diff options
author | Joerg Steffens <joerg.steffens@bareos.com> | 2017-10-09 17:53:08 +0300 |
---|---|---|
committer | Joerg Steffens <joerg.steffens@bareos.com> | 2017-10-09 17:53:08 +0300 |
commit | b92a4fb25b67f08f3bb39392247356a9d59c868e (patch) | |
tree | 9608b0a5fb823354e2b4e03d5bf399a6898390cc | |
parent | 25e58f4f9a0ce3cdc078dd81d8a4281b74c29951 (diff) |
added release notes to bareos-16.2.7
-rw-r--r-- | manuals/en/main/releasenotes.tex | 25 |
1 files changed, 24 insertions, 1 deletions
diff --git a/manuals/en/main/releasenotes.tex b/manuals/en/main/releasenotes.tex index 18fd407..324c98f 100644 --- a/manuals/en/main/releasenotes.tex +++ b/manuals/en/main/releasenotes.tex @@ -16,6 +16,29 @@ This chapter concentrates on things to do when updating an existing Bareos insta \section*{Bareos-16.2} +\releasenote{16.2.7}{ + +\begin{tabular}{p{0.2\textwidth} p{0.8\textwidth}} +Code Release & 2017-10-09\\ +Database Version & 2004 (unchanged)\\ +Release Ticket & \ticket{836}\\ +Url & \releaseUrlDownloadBareosCom{16.2} \\ +\end{tabular} + +This release contains several bugfixes and enhancements. Excerpt: +\begin{itemize} + \item Fixes a Director crash, when enabling debugging output + \item \bcommand{.bvfs_lsdirs}{}: improve performance, especially when having a large number of directories + \item Utilize OpenSSL $\geq$ 1.1 if available + \item Windows: fixes silent upgrade (\command{winbareos-*.exe /S}) + \item Windows: restore attributes also on directories (not only on files) + \item Fixes problem with SHA1 signature when compiled without OpenSSL (not relevant for bareos.org/bareos.com packages) + \item Packages for openSUSE Leap 42.3 have been added. +\end{itemize} + +} + + \releasenote{16.2.6}{ \begin{tabular}{p{0.2\textwidth} p{0.8\textwidth}} @@ -33,7 +56,7 @@ This release contains several bugfixes and enhancements. Excerpt: \item New directive \configdirective{LanAddress} was added to the Client and Storage Resources of the director to facilitate a network topology where client and storage are situated inside of a LAN, but the Director is outside of that LAN. See \nameref{LanAddress} for details. \item A Problem in the storage abstraction layer was fixed where the director picked the wrong storage daemon when multiple storages/storage daemons were used. \item The device spool size calculation when using secure erase was fixed. - \item \bcommand{.bvfs_lsdirs} no longer shows empty directories from accurate jobs. + \item \bcommand{.bvfs_lsdirs}{} no longer shows empty directories from accurate jobs. \begin{itemize} \item \warning{This decreases performance if your environment has a large numbers of directories. Creating an index improves the performance.} %In Bareos 16.2.6 the SQL Query used by \bcommand{.bvfs_lsdirs}{} was changed to not show |