diff options
Diffstat (limited to 'templates/net/brocade_fc_sw_snmp/template_net_brocade_fc_sw_snmp.yaml')
-rw-r--r-- | templates/net/brocade_fc_sw_snmp/template_net_brocade_fc_sw_snmp.yaml | 144 |
1 files changed, 72 insertions, 72 deletions
diff --git a/templates/net/brocade_fc_sw_snmp/template_net_brocade_fc_sw_snmp.yaml b/templates/net/brocade_fc_sw_snmp/template_net_brocade_fc_sw_snmp.yaml index c987be4c97a..70236f55fa8 100644 --- a/templates/net/brocade_fc_sw_snmp/template_net_brocade_fc_sw_snmp.yaml +++ b/templates/net/brocade_fc_sw_snmp/template_net_brocade_fc_sw_snmp.yaml @@ -1,6 +1,6 @@ zabbix_export: version: '6.4' - date: '2022-08-16T11:01:17Z' + date: '2022-10-27T14:44:41Z' template_groups: - uuid: 36bff6c29af64692839d077febfc7079 @@ -8,8 +8,8 @@ zabbix_export: templates: - uuid: de96d02bd5f242bfa31308ae2131d03f - template: 'Brocade FC SNMP' - name: 'Brocade FC SNMP' + template: 'Brocade FC by SNMP' + name: 'Brocade FC by SNMP' description: | Template Net Brocade FC @@ -48,7 +48,7 @@ zabbix_export: triggers: - uuid: 0c73f37e7ffc4acf83a7edeb84398aba - expression: 'max(/Brocade FC SNMP/icmpping,#3)=0' + expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0' name: 'Unavailable by ICMP ping' priority: HIGH description: 'Last three attempts returned timeout. Please check device connectivity.' @@ -74,14 +74,14 @@ zabbix_export: triggers: - uuid: eea2256c85764c12b1da83dd8d1a9fe3 - expression: 'min(/Brocade FC SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade FC SNMP/icmppingloss,5m)<100' + expression: 'min(/Brocade FC by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade FC by SNMP/icmppingloss,5m)<100' name: 'High ICMP ping loss' opdata: 'Loss: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Unavailable by ICMP ping' - expression: 'max(/Brocade FC SNMP/icmpping,#3)=0' + expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0' tags: - tag: scope @@ -107,17 +107,17 @@ zabbix_export: triggers: - uuid: 17df26093a5f42fdb19715371c85f733 - expression: 'avg(/Brocade FC SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' + expression: 'avg(/Brocade FC by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' name: 'High ICMP ping response time' opdata: 'Value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'High ICMP ping loss' - expression: 'min(/Brocade FC SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade FC SNMP/icmppingloss,5m)<100' + expression: 'min(/Brocade FC by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade FC by SNMP/icmppingloss,5m)<100' - name: 'Unavailable by ICMP ping' - expression: 'max(/Brocade FC SNMP/icmpping,#3)=0' + expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0' tags: - tag: scope @@ -181,7 +181,7 @@ zabbix_export: triggers: - uuid: 68a50684095941cb90f22fbc8d632e7a - expression: 'min(/Brocade FC SNMP/system.cpu.util[swCpuUsage.0],5m)>{$CPU.UTIL.CRIT}' + expression: 'min(/Brocade FC by SNMP/system.cpu.util[swCpuUsage.0],5m)>{$CPU.UTIL.CRIT}' name: 'High CPU utilization' event_name: 'High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)' opdata: 'Current utilization: {ITEM.LASTVALUE1}' @@ -238,7 +238,7 @@ zabbix_export: triggers: - uuid: 9c5ae10dbafb45658f25f0279a8a1934 - expression: 'last(/Brocade FC SNMP/system.hw.firmware,#1)<>last(/Brocade FC SNMP/system.hw.firmware,#2) and length(last(/Brocade FC SNMP/system.hw.firmware))>0' + expression: 'last(/Brocade FC by SNMP/system.hw.firmware,#1)<>last(/Brocade FC by SNMP/system.hw.firmware,#2) and length(last(/Brocade FC by SNMP/system.hw.firmware))>0' name: 'Firmware has changed' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: INFO @@ -272,7 +272,7 @@ zabbix_export: triggers: - uuid: 9939f98da99c435a9b5505e55e8abb5f - expression: 'last(/Brocade FC SNMP/system.hw.serialnumber,#1)<>last(/Brocade FC SNMP/system.hw.serialnumber,#2) and length(last(/Brocade FC SNMP/system.hw.serialnumber))>0' + expression: 'last(/Brocade FC by SNMP/system.hw.serialnumber,#1)<>last(/Brocade FC by SNMP/system.hw.serialnumber,#2) and length(last(/Brocade FC by SNMP/system.hw.serialnumber))>0' name: 'Device has been replaced' event_name: 'Device has been replaced (new serial number received)' priority: INFO @@ -359,7 +359,7 @@ zabbix_export: triggers: - uuid: 0e624c73fdca490e809ffe9235cda610 - expression: 'last(/Brocade FC SNMP/system.name,#1)<>last(/Brocade FC SNMP/system.name,#2) and length(last(/Brocade FC SNMP/system.name))>0' + expression: 'last(/Brocade FC by SNMP/system.name,#1)<>last(/Brocade FC by SNMP/system.name,#2) and length(last(/Brocade FC by SNMP/system.name))>0' name: 'System name has changed' event_name: 'System name has changed (new name: {ITEM.VALUE})' priority: INFO @@ -441,7 +441,7 @@ zabbix_export: triggers: - uuid: b91af8b94e2047538376be9911beadee - expression: 'count(/Brocade FC SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1' + expression: 'count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1' name: 'System status is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH @@ -455,7 +455,7 @@ zabbix_export: value: performance - uuid: b17d4a2bae804c968984b763fa4562fc - expression: 'count(/Brocade FC SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"offline\"}")=1 or count(/Brocade FC SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"testing\"}")=1' + expression: 'count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"offline\"}")=1 or count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"testing\"}")=1' name: 'System status is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING @@ -463,7 +463,7 @@ zabbix_export: dependencies: - name: 'System status is in critical state' - expression: 'count(/Brocade FC SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1' + expression: 'count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1' tags: - tag: scope @@ -490,7 +490,7 @@ zabbix_export: triggers: - uuid: 1991ae08b008488380db02160b15160e - expression: 'min(/Brocade FC SNMP/vm.memory.util[swMemUsage.0],5m)>{$MEMORY.UTIL.MAX}' + expression: 'min(/Brocade FC by SNMP/vm.memory.util[swMemUsage.0],5m)>{$MEMORY.UTIL.MAX}' name: 'High memory utilization' event_name: 'High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)' priority: AVERAGE @@ -526,7 +526,7 @@ zabbix_export: triggers: - uuid: 1c67a764531b48f1a931a9a928a8708d - expression: 'max(/Brocade FC SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' + expression: 'max(/Brocade FC by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING @@ -534,7 +534,7 @@ zabbix_export: dependencies: - name: 'Unavailable by ICMP ping' - expression: 'max(/Brocade FC SNMP/icmpping,#3)=0' + expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0' tags: - tag: scope @@ -589,7 +589,7 @@ zabbix_export: trigger_prototypes: - uuid: 75003433a8304644a20d11b82dcbae14 - expression: 'count(/Brocade FC SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1' + expression: 'count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1' name: '{#SENSOR_INFO}: Fan is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE @@ -603,7 +603,7 @@ zabbix_export: value: performance - uuid: 83e8182fd7034edca8317fa91776b6d2 - expression: 'count(/Brocade FC SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1' + expression: 'count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1' name: '{#SENSOR_INFO}: Fan is not in normal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: INFO @@ -611,7 +611,7 @@ zabbix_export: dependencies: - name: '{#SENSOR_INFO}: Fan is in critical state' - expression: 'count(/Brocade FC SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1' + expression: 'count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1' tags: - tag: scope @@ -920,9 +920,9 @@ zabbix_export: trigger_prototypes: - uuid: e5391912a6b84c1bb41832e88df4fb96 - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' + recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' name: 'Interface {#IFNAME}({#IFALIAS}): Link down' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE @@ -973,21 +973,21 @@ zabbix_export: - uuid: 5a98171af6b342ab97e0c6c9de0bd589 expression: | - change(/Brocade FC SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Brocade FC SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 + change(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( - last(/Brocade FC SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or - last(/Brocade FC SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or - last(/Brocade FC SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or - last(/Brocade FC SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or - last(/Brocade FC SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or - last(/Brocade FC SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 + last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or + last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or + last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or + last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or + last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or + last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and - (last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) + (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) recovery_mode: RECOVERY_EXPRESSION recovery_expression: | - (change(/Brocade FC SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Brocade FC SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or - (last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2) + (change(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or + (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2) name: 'Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before' opdata: 'Current reported speed: {ITEM.LASTVALUE1}' priority: INFO @@ -996,8 +996,8 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' - recovery_expression: 'last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' + recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' tags: - tag: scope @@ -1005,13 +1005,13 @@ zabbix_export: - uuid: a16b52f43a224a11861813be5a11697c expression: | - (avg(/Brocade FC SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Brocade FC SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or - avg(/Brocade FC SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Brocade FC SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and - last(/Brocade FC SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 + (avg(/Brocade FC by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or + avg(/Brocade FC by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and + last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 recovery_mode: RECOVERY_EXPRESSION recovery_expression: | - avg(/Brocade FC SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Brocade FC SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and - avg(/Brocade FC SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Brocade FC SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) + avg(/Brocade FC by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and + avg(/Brocade FC by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage' event_name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage (>{$IF.UTIL.MAX:"{#IFNAME}"}%)' opdata: 'In: {ITEM.LASTVALUE1}, out: {ITEM.LASTVALUE3}, speed: {ITEM.LASTVALUE2}' @@ -1021,8 +1021,8 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' - recovery_expression: 'last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' + recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' tags: - tag: scope @@ -1030,12 +1030,12 @@ zabbix_export: - uuid: 9f42c5a5ed1341c1a26263642e4dabe4 expression: | - min(/Brocade FC SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} - or min(/Brocade FC SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} + min(/Brocade FC by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} + or min(/Brocade FC by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} recovery_mode: RECOVERY_EXPRESSION recovery_expression: | - max(/Brocade FC SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 - and max(/Brocade FC SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 + max(/Brocade FC by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 + and max(/Brocade FC by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 name: 'Interface {#IFNAME}({#IFALIAS}): High error rate' event_name: 'Interface {#IFNAME}({#IFALIAS}): High error rate (>{$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)' opdata: 'errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}' @@ -1045,8 +1045,8 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' - recovery_expression: 'last(/Brocade FC SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' + recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' tags: - tag: scope @@ -1063,42 +1063,42 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Brocade FC SNMP' + host: 'Brocade FC by SNMP' key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]' - sortorder: '1' drawtype: BOLD_LINE color: 2774A4 item: - host: 'Brocade FC SNMP' + host: 'Brocade FC by SNMP' key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]' - sortorder: '2' color: F63100 yaxisside: RIGHT item: - host: 'Brocade FC SNMP' + host: 'Brocade FC by SNMP' key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]' - sortorder: '3' color: A54F10 yaxisside: RIGHT item: - host: 'Brocade FC SNMP' + host: 'Brocade FC by SNMP' key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]' - sortorder: '4' color: FC6EA3 yaxisside: RIGHT item: - host: 'Brocade FC SNMP' + host: 'Brocade FC by SNMP' key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]' - sortorder: '5' color: 6C59DC yaxisside: RIGHT item: - host: 'Brocade FC SNMP' + host: 'Brocade FC by SNMP' key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]' - uuid: 32c9720e348e4d4ebb9e70c2b247de29 @@ -1133,7 +1133,7 @@ zabbix_export: trigger_prototypes: - uuid: 649e7344411242738d9824f861b3c49a - expression: 'count(/Brocade FC SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1' + expression: 'count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1' name: '{#SENSOR_INFO}: Power supply is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE @@ -1147,7 +1147,7 @@ zabbix_export: value: performance - uuid: bfe2f4085f6840da9e8d30f37bb29fdb - expression: 'count(/Brocade FC SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1' + expression: 'count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1' name: '{#SENSOR_INFO}: Power supply is not in normal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: INFO @@ -1155,7 +1155,7 @@ zabbix_export: dependencies: - name: '{#SENSOR_INFO}: Power supply is in critical state' - expression: 'count(/Brocade FC SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1' + expression: 'count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1' tags: - tag: scope @@ -1211,9 +1211,9 @@ zabbix_export: trigger_prototypes: - uuid: 5ee4c1931e244d638b58f945f8a7565c - expression: 'avg(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}' + expression: 'avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3' + recovery_expression: 'max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3' name: '{#SENSOR_INFO}: Temperature is above critical threshold' event_name: '{#SENSOR_INFO}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SENSOR_INFO}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -1228,9 +1228,9 @@ zabbix_export: value: performance - uuid: fc68b3a0ea6643f988c26e3e735d7491 - expression: 'avg(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}' + expression: 'avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'min(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}+3' + recovery_expression: 'min(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}+3' name: '{#SENSOR_INFO}: Temperature is too low' event_name: '{#SENSOR_INFO}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -1246,11 +1246,11 @@ zabbix_export: - uuid: 726afdedb08848bd86ab4161cef29f42 expression: | - avg(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_INFO}"} + avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_INFO}"} or - last(/Brocade FC SNMP/sensor.temp.status[swSensorStatus.{#SNMPINDEX}])={$TEMP_WARN_STATUS} + last(/Brocade FC by SNMP/sensor.temp.status[swSensorStatus.{#SNMPINDEX}])={$TEMP_WARN_STATUS} recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_INFO}"}-3' + recovery_expression: 'max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_INFO}"}-3' name: '{#SENSOR_INFO}: Temperature is above warning threshold' event_name: '{#SENSOR_INFO}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SENSOR_INFO}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -1259,8 +1259,8 @@ zabbix_export: dependencies: - name: '{#SENSOR_INFO}: Temperature is above critical threshold' - expression: 'avg(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}' - recovery_expression: 'max(/Brocade FC SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3' + expression: 'avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}' + recovery_expression: 'max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3' tags: - tag: scope @@ -1404,7 +1404,7 @@ zabbix_export: type: GRAPH_PROTOTYPE name: graphid value: - host: 'Brocade FC SNMP' + host: 'Brocade FC by SNMP' name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic' valuemaps: - @@ -2355,7 +2355,7 @@ zabbix_export: triggers: - uuid: 42bb10d788484b92ac7290e171ee28a2 - expression: '(last(/Brocade FC SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Brocade FC SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Brocade FC SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Brocade FC SNMP/system.net.uptime[sysUpTime.0])<10m)' + expression: '(last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Brocade FC by SNMP/system.net.uptime[sysUpTime.0])<10m)' name: 'Host has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING @@ -2364,7 +2364,7 @@ zabbix_export: dependencies: - name: 'No SNMP data collection' - expression: 'max(/Brocade FC SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' + expression: 'max(/Brocade FC by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' tags: - tag: scope @@ -2380,7 +2380,7 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Brocade FC SNMP' + host: 'Brocade FC by SNMP' key: 'system.cpu.util[swCpuUsage.0]' - uuid: d1e06bb17c2f458699664bfa61c12496 @@ -2392,5 +2392,5 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Brocade FC SNMP' + host: 'Brocade FC by SNMP' key: 'vm.memory.util[swMemUsage.0]' |