1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
|
zabbix_export:
version: '5.4'
date: '2021-05-10T19:41:25Z'
groups:
-
uuid: 36bff6c29af64692839d077febfc7079
name: 'Templates/Network devices'
templates:
-
uuid: a326034825984bbd8a3a5885f3939bb3
template: 'Juniper SNMP'
name: 'Juniper SNMP'
description: |
Template Net Juniper
MIBs used:
JUNIPER-ALARM-MIB
JUNIPER-MIB
SNMPv2-MIB
Template tooling version used: 0.38
templates:
-
name: 'EtherLike-MIB SNMP'
-
name: 'Generic SNMP'
-
name: 'Interfaces SNMP'
groups:
-
name: 'Templates/Network devices'
items:
-
uuid: 7a472141ebcf4816bffe9bb49f003db6
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.2636.3.1.2.0
key: system.hw.model
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: |
MIB: JUNIPER-MIB
The name, model, or detailed description of the box,indicating which product the box is about, for example 'M40'.
inventory_link: MODEL
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
-
uuid: b836efdbd3ac4becac319030250c1beb
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.2636.3.1.3.0
key: system.hw.serialnumber
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: |
MIB: JUNIPER-MIB
The serial number of this subject, blank if unknown or unavailable.
inventory_link: SERIALNO_A
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
triggers:
-
uuid: f209837c40cd4e3dbe841c439a030676
expression: '(last(/Juniper SNMP/system.hw.serialnumber,#1)<>last(/Juniper SNMP/system.hw.serialnumber,#2))=1 and length(last(/Juniper SNMP/system.hw.serialnumber))>0'
name: 'Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Ack to close'
manual_close: 'YES'
-
uuid: 414a29c595b2439dacb15b4fa0734ab4
name: 'Overall system health status'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.2636.3.4.2.3.1.0
key: 'system.status[jnxRedAlarmState.0]'
delay: 30s
history: 2w
trends: 0d
description: |
MIB: JUNIPER-ALARM-MIB
The red alarm indication on the craft interface panel.
The red alarm is on when there is some system
failure or power supply failure or the system
is experiencing a hardware malfunction or some
threshold is being exceeded.
This red alarm state could be turned off by the
ACO/LT (Alarm Cut Off / Lamp Test) button on the
front panel module.
valuemap:
name: 'JUNIPER-ALARM-MIB::jnxRedAlarmState'
tags:
-
tag: Application
value: Status
triggers:
-
uuid: 2876a88117c64e6aab5d21e95d14049b
expression: 'count(/Juniper SNMP/system.status[jnxRedAlarmState.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1'
name: 'System status is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for errors'
-
uuid: 24cd5862c2de4cbaad0b3bbce7f26a65
name: 'Operating system'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.2.1.1.1.0
key: 'system.sw.os[sysDescr.0]'
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: 'MIB: SNMPv2-MIB'
inventory_link: OS
preprocessing:
-
type: REGEX
parameters:
- 'kernel (JUNOS [0-9a-zA-Z\.\-]+)'
- \1
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
triggers:
-
uuid: 6222b573c18446d4af7a8161d6e07a58
expression: '(last(/Juniper SNMP/system.sw.os[sysDescr.0],#1)<>last(/Juniper SNMP/system.sw.os[sysDescr.0],#2))=1 and length(last(/Juniper SNMP/system.sw.os[sysDescr.0]))>0'
name: 'Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.'
manual_close: 'YES'
discovery_rules:
-
uuid: 3ce46d56008248cf960c6bf689ea7c0b
name: 'CPU and Memory Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.2636.3.1.13.1.5]'
key: jnxOperatingTable.discovery
delay: 1h
filter:
conditions:
-
macro: '{#SNMPVALUE}'
value: 'Routing Engine.*'
formulaid: A
description: |
Scanning JUNIPER-MIB::jnxOperatingTable for CPU and Memory
http://kb.juniper.net/InfoCenter/index?page=content&id=KB17526&actp=search. Filter limits results to Routing Engines
item_prototypes:
-
uuid: 932c89bb249d412fabd3549ddcbf654e
name: '{#SNMPVALUE}: CPU utilization'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.2636.3.1.13.1.8.{#SNMPINDEX}'
key: 'system.cpu.util[jnxOperatingCPU.{#SNMPINDEX}]'
history: 7d
value_type: FLOAT
units: '%'
description: |
MIB: JUNIPER-MIB
The CPU utilization in percentage of this subject. Zero if unavailable or inapplicable.
Reference: http://kb.juniper.net/library/CUSTOMERSERVICE/GLOBAL_JTAC/BK26199/SRX%20SNMP%20Monitoring%20Guide_v1.1.pdf
tags:
-
tag: Application
value: CPU
trigger_prototypes:
-
uuid: 10919751e3804d1189856a181868bccf
expression: 'min(/Juniper SNMP/system.cpu.util[jnxOperatingCPU.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
name: '{#SNMPVALUE}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
opdata: 'Current utilization: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'CPU utilization is too high. The system might be slow to respond.'
-
uuid: f60e29b4392e4a3e882a4175e618890c
name: '{#SNMPVALUE}: Memory utilization'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.2636.3.1.13.1.11.{#SNMPINDEX}'
key: 'vm.memory.util[jnxOperatingBuffer.{#SNMPINDEX}]'
history: 7d
value_type: FLOAT
units: '%'
description: |
MIB: JUNIPER-MIB
The buffer pool utilization in percentage of this subject. Zero if unavailable or inapplicable.
Reference: http://kb.juniper.net/library/CUSTOMERSERVICE/GLOBAL_JTAC/BK26199/SRX%20SNMP%20Monitoring%20Guide_v1.1.pdf
tags:
-
tag: Application
value: Memory
trigger_prototypes:
-
uuid: 0449137ee3d14017ab670d57761293c9
expression: 'min(/Juniper SNMP/vm.memory.util[jnxOperatingBuffer.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
name: '{#SNMPVALUE}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
priority: AVERAGE
description: 'The system is running out of free memory.'
graph_prototypes:
-
uuid: 7cc53c92b6be4fc59d2928e73f6fe8c3
name: '{#SNMPVALUE}: CPU utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Juniper SNMP'
key: 'system.cpu.util[jnxOperatingCPU.{#SNMPINDEX}]'
-
uuid: 646779d729d8417383eb0e1240a69767
name: '{#SNMPVALUE}: Memory utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Juniper SNMP'
key: 'vm.memory.util[jnxOperatingBuffer.{#SNMPINDEX}]'
-
uuid: 6e60561a198d43cf8c0fbe9a8ba1c492
name: 'FAN Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.2636.3.1.13.1.5.4]'
key: jnxOperatingTable.discovery.fans
delay: 1h
description: 'Scanning JUNIPER-MIB::jnxOperatingTable for Fans'
item_prototypes:
-
uuid: be611a0c7aee4d72a0b5c53d199b7469
name: '{#SNMPVALUE}: Fan status'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.2636.3.1.13.1.6.4.{#SNMPINDEX}'
key: 'sensor.fan.status[jnxOperatingState.4.{#SNMPINDEX}]'
delay: 3m
history: 2w
trends: 0d
description: 'MIB: JUNIPER-MIB'
valuemap:
name: 'JUNIPER-ALARM-MIB::jnxOperatingState'
tags:
-
tag: Application
value: Fans
trigger_prototypes:
-
uuid: ec074c1bbbf644bb866869dd187fcfec
expression: 'count(/Juniper SNMP/sensor.fan.status[jnxOperatingState.4.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
name: '{#SNMPVALUE}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit'
-
uuid: aa36adb11a874374a739d96a2f9a0b3d
name: 'PSU Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.2636.3.1.13.1.5.2]'
key: jnxOperatingTable.discovery.psu
delay: 1h
description: 'Scanning JUNIPER-MIB::jnxOperatingTable for Power Supplies'
item_prototypes:
-
uuid: c7101436ab3a4c0696cf74bc3c97c265
name: '{#SNMPVALUE}: Power supply status'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.2636.3.1.13.1.6.2.{#SNMPINDEX}'
key: 'sensor.psu.status[jnxOperatingState.2.{#SNMPINDEX}]'
delay: 3m
history: 2w
trends: 0d
description: |
MIB: JUNIPER-MIB
If they are using DC power supplies there is a known issue on PR 1064039 where the fans do not detect the temperature correctly and fail to cool the power supply causing the shutdown to occur.
This is fixed in Junos 13.3R7 https://forums.juniper.net/t5/Routing/PEM-0-not-OK-MX104/m-p/289644#M14122
valuemap:
name: 'JUNIPER-ALARM-MIB::jnxOperatingState'
tags:
-
tag: Application
value: 'Power supply'
trigger_prototypes:
-
uuid: 5c3b4c8818c94032aff8f9dacd663c3e
expression: 'count(/Juniper SNMP/sensor.psu.status[jnxOperatingState.2.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
name: '{#SNMPVALUE}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors'
-
uuid: e28a9bc06ada4427a7e135aa41c4f76b
name: 'Temperature discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.2636.3.1.13.1.7,{#SENSOR_INFO},1.3.6.1.4.1.2636.3.1.13.1.5]'
key: jnxOperatingTable.discovery.temp
delay: 1h
filter:
conditions:
-
macro: '{#SNMPVALUE}'
value: '[^0]+'
formulaid: A
description: |
Scanning JUNIPER-MIB::jnxOperatingTable for Temperature
http://kb.juniper.net/InfoCenter/index?page=content&id=KB17526&actp=search. Filter limits results to Routing Engines
item_prototypes:
-
uuid: 96f44fbce5de45e6918efd140283453b
name: '{#SENSOR_INFO}: Temperature'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.2636.3.1.13.1.7.{#SNMPINDEX}'
key: 'sensor.temp.value[jnxOperatingTemp.{#SNMPINDEX}]'
delay: 3m
value_type: FLOAT
units: °C
description: |
MIB: JUNIPER-MIB
The temperature in Celsius (degrees C) of {#SENSOR_INFO}
tags:
-
tag: Application
value: Temperature
trigger_prototypes:
-
uuid: 507936bd77a74a9ba500671db9d8ed6d
expression: 'avg(/Juniper SNMP/sensor.temp.value[jnxOperatingTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Juniper SNMP/sensor.temp.value[jnxOperatingTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3'
name: '{#SENSOR_INFO}: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
-
uuid: 49523740c0054bff83f26664ec15ee23
expression: 'avg(/Juniper SNMP/sensor.temp.value[jnxOperatingTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:""}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Juniper SNMP/sensor.temp.value[jnxOperatingTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:""}-3'
name: '{#SENSOR_INFO}: Temperature is above warning threshold: >{$TEMP_WARN:""}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
-
name: '{#SENSOR_INFO}: Temperature is above critical threshold: >{$TEMP_CRIT:""}'
expression: 'avg(/Juniper SNMP/sensor.temp.value[jnxOperatingTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:""}'
recovery_expression: 'max(/Juniper SNMP/sensor.temp.value[jnxOperatingTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:""}-3'
-
uuid: 9688deb24a264f7294d7e97f9d01cc97
expression: 'avg(/Juniper SNMP/sensor.temp.value[jnxOperatingTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:""}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'min(/Juniper SNMP/sensor.temp.value[jnxOperatingTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:""}+3'
name: '{#SENSOR_INFO}: Temperature is too low: <{$TEMP_CRIT_LOW:""}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
macros:
-
macro: '{$CPU.UTIL.CRIT}'
value: '90'
-
macro: '{$FAN_CRIT_STATUS}'
value: '6'
-
macro: '{$HEALTH_CRIT_STATUS}'
value: '3'
-
macro: '{$MEMORY.UTIL.MAX}'
value: '90'
-
macro: '{$PSU_CRIT_STATUS}'
value: '6'
-
macro: '{$TEMP_CRIT}'
value: '60'
-
macro: '{$TEMP_CRIT:"Routing Engine"}'
value: '80'
-
macro: '{$TEMP_CRIT_LOW}'
value: '5'
-
macro: '{$TEMP_WARN}'
value: '50'
-
macro: '{$TEMP_WARN:"Routing Engine"}'
value: '70'
valuemaps:
-
uuid: 64128e7f2adf44988b0ca3edd76cba61
name: 'JUNIPER-ALARM-MIB::jnxOperatingState'
mappings:
-
value: '1'
newvalue: unknown
-
value: '2'
newvalue: running
-
value: '3'
newvalue: ready
-
value: '4'
newvalue: reset
-
value: '5'
newvalue: runningAtFullSpeed
-
value: '6'
newvalue: 'down or off'
-
value: '7'
newvalue: standby
-
uuid: 3aaa451c55cd4e72ab84b65dd8310564
name: 'JUNIPER-ALARM-MIB::jnxRedAlarmState'
mappings:
-
value: '1'
newvalue: other
-
value: '2'
newvalue: 'off'
-
value: '3'
newvalue: 'on - RedAlarm'
|