SCA_ISensor(SCA_ILogicBrick)
============================
.. module:: bge.types
base class --- :class:`SCA_ILogicBrick`
.. class:: SCA_ISensor(SCA_ILogicBrick)
Base class for all sensor logic bricks.
.. attribute:: usePosPulseMode
Flag to turn positive pulse mode on and off.
:type: boolean
.. attribute:: useNegPulseMode
Flag to turn negative pulse mode on and off.
:type: boolean
.. attribute:: frequency
The frequency for pulse mode sensors. (Deprecated: use SCA_ISensor.skippedTicks)
:type: integer
.. attribute:: skippedTicks
Number of logic ticks skipped between 2 active pulses
:type: integer
.. attribute:: level
level Option whether to detect level or edge transition when entering a state.
It makes a difference only in case of logic state transition (state actuator).
A level detector will immediately generate a pulse, negative or positive
depending on the sensor condition, as soon as the state is activated.
A edge detector will wait for a state change before generating a pulse.
note: mutually exclusive with :data:`tap`, enabling will disable :data:`tap`.
:type: boolean
.. attribute:: tap
When enabled only sensors that are just activated will send a positive event,
after this they will be detected as negative by the controllers.
This will make a key thats held act as if its only tapped for an instant.
note: mutually exclusive with :data:`level`, enabling will disable :data:`level`.
:type: boolean
.. attribute:: invert
Flag to set if this sensor activates on positive or negative events.
:type: boolean
.. attribute:: triggered
True if this sensor brick is in a positive state. (read-only).
:type: boolean
.. attribute:: positive
True if this sensor brick is in a positive state. (read-only).
:type: boolean
.. attribute:: pos_ticks
The number of ticks since the last positive pulse (read-only).
:type: int
.. attribute:: neg_ticks
The number of ticks since the last negative pulse (read-only).
:type: int
.. attribute:: status
The status of the sensor (read-only): can be one of :ref:`these constants<sensor-status>`.
:type: int
.. note::
This convenient attribute combines the values of triggered and positive attributes.
.. method:: reset()
Reset sensor internal state, effect depends on the type of sensor and settings.
The sensor is put in its initial state as if it was just activated.
|