1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
|
zabbix_export:
version: '5.4'
date: '2021-05-09T00:00:00Z'
groups:
-
name: 'Templates/Network devices'
templates:
-
template: 'D-Link DES 7200 SNMP'
name: 'D-Link DES 7200 SNMP'
description: |
Template D-Link DES 7200
MIBs used:
MY-PROCESS-MIB
SNMPv2-MIB
MY-MEMORY-MIB
ENTITY-MIB
MY-SYSTEM-MIB
Template tooling version used: 0.38
templates:
-
name: 'Generic SNMP'
-
name: 'Interfaces SNMP'
groups:
-
name: 'Templates/Network devices'
items:
-
name: 'CPU utilization'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.171.10.97.2.36.1.1.3.0
key: 'system.cpu.util[myCPUUtilization5Min.0]'
history: 7d
value_type: FLOAT
units: '%'
description: |
MIB: MY-PROCESS-MIB
CPU utilization in %
tags:
-
tag: Application
value: CPU
triggers:
-
expression: 'min(/D-Link DES 7200 SNMP/system.cpu.util[myCPUUtilization5Min.0],5m)>{$CPU.UTIL.CRIT}'
name: 'High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
opdata: 'Current utilization: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'CPU utilization is too high. The system might be slow to respond.'
-
name: 'Firmware version'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.9.1
key: system.hw.firmware
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: 'MIB: ENTITY-MIB'
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
triggers:
-
expression: '(last(/D-Link DES 7200 SNMP/system.hw.firmware,#1)<>last(/D-Link DES 7200 SNMP/system.hw.firmware,#2))=1 and length(last(/D-Link DES 7200 SNMP/system.hw.firmware))>0'
name: 'Firmware has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Firmware version has changed. Ack to close'
manual_close: 'YES'
-
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.2.1.1.1.0
key: system.hw.model
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should
include the full name and version identification of the system's hardware type, software operating-system, and
networking software.
inventory_link: MODEL
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
-
name: 'Hardware version(revision)'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.8.1
key: system.hw.version
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: 'MIB: ENTITY-MIB'
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
-
name: 'Operating system'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.171.10.97.2.1.1.2.0
key: 'system.sw.os[mySystemSwVersion.0]'
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: 'MIB: MY-SYSTEM-MIB'
inventory_link: OS
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
triggers:
-
expression: '(last(/D-Link DES 7200 SNMP/system.sw.os[mySystemSwVersion.0],#1)<>last(/D-Link DES 7200 SNMP/system.sw.os[mySystemSwVersion.0],#2))=1 and length(last(/D-Link DES 7200 SNMP/system.sw.os[mySystemSwVersion.0]))>0'
name: 'Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.'
manual_close: 'YES'
discovery_rules:
-
name: 'FAN Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.171.10.97.2.1.1.21.1.3]'
key: fan.discovery
delay: 1h
item_prototypes:
-
name: '{#SNMPVALUE}: Fan status'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.171.10.97.2.1.1.21.1.2.{#SNMPINDEX}'
key: 'sensor.fan.status[mySystemFanIsNormal.{#SNMPINDEX}]'
delay: 3m
history: 2w
trends: 0d
description: 'MIB: MY-SYSTEM-MIB'
valuemap:
name: 'MY-SYSTEM-MIB::mySystemFanIsNormal'
tags:
-
tag: Application
value: Fans
trigger_prototypes:
-
expression: 'count(/D-Link DES 7200 SNMP/sensor.fan.status[mySystemFanIsNormal.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
name: '{#SNMPVALUE}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit'
-
name: 'Memory Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.171.10.97.2.35.1.1.1.2]'
key: memory.discovery
delay: 1h
item_prototypes:
-
name: '{#SNMPINDEX}: Memory utilization'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.171.10.97.2.35.1.1.1.3.{#SNMPINDEX}'
key: 'vm.memory.util[myMemoryPoolCurrentUtilization.{#SNMPINDEX}]'
history: 7d
value_type: FLOAT
units: '%'
description: |
MIB: MY-MEMORY-MIB
This is the memory pool utilization currently.
tags:
-
tag: Application
value: Memory
trigger_prototypes:
-
expression: 'min(/D-Link DES 7200 SNMP/vm.memory.util[myMemoryPoolCurrentUtilization.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
name: '{#SNMPINDEX}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
priority: AVERAGE
description: 'The system is running out of free memory.'
graph_prototypes:
-
name: '{#SNMPINDEX}: Memory utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'D-Link DES 7200 SNMP'
key: 'vm.memory.util[myMemoryPoolCurrentUtilization.{#SNMPINDEX}]'
-
name: 'PSU Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.171.10.97.2.1.1.18.1.3]'
key: psu.discovery
delay: 1h
item_prototypes:
-
name: '{#SNMPVALUE}: Power supply status'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.171.10.97.2.1.1.18.1.2.{#SNMPINDEX}'
key: 'sensor.psu.status[mySystemElectricalSourceIsNormal.{#SNMPINDEX}]'
delay: 3m
history: 2w
trends: 0d
description: 'MIB: MY-SYSTEM-MIB'
valuemap:
name: 'MY-SYSTEM-MIB::mySystemFanIsNormal'
tags:
-
tag: Application
value: 'Power supply'
trigger_prototypes:
-
expression: 'count(/D-Link DES 7200 SNMP/sensor.psu.status[mySystemElectricalSourceIsNormal.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
name: '{#SNMPVALUE}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors'
-
name: 'Temperature Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.171.10.97.2.1.1.23.1.2]'
key: temperature.discovery
delay: 1h
item_prototypes:
-
name: '{#SNMPVALUE}: Temperature'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.171.10.97.2.1.1.23.1.3.{#SNMPINDEX}'
key: 'sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}]'
delay: 3m
value_type: FLOAT
units: °C
description: |
MIB: MY-SYSTEM-MIB
Return the current temperature of the FastSwitch.The temperature display is not supported for the current temperature returns to 0.
tags:
-
tag: Application
value: Temperature
trigger_prototypes:
-
expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3'
name: '{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
-
expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3'
name: '{#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:""}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
-
name: '{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}'
recovery_expression: 'max(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3'
-
expression: 'avg(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'min(/D-Link DES 7200 SNMP/sensor.temp.value[mySystemTemperatureCurrent.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3'
name: '{#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:""}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
macros:
-
macro: '{$CPU.UTIL.CRIT}'
value: '90'
-
macro: '{$FAN_CRIT_STATUS}'
value: '5'
-
macro: '{$MEMORY.UTIL.MAX}'
value: '90'
-
macro: '{$PSU_CRIT_STATUS}'
value: '5'
-
macro: '{$TEMP_CRIT}'
value: '75'
-
macro: '{$TEMP_CRIT_LOW}'
value: '5'
-
macro: '{$TEMP_WARN}'
value: '65'
valuemaps:
-
name: 'MY-SYSTEM-MIB::mySystemFanIsNormal'
mappings:
-
value: '1'
newvalue: noexist
-
value: '2'
newvalue: existnopower
-
value: '3'
newvalue: existreadypower
-
value: '4'
newvalue: normal
-
value: '5'
newvalue: powerbutabnormal
-
value: '6'
newvalue: unknown
graphs:
-
name: 'CPU utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'D-Link DES 7200 SNMP'
key: 'system.cpu.util[myCPUUtilization5Min.0]'
|