Welcome to mirror list, hosted at ThFree Co, Russian Federation.

template_power_apc_ups_symmetra_rx_snmp.yaml « apc_ups_symmetra_rx_snmp « apc « power « templates - github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
blob: 08fbe55ab6b1c136505b1173e720e41b9da4aa48 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
zabbix_export:
  version: '5.4'
  date: '2021-05-11T08:04:58Z'
  groups:
    -
      uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
      name: Templates/Power
  templates:
    -
      uuid: 4ffb0f9103084384a98379ed533865e9
      template: 'APC UPS Symmetra RX SNMP'
      name: 'APC UPS Symmetra RX SNMP'
      description: |
        Template Power APC UPS Symmetra RX
        
        MIBs used:
        PowerNet-MIB
        SNMPv2-MIB
        
        You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/420730-discussion-thread-for-official-zabbix-template-apc-ups
        
        Template tooling version used: 0.38
      groups:
        -
          name: Templates/Power
      items:
        -
          uuid: 0f45eeef24724e3b89760b04bfd037ae
          name: 'Battery capacity'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.1.0
          key: 'battery.capacity[upsHighPrecBatteryCapacity]'
          history: 7d
          value_type: FLOAT
          units: '%'
          description: |
            MIB: PowerNet-MIB
            The remaining battery capacity expressed as
             percentage of full capacity.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
          triggers:
            -
              uuid: 5626e87891ec4c28a17a6b5965b47e46
              expression: 'last(/APC UPS Symmetra RX SNMP/battery.capacity[upsHighPrecBatteryCapacity]) < {$BATTERY.CAPACITY.MIN.WARN}'
              name: 'Battery has low capacity (below {$BATTERY.CAPACITY.MIN.WARN}%)'
              opdata: 'Current capacity: {ITEM.LASTVALUE1}'
              priority: HIGH
        -
          uuid: a40074f9db134bc8bc4bd9800906137d
          name: 'External battery packs count'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.5.0
          key: 'battery.external_packs_count[upsAdvBatteryNumOfBattPacks]'
          delay: 1h
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The number of external battery packs connected to the UPS. If
             the UPS does not use smart cells then the agent reports
             ERROR_NO_SUCH_NAME.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
        -
          uuid: c069bb03f58a47b981448a33a1663463
          name: 'Battery last replace date'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.1.3.0
          key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
          delay: 1h
          history: 7d
          trends: '0'
          value_type: CHAR
          description: |
            MIB: PowerNet-MIB
            The date when the UPS system's batteries were last replaced
             in mm/dd/yy (or yyyy) format. For Smart-UPS models, this value
             is originally set at the factory. When the UPS batteries
             are replaced, this value should be reset by the administrator.
             For Symmetra PX 250/500 this OID is read-only and is configurable in the local display only.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
        -
          uuid: 810c9cd371c14e44b8670ad3f4e003d5
          name: 'Battery replace indicator'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.4.0
          key: 'battery.replace_indicator[upsAdvBatteryReplaceIndicator]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            Indicates whether the UPS batteries need replacement.
          valuemap:
            name: 'PowerNet-MIB::upsAdvBatteryReplaceIndicator'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
          triggers:
            -
              uuid: a74eccd4442c401a98ac3c80dd3baa13
              expression: 'last(/APC UPS Symmetra RX SNMP/battery.replace_indicator[upsAdvBatteryReplaceIndicator])=2'
              name: 'Battery needs replacement'
              priority: HIGH
              description: 'A battery installed has an internal error condition.'
        -
          uuid: 849b9ffa0c0b4dd59e7c5a544a135fa3
          name: 'Battery runtime remaining'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.3.0
          key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
          history: 7d
          value_type: FLOAT
          units: s
          description: |
            MIB: PowerNet-MIB
            The UPS battery run time remaining before battery
             exhaustion.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.01'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
        -
          uuid: a5ccdee4e5ff49f183adab8a283e88a0
          name: 'Battery status'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.1.1.0
          key: 'battery.status[upsBasicBatteryStatus]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The status of the UPS batteries. A batteryLow(3) value
             indicates the UPS will be unable to sustain the current
             load, and its services will be lost if power is not restored.
             The amount of run time in reserve at the time of low battery
             can be configured by the upsAdvConfigLowBatteryRunTime.
             A batteryInFaultCondition(4)value indicates that a battery
             installed has an internal error condition.
          valuemap:
            name: 'PowerNet-MIB::upsBasicBatteryStatus'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
          triggers:
            -
              uuid: 107454c372cb413bad4d4a807c254ae0
              expression: 'last(/APC UPS Symmetra RX SNMP/battery.status[upsBasicBatteryStatus])=4'
              name: 'Battery has an internal error condition'
              priority: AVERAGE
              description: 'A battery installed has an internal error condition.'
            -
              uuid: 4a410279dba04d37924eade4bb927228
              expression: 'last(/APC UPS Symmetra RX SNMP/battery.status[upsBasicBatteryStatus])=3'
              name: 'Battery is Low'
              priority: AVERAGE
              description: 'The UPS will be unable to sustain the current load, and its services will be lost if power is not restored.'
        -
          uuid: 59cc2d65eca142adb00ec80e237b134e
          name: 'Battery temperature'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.2.0
          key: 'battery.temperature[upsHighPrecBatteryTemperature]'
          history: 7d
          value_type: FLOAT
          units: ℃
          description: |
            MIB: PowerNet-MIB
            The current internal UPS temperature in Celsius.
             Temperatures below zero read as 0.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
          triggers:
            -
              uuid: 225ccc34992f4c718277b436bfecdc72
              expression: 'min(/APC UPS Symmetra RX SNMP/battery.temperature[upsHighPrecBatteryTemperature],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}'
              name: 'Battery has high temperature (over {$BATTERY.TEMP.MAX.WARN}℃ for {$TIME.PERIOD})'
              opdata: 'Current temperature: {ITEM.LASTVALUE1}'
              priority: HIGH
        -
          uuid: ae8516a825b94d90b267371934bc452f
          name: 'Battery voltage'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.4.0
          key: 'battery.voltage[upsHighPrecBatteryActualVoltage]'
          history: 7d
          value_type: FLOAT
          units: V
          description: |
            MIB: PowerNet-MIB
            The actual battery bus voltage in Volts.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
        -
          uuid: 598c1b4cc957455b84c2edcbe844e169
          name: 'Input fail cause'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.2.5.0
          key: 'input.fail[upsAdvInputLineFailCause]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The reason for the occurrence of the last transfer to UPS
            battery power.  The variable is set to:
            - noTransfer(1) -- if there is no transfer yet.
            - highLineVoltage(2) -- if the transfer to battery is caused
            by an over voltage greater than the high transfer voltage.
            - brownout(3) -- if the duration of the outage is greater than
            five seconds and the line voltage is between 40% of the
            rated output voltage and the low transfer voltage.
            - blackout(4) -- if the duration of the outage is greater than five
            seconds and the line voltage is between 40% of the rated
            output voltage and ground.
            - smallMomentarySag(5) -- if the duration of the outage is less
            than five seconds and the line voltage is between 40% of the
            rated output voltage and the low transfer voltage.
            - deepMomentarySag(6) -- if the duration of the outage is less
            than five seconds and the line voltage is between 40% of the
            rated output voltage and ground.  The variable is set to
            - smallMomentarySpike(7) -- if the line failure is caused by a
            rate of change of input voltage less than ten volts per cycle.
            - largeMomentarySpike(8) -- if the line failure is caused by
            a rate of change of input voltage greater than ten volts per cycle.
            - selfTest(9) -- if the UPS was commanded to do a self test.
            - rateOfVoltageChange(10) -- if the failure is due to the rate of change of
            the line voltage.
          valuemap:
            name: 'PowerNet-MIB::upsAdvInputLineFailCause'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
        -
          uuid: 8ab48c798ac94773b37228a8f725efd0
          name: 'Input frequency'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.3.4.0
          key: 'input.frequency[upsHighPrecInputFrequency]'
          history: 7d
          value_type: FLOAT
          units: Hz
          description: |
            MIB: PowerNet-MIB
            The current input frequency to the UPS system in Hz.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
          triggers:
            -
              uuid: 03b674d215604dc8acc3449610b05878
              expression: 'min(/APC UPS Symmetra RX SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > 0 and (min(/APC UPS Symmetra RX SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > {$UPS.INPUT_FREQ.MAX.WARN} or max(/APC UPS Symmetra RX SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) < {$UPS.INPUT_FREQ.MIN.WARN})'
              name: 'Unacceptable input frequency (out of range {$UPS.INPUT_FREQ.MIN.WARN}-{$UPS.INPUT_FREQ.MAX.WARN}Hz for {$TIME.PERIOD})'
              opdata: 'Current frequency: {ITEM.LASTVALUE1}'
              priority: HIGH
        -
          uuid: 5478b17ba84c4f12bc1ffa7dfc507ae1
          name: 'Input voltage'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.3.1.0
          key: 'input.voltage[upsHighPrecInputLineVoltage]'
          history: 7d
          value_type: FLOAT
          units: V
          description: |
            MIB: PowerNet-MIB
            The current utility line voltage in VAC.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
          triggers:
            -
              uuid: bf495f3ffefd4e65af488d91b360539c
              expression: 'min(/APC UPS Symmetra RX SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > 0 and (min(/APC UPS Symmetra RX SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RX SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN})'
              name: 'Unacceptable input voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})'
              opdata: 'Current voltage: {ITEM.LASTVALUE1}'
              priority: HIGH
        -
          uuid: 71cfc894a29f4bffb1f4199e0010aea0
          name: 'Output current'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.3.4.0
          key: 'output.current[upsHighPrecOutputCurrent]'
          history: 7d
          value_type: FLOAT
          units: A
          description: |
            MIB: PowerNet-MIB
            The current in amperes drawn by the load on the UPS.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
        -
          uuid: 3ac052b6b4e241d9af470b70212ab8d3
          name: 'Output load'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.3.3.0
          key: 'output.load[upsHighPrecOutputLoad]'
          history: 7d
          value_type: FLOAT
          units: '%'
          description: |
            MIB: PowerNet-MIB
            The current UPS load expressed as percentage
            of rated capacity.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
          triggers:
            -
              uuid: f2790aa869724c5bbeff6031561f2ca4
              expression: 'min(/APC UPS Symmetra RX SNMP/output.load[upsHighPrecOutputLoad],{$TIME.PERIOD}) > {$UPS.OUTPUT.MAX.WARN}'
              name: 'Output load is high (over {$UPS.OUTPUT.MAX.WARN}% for {$TIME.PERIOD})'
              opdata: 'Current load: {ITEM.LASTVALUE1}'
              priority: HIGH
              description: 'A battery installed has an internal error condition.'
        -
          uuid: f8e4bcaa71e045e09af82ee739202778
          name: 'Output status'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.1.1.0
          key: 'output.status[upsBasicOutputStatus]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The current state of the UPS. If the UPS is unable to
             determine the state of the UPS this variable is set
             to unknown(1).
            During self-test most UPSes report onBattery(3) but
             some that support it will report onBatteryTest(15).
             To determine self-test status across all UPSes, refer
             to the upsBasicStateOutputState OID.
          valuemap:
            name: 'PowerNet-MIB::upsBasicOutputStatus'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
          triggers:
            -
              uuid: 48a2bee152664ede98bed55c05cc437d
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=16'
              name: 'UPS is Emergency Static Bypass'
              priority: AVERAGE
            -
              uuid: ccd80d5877e0401b8f56f22ca2da2f94
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=10'
              name: 'UPS is Hardware Failure Bypass'
              priority: AVERAGE
            -
              uuid: e54fd69ac4354716a107d4d094b387f0
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=7'
              name: 'UPS is Off'
              priority: AVERAGE
            -
              uuid: 92df44ef170d471394f4cf8ff6882c39
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=3'
              name: 'UPS is on battery'
              priority: AVERAGE
            -
              uuid: b6f6c160466e43d8b7f210b2efdd8ca3
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=4'
              name: 'UPS is on Smart Boost'
              priority: AVERAGE
            -
              uuid: 7d6323e1a03a48efb9f349ecd7e10153
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=12'
              name: 'UPS is On Smart Trim'
              priority: AVERAGE
            -
              uuid: 18a31f11313b47c8ab9e9cd4791c1532
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=8'
              name: 'UPS is Rebooting'
              priority: AVERAGE
            -
              uuid: 142e25b05d1547f0a683f6caee773ef5
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=11'
              name: 'UPS is Sleeping Until Power Return'
              priority: AVERAGE
            -
              uuid: b6e22e8295c84fbebb8061c96ddd75f9
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=6'
              name: 'UPS is Software Bypass'
              priority: AVERAGE
            -
              uuid: 1c97c8ca6d6640fe829bf896f989bd91
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=9'
              name: 'UPS is Switched Bypass'
              priority: AVERAGE
            -
              uuid: 0683dbba9f4b4480ba15e040b8b83211
              expression: 'last(/APC UPS Symmetra RX SNMP/output.status[upsBasicOutputStatus])=5'
              name: 'UPS is Timed Sleeping'
              priority: AVERAGE
        -
          uuid: e7969358cce84f3eb749b1c43d96c583
          name: 'Output voltage'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.3.1.0
          key: 'output.voltage[upsHighPrecOutputVoltage]'
          history: 7d
          value_type: FLOAT
          units: V
          description: |
            MIB: PowerNet-MIB
            The output voltage of the UPS system in VAC.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
        -
          uuid: c892c7f2ddcd4e15b1d5ab907cd70dcf
          name: 'SNMP traps (fallback)'
          type: SNMP_TRAP
          key: snmptrap.fallback
          history: 2w
          trends: '0'
          value_type: LOG
          description: 'Item is used to collect all SNMP traps unmatched by other snmptrap items'
          logtimefmt: 'hh:mm:sszyyyy/MM/dd'
          tags:
            -
              tag: General
        -
          uuid: 1de71b45323b4eb5bc1a38315d56ce58
          name: 'System contact details'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.4.0
          key: 'system.contact[sysContact.0]'
          delay: 1h
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The textual identification of the contact person for this managed
            node, together with information on how to contact this person.  If no contact
            information is known, the value is the zero-length string.
          inventory_link: CONTACT
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 1d
          tags:
            -
              tag: General
        -
          uuid: 9bca97c1e308421b82f4769151f5177e
          name: 'System description'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.1.0
          key: 'system.descr[sysDescr.0]'
          delay: 1h
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            A textual description of the entity. This value should
            include the full name and version identification of the system's hardware type, software operating-system, and
            networking software.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 1d
          tags:
            -
              tag: General
        -
          uuid: be1280a6b2d84393ad001113bf7c80f2
          name: 'System location'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.6.0
          key: 'system.location[sysLocation.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The physical location of this node (e.g., `telephone closet,
            3rd floor').  If the location is unknown, the value is the zero-length string.
          inventory_link: LOCATION
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: General
        -
          uuid: 5c5b88814e4c4dc9b90ed4a5e49a91ca
          name: Model
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.1.1.1.0
          key: 'system.model[upsBasicIdentModel]'
          delay: 15m
          history: 7d
          trends: '0'
          value_type: CHAR
          description: |
            MIB: PowerNet-MIB
            The UPS model name (e.g. 'APC Smart-UPS 600').
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: General
        -
          uuid: 3c521e1e94da4dd2bd71719bf20e14b8
          name: 'System name'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.5.0
          key: 'system.name[sysName.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            An administratively-assigned name for this managed node.By
            convention, this is the node's fully-qualified domain name.  If the name is unknown,
            the value is the zero-length string.
          inventory_link: NAME
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: General
          triggers:
            -
              uuid: 5224767a1bee42738c49361ddabfed4b
              expression: 'last(/APC UPS Symmetra RX SNMP/system.name[sysName.0],#1)<>last(/APC UPS Symmetra RX SNMP/system.name[sysName.0],#2) and length(last(/APC UPS Symmetra RX SNMP/system.name[sysName.0]))>0'
              name: 'System name has changed (new name: {ITEM.VALUE})'
              priority: INFO
              description: 'System name has changed. Ack to close.'
              manual_close: 'YES'
        -
          uuid: 0d3fcfce413a4f6aaaa2390183ab0c82
          name: 'System object ID'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.2.0
          key: 'system.objectid[sysObjectID.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The vendor's authoritative identification of the network management
            subsystem contained in the entity.  This value is allocated within the SMI enterprises
            subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what
            kind of box' is being managed.  For example, if vendor`Flintstones, Inc.' was
            assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1
            to its `Fred Router'.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: General
        -
          uuid: 0e72609b44094aff8acfa58b63ca97ba
          name: 'Serial number'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.1.2.3.0
          key: 'system.sn[upsAdvIdentSerialNumber]'
          delay: 15m
          history: 7d
          trends: '0'
          value_type: CHAR
          description: |
            MIB: PowerNet-MIB
            An 8-character string identifying the serial number of
             the UPS internal microprocessor.  This number is set at
             the factory.  NOTE: This number does NOT correspond to
             the serial number on the rear of the UPS.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: General
        -
          uuid: 4aac942cab30432d81c4df32e01af5e2
          name: Uptime
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.3.0
          key: 'system.uptime[sysUpTime.0]'
          delay: 30s
          history: 2w
          trends: 0d
          units: uptime
          description: |
            MIB: SNMPv2-MIB
            The time (in hundredths of a second) since the network management
            portion of the system was last re-initialized.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.01'
          tags:
            -
              tag: Status
          triggers:
            -
              uuid: 990c0545543c42a78022589838a8a1ff
              expression: 'last(/APC UPS Symmetra RX SNMP/system.uptime[sysUpTime.0])<10m'
              name: '{HOST.NAME} has been restarted (uptime < 10m)'
              priority: WARNING
              description: 'Uptime is less than 10 minutes'
              manual_close: 'YES'
              dependencies:
                -
                  name: 'No SNMP data collection'
                  expression: 'max(/APC UPS Symmetra RX SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
        -
          uuid: 582ff80b2df049b8acf233ad4dbfe1f1
          name: 'SNMP agent availability'
          type: INTERNAL
          key: 'zabbix[host,snmp,available]'
          history: 7d
          valuemap:
            name: zabbix.host.available
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: Status
          triggers:
            -
              uuid: c0ad0941746546aeb6de2fee087c8252
              expression: 'max(/APC UPS Symmetra RX SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
              name: 'No SNMP data collection'
              opdata: 'Current state: {ITEM.LASTVALUE1}'
              priority: WARNING
              description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
      discovery_rules:
        -
          uuid: eddb568fd0e34398bcee7d39a6f76319
          name: 'External bad battery packs discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#EXTERNAL_PACKS},1.3.6.1.4.1.318.1.1.1.2.2.6]'
          key: battery.packs.bad.discovery
          delay: 1h
          description: 'Discovery of the number of external defective battery packs.'
          item_prototypes:
            -
              uuid: 11c16d0e18a745679bcf8546cb8f0641
              name: '{#SNMPINDEX}: External battery packs bad'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.6.0
              key: 'battery.external_packs_bad[upsAdvBatteryNumOfBadBattPacks.{#SNMPINDEX}]'
              delay: 15m
              history: 7d
              description: |
                MIB: PowerNet-MIB
                The number of external battery packs connected to the UPS that
                are defective. If the UPS does not use smart cells then the
                agent reports ERROR_NO_SUCH_NAME.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
        -
          uuid: 0c31de1650b94f8cabef339e2ef009e3
          name: 'External battery packs discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#CARTRIDGE_STATUS},1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.7,{#BATTERY_PACK},1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.1,{#CARTRIDGE_INDEX},1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.2]'
          key: battery.packs.discovery
          delay: 1h
          filter:
            evaltype: AND
            conditions:
              -
                macro: '{#CARTRIDGE_STATUS}'
                value: ^$
                operator: NOT_MATCHES_REGEX
                formulaid: A
          item_prototypes:
            -
              uuid: 6bd2d90f306e4252b5fc44eab860f4ab
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery estimated replace date'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.8.{#SNMPINDEX}'
              key: 'battery.estimated_replace_date[upsHighPrecBatteryPackCartridgeReplaceDate.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              delay: 1h
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery cartridge estimated battery replace date.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
            -
              uuid: c4a7061be8f64f398ad0f3c52db29bbd
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery pack cartridge health'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.7.{#SNMPINDEX}'
              key: 'battery.pack.cartridge_health[upsHighPrecBatteryPackCartridgeHealth.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery cartridge health.
                  bit 0 Battery lifetime okay
                  bit 1 Battery lifetime near end, order replacement cartridge
                  bit 2 Battery lifetime exceeded, replace battery
                  bit 3 Battery lifetime near end acknowledged, order replacement cartridge
                  bit 4 Battery lifetime exceeded acknowledged, replace battery
                  bit 5 Battery measured lifetime near end, order replacement cartridge
                  bit 6 Battery measured lifetime near end acknowledged, order replacement cartridge
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
              trigger_prototypes:
                -
                  uuid: 3a48257337a84a2296db92410a8aed8c
                  expression: 'find(/APC UPS Symmetra RX SNMP/battery.pack.cartridge_health[upsHighPrecBatteryPackCartridgeHealth.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0)[0|1]{15}$")=1'
                  name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery lifetime is not okay'
                  opdata: 'Current bit set: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: |
                    The battery cartridge health.
                      bit 0 Battery lifetime okay
                      bit 1 Battery lifetime near end, order replacement cartridge
                      bit 2 Battery lifetime exceeded, replace battery
                      bit 3 Battery lifetime near end acknowledged, order replacement cartridge
                      bit 4 Battery lifetime exceeded acknowledged, replace battery
                      bit 5 Battery measured lifetime near end, order replacement cartridge
                      bit 6 Battery measured lifetime near end acknowledged, order replacement cartridge
            -
              uuid: 8f5b3a61acad491f8ca6860f6201252d
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.10.{#SNMPINDEX}'
              key: 'battery.pack.status[upsHighPrecBatteryPackCartridgeStatus.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery cartridge status.
                bit 0 Disconnected
                bit 1 Overvoltage
                bit 2 NeedsReplacement
                bit 3 OvertemperatureCritical
                bit 4 Charger
                bit 5 TemperatureSensor
                bit 6 BusSoftStart
                bit 7 OvertemperatureWarning
                bit 8 GeneralError
                bit 9 Communication
                bit 10 DisconnectedFrame
                bit 11 FirmwareMismatch
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
              trigger_prototypes:
                -
                  uuid: 4498d376328e405bad7da5f1832cde8a
                  expression: 'find(/APC UPS Symmetra RX SNMP/battery.pack.status[upsHighPrecBatteryPackCartridgeStatus.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0{16})$")=0'
                  name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery status is not okay'
                  opdata: 'Current bit set: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: |
                    The battery cartridge status:
                    bit 0 Disconnected
                    bit 1 Overvoltage
                    bit 2 NeedsReplacement
                    bit 3 OvertemperatureCritical
                    bit 4 Charger
                    bit 5 TemperatureSensor
                    bit 6 BusSoftStart
                    bit 7 OvertemperatureWarning
                    bit 8 GeneralError
                    bit 9 Communication
                    bit 10 DisconnectedFrame
                    bit 11 FirmwareMismatch
            -
              uuid: 346f2ab5b340401880c63a6cb9eec949
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery temperature'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.5.{#SNMPINDEX}'
              key: 'battery.temperature[upsHighPrecBatteryPackTemperature.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              history: 7d
              value_type: FLOAT
              units: ℃
              description: |
                MIB: PowerNet-MIB
                The battery pack temperature in Celsius.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.1'
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
              trigger_prototypes:
                -
                  uuid: f710e2b952054f35ab6e3e8e90ab7f83
                  expression: 'min(/APC UPS Symmetra RX SNMP/battery.temperature[upsHighPrecBatteryPackTemperature.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}'
                  name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery has high temperature (over {$BATTERY.TEMP.MAX.WARN}℃ for {$TIME.PERIOD})'
                  opdata: 'Current temperature: {ITEM.LASTVALUE1}'
                  priority: HIGH
            -
              uuid: 230fc138d8f64c4f9eeee438d42b519e
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Serial number'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.4.{#SNMPINDEX}'
              key: 'system.sn[upsHighPrecBatteryPackSerialNumber.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              delay: 15m
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery pack serial number.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: General
        -
          uuid: 93941e38fd2d4b48bd8b50179692cb56
          name: 'External sensor port 1 discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#EXTERNAL_SENSOR1_NAME},1.3.6.1.4.1.318.1.1.25.1.2.1.3]'
          key: external.sensor1.discovery
          delay: 1h
          description: uioSensorStatusTable
          item_prototypes:
            -
              uuid: 15f23c88f9b24580add63b69fb8a41de
              name: '{#EXTERNAL_SENSOR1_NAME}: Humidity sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.1.7.1.1
              key: 'external.sensor.humidity[uioSensorStatusHumidity.1.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: PowerNet-MIB
                The sensor's current humidity reading - a relative humidity
                 percentage. -1 indicates an invalid reading due to either a
                 sensor that doesn't read humidity or lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
            -
              uuid: 230f3e596bbc4cb6961eda599da74f5e
              name: '{#EXTERNAL_SENSOR1_NAME}: Sensor alarm status'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.1.9.1.1
              key: 'external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}]'
              history: 7d
              description: |
                MIB: PowerNet-MIB
                The alarm status of the sensor. Possible values:
                uioNormal                 (1),
                uioWarning                (2),
                uioCritical               (3),
                sensorStatusNotApplicable (4)
              valuemap:
                name: 'PowerNet-MIB::uioSensorStatusAlarmStatus'
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
              trigger_prototypes:
                -
                  uuid: 0de21ba7495d41f4834170122620c37d
                  expression: 'last(/APC UPS Symmetra RX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=3'
                  name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Critical'
                  priority: HIGH
                  description: 'The external sensor has returned a value greater than the critical threshold.'
                -
                  uuid: 69fbc11262f74fdfb49da43bb59c1810
                  expression: 'last(/APC UPS Symmetra RX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=4'
                  name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Not Applicable'
                  priority: INFO
                  description: 'The external sensor does not work or is not connected.'
                -
                  uuid: 0ce46cad353c4299ad5540a831b5c467
                  expression: 'last(/APC UPS Symmetra RX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=2'
                  name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Warning'
                  priority: AVERAGE
                  description: 'The external sensor has returned a value greater than the warning threshold.'
            -
              uuid: f777176e1d7b4e328209aeeced8e680b
              name: '{#EXTERNAL_SENSOR1_NAME}: Temperature sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.1.6.1.1
              key: 'external.sensor.temperature[uioSensorStatusTemperatureDegC.1.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: ℃
              description: |
                MIB: PowerNet-MIB
                The sensor's current temperature reading in Celsius.
                 -1 indicates an invalid reading due to lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
          overrides:
            -
              name: Temp
              step: '1'
              filter:
                conditions:
                  -
                    macro: '{#EXTERNAL_SENSOR1_NAME}'
                    value: Temp
                    formulaid: A
              operations:
                -
                  operationobject: ITEM_PROTOTYPE
                  operator: LIKE
                  value: Humidity
                  status: ENABLED
                  discover: NO_DISCOVER
        -
          uuid: 7cd4c33584004a6d811478e8a83e0898
          name: 'External sensor port 2 discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#EXTERNAL_SENSOR2_NAME},1.3.6.1.4.1.318.1.1.25.1.2.2.3]'
          key: external.sensor2.discovery
          delay: 1h
          description: uioSensorStatusTable
          item_prototypes:
            -
              uuid: 3a933ac0f9b2425d9929ed244a3ce61a
              name: '{#EXTERNAL_SENSOR2_NAME}: Humidity sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.2.7.1.1
              key: 'external.sensor.humidity[uioSensorStatusHumidity.2.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: PowerNet-MIB
                The sensor's current humidity reading - a relative humidity
                 percentage. -1 indicates an invalid reading due to either a
                 sensor that doesn't read humidity or lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
            -
              uuid: b8a37686d5374b4fa05717987e54c2f6
              name: '{#EXTERNAL_SENSOR2_NAME}: Sensor alarm status'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.2.9.1.1
              key: 'external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}]'
              history: 7d
              description: |
                MIB: PowerNet-MIB
                The alarm status of the sensor. Possible values:
                uioNormal                 (1),
                uioWarning                (2),
                uioCritical               (3),
                sensorStatusNotApplicable (4)
              valuemap:
                name: 'PowerNet-MIB::uioSensorStatusAlarmStatus'
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
              trigger_prototypes:
                -
                  uuid: f27f80f391a04927bb138ba66d48d364
                  expression: 'last(/APC UPS Symmetra RX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=3'
                  name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Critical'
                  priority: HIGH
                  description: 'The external sensor has returned a value greater than the critical threshold.'
                -
                  uuid: a84e1b5140b643ad8bee020d74821255
                  expression: 'last(/APC UPS Symmetra RX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=4'
                  name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Not Applicable'
                  priority: INFO
                  description: 'The external sensor does not work or is not connected.'
                -
                  uuid: b67ed4a3ce5a49e4ac4079e258d7fe7c
                  expression: 'last(/APC UPS Symmetra RX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=2'
                  name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Warning'
                  priority: AVERAGE
                  description: 'The external sensor has returned a value greater than the warning threshold.'
            -
              uuid: 15e3cf28f89043029e722b1813737c6c
              name: '{#EXTERNAL_SENSOR2_NAME}: Temperature sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.2.6.1.1
              key: 'external.sensor.temperature[uioSensorStatusTemperatureDegC.2.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: ℃
              description: |
                MIB: PowerNet-MIB
                The sensor's current temperature reading in Celsius.
                 -1 indicates an invalid reading due to lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
          overrides:
            -
              name: Temp
              step: '1'
              filter:
                conditions:
                  -
                    macro: '{#EXTERNAL_SENSOR2_NAME}'
                    value: Temp
                    formulaid: A
              operations:
                -
                  operationobject: ITEM_PROTOTYPE
                  operator: LIKE
                  value: Humidity
                  status: ENABLED
                  discover: NO_DISCOVER
        -
          uuid: 88032aa9a832464ca2a077271113e7c9
          name: 'Input phases discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#PHASEINDEX},1.3.6.1.4.1.318.1.1.1.9.2.3.1.2.1.1]'
          key: input.phases.discovery
          delay: 1h
          description: 'The input phase identifier. OID upsPhaseInputPhaseIndex.1.1'
          item_prototypes:
            -
              uuid: d6afc20571ce43fa9861ef6c1e17d6c8
              name: '{#PHASEINDEX}: Phase input current'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.2.3.1.6.1.1.{#PHASEINDEX}'
              key: 'phase.input.current[upsPhaseInputCurrent.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: A
              description: |
                MIB: PowerNet-MIB
                The input current in 0.1 amperes, or -0.1 if it's
                 unsupported by this UPS.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.1'
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
            -
              uuid: 6993631adffb41fabc7995bd9158e448
              name: '{#PHASEINDEX}: Phase input voltage'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.2.3.1.3.1.1.{#PHASEINDEX}'
              key: 'phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: V
              description: |
                MIB: PowerNet-MIB
                The input voltage in VAC, or -1 if it's unsupported
                 by this UPS.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
              trigger_prototypes:
                -
                  uuid: 212cf86650fc4c189115da565111f5d3
                  expression: 'min(/APC UPS Symmetra RX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}'
                  name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})'
                  opdata: 'Current phase {#PHASEINDEX} voltage: {ITEM.LASTVALUE1}'
                  priority: HIGH
        -
          uuid: 262343758e9649a8a6fe2b77631f66df
          name: 'Output phases discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#PHASEINDEX},1.3.6.1.4.1.318.1.1.1.9.3.3.1.2.1.1]'
          key: output.phases.discovery
          delay: 1h
          description: 'The output phase identifier. OID upsPhaseOutputPhaseIndex.1.1'
          item_prototypes:
            -
              uuid: 6bed63601e6b426799b860dc5e2ea8b2
              name: '{#PHASEINDEX}: Phase output current'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.3.3.1.4.1.1.{#PHASEINDEX}'
              key: 'phase.output.current[upsPhaseOutputCurrent.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: A
              description: |
                MIB: PowerNet-MIB
                The output current in 0.1 amperes drawn
                 by the load on the UPS, or -1 if it's unsupported
                 by this UPS.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.1'
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
            -
              uuid: 5ec8aae1e2b24350b005d0177b164e6b
              name: '{#PHASEINDEX}: Phase output load, %'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.3.3.1.10.1.1.{#PHASEINDEX}'
              key: 'phase.output.load.percent[upsPhaseOutputPercentLoad.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: PowerNet-MIB
                The percentage of the UPS load capacity in VA at
                 redundancy @ (n + x) presently being used on this
                 output phase, or -1 if it's unsupported by this UPS.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
            -
              uuid: 3da95223adfc4d638406c6908bba7063
              name: '{#PHASEINDEX}: Phase output voltage'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.3.3.1.3.1.1.{#PHASEINDEX}'
              key: 'phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: V
              description: |
                MIB: PowerNet-MIB
                The output voltage in VAC, or -1 if it's unsupported
                 by this UPS.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: Status
              trigger_prototypes:
                -
                  uuid: 47069f8d431f45d490674d7ba01d2bb2
                  expression: 'min(/APC UPS Symmetra RX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra RX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}'
                  name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})'
                  opdata: 'Current phase {#PHASEINDEX} voltage: {ITEM.LASTVALUE1}'
                  priority: HIGH
      macros:
        -
          macro: '{$BATTERY.CAPACITY.MIN.WARN}'
          value: '50'
          description: 'Minimum battery capacity percentage for trigger expression.'
        -
          macro: '{$BATTERY.TEMP.MAX.WARN}'
          value: '55'
          description: 'Maximum battery temperature for trigger expression.'
        -
          macro: '{$SNMP.TIMEOUT}'
          value: 5m
          description: 'The time interval for SNMP agent availability trigger expression.'
        -
          macro: '{$TIME.PERIOD}'
          value: 15m
          description: 'Time period for trigger expression.'
        -
          macro: '{$UPS.INPUT_FREQ.MAX.WARN}'
          value: '50.3'
          description: 'Maximum input frequency for trigger expression.'
        -
          macro: '{$UPS.INPUT_FREQ.MIN.WARN}'
          value: '49.7'
          description: 'Minimum input frequency for trigger expression.'
        -
          macro: '{$UPS.INPUT_VOLT.MAX.WARN}'
          value: '243'
          description: 'Maximum input voltage for trigger expression.'
        -
          macro: '{$UPS.INPUT_VOLT.MIN.WARN}'
          value: '197'
          description: 'Minimum input voltage for trigger expression.'
        -
          macro: '{$UPS.OUTPUT.MAX.WARN}'
          value: '80'
          description: 'Maximum output load in % for trigger expression.'
      valuemaps:
        -
          uuid: e2877a188bd24918992f8c7878550924
          name: 'PowerNet-MIB::uioSensorStatusAlarmStatus'
          mappings:
            -
              value: '1'
              newvalue: Normal
            -
              value: '2'
              newvalue: Warning
            -
              value: '3'
              newvalue: Critical
            -
              value: '4'
              newvalue: 'Not applicable'
        -
          uuid: 33d83523ceee4f3e916c885ebb33e8b9
          name: 'PowerNet-MIB::upsAdvBatteryReplaceIndicator'
          mappings:
            -
              value: '1'
              newvalue: 'no Battery Needs Replacing'
            -
              value: '2'
              newvalue: 'battery Needs Replacing'
        -
          uuid: c50ef9a9476d47e6935a6026bbb24d06
          name: 'PowerNet-MIB::upsAdvInputLineFailCause'
          mappings:
            -
              value: '1'
              newvalue: 'no Transfer'
            -
              value: '2'
              newvalue: 'High Line Voltage'
            -
              value: '3'
              newvalue: Brownout
            -
              value: '4'
              newvalue: Blackout
            -
              value: '5'
              newvalue: 'Small Momentary Sag'
            -
              value: '6'
              newvalue: 'Deep Momentary Sag'
            -
              value: '7'
              newvalue: 'Small Momentary Spike'
            -
              value: '8'
              newvalue: 'Large Momentary Spike'
            -
              value: '9'
              newvalue: 'Self Test'
            -
              value: '10'
              newvalue: 'Rate of Voltage Change'
        -
          uuid: 96a985d8351f48be86c5b00472b48feb
          name: 'PowerNet-MIB::upsBasicBatteryStatus'
          mappings:
            -
              value: '1'
              newvalue: Unknown
            -
              value: '2'
              newvalue: Normal
            -
              value: '3'
              newvalue: Low
            -
              value: '4'
              newvalue: 'In Fault Condition'
        -
          uuid: 160f7a39770d492c93403097650c1568
          name: 'PowerNet-MIB::upsBasicOutputStatus'
          mappings:
            -
              value: '1'
              newvalue: Unknown
            -
              value: '2'
              newvalue: Online
            -
              value: '3'
              newvalue: 'On Battery'
            -
              value: '4'
              newvalue: 'On Smart Boost'
            -
              value: '5'
              newvalue: 'Timed Sleeping'
            -
              value: '6'
              newvalue: 'Software Bypass'
            -
              value: '7'
              newvalue: 'Off'
            -
              value: '8'
              newvalue: Rebooting
            -
              value: '9'
              newvalue: 'Switched Bypass'
            -
              value: '10'
              newvalue: 'Hardware Failure Bypass'
            -
              value: '11'
              newvalue: 'Sleeping Until Power Return'
            -
              value: '12'
              newvalue: 'On Smart Trim'
            -
              value: '13'
              newvalue: 'Eco Mode'
            -
              value: '14'
              newvalue: 'Hot Standby'
            -
              value: '15'
              newvalue: 'On Battery Test'
            -
              value: '16'
              newvalue: 'Emergency Static Bypass'
            -
              value: '17'
              newvalue: 'Static Bypass Standby'
            -
              value: '18'
              newvalue: 'Power Saving Mode'
            -
              value: '19'
              newvalue: 'Spot Mode'
            -
              value: '20'
              newvalue: E-Conversion
            -
              value: '21'
              newvalue: 'Charger Spotmode'
            -
              value: '22'
              newvalue: 'Inverter Spotmode'
            -
              value: '23'
              newvalue: 'Active Load'
            -
              value: '24'
              newvalue: 'Battery Discharge Spotmode'
            -
              value: '25'
              newvalue: 'Inverter Standby'
            -
              value: '26'
              newvalue: 'Charger Only'
        -
          uuid: cc7a368057bc47eeb834dc9363183c59
          name: zabbix.host.available
          mappings:
            -
              value: '0'
              newvalue: 'not available'
            -
              value: '1'
              newvalue: available
            -
              value: '2'
              newvalue: unknown
  graphs:
    -
      uuid: 69ef37f00b0249bb98f381b483280dd1
      name: 'Capacity of the UPS batteries'
      type: PIE
      graph_items:
        -
          color: 1A7C11
          item:
            host: 'APC UPS Symmetra RX SNMP'
            key: 'battery.capacity[upsHighPrecBatteryCapacity]'
    -
      uuid: 782c8a349b7f4f93a65aeaa058454b14
      name: Output
      graph_items:
        -
          color: 1A7C11
          item:
            host: 'APC UPS Symmetra RX SNMP'
            key: 'output.current[upsHighPrecOutputCurrent]'
        -
          sortorder: '1'
          color: 2774A4
          item:
            host: 'APC UPS Symmetra RX SNMP'
            key: 'output.load[upsHighPrecOutputLoad]'
    -
      uuid: 8bc9d8e4bb284134b67498daccb85d5e
      name: Voltage
      graph_items:
        -
          color: 1A7C11
          item:
            host: 'APC UPS Symmetra RX SNMP'
            key: 'input.voltage[upsHighPrecInputLineVoltage]'
        -
          sortorder: '1'
          color: 2774A4
          item:
            host: 'APC UPS Symmetra RX SNMP'
            key: 'output.voltage[upsHighPrecOutputVoltage]'