blob: a4a7f0361fc2c2dcd24c89f9f594813c24cb61fe (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
|
zabbix_export:
version: '5.4'
date: '2021-05-09T00:00:00Z'
groups:
-
name: 'Templates/Network devices'
templates:
-
template: 'TP-LINK SNMP'
name: 'TP-LINK SNMP'
description: |
Template Net TP-LINK
MIBs used:
TPLINK-SYSINFO-MIB
TPLINK-SYSMONITOR-MIB
Known Issues:
Description: Default sysLocation, sysName and sysContact is not filled with proper data. Real hostname and location can be found only in private branch (TPLINK-SYSINFO-MIB). Please check whether this problem exists in the latest firmware: https://www.tp-link.com/en/support/download/t2600g-28ts/#Firmware
Version: 2.0.0 Build 20170628 Rel.55184 (Beta)
Device: T2600G-28TS 2.0
Description: The Serial number of the product (tpSysInfoSerialNum) is missing in HW versions prior to V2_170323
Version: Prior to version V2_170323
Device: T2600G-28TS 2.0
Template tooling version used: 0.38
templates:
-
name: 'Generic SNMP'
-
name: 'Interfaces Simple SNMP'
groups:
-
name: 'Templates/Network devices'
items:
-
name: 'Firmware version'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.11863.6.1.1.6.0
key: system.hw.firmware
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: |
MIB: TPLINK-SYSINFO-MIB
The software version of the product.
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
triggers:
-
expression: '(last(/TP-LINK SNMP/system.hw.firmware,#1)<>last(/TP-LINK SNMP/system.hw.firmware,#2))=1 and length(last(/TP-LINK SNMP/system.hw.firmware))>0'
name: 'Firmware has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Firmware version has changed. Ack to close'
manual_close: 'YES'
-
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.11863.6.1.1.5.0
key: system.hw.model
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: |
MIB: TPLINK-SYSINFO-MIB
The hardware version of the product.
inventory_link: MODEL
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
-
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.11863.6.1.1.8.0
key: system.hw.serialnumber
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: |
MIB: TPLINK-SYSINFO-MIB
The Serial number of the product.
inventory_link: SERIALNO_A
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
triggers:
-
expression: '(last(/TP-LINK SNMP/system.hw.serialnumber,#1)<>last(/TP-LINK SNMP/system.hw.serialnumber,#2))=1 and length(last(/TP-LINK SNMP/system.hw.serialnumber))>0'
name: 'Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Ack to close'
manual_close: 'YES'
-
name: 'Hardware version(revision)'
type: SNMP_AGENT
snmp_oid: 1.3.6.1.4.1.11863.6.1.1.5.0
key: system.hw.version
delay: 1h
history: 2w
trends: '0'
value_type: CHAR
description: |
MIB: TPLINK-SYSINFO-MIB
The hardware version of the product.
preprocessing:
-
type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
-
tag: Application
value: Inventory
discovery_rules:
-
name: 'CPU Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.11863.6.4.1.1.1.1.1]'
key: cpu.discovery
delay: 1h
description: 'Discovering TPLINK-SYSMONITOR-MIB::tpSysMonitorCpuTable, displays the CPU utilization of all UNITs.'
item_prototypes:
-
name: '#{#SNMPVALUE}: CPU utilization'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.11863.6.4.1.1.1.1.3.{#SNMPINDEX}'
key: 'system.cpu.util[tpSysMonitorCpu1Minute.{#SNMPINDEX}]'
history: 7d
value_type: FLOAT
units: '%'
description: |
MIB: TPLINK-SYSMONITOR-MIB
Displays the CPU utilization in 1 minute.
Reference: http://www.tp-link.com/faq-1330.html
tags:
-
tag: Application
value: CPU
trigger_prototypes:
-
expression: 'min(/TP-LINK SNMP/system.cpu.util[tpSysMonitorCpu1Minute.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
name: '#{#SNMPVALUE}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
opdata: 'Current utilization: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'CPU utilization is too high. The system might be slow to respond.'
graph_prototypes:
-
name: '#{#SNMPVALUE}: CPU utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'TP-LINK SNMP'
key: 'system.cpu.util[tpSysMonitorCpu1Minute.{#SNMPINDEX}]'
-
name: 'Memory Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.11863.6.4.1.2.1.1.1]'
key: memory.discovery
delay: 1h
description: 'Discovering TPLINK-SYSMONITOR-MIB::tpSysMonitorMemoryTable, displays the memory utilization of all UNITs.'
item_prototypes:
-
name: '#{#SNMPVALUE}: Memory utilization'
type: SNMP_AGENT
snmp_oid: '1.3.6.1.4.1.11863.6.4.1.2.1.1.2.{#SNMPINDEX}'
key: 'vm.memory.util[tpSysMonitorMemoryUtilization.{#SNMPINDEX}]'
history: 7d
value_type: FLOAT
units: '%'
description: |
MIB: TPLINK-SYSMONITOR-MIB
Displays the memory utilization.
Reference: http://www.tp-link.com/faq-1330.html
tags:
-
tag: Application
value: Memory
trigger_prototypes:
-
expression: 'min(/TP-LINK SNMP/vm.memory.util[tpSysMonitorMemoryUtilization.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
name: '#{#SNMPVALUE}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
priority: AVERAGE
description: 'The system is running out of free memory.'
graph_prototypes:
-
name: '#{#SNMPVALUE}: Memory utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
-
drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'TP-LINK SNMP'
key: 'vm.memory.util[tpSysMonitorMemoryUtilization.{#SNMPINDEX}]'
macros:
-
macro: '{$CPU.UTIL.CRIT}'
value: '90'
-
macro: '{$MEMORY.UTIL.MAX}'
value: '90'
|