1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
|
zabbix_export:
version: '5.4'
date: '2021-05-10T19:41:16Z'
groups:
-
uuid: 57b7ae836ca64446ba2c296389c009b7
name: Templates/Modules
templates:
-
uuid: b84324c2a40a496dbbb379bbf5dde8d5
template: 'Morningstar ProStar MPPT SNMP'
name: 'Morningstar ProStar MPPT SNMP'
description: |
MIBs used:
PROSTAR-MPPT
Template tooling version used: 0.38
groups:
-
name: Templates/Modules
items:
-
uuid: a517a7aafbab426eb6ced8d5f57c1fa4
name: 'Array: Sweep Pmax'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.64.0
key: 'array.sweep_pmax[arrayMaxPowerSweep.0]'
history: 7d
value_type: FLOAT
units: W
description: |
MIB: PROSTAR-MPPT
Array Max. Power (sweep)
Description:Array Max. Power (last sweep)
Scaling Factor:1.0
Units:W
Range:[0.0, 500]
Modbus address:0x003E
tags:
-
tag: Application
value: Array
-
uuid: 7714c76013e341f8b6753cc5a50a960f
name: 'Array: Sweep Vmp'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.63.0
key: 'array.sweep_vmp[arrayVmp.0]'
history: 7d
value_type: FLOAT
units: V
description: |
MIB: PROSTAR-MPPT
Array Vmp
Description:Array Max. Power Point Voltage
Scaling Factor:1.0
Units:V
Range:[0.0, 5000.0]
Modbus address:0x003D
tags:
-
tag: Application
value: Array
-
uuid: 379ab969ad784968a1090ff98f5801ff
name: 'Array: Sweep Voc'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.65.0
key: 'array.sweep_voc[arrayVoc.0]'
history: 7d
value_type: FLOAT
units: V
description: |
MIB: PROSTAR-MPPT
Array Voc
Description:Array Open Circuit Voltage
Scaling Factor:1.0
Units:V
Range:[0.0, 80.0]
Modbus address:0x003F
tags:
-
tag: Application
value: Array
-
uuid: 41a1118e1be3417daa79faace733d861
name: 'Array: Voltage'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.31.0
key: 'array.voltage[arrayVoltage.0]'
history: 7d
value_type: FLOAT
units: V
description: |
MIB: PROSTAR-MPPT
Array Voltage
Description:Array Voltage
Scaling Factor:1.0
Units:V
Range:[0, 80]
Modbus address:0x0013
tags:
-
tag: Application
value: Array
-
uuid: fe5c3b724e894573acdaf522a2213adb
name: 'Battery: Battery Voltage discovery'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.30.0
key: 'battery.voltage.discovery[batteryTerminalVoltage.0]'
delay: 15m
history: '0'
value_type: FLOAT
units: V
description: 'MIB: PROSTAR-MPPT'
tags:
-
tag: Application
value: 'Zabbix raw items'
-
uuid: ed1d54fce0904b7c9d0895a094f55108
name: 'Battery: Charge Current'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.33.0
key: 'charge.current[chargeCurrent.0]'
history: 7d
value_type: FLOAT
units: A
description: |
MIB: PROSTAR-MPPT
Charge Current
Description:Charge Current
Scaling Factor:1.0
Units:A
Range:[0, 40]
Modbus address:0x0010
tags:
-
tag: Application
value: Battery
-
uuid: 1b1b61995c0d4d89a7f9ad4e14c3541f
name: 'Battery: Charge State'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.45.0
key: 'charge.state[chargeState.0]'
history: 7d
value_type: FLOAT
description: |
MIB: PROSTAR-MPPT
Charge State
Description:Control State
Modbus address:0x0021
0: Start
1: NightCheck
2: Disconnect
3: Night
4: Fault
5: BulkMppt
6: Absorption
7: Float
8: Equalize
9: Slave
10: Fixed
valuemap:
name: 'ProStar MPPT charge state'
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
-
tag: Application
value: Battery
triggers:
-
uuid: fe4863fdd4d64e1c977328bd3d0f687f
expression: 'last(/Morningstar ProStar MPPT SNMP/charge.state[chargeState.0])={$CHARGE.STATE.CRIT}'
name: 'Battery: Device charge in critical state'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 4d064e4877474d72b85c9cdfb7b09dad
expression: 'last(/Morningstar ProStar MPPT SNMP/charge.state[chargeState.0])={$CHARGE.STATE.WARN}'
name: 'Battery: Device charge in warning state'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'Battery: Device charge in critical state'
expression: 'last(/Morningstar ProStar MPPT SNMP/charge.state[chargeState.0])={$CHARGE.STATE.CRIT}'
-
uuid: 009eb72ff6674da49d1dd85a6f9459cf
name: 'Counter: Charge Amp-hours'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.49.0
key: 'counter.charge_amp_hours[ahChargeResettable.0]'
history: 7d
value_type: FLOAT
units: Ah
description: |
MIB: PROSTAR-MPPT
Ah Charge (Resettable)
Description:Ah Charge (Resettable)
Scaling Factor:0.1
Units:Ah
Range:[0.0, 4294967294]
Modbus addresses:H=0x0026 L=0x0027
preprocessing:
-
type: MULTIPLIER
parameters:
- '0.1'
tags:
-
tag: Application
value: Counter
-
uuid: 4a53a2211a1249d59369ad65762ffe47
name: 'Counter: Charge KW-hours'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.51.0
key: 'counter.charge_kw_hours[kwhChargeResettable.0]'
history: 7d
value_type: FLOAT
units: '!kWh'
description: |
MIB: PROSTAR-MPPT
kWh Charge (Resettable)
Description:Kilowatt Hours Charge (Resettable)
Scaling Factor:1.0
Units:kWh
Range:[0.0, 65535]
Modbus address:0x002A
tags:
-
tag: Application
value: Counter
-
uuid: c72ef851c2d240c9835c1703cec49fd6
name: 'Counter: Load Amp-hours'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.56.0
key: 'counter.load_amp_hours[ahLoadResettable.0]'
history: 7d
value_type: FLOAT
units: Ah
description: |
MIB: PROSTAR-MPPT
Description:Ah Load (Resettable)
Scaling Factor:0.1
Units:Ah
Range:[0.0, 4294967294]
Modbus addresses:H=0x0032 L=0x0033
preprocessing:
-
type: MULTIPLIER
parameters:
- '0.1'
tags:
-
tag: Application
value: Counter
-
uuid: 29a7d76472fb4025bc78fbeab273e955
name: 'Load: Current'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.34.0
key: 'load.current[loadCurrent.0]'
history: 7d
value_type: FLOAT
units: A
description: |
MIB: PROSTAR-MPPT
Load Current
Description:Load Current
Scaling Factor:1.0
Units:A
Range:[0, 60]
Modbus address:0x0016
tags:
-
tag: Application
value: Load
-
uuid: ae927b5cba5b43f5a2136fd3ee71b63d
name: 'Load: State'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.53.0
key: 'load.state[loadState.0]'
history: 7d
value_type: FLOAT
description: |
MIB: PROSTAR-MPPT
Load State
Description:Load State
Modbus address:0x002E
0: Start
1: Normal
2: LvdWarning
3: Lvd
4: Fault
5: Disconnect
6: NormalOff
7: Override
8: NotUsed
valuemap:
name: 'ProStar MPPT load state'
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
-
tag: Application
value: Load
triggers:
-
uuid: a88025c5e5a748e3a6dfa01685ba075b
expression: 'last(/Morningstar ProStar MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar ProStar MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"fault"}'
name: 'Load: Device load in critical state'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 9ab107b39b874fed83d09e7c1964a699
expression: 'last(/Morningstar ProStar MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.WARN:"lvdWarning"} or last(/Morningstar ProStar MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.WARN:"override"}'
name: 'Load: Device load in warning state'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'Load: Device load in critical state'
expression: 'last(/Morningstar ProStar MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar ProStar MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"fault"}'
-
uuid: 47894752dd1d41f1aa882387acf6dc3a
name: 'Load: Voltage'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.32.0
key: 'load.voltage[loadVoltage.0]'
history: 7d
value_type: FLOAT
units: V
description: |
MIB: PROSTAR-MPPT
Load Voltage
Description:Load Voltage
Scaling Factor:1.0
Units:V
Range:[0, 80]
Modbus address:0x0014
tags:
-
tag: Application
value: Load
-
uuid: d44cb5d7db31402dae79275a9148817d
name: 'Status: Alarms'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.59.0
key: 'status.alarms[alarms.0]'
history: 1h
trends: '0'
value_type: TEXT
description: |
MIB: PROSTAR-MPPT
Description:Alarms
Modbus addresses:H=0x0038 L=0x0039
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
-
type: JAVASCRIPT
parameters:
- |
var FIELDS = [
'rtsOpen',
'rtsShorted',
'rtsDisconnected',
'heatsinkTempSensorOpen',
'heatsinkTempSensorShorted',
'heatsinkTempLimit',
'inductorTempSensorOpen',
'inductorTempSensorShorted',
'inductorTempLimit',
'currentLimit',
'currentMeasurementError',
'batterySenseOutOfRange',
'batterySenseDisconnected',
'uncalibrated',
'tb5v',
'fp10SupplyOutOfRange',
'unused',
'mosfetOpen',
'arrayCurrentOffset',
'loadCurrentOffset',
'p33SupplyOutOfRange',
'p12SupplyOutOfRange',
'hightInputVoltageLimit',
'controllerReset',
'loadLvd',
'logTimeout',
'eepromAccessFailure'
];
var flags = parseInt(value.replace(/\x20/g, ''), 16),
result = [];
for (var i = 0, f = 1 << 31 >>> 0, l = FIELDS.length; i < l; i++, f >>>= 1) {
if (flags & f) {
result.push(FIELDS[i]);
}
}
return result.length ? result.join('\n') : 'No alarms';
tags:
-
tag: Application
value: Status
triggers:
-
uuid: 38add0e4701542eab6404fe213c890bc
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","arrayCurrentOffset")=2'
name: 'Status: Device has "arrayCurrentOffset" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 11474e381d6d4f2d9870387e090cbb91
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","batterySenseDisconnected")=2'
name: 'Status: Device has "batterySenseDisconnected" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: f6bb46bea26643fbb058c6c3f3761a6d
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","batterySenseOutOfRange")=2'
name: 'Status: Device has "batterySenseOutOfRange" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 10ed811580134f289068001249e7e2e9
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","controllerReset")=2'
name: 'Status: Device has "controllerReset" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 93ebc526f39245c1b8d3fe2c2fbc5ec6
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","currentLimit")=2'
name: 'Status: Device has "currentLimit" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 17d71bead9364fb5abc2dfaf78629dd4
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","currentMeasurementError")=2'
name: 'Status: Device has "currentMeasurementError" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 8f9301b6c6ad43c487a48670ed70f3fa
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","eepromAccessFailure")=2'
name: 'Status: Device has "eepromAccessFailure" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: d475ca449b644c52bfacba3777c1a1c0
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","fp10SupplyOutOfRange")=2'
name: 'Status: Device has "fp10SupplyOutOfRange" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 2664edbf44834f6fab7d1cb8fdbc2efb
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempLimit")=2'
name: 'Status: Device has "heatsinkTempLimit" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 2055c60cbcdc430cbdb5f9f53d0e22b2
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorOpen")=2'
name: 'Status: Device has "heatsinkTempSensorOpen" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: d5881c60240b449baecf88c2a82e267b
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorShorted")=2'
name: 'Status: Device has "heatsinkTempSensorShorted" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 0e288d130bca47a699d0b73f9bca6902
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","hightInputVoltageLimit")=2'
name: 'Status: Device has "hightInputVoltageLimit" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 67a16a3b9bd64fbd9f6305e28a513f3d
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","inductorTempLimit")=2'
name: 'Status: Device has "inductorTempLimit" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 49d5ef3f0a154017bab053a4e4341542
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","inductorTempSensorOpen")=2'
name: 'Status: Device has "inductorTempSensorOpen" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: a78c4d501bfb452486b4aed0b4bda00f
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","inductorTempSensorShorted")=2'
name: 'Status: Device has "inductorTempSensorShorted" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 3213610cba8e48d79f0099c0f6006ffe
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","loadCurrentOffset")=2'
name: 'Status: Device has "loadCurrentOffset" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 53096949f10841029e89ca78187e0e54
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","loadLvd")=2'
name: 'Status: Device has "loadLvd" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 84b0d70348394289a352957ca1f72bea
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","logTimeout")=2'
name: 'Status: Device has "logTimeout" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 402d663a3c1d4431bd1427452e1c9995
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","mosfetOpen")=2'
name: 'Status: Device has "mosfetOpen" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 4c0a1157e88b4bbb866e274a278b01ae
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","p12SupplyOutOfRange")=2'
name: 'Status: Device has "p12SupplyOutOfRange" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: a4de90fef5f54914abddcc13715087f9
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","p33SupplyOutOfRange")=2'
name: 'Status: Device has "p33SupplyOutOfRange" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 80fd749e5b04462a8291b00e2f3f3917
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","rtsDisconnected")=2'
name: 'Status: Device has "rtsDisconnected" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 0c54eea999274163a8bc7c019c722d0d
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","rtsShorted")=2'
name: 'Status: Device has "rtsShorted" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: ecaaec9b2fda4724ac23c2e440884b7f
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","tb5v")=2'
name: 'Status: Device has "tb5v" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: b7900423ca1147c9b3ef9f5cc0d6b784
expression: 'count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","uncalibrated")=2'
name: 'Status: Device has "uncalibrated" alarm flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
-
uuid: 8fbb5c650fa040c892a1d10a17fbbf14
name: 'Status: Array Faults'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.46.0
key: 'status.array_faults[arrayFaults.0]'
history: 1h
trends: '0'
value_type: TEXT
description: |
MIB: PROSTAR-MPPT
Description:Array Faults
Modbus address:0x0022
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
-
type: JAVASCRIPT
parameters:
- |
var FIELDS = [
'overcurrent',
'mosfetSShorted',
'software',
'batteryHvd',
'arrayHvd',
'customSettingsEdit',
'rtsShorted',
'rtsNoLongerValid',
'localTempSensorDamaged',
'batteryLowVoltageDisconnect',
'slaveTimeout',
'dipSwitchChanged',
];
var flags = parseInt(value.replace(/\x20/g, ''), 16),
result = [];
for (var i = 0, f = 1 << 31 >>> 0, l = FIELDS.length; i < l; i++, f >>>= 1) {
if (flags & f) {
result.push(FIELDS[i]);
}
}
return result.length ? result.join('\n') : 'No faults';
tags:
-
tag: Application
value: Status
triggers:
-
uuid: 7ec639a671dd418395eb22ade0034059
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","arrayHvd")=2'
name: 'Status: Device has "arrayHvd" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 38b26257e57449108f5d3859784c2486
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","batteryHvd")=2'
name: 'Status: Device has "batteryHvd" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: e79ea9870f8749498283bbb16dcc3d16
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","batteryLowVoltageDisconnect")=2'
name: 'Status: Device has "batteryLowVoltageDisconnect" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 352222e0738c420fb5c0c78dd85b63d5
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","customSettingsEdit")=2'
name: 'Status: Device has "customSettingsEdit" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 496ead435cc54182bff850b7d23d1956
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","dipSwitchChanged")=2'
name: 'Status: Device has "dipSwitchChanged" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: b9ea0bf233bd47958c48e9787c0de319
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","localTempSensorDamaged")=2'
name: 'Status: Device has "localTempSensorDamaged" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: bfa4cfe378fe4fea9a08219dbdc73a7f
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","mosfetSShorted")=2'
name: 'Status: Device has "mosfetSShorted" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 026961d66d3548d3a1bfa55ff2f545da
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","overcurrent")=2'
name: 'Status: Device has "overcurrent" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: d662417171eb407e84a56b1e7f2aed1e
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","rtsNoLongerValid")=2'
name: 'Status: Device has "rtsNoLongerValid" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 6325a6ce18ea4699b77ce91dfb16361e
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","rtsShorted")=2'
name: 'Status: Device has "rtsShorted" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 0f7a990edcdd4b0ab70588de6e2c4c62
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","slaveTimeout")=2'
name: 'Status: Device has "slaveTimeout" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 5787ca3ab1124c6b8aad76a65541eb7a
expression: 'count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","software")=2'
name: 'Status: Device has "software" array faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: fb4d2147a8224b599ad908eca1b019e4
name: 'Status: Load Faults'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.54.0
key: 'status.load_faults[loadFaults.0]'
history: 1h
trends: '0'
value_type: TEXT
description: |
MIB: PROSTAR-MPPT
Description:Array Faults
Modbus address:0x0022
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
-
type: JAVASCRIPT
parameters:
- |
var FIELDS = [
'externalShortCircuit',
'overcurrent',
'mosfetShorted',
'software',
'loadHvd',
'highTempDisconnect',
'dipSwitchChanged',
'customSettingsEdit'
];
var flags = parseInt(value.replace(/\x20/g, ''), 16),
result = [];
for (var i = 0, f = 1 << 31 >>> 0, l = FIELDS.length; i < l; i++, f >>>= 1) {
if (flags & f) {
result.push(FIELDS[i]);
}
}
return result.length ? result.join('\n') : 'No faults';
tags:
-
tag: Application
value: Status
triggers:
-
uuid: bfba4d2c13884342b30f72b513df39ee
expression: 'count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","customSettingsEdit")=2'
name: 'Status: Device has "customSettingsEdit" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 216bca0d366c4c2db387308a95cb1db0
expression: 'count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","dipSwitchChanged")=2'
name: 'Status: Device has "dipSwitchChanged" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 16068aeb99574612ba1f625f873c6e58
expression: 'count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","externalShortCircuit")=2'
name: 'Status: Device has "externalShortCircuit" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: b0cfd65085c34858a69121adb6b8a552
expression: 'count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","highTempDisconnect")=2'
name: 'Status: Device has "highTempDisconnect" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 019ece2873d042808fa943b93b8d3c33
expression: 'count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","loadHvd")=2'
name: 'Status: Device has "loadHvd" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 7685649fc49e42db9f953a4ef0595d23
expression: 'count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","mosfetShorted")=2'
name: 'Status: Device has "mosfetShorted" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 89d2f2e6ab01408eb931a764392fff48
expression: 'count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","overcurrent")=2'
name: 'Status: Device has "overcurrent" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 1093940ea3284565a35494bdc5674108
expression: 'count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","software")=2'
name: 'Status: Device has "software" load faults flag'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 526ee94df484462a9264e57d92954e64
name: 'Status: Uptime'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.2.1.1.3.0
key: status.uptime
history: 7d
units: uptime
description: 'Device uptime in seconds'
preprocessing:
-
type: MULTIPLIER
parameters:
- '0.01'
tags:
-
tag: Application
value: Status
triggers:
-
uuid: ca65a39c019046c29a522a6ca93ceb75
expression: 'last(/Morningstar ProStar MPPT SNMP/status.uptime)<10m'
name: 'Status: Device has been restarted (uptime < 10m)'
priority: INFO
description: 'Uptime is less than 10 minutes'
manual_close: 'YES'
-
uuid: 724df1f192a14120b82ea13093bf63ab
expression: 'nodata(/Morningstar ProStar MPPT SNMP/status.uptime,5m)=1'
name: 'Status: Failed to fetch data (or no data for 5m)'
priority: WARNING
description: 'Zabbix has not received data for items for the last 5 minutes'
manual_close: 'YES'
-
uuid: 20ce95acdff6486684461f10579a73b4
name: 'Battery: Target Voltage'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.48.0
key: 'target.voltage[targetVoltage.0]'
history: 7d
value_type: FLOAT
units: V
description: |
MIB: PROSTAR-MPPT
Target Voltage
Description:Target Regulation Voltage
Scaling Factor:1.0
Units:V
Range:[0.0, 80.0]
Modbus address:0x0024
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
-
tag: Application
value: Battery
-
uuid: 9a87cdcf65184059be334e986bcf801d
name: 'Temperature: Ambient'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.40.0
key: 'temp.ambient[ambientTemperature.0]'
history: 7d
value_type: FLOAT
units: C
description: |
MIB: PROSTAR-MPPT
Ambient Temperature
Description:Ambient Temperature
Scaling Factor:1.0
Units:deg C
Range:[-128, 127]
Modbus address:0x001C
tags:
-
tag: Application
value: Temperature
-
uuid: 1a8e79f49e86429abc80dd29598299ee
name: 'Temperature: Battery'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.39.0
key: 'temp.battery[batteryTemperature.0]'
history: 7d
value_type: FLOAT
units: C
description: |
MIB: PROSTAR-MPPT
Battery Temperature
Description:Battery Temperature
Scaling Factor:1.0
Units:deg C
Range:[-128, 127]
Modbus address:0x001B
tags:
-
tag: Application
value: Temperature
triggers:
-
uuid: de594b281866467397e993c24ee8e4ad
expression: 'min(/Morningstar ProStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}'
name: 'Temperature: Critically high battery temperature (over {$BATTERY.TEMP.MAX.CRIT}C for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 4f03e93cc7744715980dbbdd1d5b7b5d
expression: 'max(/Morningstar ProStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}'
name: 'Temperature: Critically low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: acd178214cf141b8b22ece12b173dfb6
expression: 'min(/Morningstar ProStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.WARN}'
name: 'Temperature: High battery temperature (over {$BATTERY.TEMP.MAX.WARN}C for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'Temperature: Critically high battery temperature (over {$BATTERY.TEMP.MAX.CRIT}C for 5m)'
expression: 'min(/Morningstar ProStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}'
-
uuid: 3e6aff58601a4ddab59a69d1a28ebfc3
expression: 'max(/Morningstar ProStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.WARN}'
name: 'Temperature: Low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'Temperature: Critically low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)'
expression: 'max(/Morningstar ProStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}'
-
uuid: 7d0cf28c0d334154971738df11775d1f
name: 'Temperature: Heatsink'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.38.0
key: 'temp.heatsink[heatsinkTemperature.0]'
history: 7d
value_type: FLOAT
units: C
description: |
MIB: PROSTAR-MPPT
Heatsink Temperature
Description:Heatsink Temperature
Scaling Factor:1.0
Units:deg C
Range:[-128, 127]
Modbus address:0x001A
tags:
-
tag: Application
value: Temperature
discovery_rules:
-
uuid: 1a21c30663c74c23b60e6ad72e228681
name: 'Battery voltage discovery'
type: DEPENDENT
key: battery.voltage.discovery
delay: '0'
description: 'Discovery for battery voltage triggers'
item_prototypes:
-
uuid: c02c73a349ec4a6b8557e142c4866148
name: 'Battery: Voltage{#SINGLETON}'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.33333.5.30.0
key: 'battery.voltage[batteryTerminalVoltage.0{#SINGLETON}]'
history: 7d
value_type: FLOAT
units: V
description: |
MIB: PROSTAR-MPPT
Battery Terminal Voltage
Description:Battery Terminal Voltage
Scaling Factor:1.0
Units:V
Range:[0.0, 80.0]
Modbus address:0x0012
tags:
-
tag: Application
value: Battery
trigger_prototypes:
-
uuid: 82b7e4818cdd4508a22239122370d8b8
expression: 'min(/Morningstar ProStar MPPT SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}'
name: 'Battery: Critically high battery voltage (over {#VOLTAGE.MAX.CRIT}V for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 056360e5d0b54843b8e556a8fd98331f
expression: 'max(/Morningstar ProStar MPPT SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}'
name: 'Battery: Critically low battery voltage (below {#VOLTAGE.MIN.CRIT}V for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
-
uuid: 7eb1afecdd514bab8a89dd21933d17a6
expression: 'min(/Morningstar ProStar MPPT SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.WARN}'
name: 'Battery: High battery voltage (over {#VOLTAGE.MAX.WARN}V for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'Battery: Critically high battery voltage (over {#VOLTAGE.MAX.CRIT}V for 5m)'
expression: 'min(/Morningstar ProStar MPPT SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}'
-
uuid: d04ed6ef79234d279443cae0aebd1aa8
expression: 'max(/Morningstar ProStar MPPT SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.WARN}'
name: 'Battery: Low battery voltage (below {#VOLTAGE.MIN.WARN}V for 5m)'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'Battery: Critically low battery voltage (below {#VOLTAGE.MIN.CRIT}V for 5m)'
expression: 'max(/Morningstar ProStar MPPT SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}'
graph_prototypes:
-
uuid: 480e4c11060a4e34851b48bf7b9c5bb1
name: 'Voltage: Battery/Load{#SINGLETON}'
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Morningstar ProStar MPPT SNMP'
key: 'battery.voltage[batteryTerminalVoltage.0{#SINGLETON}]'
-
sortorder: '1'
drawtype: GRADIENT_LINE
color: 2774A4
item:
host: 'Morningstar ProStar MPPT SNMP'
key: 'load.voltage[loadVoltage.0]'
master_item:
key: 'battery.voltage.discovery[batteryTerminalVoltage.0]'
preprocessing:
-
type: JAVASCRIPT
parameters:
- |
var v_range = [
[[0, 18], [12, 15, 11.5, 15.5]],
[[18, 36], [24, 30, 23, 31]],
[[36, 99], [48, 60, 46, 62]],
],
result = [];
for (var idx in v_range) {
if (v_range[idx][0][0] < value && value <= v_range[idx][0][1]) {
result = [{
'{#VOLTAGE.MIN.WARN}': parseInt({$VOLTAGE.MIN.WARN}) || v_range[idx][1][0],
'{#VOLTAGE.MAX.WARN}': parseInt({$VOLTAGE.MAX.WARN}) || v_range[idx][1][1],
'{#VOLTAGE.MIN.CRIT}': parseInt({$VOLTAGE.MIN.CRIT}) || v_range[idx][1][2],
'{#VOLTAGE.MAX.CRIT}': parseInt({$VOLTAGE.MAX.CRIT}) || v_range[idx][1][3],
'{#SINGLETON}': ''
}];
break;
}
}
return JSON.stringify(result);
macros:
-
macro: '{$BATTERY.TEMP.MAX.CRIT}'
value: '60'
description: 'Battery high temperature critical value'
-
macro: '{$BATTERY.TEMP.MAX.WARN}'
value: '45'
description: 'Battery high temperature warning value'
-
macro: '{$BATTERY.TEMP.MIN.CRIT}'
value: '-20'
description: 'Battery low temperature critical value'
-
macro: '{$BATTERY.TEMP.MIN.WARN}'
value: '0'
description: 'Battery low temperature warning value'
-
macro: '{$CHARGE.STATE.CRIT}'
value: '4'
description: fault
-
macro: '{$CHARGE.STATE.WARN}'
value: '2'
description: disconnect
-
macro: '{$LOAD.STATE.CRIT:"fault"}'
value: '4'
description: fault
-
macro: '{$LOAD.STATE.CRIT:"lvd"}'
value: '3'
description: lvd
-
macro: '{$LOAD.STATE.WARN:"disconnect"}'
value: '5'
description: disconnect
-
macro: '{$LOAD.STATE.WARN:"lvdWarning"}'
value: '2'
description: lvdWarning
-
macro: '{$LOAD.STATE.WARN:"override"}'
value: '7'
description: override
-
macro: '{$VOLTAGE.MAX.CRIT}'
-
macro: '{$VOLTAGE.MAX.WARN}'
-
macro: '{$VOLTAGE.MIN.CRIT}'
-
macro: '{$VOLTAGE.MIN.WARN}'
valuemaps:
-
uuid: 1703c3aeb1b24641821e1c6d2cb4c8b7
name: 'ProStar MPPT charge state'
mappings:
-
value: '0'
newvalue: Start
-
value: '1'
newvalue: NightCheck
-
value: '2'
newvalue: Disconnect
-
value: '3'
newvalue: Night
-
value: '4'
newvalue: Fault
-
value: '5'
newvalue: BulkMppt
-
value: '6'
newvalue: Absorption
-
value: '7'
newvalue: Float
-
value: '8'
newvalue: Equalize
-
value: '9'
newvalue: Slave
-
value: '10'
newvalue: Fixed
-
uuid: b5403a0805a54b9294f69a1e11a438b1
name: 'ProStar MPPT load state'
mappings:
-
value: '0'
newvalue: Start
-
value: '1'
newvalue: Normal
-
value: '2'
newvalue: LvdWarning
-
value: '3'
newvalue: Lvd
-
value: '4'
newvalue: Fault
-
value: '5'
newvalue: Disconnect
-
value: '6'
newvalue: NormalOff
-
value: '7'
newvalue: Override
-
value: '8'
newvalue: NotUsed
graphs:
-
uuid: 0662dc480c2b487e9f9afc389166a15b
name: 'Array: Voltage'
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Morningstar ProStar MPPT SNMP'
key: 'array.sweep_vmp[arrayVmp.0]'
-
sortorder: '1'
drawtype: GRADIENT_LINE
color: 2774A4
item:
host: 'Morningstar ProStar MPPT SNMP'
key: 'array.sweep_voc[arrayVoc.0]'
-
sortorder: '2'
drawtype: GRADIENT_LINE
color: F63100
item:
host: 'Morningstar ProStar MPPT SNMP'
key: 'array.voltage[arrayVoltage.0]'
-
uuid: 94bbfd8a60a8412998ff617011db9372
name: 'Current: Charge/Load'
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Morningstar ProStar MPPT SNMP'
key: 'charge.current[chargeCurrent.0]'
-
sortorder: '1'
drawtype: GRADIENT_LINE
color: 2774A4
item:
host: 'Morningstar ProStar MPPT SNMP'
key: 'load.current[loadCurrent.0]'
-
uuid: 02652b1251244702bf28f691e72ba27e
name: 'Temperature: Ambient/Battery/Heatsink'
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Morningstar ProStar MPPT SNMP'
key: 'temp.ambient[ambientTemperature.0]'
-
sortorder: '1'
drawtype: GRADIENT_LINE
color: 2774A4
item:
host: 'Morningstar ProStar MPPT SNMP'
key: 'temp.battery[batteryTemperature.0]'
-
sortorder: '2'
drawtype: GRADIENT_LINE
color: F63100
item:
host: 'Morningstar ProStar MPPT SNMP'
key: 'temp.heatsink[heatsinkTemperature.0]'
|