diff options
Diffstat (limited to 'templates/net/cisco/cisco_catalyst_3750_48ts_snmp/template_net_cisco_catalyst_3750_48ts_snmp.yaml')
-rw-r--r-- | templates/net/cisco/cisco_catalyst_3750_48ts_snmp/template_net_cisco_catalyst_3750_48ts_snmp.yaml | 140 |
1 files changed, 70 insertions, 70 deletions
diff --git a/templates/net/cisco/cisco_catalyst_3750_48ts_snmp/template_net_cisco_catalyst_3750_48ts_snmp.yaml b/templates/net/cisco/cisco_catalyst_3750_48ts_snmp/template_net_cisco_catalyst_3750_48ts_snmp.yaml index ecb1b3ceb60..77cca41b70c 100644 --- a/templates/net/cisco/cisco_catalyst_3750_48ts_snmp/template_net_cisco_catalyst_3750_48ts_snmp.yaml +++ b/templates/net/cisco/cisco_catalyst_3750_48ts_snmp/template_net_cisco_catalyst_3750_48ts_snmp.yaml @@ -1,6 +1,6 @@ zabbix_export: version: '6.4' - date: '2022-08-16T10:50:25Z' + date: '2022-10-27T14:41:50Z' template_groups: - uuid: 36bff6c29af64692839d077febfc7079 @@ -8,8 +8,8 @@ zabbix_export: templates: - uuid: f744679600844c07b2b4eedda9bc3d0c - template: 'Cisco Catalyst 3750V2-48TS SNMP' - name: 'Cisco Catalyst 3750V2-48TS SNMP' + template: 'Cisco Catalyst 3750V2-48TS by SNMP' + name: 'Cisco Catalyst 3750V2-48TS by SNMP' description: | Template Cisco Catalyst 3750V2-48TS @@ -47,7 +47,7 @@ zabbix_export: triggers: - uuid: 1dd6a211f5e54351a2d4a0854e66fdba - expression: 'max(/Cisco Catalyst 3750V2-48TS SNMP/icmpping,#3)=0' + expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/icmpping,#3)=0' name: 'Unavailable by ICMP ping' priority: HIGH description: 'Last three attempts returned timeout. Please check device connectivity.' @@ -73,14 +73,14 @@ zabbix_export: triggers: - uuid: 669ae230efe84f76be95f3ac0eac1102 - expression: 'min(/Cisco Catalyst 3750V2-48TS SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-48TS SNMP/icmppingloss,5m)<100' + expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingloss,5m)<100' name: 'High ICMP ping loss' opdata: 'Loss: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Unavailable by ICMP ping' - expression: 'max(/Cisco Catalyst 3750V2-48TS SNMP/icmpping,#3)=0' + expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/icmpping,#3)=0' tags: - tag: scope @@ -106,17 +106,17 @@ zabbix_export: triggers: - uuid: 391b3ac9e1b746c8824af721c472df7b - expression: 'avg(/Cisco Catalyst 3750V2-48TS SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' + expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' name: 'High ICMP ping response time' opdata: 'Value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'High ICMP ping loss' - expression: 'min(/Cisco Catalyst 3750V2-48TS SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-48TS SNMP/icmppingloss,5m)<100' + expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingloss,5m)<100' - name: 'Unavailable by ICMP ping' - expression: 'max(/Cisco Catalyst 3750V2-48TS SNMP/icmpping,#3)=0' + expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/icmpping,#3)=0' tags: - tag: scope @@ -230,7 +230,7 @@ zabbix_export: triggers: - uuid: f63ea5e9c33f465985259c3c8d27a12a - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber,#1)<>last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber,#2) and length(last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber))>0' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber))>0' name: 'Device has been replaced' event_name: 'Device has been replaced (new serial number received)' priority: INFO @@ -316,7 +316,7 @@ zabbix_export: triggers: - uuid: 55ff869f6acb4f2daddf5c855aa3d76d - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-48TS SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-48TS SNMP/system.name))>0' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name))>0' name: 'System name has changed' event_name: 'System name has changed (new name: {ITEM.VALUE})' priority: INFO @@ -397,7 +397,7 @@ zabbix_export: triggers: - uuid: 6724cfef1df145fdb0e6e2cfb35bc890 - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/system.sw.os,#1)<>last(/Cisco Catalyst 3750V2-48TS SNMP/system.sw.os,#2) and length(last(/Cisco Catalyst 3750V2-48TS SNMP/system.sw.os))>0' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/system.sw.os,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.sw.os,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.sw.os))>0' recovery_mode: NONE name: 'Operating system description has changed' priority: INFO @@ -406,7 +406,7 @@ zabbix_export: dependencies: - name: 'System name has changed' - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-48TS SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-48TS SNMP/system.name))>0' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name))>0' tags: - tag: scope @@ -426,7 +426,7 @@ zabbix_export: triggers: - uuid: da0596afe59b455bb503a0b2dea1cebe - expression: 'max(/Cisco Catalyst 3750V2-48TS SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' + expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING @@ -475,7 +475,7 @@ zabbix_export: trigger_prototypes: - uuid: 194c2d8b74c94717a037ce22c31a50e6 - expression: 'min(/Cisco Catalyst 3750V2-48TS SNMP/system.cpu.util[{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}' + expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/system.cpu.util[{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}' name: '#{#SNMPINDEX}: High CPU utilization' event_name: '#{#SNMPINDEX}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)' opdata: 'Current utilization: {ITEM.LASTVALUE1}' @@ -499,7 +499,7 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Cisco Catalyst 3750V2-48TS SNMP' + host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'system.cpu.util[{#SNMPINDEX}]' - uuid: 7b40466007144e82ba7b6081d9d024ae @@ -548,7 +548,7 @@ zabbix_export: trigger_prototypes: - uuid: 7dc178a7bced4003b51b599459e41047 - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber[{#SNMPINDEX}],#1)<>last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber[{#SNMPINDEX}],#2) and length(last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.serialnumber[{#SNMPINDEX}]))>0' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}],#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}],#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}]))>0' name: '{#ENT_NAME}: Device has been replaced' event_name: '{#ENT_NAME}: Device has been replaced (new serial number received)' priority: INFO @@ -589,7 +589,7 @@ zabbix_export: trigger_prototypes: - uuid: 16d0712d6e1f4cb18a65d4cc7e11a8df - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.fan.status[{#SNMPINDEX}])=4' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=4' name: '{#SNMPVALUE}: Fan is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE @@ -603,7 +603,7 @@ zabbix_export: value: performance - uuid: 42ad0109072e404eb47daaf17236d805 - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.fan.status[{#SNMPINDEX}])=2' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=2' name: '{#SNMPVALUE}: Fan is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING @@ -611,7 +611,7 @@ zabbix_export: dependencies: - name: '{#SNMPVALUE}: Fan is in critical state' - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.fan.status[{#SNMPINDEX}])=4' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=4' tags: - tag: scope @@ -690,7 +690,7 @@ zabbix_export: trigger_prototypes: - uuid: 8cf907c229fa4c4c86c1f06e65facef8 - expression: 'min(/Cisco Catalyst 3750V2-48TS SNMP/vm.memory.util[{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}' + expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/vm.memory.util[{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}' name: '{#SNMPVALUE}: High memory utilization' event_name: '{#SNMPVALUE}: High memory utilization ( >{$MEMORY.UTIL.MAX}% for 5m)' priority: AVERAGE @@ -713,7 +713,7 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Cisco Catalyst 3750V2-48TS SNMP' + host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'vm.memory.util[{#SNMPINDEX}]' - uuid: c0be105de4db4c0182833e6a7e0fcd01 @@ -838,9 +838,9 @@ zabbix_export: trigger_prototypes: - uuid: f4fa2946c04d4bdbabc9be4b492cf5f0 - expression: 'min(/Cisco Catalyst 3750V2-48TS SNMP/net.if.in.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}' + expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS SNMP/net.if.in.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8' + recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8' name: 'Interface {#IFNAME}({#IFALIAS}): High input error rate' event_name: 'Interface {#IFNAME}({#IFALIAS}): High input error rate ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)' opdata: 'errors in: {ITEM.LASTVALUE1}' @@ -850,7 +850,7 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])=2)' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' tags: - tag: scope @@ -942,9 +942,9 @@ zabbix_export: trigger_prototypes: - uuid: a14d914fa1404daab227b6d22e71ea69 - expression: 'min(/Cisco Catalyst 3750V2-48TS SNMP/net.if.out.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}' + expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS SNMP/net.if.out.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8' + recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8' name: 'Interface {#IFNAME}({#IFALIAS}): High output error rate' event_name: 'Interface {#IFNAME}({#IFALIAS}): High output error rate ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)' opdata: 'errors out: {ITEM.LASTVALUE2}' @@ -954,7 +954,7 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])=2)' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' tags: - tag: scope @@ -1055,7 +1055,7 @@ zabbix_export: trigger_prototypes: - uuid: 77b810108caa4ae6bd8d8bff06acddb2 - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])=2)' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' name: 'Interface {#IFNAME}({#IFALIAS}): Link down' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE @@ -1101,21 +1101,21 @@ zabbix_export: - uuid: 4eae529fc032412d957f1e0d04261867 expression: | - change(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])<0 and last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])>0 + change(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])<0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 and ( - last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=6 or - last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=7 or - last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=11 or - last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=62 or - last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=69 or - last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.type[{#SNMPINDEX}])=117 + last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=6 or + last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=7 or + last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=11 or + last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=62 or + last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=69 or + last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=117 ) and - (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])<>2) + (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])<>2) recovery_mode: RECOVERY_EXPRESSION recovery_expression: | - (change(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])>0 and last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}],#2)>0) or - (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])=2) + (change(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}],#2)>0) or + (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2) name: 'Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before' opdata: 'Current reported speed: {ITEM.LASTVALUE1}' priority: INFO @@ -1124,7 +1124,7 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])=2)' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' tags: - tag: scope @@ -1132,10 +1132,10 @@ zabbix_export: - uuid: 4e1ee888558346faa54c02b85d320170 expression: | - (avg(/Cisco Catalyst 3750V2-48TS SNMP/net.if.in[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])) and - last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])>0 + (avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])) and + last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'avg(/Cisco Catalyst 3750V2-48TS SNMP/net.if.in[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])' + recovery_expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])' name: 'Interface {#IFNAME}({#IFALIAS}): High inbound bandwidth usage' event_name: 'Interface {#IFNAME}({#IFALIAS}): High inbound bandwidth usage ( > {$IF.UTIL.MAX:"{#IFNAME}"}% )' opdata: 'In: {ITEM.LASTVALUE1}, speed: {ITEM.LASTVALUE2}' @@ -1145,7 +1145,7 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])=2)' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' tags: - tag: scope @@ -1153,10 +1153,10 @@ zabbix_export: - uuid: 7623796067224187b6f692c8b6cbd398 expression: | - (avg(/Cisco Catalyst 3750V2-48TS SNMP/net.if.out[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])) and - last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])>0 + (avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])) and + last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'avg(/Cisco Catalyst 3750V2-48TS SNMP/net.if.out[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.speed[{#SNMPINDEX}])' + recovery_expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])' name: 'Interface {#IFNAME}({#IFALIAS}): High outbound bandwidth usage' event_name: 'Interface {#IFNAME}({#IFALIAS}): High outbound bandwidth usage ( > {$IF.UTIL.MAX:"{#IFNAME}"}% )' opdata: 'Out: {ITEM.LASTVALUE1}, speed: {ITEM.LASTVALUE2}' @@ -1166,7 +1166,7 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.status[{#SNMPINDEX}])=2)' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' tags: - tag: scope @@ -1180,42 +1180,42 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Cisco Catalyst 3750V2-48TS SNMP' + host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.in[{#SNMPINDEX}]' - sortorder: '1' drawtype: BOLD_LINE color: 2774A4 item: - host: 'Cisco Catalyst 3750V2-48TS SNMP' + host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.out[{#SNMPINDEX}]' - sortorder: '2' color: F63100 yaxisside: RIGHT item: - host: 'Cisco Catalyst 3750V2-48TS SNMP' + host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.out.errors[{#SNMPINDEX}]' - sortorder: '3' color: A54F10 yaxisside: RIGHT item: - host: 'Cisco Catalyst 3750V2-48TS SNMP' + host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.in.errors[{#SNMPINDEX}]' - sortorder: '4' color: FC6EA3 yaxisside: RIGHT item: - host: 'Cisco Catalyst 3750V2-48TS SNMP' + host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.out.discards[{#SNMPINDEX}]' - sortorder: '5' color: 6C59DC yaxisside: RIGHT item: - host: 'Cisco Catalyst 3750V2-48TS SNMP' + host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.in.discards[{#SNMPINDEX}]' - uuid: 15992a60957c4ef896ece23744da52f1 @@ -1286,7 +1286,7 @@ zabbix_export: trigger_prototypes: - uuid: a1217d320897464da4bb9a67f669460f - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/net.if.duplex[{#SNMPINDEX}])=2' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.duplex[{#SNMPINDEX}])=2' name: 'Interface {#IFNAME}({#IFALIAS}): In half-duplex mode' priority: WARNING description: 'Please check autonegotiation settings and cabling' @@ -1326,7 +1326,7 @@ zabbix_export: trigger_prototypes: - uuid: 56fced6c99ba44ab9fb5268d946a385b - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.psu.status[{#SNMPINDEX}])=4' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=4' name: '{#SNMPVALUE}: Power supply is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE @@ -1337,7 +1337,7 @@ zabbix_export: value: availability - uuid: 6962e5851f244e9cb9d87763637a20f3 - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.psu.status[{#SNMPINDEX}])=2' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=2' name: '{#SNMPVALUE}: Power supply is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING @@ -1345,7 +1345,7 @@ zabbix_export: dependencies: - name: '{#SNMPVALUE}: Power supply is in critical state' - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.psu.status[{#SNMPINDEX}])=4' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=4' tags: - tag: scope @@ -1384,7 +1384,7 @@ zabbix_export: trigger_prototypes: - uuid: e4844779a080455e9691bdc705227a28 - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.status[{#SNMPINDEX}])=4' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=4' name: '{#SNMPVALUE}: Temperature is in critical state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -1398,7 +1398,7 @@ zabbix_export: value: performance - uuid: 120dd2434317447d8ee6708d5c1221e3 - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.status[{#SNMPINDEX}])=2' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=2' name: '{#SNMPVALUE}: Temperature is in warning state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -1406,7 +1406,7 @@ zabbix_export: dependencies: - name: '{#SNMPVALUE}: Temperature is in critical state' - expression: 'last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.status[{#SNMPINDEX}])=4' + expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=4' tags: - tag: scope @@ -1437,9 +1437,9 @@ zabbix_export: trigger_prototypes: - uuid: 6cecb3ad6e7640cc84b03e3b3943ad07 - expression: 'avg(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' + expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' + recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' name: '{#SNMPVALUE}: Temperature is above critical threshold' event_name: '{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -1454,9 +1454,9 @@ zabbix_export: value: performance - uuid: 6f5d1c3f3c804b6ba17486db5e6e8037 - expression: 'avg(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}' + expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3' + recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3' name: '{#SNMPVALUE}: Temperature is above warning threshold' event_name: '{#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -1465,8 +1465,8 @@ zabbix_export: dependencies: - name: '{#SNMPVALUE}: Temperature is above critical threshold' - expression: 'avg(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' - recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' + expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' + recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' tags: - tag: scope @@ -1476,9 +1476,9 @@ zabbix_export: value: performance - uuid: ed406cbc4b08446991c610c902574cac - expression: 'avg(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}' + expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'min(/Cisco Catalyst 3750V2-48TS SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3' + recovery_expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3' name: '{#SNMPVALUE}: Temperature is too low' event_name: '{#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -2525,7 +2525,7 @@ zabbix_export: triggers: - uuid: 2f1841fb315041a2a437886dc6c23814 - expression: '(last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.uptime)>0 and last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.uptime)<10m) or (last(/Cisco Catalyst 3750V2-48TS SNMP/system.hw.uptime)=0 and last(/Cisco Catalyst 3750V2-48TS SNMP/system.net.uptime)<10m)' + expression: '(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.uptime)>0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.uptime)<10m) or (last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.uptime)=0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/system.net.uptime)<10m)' name: 'Host has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING |