blob: e9f2f8b960997aa0ddb5763f72fc406b18e805c8 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
|
zabbix_export:
version: '5.2'
date: '2020-10-23T09:05:07Z'
groups:
-
name: 'Templates/Network devices'
templates:
-
template: 'Extreme EXOS SNMP'
name: 'Extreme EXOS SNMP'
description: |
Template Extreme EXOS
MIBs used:
EXTREME-SOFTWARE-MONITOR-MIB
EXTREME-SYSTEM-MIB
ENTITY-MIB
Template tooling version used: 0.38
templates:
-
name: 'EtherLike-MIB SNMP'
-
name: 'Generic SNMP'
-
name: 'Interfaces SNMP'
groups:
-
name: 'Templates/Network devices'
applications:
-
name: CPU
-
name: Fans
-
name: Inventory
-
name: Memory
-
name: 'Power supply'
-
name: Temperature
items:
-
name: 'Device: Temperature status'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.1916.1.1.1.7.0
key: 'sensor.temp.status[extremeOverTemperatureAlarm.0]'
delay: 3m
history: 2w
trends: 0d
description: |
MIB: EXTREME-SYSTEM-MIB
Temperature status of testpoint: Device
applications:
-
name: Temperature
valuemap:
name: 'EXTREME-SYSTEM-MIB::extremeOverTemperatureAlarm'
-
name: 'Device: Temperature'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.1916.1.1.1.8.0
key: 'sensor.temp.value[extremeCurrentTemperature.0]'
delay: 3m
value_type: FLOAT
units: °C
description: |
MIB: EXTREME-SYSTEM-MIB
Temperature readings of testpoint: Device
Reference: https://gtacknowledge.extremenetworks.com/articles/Q_A/Does-EXOS-support-temperature-polling-via-SNMP-on-all-nodes-in-a-stack
applications:
-
name: Temperature
triggers:
-
expression: '{avg(5m)}>{$TEMP_WARN:""}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: '{max(5m)}<{$TEMP_WARN:""}-3'
name: 'Device: Temperature is above warning threshold: >{$TEMP_WARN:""}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
-
name: 'Device: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
expression: |
{Extreme EXOS SNMP:sensor.temp.value[extremeCurrentTemperature.0].avg(5m)}>{$TEMP_CRIT:""}
or
{Extreme EXOS SNMP:sensor.temp.status[extremeOverTemperatureAlarm.0].last()}={$TEMP_CRIT_STATUS}
recovery_expression: '{Extreme EXOS SNMP:sensor.temp.value[extremeCurrentTemperature.0].max(5m)}<{$TEMP_CRIT:""}-3'
-
expression: '{avg(5m)}<{$TEMP_CRIT_LOW:""}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: '{min(5m)}>{$TEMP_CRIT_LOW:""}+3'
name: 'Device: Temperature is too low: <{$TEMP_CRIT_LOW:""}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
-
name: 'CPU utilization'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.1916.1.32.1.2.0
key: 'system.cpu.util[extremeCpuMonitorTotalUtilization.0]'
history: 7d
value_type: FLOAT
units: '%'
description: |
MIB: EXTREME-SOFTWARE-MONITOR-MIB
Total CPU utlization (percentage) as of last sampling.
applications:
-
name: CPU
triggers:
-
expression: '{min(5m)}>{$CPU.UTIL.CRIT}'
name: 'High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
opdata: 'Current utilization: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'CPU utilization is too high. The system might be slow to respond.'
-
name: 'Firmware version'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.9.1
key: system.hw.firmware
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: 'MIB: ENTITY-MIB'
applications:
-
name: Inventory
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
triggers:
-
expression: '{diff()}=1 and {strlen()}>0'
name: 'Firmware has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Firmware version has changed. Ack to close'
manual_close: 'YES'
-
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.2.1
key: system.hw.model
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: 'MIB: ENTITY-MIB'
inventory_link: MODEL
applications:
-
name: Inventory
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
-
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.11.1
key: system.hw.serialnumber
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: 'MIB: ENTITY-MIB'
inventory_link: SERIALNO_A
applications:
-
name: Inventory
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
triggers:
-
expression: '{diff()}=1 and {strlen()}>0'
name: 'Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Ack to close'
manual_close: 'YES'
-
name: 'Hardware version(revision)'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.9.1
key: system.hw.version
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: 'MIB: ENTITY-MIB'
applications:
-
name: Inventory
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
-
name: 'Operating system'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.1916.1.1.1.13.0
key: 'system.sw.os[extremePrimarySoftwareRev.0]'
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: |
MIB: EXTREME-SYSTEM-MIB
The software revision of the primary image stored in this device.
This string will have a zero length if the revision is unknown, invalid or not present.
This will also be reported in RMON2 probeSoftwareRev if this is the software image currently running in the device.
inventory_link: OS
applications:
-
name: Inventory
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
triggers:
-
expression: '{diff()}=1 and {strlen()}>0'
name: 'Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.'
manual_close: 'YES'
discovery_rules:
-
name: 'FAN Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1916.1.1.1.9.1.1]'
key: fan.discovery
delay: 1h
item_prototypes:
-
name: 'Fan {#SNMPVALUE}: Fan speed'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.1916.1.1.1.9.1.4.{#SNMPINDEX}'
key: 'sensor.fan.speed[extremeFanSpeed.{#SNMPINDEX}]'
units: rpm
description: |
MIB: EXTREME-SYSTEM-MIB
The speed (RPM) of a cooling fan in the fantray {#SNMPVALUE}
applications:
-
name: Fans
-
name: 'Fan {#SNMPVALUE}: Fan status'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.1916.1.1.1.9.1.2.{#SNMPINDEX}'
key: 'sensor.fan.status[extremeFanOperational.{#SNMPINDEX}]'
delay: 3m
history: 2w
trends: 0d
description: |
MIB: EXTREME-SYSTEM-MIB
Operational status of a cooling fan.
applications:
-
name: Fans
valuemap:
name: 'EXTREME-SYSTEM-MIB::extremeFanOperational'
trigger_prototypes:
-
expression: '{count(#1,{$FAN_CRIT_STATUS},eq)}=1'
name: 'Fan {#SNMPVALUE}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit'
-
name: 'Memory Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1916.1.32.2.2.1.1]'
key: memory.discovery
delay: 1h
item_prototypes:
-
name: '#{#SNMPVALUE}: Available memory'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.1916.1.32.2.2.1.3.{#SNMPINDEX}'
key: 'vm.memory.available[extremeMemoryMonitorSystemFree.{#SNMPINDEX}]'
history: 7d
units: B
description: |
MIB: EXTREME-SOFTWARE-MONITOR-MIB
Total amount of free memory in Kbytes in the system.
applications:
-
name: Memory
preprocessing:
-
type: MULTIPLIER
parameters:
- '1024'
-
name: '#{#SNMPVALUE}: Total memory'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.1916.1.32.2.2.1.2.{#SNMPINDEX}'
key: 'vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}]'
history: 7d
units: B
description: |
MIB: EXTREME-SOFTWARE-MONITOR-MIB
Total amount of DRAM in Kbytes in the system.
applications:
-
name: Memory
preprocessing:
-
type: MULTIPLIER
parameters:
- '1024'
-
name: '#{#SNMPVALUE}: Memory utilization'
type: CALCULATED
key: 'vm.memory.util[{#SNMPVALUE}]'
history: 7d
value_type: FLOAT
units: '%'
params: '(last("vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}]") - last("vm.memory.available[extremeMemoryMonitorSystemFree.{#SNMPINDEX}]")) / last("vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}]") * 100'
description: 'Memory utilization in %'
applications:
-
name: Memory
trigger_prototypes:
-
expression: '{min(5m)}>{$MEMORY.UTIL.MAX}'
name: '#{#SNMPVALUE}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
priority: AVERAGE
description: 'The system is running out of free memory.'
graph_prototypes:
-
name: '#{#SNMPVALUE}: Memory usage'
ymin_type_1: FIXED
graph_items:
-
drawtype: BOLD_LINE
color: 1A7C11
item:
host: 'Extreme EXOS SNMP'
key: 'vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}]'
-
sortorder: '1'
drawtype: GRADIENT_LINE
color: 2774A4
item:
host: 'Extreme EXOS SNMP'
key: 'vm.memory.available[extremeMemoryMonitorSystemFree.{#SNMPINDEX}]'
-
name: '#{#SNMPVALUE}: Memory utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Extreme EXOS SNMP'
key: 'vm.memory.util[{#SNMPVALUE}]'
-
name: 'PSU Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1916.1.1.1.27.1.1]'
key: psu.discovery
delay: 1h
description: 'Table of status of all power supplies in the system.'
item_prototypes:
-
name: 'PSU {#SNMPVALUE}: Power supply status'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.1916.1.1.1.27.1.2.{#SNMPINDEX}'
key: 'sensor.psu.status[extremePowerSupplyStatus.{#SNMPINDEX}]'
delay: 3m
history: 2w
trends: 0d
description: |
MIB: EXTREME-SYSTEM-MIB
Status of the power supply {#SNMPVALUE}
applications:
-
name: 'Power supply'
valuemap:
name: 'EXTREME-SYSTEM-MIB::extremePowerSupplyStatus'
trigger_prototypes:
-
expression: '{count(#1,{$PSU_CRIT_STATUS},eq)}=1'
name: 'PSU {#SNMPVALUE}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors'
macros:
-
macro: '{$CPU.UTIL.CRIT}'
value: '90'
-
macro: '{$FAN_CRIT_STATUS}'
value: '2'
-
macro: '{$MEMORY.UTIL.MAX}'
value: '90'
-
macro: '{$PSU_CRIT_STATUS}'
value: '3'
-
macro: '{$TEMP_CRIT}'
value: '65'
-
macro: '{$TEMP_CRIT_LOW}'
value: '5'
-
macro: '{$TEMP_CRIT_STATUS}'
value: '1'
-
macro: '{$TEMP_WARN}'
value: '55'
triggers:
-
expression: |
{Extreme EXOS SNMP:sensor.temp.value[extremeCurrentTemperature.0].avg(5m)}>{$TEMP_CRIT:""}
or
{Extreme EXOS SNMP:sensor.temp.status[extremeOverTemperatureAlarm.0].last()}={$TEMP_CRIT_STATUS}
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: '{Extreme EXOS SNMP:sensor.temp.value[extremeCurrentTemperature.0].max(5m)}<{$TEMP_CRIT:""}-3'
name: 'Device: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
graphs:
-
name: 'CPU utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Extreme EXOS SNMP'
key: 'system.cpu.util[extremeCpuMonitorTotalUtilization.0]'
value_maps:
-
name: 'EXTREME-SYSTEM-MIB::extremeFanOperational'
mappings:
-
value: '1'
newvalue: 'true - on'
-
value: '2'
newvalue: 'false - off'
-
name: 'EXTREME-SYSTEM-MIB::extremeOverTemperatureAlarm'
mappings:
-
value: '1'
newvalue: alarm
-
value: '2'
newvalue: normal
-
name: 'EXTREME-SYSTEM-MIB::extremePowerSupplyStatus'
mappings:
-
value: '1'
newvalue: notPresent
-
value: '2'
newvalue: presentOK
-
value: '3'
newvalue: presentNotOK
-
value: '4'
newvalue: presentPowerOff
|