}]'
              delay: 3m
              value_type: FLOAT
              units: °C
              description: |
                MIB: FOUNDRY-SN-AGENT-MIB
                Temperature of the sensor represented by this row. Each unit is 0.5 degrees Celsius.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.5'
              tags:
                -
                  tag: Application
                  value: Temperature
              trigger_prototypes:
                -
                  uuid: c4941f5f257544c981d71f3b3836e9da
                  expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3'
                  name: '{#SENSOR_DESCR}: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: HIGH
                  description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
                -
                  uuid: 6c67622c31364d3cafc6187d3b371bb9
                  expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3'
                  name: '{#SENSOR_DESCR}: Temperature is above warning threshold: >{$TEMP_WARN:""}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
                  dependencies:
                    -
                      name: '{#SENSOR_DESCR}: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
                      expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}'
                      recovery_expression: 'max(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3'
                -
                  uuid: 8851b58aff7f492d8f83ec625002fe6e
                  expression: 'avg(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'min(/Brocade_Foundry Nonstackable SNMP/sensor.temp.value[snAgentTempValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3'
                  name: '{#SENSOR_DESCR}: Temperature is too low: <{$TEMP_CRIT_LOW:""}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
      macros:
        -
          macro: '{$FAN_CRIT_STATUS}'
          value: '3'
        -
          macro: '{$FAN_OK_STATUS}'
          value: '2'
        -
          macro: '{$PSU_CRIT_STATUS}'
          value: '3'
        -
          macro: '{$PSU_OK_STATUS}'
          value: '2'
        -
          macro: '{$TEMP_CRIT}'
          value: '75'
        -
          macro: '{$TEMP_CRIT_LOW}'
          value: '5'
        -
          macro: '{$TEMP_WARN}'
          value: '65'
      valuemaps:
        -
          uuid: d457efd8cee74f168bd88f4fb2376142
          name: 'FOUNDRY-SN-AGENT-MIB::snChasFanOperStatus'
          mappings:
            -
              value: '1'
              newvalue: other
            -
              value: '2'
              newvalue: normal
            -
              value: '3'
              newvalue: failure
        -
          uuid: fe1c4f9f35a34b6189110fc95e21b086
          name: 'FOUNDRY-SN-AGENT-MIB::snChasPwrSupplyOperStatus'
          mappings:
            -
              value: '1'
              newvalue: other
            -
              value: '2'
              newvalue: normal
            -
              value: '3'
              newvalue: failure
    -
      uuid: c55052212c774e3fbab00343050b3db5
      template: 'Brocade_Foundry Performance SNMP'
      name: 'Brocade_Foundry Performance SNMP'
      description: |
        Template Module Brocade_Foundry Performance
        
        MIBs used:
        FOUNDRY-SN-AGENT-MIB
        
        Template tooling version used: 0.38
      groups:
        -
          name: Templates/Modules
      items:
        -
          uuid: b2bda926f1864eb893c53ef0c6cad2a2
          name: 'CPU utilization'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.1991.1.1.2.1.52.0
          key: 'system.cpu.util[snAgGblCpuUtil1MinAvg.0]'
          history: 7d
          value_type: FLOAT
          units: '%'
          description: |
            MIB: FOUNDRY-SN-AGENT-MIB
            The statistics collection of 1 minute CPU utilization.
          tags:
            -
              tag: Application
              value: CPU
          triggers:
            -
              uuid: e1f5079bfc584821a071c248ff638cca
              expression: 'min(/Brocade_Foundry Performance SNMP/system.cpu.util[snAgGblCpuUtil1MinAvg.0],5m)>{$CPU.UTIL.CRIT}'
              name: 'High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
              opdata: 'Current utilization: {ITEM.LASTVALUE1}'
              priority: WARNING
              description: 'CPU utilization is too high. The system might be slow to respond.'
        -
          uuid: e357f3d53b9a48a087e140b94b3aff1d
          name: 'Memory utilization'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.1991.1.1.2.1.53.0
          key: 'vm.memory.util[snAgGblDynMemUtil.0]'
          history: 7d
          value_type: FLOAT
          units: '%'
          description: |
            MIB: FOUNDRY-SN-AGENT-MIB
            The system dynamic memory utilization, in unit of percentage.
            Deprecated: Refer to snAgSystemDRAMUtil.
            For NI platforms, refer to snAgentBrdMemoryUtil100thPercent
          tags:
            -
              tag: Application
              value: Memory
          triggers:
            -
              uuid: d89d3c1798ac4bdf86255cedcf38fbef
              expression: 'min(/Brocade_Foundry Performance SNMP/vm.memory.util[snAgGblDynMemUtil.0],5m)>{$MEMORY.UTIL.MAX}'
              name: 'High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
              priority: AVERAGE
              description: 'The system is running out of free memory.'
      macros:
        -
          macro: '{$CPU.UTIL.CRIT}'
          value: '90'
        -
          macro: '{$MEMORY.UTIL.MAX}'
          value: '90'
    -
      uuid: f64ad01567914165a493815e492fb315
      template: 'Brocade_Foundry Stackable SNMP'
      name: 'Brocade_Foundry Stackable SNMP'
      description: |
        Template Brocade_Foundry Stackable
        
        MIBs used:
        FOUNDRY-SN-AGENT-MIB
        FOUNDRY-SN-STACKING-MIB
        
        Known Issues:
        
          Description: Correct fan(returns fan status as 'other(1)' and temperature (returns 0) for the non-master Switches are not available in SNMP
          Version: Version 08.0.40b and above
          Device: ICX 7750 in stack
        
        Template tooling version used: 0.38
      templates:
        -
          name: 'Brocade_Foundry Performance SNMP'
        -
          name: 'Generic SNMP'
        -
          name: 'Interfaces SNMP'
      groups:
        -
          name: 'Templates/Network devices'
      items:
        -
          uuid: 5c17e0d80c354391b339142f2a973886
          name: 'Firmware version'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.1991.1.1.2.1.11.0
          key: system.hw.firmware
          delay: 1h
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: FOUNDRY-SN-AGENT-MIB
            The version of the running software in the form 'major.minor.maintenance[letters]'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 1d
          tags:
            -
              tag: Application
              value: Inventory
          triggers:
            -
              uuid: 1ff89527969140929da6e30e262796da
              expression: '(last(/Brocade_Foundry Stackable SNMP/system.hw.firmware,#1)<>last(/Brocade_Foundry Stackable SNMP/system.hw.firmware,#2))=1 and length(last(/Brocade_Foundry Stackable SNMP/system.hw.firmware))>0'
              name: 'Firmware has changed'
              opdata: 'Current value: {ITEM.LASTVALUE1}'
              priority: INFO
              description: 'Firmware version has changed. Ack to close'
              manual_close: 'YES'
      discovery_rules:
        -
          uuid: 88f67d02cd484dfb841f5f841c3e0bd6
          name: 'Chassis Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1991.1.1.1.4.1.1.1]'
          key: chassis.discovery
          delay: 1h
          description: 'snChasUnitIndex: The index to chassis table.'
          item_prototypes:
            -
              uuid: 2638da6ab127484f8119f8d46d5c996b
              name: 'Unit {#SNMPVALUE}: Hardware serial number'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.1991.1.1.1.4.1.1.2.{#SNMPINDEX}'
              key: 'system.hw.serialnumber[snChasUnitSerNum.{#SNMPINDEX}]'
              delay: 1h
              history: 2w
              trends: '0'
              value_type: CHAR
              description: |
                MIB: FOUNDRY-SN-AGENT-MIB
                The serial number of the chassis for each unit. If the serial number is unknown or unavailable then the value should be a zero length string.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 1d
              tags:
                -
                  tag: Application
                  value: Inventory
              trigger_prototypes:
                -
                  uuid: 05acda91381d489c843cdf95091a88a8
                  expression: '(last(/Brocade_Foundry Stackable SNMP/system.hw.serialnumber[snChasUnitSerNum.{#SNMPINDEX}],#1)<>last(/Brocade_Foundry Stackable SNMP/system.hw.serialnumber[snChasUnitSerNum.{#SNMPINDEX}],#2))=1 and length(last(/Brocade_Foundry Stackable SNMP/system.hw.serialnumber[snChasUnitSerNum.{#SNMPINDEX}]))>0'
                  name: 'Unit {#SNMPVALUE}: Device has been replaced (new serial number received)'
                  priority: INFO
                  description: 'Device serial number has changed. Ack to close'
                  manual_close: 'YES'
        -
          uuid: a192b69e71684d9381ca48b5453a2d8b
          name: 'FAN Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#FAN_UNIT},1.3.6.1.4.1.1991.1.1.1.3.2.1.1,{#FAN_INDEX},1.3.6.1.4.1.1991.1.1.1.3.2.1.2]'
          key: fan.discovery
          delay: 1h
          description: 'snChasFan2Table: A table of each fan information for each unit. Only installed fan appears in a table row.'
          item_prototypes:
            -
              uuid: 5491a504d4f8441eb3be588f2ed56d7c
              name: 'Unit {#FAN_UNIT} Fan {#FAN_INDEX}: Fan status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.1991.1.1.1.3.2.1.4.{#SNMPINDEX}'
              key: 'sensor.fan.status[snChasFan2OperStatus.{#SNMPINDEX}]'
              delay: 3m
              history: 2w
              trends: 0d
              description: 'MIB: FOUNDRY-SN-AGENT-MIB'
              valuemap:
                name: 'FOUNDRY-SN-AGENT-MIB::snChasFanOperStatus'
              tags:
                -
                  tag: Application
                  value: Fans
              trigger_prototypes:
                -
                  uuid: d0dbfddac91d4b869bde6a8193907ef8
                  expression: 'count(/Brocade_Foundry Stackable SNMP/sensor.fan.status[snChasFan2OperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
                  name: 'Unit {#FAN_UNIT} Fan {#FAN_INDEX}: Fan is in critical state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
                  description: 'Please check the fan unit'
                -
                  uuid: e97ade4236064804ba441f408feb13cb
                  expression: 'count(/Brocade_Foundry Stackable SNMP/sensor.fan.status[snChasFan2OperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1'
                  name: 'Unit {#FAN_UNIT} Fan {#FAN_INDEX}: Fan is not in normal state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: INFO
                  description: 'Please check the fan unit'
                  dependencies:
                    -
                      name: 'Unit {#FAN_UNIT} Fan {#FAN_INDEX}: Fan is in critical state'
                      expression: 'count(/Brocade_Foundry Stackable SNMP/sensor.fan.status[snChasFan2OperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
        -
          uuid: 36f00d10099946c9bf3a9e617252bec1
          name: 'PSU Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#PSU_UNIT},1.3.6.1.4.1.1991.1.1.1.2.2.1.1,{#PSU_INDEX},1.3.6.1.4.1.1991.1.1.1.2.2.1.2]'
          key: psu.discovery
          delay: 1h
          description: 'snChasPwrSupply2Table: A table of each power supply information for each unit. Only installed power supply appears in a table row.'
          item_prototypes:
            -
              uuid: d96f92d0de9e48968483b9354b99e509
              name: 'Unit {#PSU_UNIT} PSU {#PSU_INDEX}: Power supply status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.1991.1.1.1.2.2.1.4.{#SNMPINDEX}'
              key: 'sensor.psu.status[snChasPwrSupply2OperStatus.{#SNMPINDEX}]'
              delay: 3m
              history: 2w
              trends: 0d
              description: 'MIB: FOUNDRY-SN-AGENT-MIB'
              valuemap:
                name: 'FOUNDRY-SN-AGENT-MIB::snChasPwrSupplyOperStatus'
              tags:
                -
                  tag: Application
                  value: 'Power supply'
              trigger_prototypes:
                -
                  uuid: 92d83f6fe26d422084a422596ce98593
                  expression: 'count(/Brocade_Foundry Stackable SNMP/sensor.psu.status[snChasPwrSupply2OperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
                  name: 'Unit {#PSU_UNIT} PSU {#PSU_INDEX}: Power supply is in critical state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
                  description: 'Please check the power supply unit for errors'
                -
                  uuid: f89b346c5b0a4bf1b85d29c0aeb38f24
                  expression: 'count(/Brocade_Foundry Stackable SNMP/sensor.psu.status[snChasPwrSupply2OperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1'
                  name: 'Unit {#PSU_UNIT} PSU {#PSU_INDEX}: Power supply is not in normal state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: INFO
                  description: 'Please check the power supply unit for errors'
                  dependencies:
                    -
                      name: 'Unit {#PSU_UNIT} PSU {#PSU_INDEX}: Power supply is in critical state'
                      expression: 'count(/Brocade_Foundry Stackable SNMP/sensor.psu.status[snChasPwrSupply2OperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
        -
          uuid: e78f4dcfd112442f8b053f1eb0a28741
          name: 'Stack Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1991.1.1.3.31.2.1.1.5]'
          key: stack.discovery
          delay: 1h
          description: 'Discovering snStackingConfigUnitTable for Model names'
          item_prototypes:
            -
              uuid: a4fd63461cb24e4e81e4cbba9f086595
              name: 'Unit {#SNMPINDEX}: Hardware model name'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.1991.1.1.3.31.2.1.1.5.{#SNMPINDEX}'
              key: 'system.hw.model[snStackingConfigUnitType.{#SNMPINDEX}]'
              delay: 1h
              history: 2w
              trends: '0'
              value_type: CHAR
              description: |
                MIB: FOUNDRY-SN-STACKING-MIB
                A description of the configured/active system type for each unit.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 1d
              tags:
                -
                  tag: Application
                  value: Inventory
        -
          uuid: c700d182f3e041d3b31076984100a402
          name: 'Temperature Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#SENSOR_DESCR},1.3.6.1.4.1.1991.1.1.2.13.3.1.4]'
          key: temp.discovery
          delay: 1h
          description: 'snAgentTemp2Table:Table to list temperatures of the modules in the device for each unit. This table is applicable to only those modules with temperature sensors.'
          item_prototypes:
            -
              uuid: a6bc8a2263444fa1a2b07478068d7297
              name: '{#SENSOR_DESCR}: Temperature'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.1991.1.1.2.13.3.1.5.{#SNMPINDEX}'
              key: 'sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}]'
              delay: 3m
              value_type: FLOAT
              units: °C
              description: |
                MIB: FOUNDRY-SN-AGENT-MIB
                Temperature of the sensor represented by this row. Each unit is 0.5 degrees Celsius.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.5'
              tags:
                -
                  tag: Application
                  value: Temperature
              trigger_prototypes:
                -
                  uuid: 4e9d6b6877fa413e8153bb0bdedbeb4e
                  expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3'
                  name: '{#SENSOR_DESCR}: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: HIGH
                  description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
                -
                  uuid: d98959bd9690414d8da22d00398c1eba
                  expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3'
                  name: '{#SENSOR_DESCR}: Temperature is above warning threshold: >{$TEMP_WARN:""}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
                  dependencies:
                    -
                      name: '{#SENSOR_DESCR}: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
                      expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}'
                      recovery_expression: 'max(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3'
                -
                  uuid: f792c2ff0e01410687b91af19cf1ff6e
                  expression: 'avg(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'min(/Brocade_Foundry Stackable SNMP/sensor.temp.value[snAgentTemp2Value.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3'
                  name: '{#SENSOR_DESCR}: Temperature is too low: <{$TEMP_CRIT_LOW:""}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
      macros:
        -
          macro: '{$FAN_CRIT_STATUS}'
          value: '3'
        -
          macro: '{$FAN_OK_STATUS}'
          value: '2'
        -
          macro: '{$PSU_CRIT_STATUS}'
          value: '3'
        -
          macro: '{$PSU_OK_STATUS}'
          value: '2'
        -
          macro: '{$TEMP_CRIT}'
          value: '75'
        -
          macro: '{$TEMP_CRIT_LOW}'
          value: '5'
        -
          macro: '{$TEMP_WARN}'
          value: '65'
      valuemaps:
        -
          uuid: 41fadae69fa64af4a21c853fc00f23c0
          name: 'FOUNDRY-SN-AGENT-MIB::snChasFanOperStatus'
          mappings:
            -
              value: '1'
              newvalue: other
            -
              value: '2'
              newvalue: normal
            -
              value: '3'
              newvalue: failure
        -
          uuid: 7b767e61825544bb857347f303a1f077
          name: 'FOUNDRY-SN-AGENT-MIB::snChasPwrSupplyOperStatus'
          mappings:
            -
              value: '1'
              newvalue: other
            -
              value: '2'
              newvalue: normal
            -
              value: '3'
              newvalue: failure
  graphs:
    -
      uuid: ed536efa5baa4d5ca8ee1af4fc813e72
      name: 'CPU utilization'
      ymin_type_1: FIXED
      ymax_type_1: FIXED
      graph_items:
        -
          drawtype: GRADIENT_LINE
          color: 1A7C11
          item:
            host: 'Brocade_Foundry Performance SNMP'
            key: 'system.cpu.util[snAgGblCpuUtil1MinAvg.0]'
    -
      uuid: 8e5d8b8e81d2473c99df3d7ad5c147c3
      name: 'Memory utilization'
      ymin_type_1: FIXED
      ymax_type_1: FIXED
      graph_items:
        -
          drawtype: GRADIENT_LINE
          color: 1A7C11
          item:
            host: 'Brocade_Foundry Performance SNMP'
            key: 'vm.memory.util[snAgGblDynMemUtil.0]'