Welcome to mirror list, hosted at ThFree Co, Russian Federation.

github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
Diffstat (limited to 'templates/net/cisco/cisco_catalyst_3750_48ts_snmp/README.md')
-rw-r--r--templates/net/cisco/cisco_catalyst_3750_48ts_snmp/README.md62
1 files changed, 31 insertions, 31 deletions
diff --git a/templates/net/cisco/cisco_catalyst_3750_48ts_snmp/README.md b/templates/net/cisco/cisco_catalyst_3750_48ts_snmp/README.md
index 7bcbfd2135b..51055c7901a 100644
--- a/templates/net/cisco/cisco_catalyst_3750_48ts_snmp/README.md
+++ b/templates/net/cisco/cisco_catalyst_3750_48ts_snmp/README.md
@@ -1,9 +1,9 @@
-# Cisco Catalyst 3750V2-48TS SNMP
+# Cisco Catalyst 3750V2-48TS by SNMP
## Overview
-For Zabbix version: 6.4 and higher
+For Zabbix version: 6.4 and higher.
![Product picture](images/pic.png?raw=true)
> Courtesy of Cisco Systems, Inc. Unauthorized use not permitted.
@@ -109,37 +109,37 @@ There are no template links in this template.
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----|----|----|
-|#{#SNMPINDEX}: High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/Cisco Catalyst 3750V2-48TS SNMP/system.cpu.util[{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}` |WARNING | |
-|{#SNMPVALUE}: Fan is in critical state |<p>Please check the fan unit</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.fan.status[{#SNMPINDEX}])=4` |AVERAGE | |
-|{#SNMPVALUE}: Fan is in warning state |<p>Please check the fan unit</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.fan.status[{#SNMPINDEX}])=2` |WARNING |<p>**Depends on**:</p><p>- {#SNMPVALUE}: Fan is in critical state</p> |
-|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-48TS SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-48TS SNMP/system.name))>0` |INFO |<p>Manual close: YES</p> |
-|Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber,#1)<>last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber,#2) and length(last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber))>0` |INFO |<p>Manual close: YES</p> |
-|Operating system description has changed |<p>Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/system.sw.os,#1)<>last(/Cisco Catalyst 3750V2-48TS SNMP/system.sw.os,#2) and length(last(/Cisco Catalyst 3750V2-48TS SNMP/system.sw.os))>0` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- System name has changed</p> |
-|{#ENT_NAME}: Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber[{#SNMPINDEX}],#1)<>last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber[{#SNMPINDEX}],#2) and length(last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber[{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> |
-|{#SNMPVALUE}: High memory utilization |<p>The system is running out of free memory.</p> |`min(/Cisco Catalyst 3750V2-48TS SNMP/vm.memory.util[{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | |
-|Interface {#IFNAME}({#IFALIAS}): High input error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/Cisco Catalyst 3750V2-48TS SNMP/net.if.in.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/Cisco Catalyst 3750V2-48TS SNMP/net.if.in.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|Interface {#IFNAME}({#IFALIAS}): High inbound bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/Cisco Catalyst 3750V2-48TS SNMP/net.if.in[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])) and last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])>0 `<p>Recovery expression:</p>`avg(/Cisco Catalyst 3750V2-48TS SNMP/net.if.in[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|Interface {#IFNAME}({#IFALIAS}): High output error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/Cisco Catalyst 3750V2-48TS SNMP/net.if.out.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/Cisco Catalyst 3750V2-48TS SNMP/net.if.out.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|Interface {#IFNAME}({#IFALIAS}): High outbound bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/Cisco Catalyst 3750V2-48TS SNMP/net.if.out[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])) and last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])>0 `<p>Recovery expression:</p>`avg(/Cisco Catalyst 3750V2-48TS SNMP/net.if.out[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])<0 and last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])>0 and ( last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=6 or last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=7 or last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=11 or last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=62 or last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=69 or last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=117 ) and (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])<>2) `<p>Recovery expression:</p>`(change(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])>0 and last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}],#2)>0) or (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])=2) ` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])=2)` |AVERAGE |<p>Manual close: YES</p> |
-|Interface {#IFNAME}({#IFALIAS}): In half-duplex mode |<p>Please check autonegotiation settings and cabling</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.duplex[{#SNMPINDEX}])=2` |WARNING |<p>Manual close: YES</p> |
-|{#SNMPVALUE}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.psu.status[{#SNMPINDEX}])=4` |AVERAGE | |
-|{#SNMPVALUE}: Power supply is in warning state |<p>Please check the power supply unit for errors</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.psu.status[{#SNMPINDEX}])=2` |WARNING |<p>**Depends on**:</p><p>- {#SNMPVALUE}: Power supply is in critical state</p> |
-|Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/Cisco Catalyst 3750V2-48TS SNMP/icmpping,#3)=0` |HIGH | |
-|High ICMP ping loss |<p>-</p> |`min(/Cisco Catalyst 3750V2-48TS SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-48TS SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
-|High ICMP ping response time |<p>-</p> |`avg(/Cisco Catalyst 3750V2-48TS SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> |
-|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.uptime)>0 and last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.uptime)<10m) or (last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.uptime)=0 and last(/Cisco Catalyst 3750V2-48TS SNMP/system.net.uptime)<10m)` |WARNING |<p>Manual close: YES</p> |
-|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/Cisco Catalyst 3750V2-48TS SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
-|{#SNMPVALUE}: Temperature is in critical state |<p>This trigger uses temperature sensor state</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.status[{#SNMPINDEX}])=4` |HIGH | |
-|{#SNMPVALUE}: Temperature is in warning state |<p>This trigger uses temperature sensor state</p> |`last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.status[{#SNMPINDEX}])=2` |WARNING |<p>**Depends on**:</p><p>- {#SNMPVALUE}: Temperature is in critical state</p> |
-|{#SNMPVALUE}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3` |HIGH | |
-|{#SNMPVALUE}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SNMPVALUE}: Temperature is above critical threshold</p> |
-|{#SNMPVALUE}: Temperature is too low |<p>-</p> |`avg(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`min(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3` |AVERAGE | |
+|#{#SNMPINDEX}: High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/Cisco Catalyst 3750V2-48TS by SNMP/system.cpu.util[{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}` |WARNING | |
+|{#SNMPVALUE}: Fan is in critical state |<p>Please check the fan unit</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=4` |AVERAGE | |
+|{#SNMPVALUE}: Fan is in warning state |<p>Please check the fan unit</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=2` |WARNING |<p>**Depends on**:</p><p>- {#SNMPVALUE}: Fan is in critical state</p> |
+|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name))>0` |INFO |<p>Manual close: YES</p> |
+|Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber))>0` |INFO |<p>Manual close: YES</p> |
+|Operating system description has changed |<p>Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/system.sw.os,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.sw.os,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.sw.os))>0` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- System name has changed</p> |
+|{#ENT_NAME}: Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}],#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}],#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> |
+|{#SNMPVALUE}: High memory utilization |<p>The system is running out of free memory.</p> |`min(/Cisco Catalyst 3750V2-48TS by SNMP/vm.memory.util[{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | |
+|Interface {#IFNAME}({#IFALIAS}): High input error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|Interface {#IFNAME}({#IFALIAS}): High inbound bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])) and last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 `<p>Recovery expression:</p>`avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|Interface {#IFNAME}({#IFALIAS}): High output error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|Interface {#IFNAME}({#IFALIAS}): High outbound bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])) and last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 `<p>Recovery expression:</p>`avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])<0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 and ( last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=6 or last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=7 or last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=11 or last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=62 or last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=69 or last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=117 ) and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])<>2) `<p>Recovery expression:</p>`(change(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}],#2)>0) or (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2) ` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)` |AVERAGE |<p>Manual close: YES</p> |
+|Interface {#IFNAME}({#IFALIAS}): In half-duplex mode |<p>Please check autonegotiation settings and cabling</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.duplex[{#SNMPINDEX}])=2` |WARNING |<p>Manual close: YES</p> |
+|{#SNMPVALUE}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=4` |AVERAGE | |
+|{#SNMPVALUE}: Power supply is in warning state |<p>Please check the power supply unit for errors</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=2` |WARNING |<p>**Depends on**:</p><p>- {#SNMPVALUE}: Power supply is in critical state</p> |
+|Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/Cisco Catalyst 3750V2-48TS by SNMP/icmpping,#3)=0` |HIGH | |
+|High ICMP ping loss |<p>-</p> |`min(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
+|High ICMP ping response time |<p>-</p> |`avg(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> |
+|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.uptime)>0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.uptime)<10m) or (last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.uptime)=0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/system.net.uptime)<10m)` |WARNING |<p>Manual close: YES</p> |
+|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/Cisco Catalyst 3750V2-48TS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
+|{#SNMPVALUE}: Temperature is in critical state |<p>This trigger uses temperature sensor state</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=4` |HIGH | |
+|{#SNMPVALUE}: Temperature is in warning state |<p>This trigger uses temperature sensor state</p> |`last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=2` |WARNING |<p>**Depends on**:</p><p>- {#SNMPVALUE}: Temperature is in critical state</p> |
+|{#SNMPVALUE}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3` |HIGH | |
+|{#SNMPVALUE}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SNMPVALUE}: Temperature is above critical threshold</p> |
+|{#SNMPVALUE}: Temperature is too low |<p>-</p> |`avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`min(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3` |AVERAGE | |
## Feedback
-Please report any issues with the template at https://support.zabbix.com
+Please report any issues with the template at https://support.zabbix.com.
-You can also provide feedback, discuss the template or ask for help with it at [ZABBIX forums](https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/418396-discussion-thread-for-official-zabbix-templates-for-cisco).
+You can also provide feedback, discuss the template, or ask for help at [ZABBIX forums](https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/418396-discussion-thread-for-official-zabbix-templates-for-cisco).