diff options
Diffstat (limited to 'Middlewares/ST/STM32_WPAN/Release_Notes.html')
-rw-r--r-- | Middlewares/ST/STM32_WPAN/Release_Notes.html | 301 |
1 files changed, 290 insertions, 11 deletions
diff --git a/Middlewares/ST/STM32_WPAN/Release_Notes.html b/Middlewares/ST/STM32_WPAN/Release_Notes.html index 6504ed2d7..3444edc4a 100644 --- a/Middlewares/ST/STM32_WPAN/Release_Notes.html +++ b/Middlewares/ST/STM32_WPAN/Release_Notes.html @@ -11,7 +11,7 @@ span.underline{text-decoration: underline;} div.column{display: inline-block; vertical-align: top; width: 50%;} </style> - <link rel="stylesheet" href="./_htmresc/mini-st.css" /> + <link rel="stylesheet" href="_htmresc/mini-st.css" /> <!--[if lt IE 9]> <script src="//cdnjs.cloudflare.com/ajax/libs/html5shiv/3.7.3/html5shiv-printshiv.min.js"></script> <![endif]--> @@ -42,16 +42,295 @@ <li><p>Zigbee Applications</p></li> </ul> <p><strong>NOTE</strong> : Depending on the kind of Application targeted, the appropriate Wireless Coprocessor Firmware needs to be loaded.</p> -<p>All available binaries are located under/Projects/STM32_Copro_Wireless_Binaries directory.</p> -<p>Refer to UM2237 to learn how to use/install STM32CubeProgrammer.</p> -<p>Refer to /Projects/STM32_Copro_Wireless_Binaries/ReleaseNote.html for the detailed procedure to change the Coprocessor binary.</p> +<ul> +<li><strong>Zigbee</strong> clusters are provided as a library. +<ul> +<li>Available on <strong>IAR/SW4STM32</strong>(<strong>stm32wb_zigbee_wb_lib.a</strong>) and <strong>Keil</strong>(<strong>stm32wb_zigbee_wb_lib_keil.lib</strong>) under Middlewares/ST/STM32_WPAN/zigbee/lib.</li> +<li>To get access to Zigbee clusters source code, please contact ST local office.</li> +</ul></li> +<li><p>All available binaries are located under/Projects/STM32_Copro_Wireless_Binaries directory.</p></li> +<li><p>Refer to UM2237 to learn how to use/install STM32CubeProgrammer.</p></li> +<li>Refer to /Projects/STM32_Copro_Wireless_Binaries/ReleaseNote.html for the detailed procedure to change the Coprocessor binary.</li> +</ul> </div> <div class="col-sm-12 col-lg-8"> <h1 id="update-history">Update History</h1> <div class="collapse"> -<input type="checkbox" id="collapse-section7" checked aria-hidden="true"> <label for="collapse-section7" aria-hidden="false">V1.5.0 / 22-January-2020</label> +<input type="checkbox" id="collapse-section8" checked aria-hidden="true"> <label for="collapse-section8" aria-hidden="false">V1.6.0 / 27-March-2020</label> <div> <h2 id="main-changes">Main Changes</h2> +<p>BLE-Mesh:</p> +<ul> +<li>BLE-Mesh library version 1.12.007 +<ul> +<li>Updated for Delta level set binding to Light lightness</li> +<li>Multi Key updates.</li> +<li>Correction of FSM issues in the LC Model: no way to consume a packet internally.</li> +<li>Correction of Sensor_LC_Light_Publish sending wrong property (and LC Model handling wrong property).</li> +<li>Updates on Generic Models for Certification tests: Generic OnOff, Level, Power OnOff, Transition Time<br /> +</li> +<li>Update Multi elements support</li> +<li>Changes for DYNAMIC_PROVISIONER in Provisioner project</li> +</ul></li> +<li>New Cryptographic library v3.1.3</li> +</ul> +<p>Zigbee:</p> +<ul> +<li>Libarry available on IAR/SW4STM32(stm32wb_zigbee_wb_lib.a) and Keil(stm32wb_zigbee_wb_lib_keil.lib)</li> +<li>Support following list (47 clusters):</li> +</ul> +<table> +<thead> +<tr class="header"> +<th>Cluster Number</th> +<th>Cluster ID</th> +<th style="text-align: left;">Cluster Name</th> +</tr> +</thead> +<tbody> +<tr class="odd"> +<td>1</td> +<td>0x0000</td> +<td style="text-align: left;">Basic</td> +</tr> +<tr class="even"> +<td>2</td> +<td>0x0001</td> +<td style="text-align: left;">Power Configuration</td> +</tr> +<tr class="odd"> +<td>3</td> +<td>0x0003</td> +<td style="text-align: left;">Identify6</td> +</tr> +<tr class="even"> +<td>4</td> +<td>0x0004</td> +<td style="text-align: left;">Groups</td> +</tr> +<tr class="odd"> +<td>5</td> +<td>0x0005</td> +<td style="text-align: left;">Scenes</td> +</tr> +<tr class="even"> +<td>6</td> +<td>0x0006</td> +<td style="text-align: left;">On/Off</td> +</tr> +<tr class="odd"> +<td>7</td> +<td>0x0008</td> +<td style="text-align: left;">Level Control</td> +</tr> +<tr class="even"> +<td>8</td> +<td>0x000a</td> +<td style="text-align: left;">Time</td> +</tr> +<tr class="odd"> +<td>9</td> +<td>0x0019</td> +<td style="text-align: left;">OTA Upgrade</td> +</tr> +<tr class="even"> +<td>10</td> +<td>0x0020</td> +<td style="text-align: left;">Poll Control</td> +</tr> +<tr class="odd"> +<td>11</td> +<td>0x0021</td> +<td style="text-align: left;">Green Power Proxy</td> +</tr> +<tr class="even"> +<td>12</td> +<td>0x0102</td> +<td style="text-align: left;">Window Covering</td> +</tr> +<tr class="odd"> +<td>13</td> +<td>0x0202</td> +<td style="text-align: left;">Fan Control</td> +</tr> +<tr class="even"> +<td>14</td> +<td>0x0204</td> +<td style="text-align: left;">Thermostat User Interface Configuration</td> +</tr> +<tr class="odd"> +<td>15</td> +<td>0x0300</td> +<td style="text-align: left;">Color control</td> +</tr> +<tr class="even"> +<td>16</td> +<td>0x0301</td> +<td style="text-align: left;">Ballast Configuration</td> +</tr> +<tr class="odd"> +<td>17</td> +<td>0x0400</td> +<td style="text-align: left;">Illuminance Measurement</td> +</tr> +<tr class="even"> +<td>18</td> +<td>0x0402</td> +<td style="text-align: left;">Temperature Measurement</td> +</tr> +<tr class="odd"> +<td>19</td> +<td>0x0406</td> +<td style="text-align: left;">Occupancy Sensing</td> +</tr> +<tr class="even"> +<td>20</td> +<td>0x0502</td> +<td style="text-align: left;">IAS Warning Device (WD)</td> +</tr> +<tr class="odd"> +<td>21</td> +<td>0x0b05</td> +<td style="text-align: left;">Diagnostics</td> +</tr> +<tr class="even"> +<td>22</td> +<td>0x1000</td> +<td style="text-align: left;">Touchlink</td> +</tr> +<tr class="odd"> +<td>23</td> +<td>0x0002</td> +<td style="text-align: left;">Device Temperature Configuration</td> +</tr> +<tr class="even"> +<td>24</td> +<td>0x0007</td> +<td style="text-align: left;">On/Off Switch Configuration</td> +</tr> +<tr class="odd"> +<td>25</td> +<td>0x0009</td> +<td style="text-align: left;">Alarms</td> +</tr> +<tr class="even"> +<td>26</td> +<td>0x000b</td> +<td style="text-align: left;">RSSI Location</td> +</tr> +<tr class="odd"> +<td>27</td> +<td>0x0015</td> +<td style="text-align: left;">Commissioning</td> +</tr> +<tr class="even"> +<td>28</td> +<td>0x001a</td> +<td style="text-align: left;">Power Profile Cluster</td> +</tr> +<tr class="odd"> +<td>29</td> +<td>0x0024</td> +<td style="text-align: left;">Nearest Gateway Cluster</td> +</tr> +<tr class="even"> +<td>30</td> +<td>0x0101</td> +<td style="text-align: left;">Door Lock</td> +</tr> +<tr class="odd"> +<td>31</td> +<td>0x0200</td> +<td style="text-align: left;">Pump Configuration and Control</td> +</tr> +<tr class="even"> +<td>32</td> +<td>0x0201</td> +<td style="text-align: left;">Thermostat</td> +</tr> +<tr class="odd"> +<td>33</td> +<td>0x0203</td> +<td style="text-align: left;">Dehumidification Control</td> +</tr> +<tr class="even"> +<td>34</td> +<td>0x0401</td> +<td style="text-align: left;">Illuminance Level Sensing</td> +</tr> +<tr class="odd"> +<td>35</td> +<td>0x0403</td> +<td style="text-align: left;">Pressure Measurement</td> +</tr> +<tr class="even"> +<td>36</td> +<td>0x0405</td> +<td style="text-align: left;">Relative Humidity Measurement</td> +</tr> +<tr class="odd"> +<td>37</td> +<td>0x0500</td> +<td style="text-align: left;">IAS Zone</td> +</tr> +<tr class="even"> +<td>38</td> +<td>0x0501</td> +<td style="text-align: left;">IAS Ancillary Control Equipment (ACE)</td> +</tr> +<tr class="odd"> +<td>39</td> +<td>0x0700</td> +<td style="text-align: left;">Price</td> +</tr> +<tr class="even"> +<td>40</td> +<td>0x0701</td> +<td style="text-align: left;">Demand Response and Load Control</td> +</tr> +<tr class="odd"> +<td>41</td> +<td>0x0702</td> +<td style="text-align: left;">Metering</td> +</tr> +<tr class="even"> +<td>42</td> +<td>0x0703</td> +<td style="text-align: left;">Messaging</td> +</tr> +<tr class="odd"> +<td>43</td> +<td>0x0704</td> +<td style="text-align: left;">Smart Energy Tunneling (Complex Metering)</td> +</tr> +<tr class="even"> +<td>44</td> +<td>0x0800</td> +<td style="text-align: left;">Key Establishment</td> +</tr> +<tr class="odd"> +<td>45</td> +<td>0x0904</td> +<td style="text-align: left;">Voice Over ZigBee</td> +</tr> +<tr class="even"> +<td>46</td> +<td>0x0b01</td> +<td style="text-align: left;">Meter Identification</td> +</tr> +<tr class="odd"> +<td>47</td> +<td>0x0b04</td> +<td style="text-align: left;">Electrical Measurement</td> +</tr> +</tbody> +</table> +</div> +</div> +<div class="collapse"> +<input type="checkbox" id="collapse-section7" aria-hidden="true"> <label for="collapse-section7" aria-hidden="false">V1.5.0 / 22-January-2020</label> +<div> +<h2 id="main-changes-1">Main Changes</h2> <p>Interface:</p> <ul> <li>Added new commmand SHCI_C2_SetFlashActivityControl() to configure BLE timing protection</li> @@ -94,7 +373,7 @@ <div class="collapse"> <input type="checkbox" id="collapse-section6" aria-hidden="true"> <label for="collapse-section6" aria-hidden="true">V1.4.0 / 22-November-2019</label> <div> -<h2 id="main-changes-1">Main Changes</h2> +<h2 id="main-changes-2">Main Changes</h2> <p>Interface:</p> <ul> <li>Added new commmand SHCI_C2_ExtpaConfig() to support external PA</li> @@ -110,7 +389,7 @@ <div class="collapse"> <input type="checkbox" id="collapse-section5" aria-hidden="true"> <label for="collapse-section5" aria-hidden="true">V1.3.0 / 4-September-2019</label> <div> -<h2 id="main-changes-2">Main Changes</h2> +<h2 id="main-changes-3">Main Changes</h2> <p>General:</p> <ul> <li>Introducing support of Zigbee</li> @@ -148,7 +427,7 @@ <div class="collapse"> <input type="checkbox" id="collapse-section4" aria-hidden="true"> <label for="collapse-section4" aria-hidden="true">V1.2.0 / 27-June-2019</label> <div> -<h2 id="main-changes-3">Main Changes</h2> +<h2 id="main-changes-4">Main Changes</h2> <p>General:</p> <ul> <li>Following utilities : Scheduler and Low Power Manager reworked and moved to “Utilities” directory</li> @@ -174,7 +453,7 @@ <div class="collapse"> <input type="checkbox" id="collapse-section3" aria-hidden="true"> <label for="collapse-section3" aria-hidden="true">V1.1.1 / 10-May-2019</label> <div> -<h2 id="main-changes-4">Main Changes</h2> +<h2 id="main-changes-5">Main Changes</h2> <p>BLE:</p> <ul> <li>Fix race condition in transport layer when an operating system is used.</li> @@ -220,7 +499,7 @@ <div class="collapse"> <input type="checkbox" id="collapse-section2" aria-hidden="true"> <label for="collapse-section2" aria-hidden="true">V1.1.0 / 29-March-2019</label> <div> -<h2 id="main-changes-5">Main Changes</h2> +<h2 id="main-changes-6">Main Changes</h2> <p>General:</p> <ul> <li>Licenses in utilities and patterns moved from sla0044 to 3-clauses BSD</li> @@ -246,7 +525,7 @@ <div class="collapse"> <input type="checkbox" id="collapse-section1" aria-hidden="true"> <label for="collapse-section1" aria-hidden="true">V1.0.0 / 31-January-2019</label> <div> -<h2 id="main-changes-6">Main Changes</h2> +<h2 id="main-changes-7">Main Changes</h2> <p>First release</p> </div> </div> |