diff options
author | Bastien Montagne <montagne29@wanadoo.fr> | 2014-08-26 14:04:24 +0400 |
---|---|---|
committer | Bastien Montagne <montagne29@wanadoo.fr> | 2014-08-26 14:31:08 +0400 |
commit | 0e3fa0b7618fa86e97c5f46ae7208c082fd26eb7 (patch) | |
tree | 447fcae65fe6bf4086a79e03a82abb7a4138897b /source/blender/editors/mesh/editmesh_inset.c | |
parent | 600248783b50ddef9b809b0d4c7abd9a9b20fda3 (diff) |
Fix T41590: When scene scale is not 1.0, and units are "None," Blender assumes translations are in meters.
Turned out there were several issues in handling of scale parameter by numinput.
Fixed that by factorizing more some code in common with 'usual' numbuttons eval code
(new `bUnit_getScaleUnit()` helper will return valid scaled value, depending on
given system and type).
Now, numinput behaves as expected - using default unit amended by scale in case no unit is given
(i.e. entering '20' with a scale of 0.01 will give you 20cm, and '20cm' as well!).
Diffstat (limited to 'source/blender/editors/mesh/editmesh_inset.c')
-rw-r--r-- | source/blender/editors/mesh/editmesh_inset.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/source/blender/editors/mesh/editmesh_inset.c b/source/blender/editors/mesh/editmesh_inset.c index 4a552d0fbd3..a4942d01671 100644 --- a/source/blender/editors/mesh/editmesh_inset.c +++ b/source/blender/editors/mesh/editmesh_inset.c @@ -90,7 +90,7 @@ static void edbm_inset_update_header(wmOperator *op, bContext *C) if (sa) { char flts_str[NUM_STR_REP_LEN * 2]; if (hasNumInput(&opdata->num_input)) - outputNumInput(&opdata->num_input, flts_str, sce->unit.scale_length); + outputNumInput(&opdata->num_input, flts_str, &sce->unit); else { BLI_snprintf(flts_str, NUM_STR_REP_LEN, "%f", RNA_float_get(op->ptr, "thickness")); BLI_snprintf(flts_str + NUM_STR_REP_LEN, NUM_STR_REP_LEN, "%f", RNA_float_get(op->ptr, "depth")); |