Welcome to mirror list, hosted at ThFree Co, Russian Federation.

github.com/torvalds/linux.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorMark Pearson <markpearson@lenovo.com>2022-02-22 21:51:37 +0300
committerHans de Goede <hdegoede@redhat.com>2022-03-02 13:42:36 +0300
commitbf779aaf56ea23864e39e9862b3b3a8436236e07 (patch)
tree2bdf5faa1597698d89c68f979eb32a3db400ffad /drivers/platform
parent402576d9804e9dc9b31af4e3613aa8da9ebce84e (diff)
platform/x86: thinkpad_acpi: Add dual fan probe
Instead of having quirks for systems that have a second fan it would be nice to detect this setup. Unfortunately, confirmed by the Lenovo FW team, there is no way to retrieve this information from the EC or BIOS. Recommendation was to attempt to read the fan and if successful then assume a 2nd fan is present. The fans are also supposed to spin up on boot for some time, so in theory we could check for a speed > 0. In testing this seems to hold true but as I couldn't test on all platforms I've avoided implementing this. It also breaks for the corner case where you load the module once the fans are idle. Tested on P1G4, P1G3, X1C9 and T14 (no fans) and it works correctly. For the platforms with dual fans where it was confirmed to work I have removed the quirks. Potentially this could be done for all platforms but I've left untested platforms in for now. On these platforms the fans will be enabled and then detected - so no impact. Signed-off-by: Mark Pearson <markpearson@lenovo.com> Link: https://lore.kernel.org/r/20220222185137.4325-1-markpearson@lenovo.com Reviewed-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Diffstat (limited to 'drivers/platform')
-rw-r--r--drivers/platform/x86/thinkpad_acpi.c15
1 files changed, 12 insertions, 3 deletions
diff --git a/drivers/platform/x86/thinkpad_acpi.c b/drivers/platform/x86/thinkpad_acpi.c
index e9b1574729b9..d0599e8a7b4d 100644
--- a/drivers/platform/x86/thinkpad_acpi.c
+++ b/drivers/platform/x86/thinkpad_acpi.c
@@ -8698,10 +8698,7 @@ static const struct tpacpi_quirk fan_quirk_table[] __initconst = {
TPACPI_Q_LNV3('N', '2', 'N', TPACPI_FAN_2CTL), /* P53 / P73 */
TPACPI_Q_LNV3('N', '2', 'E', TPACPI_FAN_2CTL), /* P1 / X1 Extreme (1st gen) */
TPACPI_Q_LNV3('N', '2', 'O', TPACPI_FAN_2CTL), /* P1 / X1 Extreme (2nd gen) */
- TPACPI_Q_LNV3('N', '2', 'V', TPACPI_FAN_2CTL), /* P1 / X1 Extreme (3nd gen) */
- TPACPI_Q_LNV3('N', '4', '0', TPACPI_FAN_2CTL), /* P1 / X1 Extreme (4nd gen) */
TPACPI_Q_LNV3('N', '3', '0', TPACPI_FAN_2CTL), /* P15 (1st gen) / P15v (1st gen) */
- TPACPI_Q_LNV3('N', '3', '2', TPACPI_FAN_2CTL), /* X1 Carbon (9th gen) */
TPACPI_Q_LNV3('N', '3', '7', TPACPI_FAN_2CTL), /* T15g (2nd gen) */
TPACPI_Q_LNV3('N', '1', 'O', TPACPI_FAN_NOFAN), /* X1 Tablet (2nd gen) */
};
@@ -8745,6 +8742,9 @@ static int __init fan_init(struct ibm_init_struct *iibm)
* ThinkPad ECs supports the fan control register */
if (likely(acpi_ec_read(fan_status_offset,
&fan_control_initial_status))) {
+ int res;
+ unsigned int speed;
+
fan_status_access_mode = TPACPI_FAN_RD_TPEC;
if (quirks & TPACPI_FAN_Q1)
fan_quirk1_setup();
@@ -8757,6 +8757,15 @@ static int __init fan_init(struct ibm_init_struct *iibm)
tp_features.second_fan_ctl = 1;
pr_info("secondary fan control enabled\n");
}
+ /* Try and probe the 2nd fan */
+ res = fan2_get_speed(&speed);
+ if (res >= 0) {
+ /* It responded - so let's assume it's there */
+ tp_features.second_fan = 1;
+ tp_features.second_fan_ctl = 1;
+ pr_info("secondary fan control detected & enabled\n");
+ }
+
} else {
pr_err("ThinkPad ACPI EC access misbehaving, fan status and control unavailable\n");
return -ENODEV;