Welcome to mirror list, hosted at ThFree Co, Russian Federation.

github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
Diffstat (limited to 'templates/net/cisco/cisco_snmp/template_net_cisco_snmp.yaml')
-rw-r--r--templates/net/cisco/cisco_snmp/template_net_cisco_snmp.yaml2244
1 files changed, 1122 insertions, 1122 deletions
diff --git a/templates/net/cisco/cisco_snmp/template_net_cisco_snmp.yaml b/templates/net/cisco/cisco_snmp/template_net_cisco_snmp.yaml
index 07a4eaa91fc..3b2ce15d09f 100644
--- a/templates/net/cisco/cisco_snmp/template_net_cisco_snmp.yaml
+++ b/templates/net/cisco/cisco_snmp/template_net_cisco_snmp.yaml
@@ -1,982 +1,15 @@
zabbix_export:
version: '6.4'
- date: '2022-08-16T11:05:02Z'
+ date: '2022-10-27T14:44:38Z'
template_groups:
-
uuid: 36bff6c29af64692839d077febfc7079
name: 'Templates/Network devices'
templates:
-
- uuid: 1bb42fbdb9054645a62ff81f14ba3b99
- template: 'Cisco IOS prior to 12.0_3_T SNMP'
- name: 'Cisco IOS prior to 12.0_3_T SNMP'
- description: |
- Cisco IOS Software releases prior to 12.0(3)T
-
- MIBs used:
- HOST-RESOURCES-MIB
- SNMPv2-MIB
- OLD-CISCO-CPU-MIB
- CISCO-ENVMON-MIB
- CISCO-MEMORY-POOL-MIB
- ENTITY-MIB
-
- Template tooling version used: 0.42
- groups:
- -
- name: 'Templates/Network devices'
- items:
- -
- uuid: bf6d81068770410a929c127d8e7d76c1
- name: 'ICMP ping'
- type: SIMPLE
- key: icmpping
- history: 1w
- valuemap:
- name: 'Service state'
- tags:
- -
- tag: component
- value: health
- -
- tag: component
- value: network
- triggers:
- -
- uuid: fd317d3e8d3d45bf97322b8578f30c04
- expression: 'max(/Cisco IOS prior to 12.0_3_T SNMP/icmpping,#3)=0'
- name: 'Unavailable by ICMP ping'
- priority: HIGH
- description: 'Last three attempts returned timeout. Please check device connectivity.'
- tags:
- -
- tag: scope
- value: availability
- -
- uuid: 2af7b5f79fc44d7d992b0bf6277c12bb
- name: 'ICMP loss'
- type: SIMPLE
- key: icmppingloss
- history: 1w
- value_type: FLOAT
- units: '%'
- tags:
- -
- tag: component
- value: health
- -
- tag: component
- value: network
- triggers:
- -
- uuid: 3576c96601ef40abbeedbde11768141a
- expression: 'min(/Cisco IOS prior to 12.0_3_T SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS prior to 12.0_3_T SNMP/icmppingloss,5m)<100'
- name: 'High ICMP ping loss'
- opdata: 'Loss: {ITEM.LASTVALUE1}'
- priority: WARNING
- dependencies:
- -
- name: 'Unavailable by ICMP ping'
- expression: 'max(/Cisco IOS prior to 12.0_3_T SNMP/icmpping,#3)=0'
- tags:
- -
- tag: scope
- value: availability
- -
- tag: scope
- value: performance
- -
- uuid: 1afa1e8ca21c430598845806bbf0e7a2
- name: 'ICMP response time'
- type: SIMPLE
- key: icmppingsec
- history: 1w
- value_type: FLOAT
- units: s
- tags:
- -
- tag: component
- value: health
- -
- tag: component
- value: network
- triggers:
- -
- uuid: 2941d30058b14d52bd9a723889c8be26
- expression: 'avg(/Cisco IOS prior to 12.0_3_T SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
- name: 'High ICMP ping response time'
- opdata: 'Value: {ITEM.LASTVALUE1}'
- priority: WARNING
- dependencies:
- -
- name: 'High ICMP ping loss'
- expression: 'min(/Cisco IOS prior to 12.0_3_T SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS prior to 12.0_3_T SNMP/icmppingloss,5m)<100'
- -
- name: 'Unavailable by ICMP ping'
- expression: 'max(/Cisco IOS prior to 12.0_3_T SNMP/icmpping,#3)=0'
- tags:
- -
- tag: scope
- value: availability
- -
- tag: scope
- value: performance
- -
- uuid: 53eb0288c9e54490942cedd4ce5f376e
- name: 'SNMP traps (fallback)'
- type: SNMP_TRAP
- key: snmptrap.fallback
- history: 2w
- trends: '0'
- value_type: LOG
- description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items'
- logtimefmt: 'hh:mm:sszyyyy/MM/dd'
- tags:
- -
- tag: component
- value: network
- -
- uuid: bba5be8b3fa54bfbb354b7a2c20fd353
- name: 'System contact details'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.2.1.1.4.0
- key: 'system.contact[sysContact.0]'
- delay: 15m
- history: 2w
- trends: '0'
- value_type: CHAR
- description: |
- MIB: SNMPv2-MIB
- The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
- inventory_link: CONTACT
- preprocessing:
- -
- type: DISCARD_UNCHANGED_HEARTBEAT
- parameters:
- - 12h
- tags:
- -
- tag: component
- value: system
- -
- uuid: 693b0c779f574d869f47b44c4b3ecd58
- name: 'CPU utilization'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.4.1.9.2.1.58
- key: 'system.cpu.util[avgBusy5]'
- delay: 5m
- history: 7d
- value_type: FLOAT
- units: '%'
- description: |
- MIB: OLD-CISCO-CPU-MIB
- 5 minute exponentially-decayed moving average of the CPU busy percentage.
- Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15215-collect-cpu-util-snmp.html
- tags:
- -
- tag: component
- value: cpu
- triggers:
- -
- uuid: 74773fc279864e7daf89cffe9cb2067c
- expression: 'min(/Cisco IOS prior to 12.0_3_T SNMP/system.cpu.util[avgBusy5],5m)>{$CPU.UTIL.CRIT}'
- name: 'High CPU utilization'
- event_name: 'High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
- opdata: 'Current utilization: {ITEM.LASTVALUE1}'
- priority: WARNING
- description: 'CPU utilization is too high. The system might be slow to respond.'
- tags:
- -
- tag: scope
- value: performance
- -
- uuid: 495b26e876a04819a02cf22eaba04e0b
- name: 'System description'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.2.1.1.1.0
- key: 'system.descr[sysDescr.0]'
- delay: 15m
- history: 2w
- trends: '0'
- value_type: CHAR
- description: |
- MIB: SNMPv2-MIB
- A textual description of the entity. This value should
- include the full name and version identification of the system's hardware type, software operating-system, and
- networking software.
- preprocessing:
- -
- type: DISCARD_UNCHANGED_HEARTBEAT
- parameters:
- - 12h
- tags:
- -
- tag: component
- value: system
- -
- uuid: b5121a382d0245f0906bba4530a82ac4
- name: 'Hardware model name'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.13.1
- key: system.hw.model
- delay: 1h
- history: 2w
- trends: '0'
- value_type: CHAR
- description: 'MIB: ENTITY-MIB'
- inventory_link: MODEL
- preprocessing:
- -
- type: DISCARD_UNCHANGED_HEARTBEAT
- parameters:
- - 1d
- tags:
- -
- tag: component
- value: system
- -
- uuid: 5934a35b54464f66ab19152ca393b882
- name: 'Hardware serial number'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.11.1
- key: system.hw.serialnumber
- delay: 1h
- history: 2w
- trends: '0'
- value_type: CHAR
- description: 'MIB: ENTITY-MIB'
- inventory_link: SERIALNO_A
- preprocessing:
- -
- type: DISCARD_UNCHANGED_HEARTBEAT
- parameters:
- - 1d
- tags:
- -
- tag: component
- value: system
- triggers:
- -
- uuid: d53c0d22a67544cf8a2fcd2c8de4d4eb
- expression: 'last(/Cisco IOS prior to 12.0_3_T SNMP/system.hw.serialnumber,#1)<>last(/Cisco IOS prior to 12.0_3_T SNMP/system.hw.serialnumber,#2) and length(last(/Cisco IOS prior to 12.0_3_T SNMP/system.hw.serialnumber))>0'
- name: 'Device has been replaced'
- event_name: 'Device has been replaced (new serial number received)'
- priority: INFO
- description: 'Device serial number has changed. Ack to close'
- manual_close: 'YES'
- tags:
- -
- tag: scope
- value: notice
- -
- uuid: 732ccfd809b44d7fa923c54e6577851d
- name: 'Uptime (hardware)'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.2.1.25.1.1.0
- key: 'system.hw.uptime[hrSystemUptime.0]'
- delay: 30s
- history: 2w
- trends: 0d
- units: uptime
- description: |
- MIB: HOST-RESOURCES-MIB
- The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.
- preprocessing:
- -
- type: CHECK_NOT_SUPPORTED
- parameters:
- - ''
- error_handler: CUSTOM_VALUE
- error_handler_params: '0'
- -
- type: MULTIPLIER
- parameters:
- - '0.01'
- tags:
- -
- tag: component
- value: system
- -
- uuid: 30df666e80bd4875ac761306781061da
- name: 'System location'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.2.1.1.6.0
- key: 'system.location[sysLocation.0]'
- delay: 15m
- history: 2w
- trends: '0'
- value_type: CHAR
- description: |
- MIB: SNMPv2-MIB
- The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.
- inventory_link: LOCATION
- preprocessing:
- -
- type: DISCARD_UNCHANGED_HEARTBEAT
- parameters:
- - 12h
- tags:
- -
- tag: component
- value: system
- -
- uuid: 2e55e75a7baa4195b012e750bac90dcb
- name: 'System name'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.2.1.1.5.0
- key: system.name
- delay: 15m
- history: 2w
- trends: '0'
- value_type: CHAR
- description: |
- MIB: SNMPv2-MIB
- An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
- inventory_link: NAME
- preprocessing:
- -
- type: DISCARD_UNCHANGED_HEARTBEAT
- parameters:
- - 12h
- tags:
- -
- tag: component
- value: system
- triggers:
- -
- uuid: 33b42b1aa448408fa3fb5aadf7375cf8
- expression: 'last(/Cisco IOS prior to 12.0_3_T SNMP/system.name,#1)<>last(/Cisco IOS prior to 12.0_3_T SNMP/system.name,#2) and length(last(/Cisco IOS prior to 12.0_3_T SNMP/system.name))>0'
- name: 'System name has changed'
- event_name: 'System name has changed (new name: {ITEM.VALUE})'
- priority: INFO
- description: 'System name has changed. Ack to close.'
- manual_close: 'YES'
- tags:
- -
- tag: scope
- value: notice
- -
- tag: scope
- value: security
- -
- uuid: 7ecd28b73c0f43a98c3a58467b1cbdc7
- name: 'Uptime (network)'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.2.1.1.3.0
- key: 'system.net.uptime[sysUpTime.0]'
- delay: 30s
- history: 2w
- trends: 0d
- units: uptime
- description: |
- MIB: SNMPv2-MIB
- The time (in hundredths of a second) since the network management portion of the system was last re-initialized.
- preprocessing:
- -
- type: MULTIPLIER
- parameters:
- - '0.01'
- tags:
- -
- tag: component
- value: system
- -
- uuid: cc6e5a6e4f604b639815d9397264c6af
- name: 'System object ID'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.2.1.1.2.0
- key: 'system.objectid[sysObjectID.0]'
- delay: 15m
- history: 2w
- trends: '0'
- value_type: CHAR
- description: |
- MIB: SNMPv2-MIB
- The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
- preprocessing:
- -
- type: DISCARD_UNCHANGED_HEARTBEAT
- parameters:
- - 12h
- tags:
- -
- tag: component
- value: system
- -
- uuid: 70ef7ce7561640b7bc6b5d30235c0ecc
- name: 'Operating system'
- type: SNMP_AGENT
- snmp_oid: 1.3.6.1.2.1.1.1.0
- key: 'system.sw.os[sysDescr.0]'
- delay: 1h
- history: 2w
- trends: '0'
- value_type: CHAR
- description: 'MIB: SNMPv2-MIB'
- inventory_link: OS
- preprocessing:
- -
- type: REGEX
- parameters:
- - 'Version (.+), RELEASE'
- - \1
- -
- type: DISCARD_UNCHANGED_HEARTBEAT
- parameters:
- - 1d
- tags:
- -
- tag: component
- value: os
- triggers:
- -
- uuid: abe57415ff574b878a2ce2a318be86ee
- expression: 'last(/Cisco IOS prior to 12.0_3_T SNMP/system.sw.os[sysDescr.0],#1)<>last(/Cisco IOS prior to 12.0_3_T SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Cisco IOS prior to 12.0_3_T SNMP/system.sw.os[sysDescr.0]))>0'
- name: 'Operating system description has changed'
- priority: INFO
- description: 'Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.'
- manual_close: 'YES'
- dependencies:
- -
- name: 'System name has changed'
- expression: 'last(/Cisco IOS prior to 12.0_3_T SNMP/system.name,#1)<>last(/Cisco IOS prior to 12.0_3_T SNMP/system.name,#2) and length(last(/Cisco IOS prior to 12.0_3_T SNMP/system.name))>0'
- tags:
- -
- tag: scope
- value: notice
- -
- uuid: 5a156e9ca10c49bbb87cf3de1b686cff
- name: 'SNMP agent availability'
- type: INTERNAL
- key: 'zabbix[host,snmp,available]'
- history: 7d
- description: |
- Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
- Possible value:
- 0 - not available
- 1 - available
- 2 - unknown
- valuemap:
- name: zabbix.host.available
- tags:
- -
- tag: component
- value: health
- -
- tag: component
- value: network
- triggers:
- -
- uuid: 86d8603903504287b07a25530c8eda2b
- expression: 'max(/Cisco IOS prior to 12.0_3_T SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
- name: 'No SNMP data collection'
- opdata: 'Current state: {ITEM.LASTVALUE1}'
- priority: WARNING
- description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
- dependencies:
- -
- name: 'Unavailable by ICMP ping'
- expression: 'max(/Cisco IOS prior to 12.0_3_T SNMP/icmpping,#3)=0'
- tags:
- -
- tag: scope
- value: availability
- discovery_rules:
- -
- uuid: fbeef9c16d9d45b7a5c50f530a697f76
- name: 'Entity Serial Numbers Discovery'
- type: SNMP_AGENT
- snmp_oid: 'discovery[{#ENT_CLASS},1.3.6.1.2.1.47.1.1.1.1.5,{#ENT_NAME},1.3.6.1.2.1.47.1.1.1.1.7,{#ENT_SN},1.3.6.1.2.1.47.1.1.1.1.11]'
- key: entity_sn.discovery
- delay: 1h
- filter:
- evaltype: AND
- conditions:
- -
- macro: '{#ENT_SN}'
- value: .+
- formulaid: B
- -
- macro: '{#ENT_CLASS}'
- value: ^3$
- formulaid: A
- item_prototypes:
- -
- uuid: 1993495d289d407e85c24f4986819ab8
- name: '{#ENT_NAME}: Hardware serial number'
- type: SNMP_AGENT
- snmp_oid: '1.3.6.1.2.1.47.1.1.1.1.11.{#SNMPINDEX}'
- key: 'system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]'
- delay: 1h
- history: 2w
- trends: '0'
- value_type: CHAR
- description: 'MIB: ENTITY-MIB'
- preprocessing:
- -
- type: DISCARD_UNCHANGED_HEARTBEAT
- parameters:
- - 1d
- tags:
- -
- tag: component
- value: system
- trigger_prototypes:
- -
- uuid: e8c328ad70a146219a8ae62f101cfc00
- expression: 'last(/Cisco IOS prior to 12.0_3_T SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#1)<>last(/Cisco IOS prior to 12.0_3_T SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#2) and length(last(/Cisco IOS prior to 12.0_3_T SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]))>0'
- name: '{#ENT_NAME}: Device has been replaced'
- event_name: '{#ENT_NAME}: Device has been replaced (new serial number received)'
- priority: INFO
- description: 'Device serial number has changed. Ack to close'
- manual_close: 'YES'
- tags:
- -
- tag: scope
- value: notice
- -
- uuid: 109cd000cd044e4096bf98dbf57b72d1
- name: 'FAN Discovery'
- type: SNMP_AGENT
- snmp_oid: 'discovery[{#SENSOR_INFO},1.3.6.1.4.1.9.9.13.1.4.1.2]'
- key: fan.discovery
- delay: 1h
- description: 'The table of fan status maintained by the environmental monitor.'
- item_prototypes:
- -
- uuid: 7008cccccf2647918bce95bb0a6193df
- name: '{#SENSOR_INFO}: Fan status'
- type: SNMP_AGENT
- snmp_oid: '1.3.6.1.4.1.9.9.13.1.4.1.3.{#SNMPINDEX}'
- key: 'sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}]'
- delay: 3m
- history: 2w
- trends: 0d
- description: 'MIB: CISCO-ENVMON-MIB'
- valuemap:
- name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
- tags:
- -
- tag: component
- value: fan
- trigger_prototypes:
- -
- uuid: ddd7015dd3204514beea29edc45c3cd4
- expression: 'count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
- name: '{#SENSOR_INFO}: Fan is in critical state'
- opdata: 'Current state: {ITEM.LASTVALUE1}'
- priority: AVERAGE
- description: 'Please check the fan unit'
- tags:
- -
- tag: scope
- value: availability
- -
- tag: scope
- value: performance
- -
- uuid: 4eb7ea3405d74740a12095a07d91d48f
- expression: 'count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"notFunctioning\"}")=1'
- name: '{#SENSOR_INFO}: Fan is in warning state'
- opdata: 'Current state: {ITEM.LASTVALUE1}'
- priority: WARNING
- description: 'Please check the fan unit'
- dependencies:
- -
- name: '{#SENSOR_INFO}: Fan is in critical state'
- expression: 'count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
- tags:
- -
- tag: scope
- value: availability
- -
- tag: scope
- value: performance
- -
- uuid: 727adcf658d141ff9e45744107a58c38
- name: 'Memory Discovery'
- type: SNMP_AGENT
- snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.48.1.1.1.2]'
- key: memory.discovery
- delay: 1h
- description: |
- Discovery of ciscoMemoryPoolTable, a table of memory pool monitoring entries.
- http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
- item_prototypes:
- -
- uuid: e0df9d6e31384da4af18ab191e467814
- name: '{#SNMPVALUE}: Free memory'
- type: SNMP_AGENT
- snmp_oid: '1.3.6.1.4.1.9.9.48.1.1.1.6.{#SNMPINDEX}'
- key: 'vm.memory.free[ciscoMemoryPoolFree.{#SNMPINDEX}]'
- history: 7d
- units: B
- description: |
- MIB: CISCO-MEMORY-POOL-MIB
- Indicates the number of bytes from the memory pool that are currently unused on the managed device. Note that the sum of ciscoMemoryPoolUsed and ciscoMemoryPoolFree is the total amount of memory in the pool
- Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
- tags:
- -
- tag: component
- value: memory
- -
- uuid: 25471f4acc4348bf978792fcfaff6acc
- name: '{#SNMPVALUE}: Used memory'
- type: SNMP_AGENT
- snmp_oid: '1.3.6.1.4.1.9.9.48.1.1.1.5.{#SNMPINDEX}'
- key: 'vm.memory.used[ciscoMemoryPoolUsed.{#SNMPINDEX}]'
- history: 7d
- units: B
- description: |
- MIB: CISCO-MEMORY-POOL-MIB
- Indicates the number of bytes from the memory pool that are currently in use by applications on the managed device.
- Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
- tags:
- -
- tag: component
- value: memory
- -
- uuid: 9a03c1b1c6ae42e5ab1886c172b2e3ac
- name: '{#SNMPVALUE}: Memory utilization'
- type: CALCULATED
- key: 'vm.memory.util[vm.memory.util.{#SNMPINDEX}]'
- history: 7d
- value_type: FLOAT
- units: '%'
- params: 'last(//vm.memory.used[ciscoMemoryPoolUsed.{#SNMPINDEX}])/(last(//vm.memory.free[ciscoMemoryPoolFree.{#SNMPINDEX}])+last(//vm.memory.used[ciscoMemoryPoolUsed.{#SNMPINDEX}]))*100'
- description: 'Memory utilization in %.'
- tags:
- -
- tag: component
- value: memory
- trigger_prototypes:
- -
- uuid: 8793ba7767cc415a80a6a206aaf01f11
- expression: 'min(/Cisco IOS prior to 12.0_3_T SNMP/vm.memory.util[vm.memory.util.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
- name: '{#SNMPVALUE}: High memory utilization'
- event_name: '{#SNMPVALUE}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
- priority: AVERAGE
- description: 'The system is running out of free memory.'
- tags:
- -
- tag: scope
- value: capacity
- -
- tag: scope
- value: performance
- graph_prototypes:
- -
- uuid: dd0520d162fe4230900d33472944677f
- name: '{#SNMPVALUE}: Memory utilization'
- ymin_type_1: FIXED
- ymax_type_1: FIXED
- graph_items:
- -
- drawtype: GRADIENT_LINE
- color: 1A7C11
- item:
- host: 'Cisco IOS prior to 12.0_3_T SNMP'
- key: 'vm.memory.util[vm.memory.util.{#SNMPINDEX}]'
- -
- uuid: 5e67e9c84ac54dea866893207a42d3e3
- name: 'PSU Discovery'
- type: SNMP_AGENT
- snmp_oid: 'discovery[{#SENSOR_INFO},1.3.6.1.4.1.9.9.13.1.5.1.2]'
- key: psu.discovery
- delay: 1h
- description: 'The table of power supply status maintained by the environmental monitor card.'
- item_prototypes:
- -
- uuid: d05d99a68e3540d09d64b8bab5d63004
- name: '{#SENSOR_INFO}: Power supply status'
- type: SNMP_AGENT
- snmp_oid: '1.3.6.1.4.1.9.9.13.1.5.1.3.{#SNMPINDEX}'
- key: 'sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}]'
- delay: 3m
- history: 2w
- trends: 0d
- description: 'MIB: CISCO-ENVMON-MIB'
- valuemap:
- name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
- tags:
- -
- tag: component
- value: power
- trigger_prototypes:
- -
- uuid: fc4b6f155d3646c3bb8b27d35c18604b
- expression: 'count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
- name: '{#SENSOR_INFO}: Power supply is in critical state'
- opdata: 'Current state: {ITEM.LASTVALUE1}'
- priority: AVERAGE
- description: 'Please check the power supply unit for errors'
- tags:
- -
- tag: scope
- value: availability
- -
- tag: scope
- value: performance
- -
- uuid: 58e9514d75f84c989b052cfd76ceed4a
- expression: 'count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"notFunctioning\"}")=1'
- name: '{#SENSOR_INFO}: Power supply is in warning state'
- opdata: 'Current state: {ITEM.LASTVALUE1}'
- priority: WARNING
- description: 'Please check the power supply unit for errors'
- dependencies:
- -
- name: '{#SENSOR_INFO}: Power supply is in critical state'
- expression: 'count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS prior to 12.0_3_T SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
- tags:
- -
- tag: scope
- value: availability
- -
- tag: scope
- value: performance
- -
- uuid: 73d10f48886443248f7d2d9167fcfee5
- name: 'Temperature Discovery'
- type: SNMP_AGENT
- snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.3.1.2]'
- key: temperature.discovery
- delay: 1h
- description: |
- Discovery of ciscoEnvMonTemperatureTable (ciscoEnvMonTemperatureDescr), a table of ambient temperature status
- maintained by the environmental monitor.
- item_prototypes:
- -
- uuid: a12075ae5b834eeeb742fed6f7afc39d
- name: '{#SNMPVALUE}: Temperature status'
- type: SNMP_AGENT
- snmp_oid: '1.3.6.1.4.1.9.9.13.1.3.1.6.{#SNMPINDEX}'
- key: 'sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}]'
- delay: 3m
- history: 2w
- trends: 0d
- description: |
- MIB: CISCO-ENVMON-MIB
- The current state of the test point being instrumented.
- valuemap:
- name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
- tags:
- -
- tag: component
- value: temperature
- -
- uuid: ea0d56dd49104257ba6c14ce3bdb753a
- name: '{#SNMPVALUE}: Temperature'
- type: SNMP_AGENT
- snmp_oid: '1.3.6.1.4.1.9.9.13.1.3.1.3.{#SNMPINDEX}'
- key: 'sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}]'
- delay: 3m
- value_type: FLOAT
- units: °C
- description: |
- MIB: CISCO-ENVMON-MIB
- The current measurement of the test point being instrumented.
- tags:
- -
- tag: component
- value: temperature
- trigger_prototypes:
- -
- uuid: 716dee103c9f4e9da5f83d6cc338617d
- expression: 'avg(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
- recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'min(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
- name: '{#SNMPVALUE}: Temperature is too low'
- event_name: '{#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
- opdata: 'Current value: {ITEM.LASTVALUE1}'
- priority: AVERAGE
- tags:
- -
- tag: scope
- value: availability
- -
- tag: scope
- value: performance
- trigger_prototypes:
- -
- uuid: 82fa9473dc7d49d4a3a230ef6238cd2c
- expression: |
- avg(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
- or
- last(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
- or
- last(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
- recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'max(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
- name: '{#SNMPVALUE}: Temperature is above critical threshold'
- event_name: '{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}'
- opdata: 'Current value: {ITEM.LASTVALUE1}'
- priority: HIGH
- description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
- tags:
- -
- tag: scope
- value: availability
- -
- tag: scope
- value: performance
- -
- uuid: a0199088767f43c0990f5ac8793267b1
- expression: |
- avg(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}
- or
- last(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_WARN_STATUS}
- recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'max(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
- name: '{#SNMPVALUE}: Temperature is above warning threshold'
- event_name: '{#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}'
- opdata: 'Current value: {ITEM.LASTVALUE1}'
- priority: WARNING
- description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
- dependencies:
- -
- name: '{#SNMPVALUE}: Temperature is above critical threshold'
- expression: |
- avg(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
- or
- last(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
- or
- last(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
- recovery_expression: 'max(/Cisco IOS prior to 12.0_3_T SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
- tags:
- -
- tag: scope
- value: availability
- -
- tag: scope
- value: performance
- tags:
- -
- tag: class
- value: network
- -
- tag: target
- value: cisco
- -
- tag: target
- value: cisco-prior
- -
- tag: target
- value: cisco-prior-12.0-3-t
- macros:
- -
- macro: '{$CPU.UTIL.CRIT}'
- value: '90'
- -
- macro: '{$FAN_CRIT_STATUS:"critical"}'
- value: '3'
- -
- macro: '{$FAN_CRIT_STATUS:"shutdown"}'
- value: '4'
- -
- macro: '{$FAN_WARN_STATUS:"notFunctioning"}'
- value: '6'
- -
- macro: '{$FAN_WARN_STATUS:"warning"}'
- value: '2'
- -
- macro: '{$ICMP_LOSS_WARN}'
- value: '20'
- -
- macro: '{$ICMP_RESPONSE_TIME_WARN}'
- value: '0.15'
- -
- macro: '{$MEMORY.UTIL.MAX}'
- value: '90'
- -
- macro: '{$PSU_CRIT_STATUS:"critical"}'
- value: '3'
- -
- macro: '{$PSU_CRIT_STATUS:"shutdown"}'
- value: '4'
- -
- macro: '{$PSU_WARN_STATUS:"notFunctioning"}'
- value: '6'
- -
- macro: '{$PSU_WARN_STATUS:"warning"}'
- value: '2'
- -
- macro: '{$SNMP.TIMEOUT}'
- value: 5m
- -
- macro: '{$TEMP_CRIT}'
- value: '60'
- -
- macro: '{$TEMP_CRIT:"CPU"}'
- value: '75'
- -
- macro: '{$TEMP_CRIT_LOW}'
- value: '5'
- -
- macro: '{$TEMP_CRIT_STATUS}'
- value: '3'
- -
- macro: '{$TEMP_DISASTER_STATUS}'
- value: '4'
- -
- macro: '{$TEMP_WARN}'
- value: '50'
- -
- macro: '{$TEMP_WARN:"CPU"}'
- value: '70'
- -
- macro: '{$TEMP_WARN_STATUS}'
- value: '2'
- valuemaps:
- -
- uuid: 0e5588b6aa714283b436031ff8ebc93a
- name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
- mappings:
- -
- value: '1'
- newvalue: normal
- -
- value: '2'
- newvalue: warning
- -
- value: '3'
- newvalue: critical
- -
- value: '4'
- newvalue: shutdown
- -
- value: '5'
- newvalue: notPresent
- -
- value: '6'
- newvalue: notFunctioning
- -
- uuid: 9fc9d3c2eb254de996d9c4a61ba58671
- name: 'Service state'
- mappings:
- -
- value: '0'
- newvalue: Down
- -
- value: '1'
- newvalue: Up
- -
- uuid: bb13061dd5b542f9b0f5921e75866679
- name: zabbix.host.available
- mappings:
- -
- value: '0'
- newvalue: 'not available'
- -
- value: '1'
- newvalue: available
- -
- value: '2'
- newvalue: unknown
- -
uuid: aa3ce9bd8c1d40a2b0f83f9e642e88ee
- template: 'Cisco IOS SNMP'
- name: 'Cisco IOS SNMP'
+ template: 'Cisco IOS by SNMP'
+ name: 'Cisco IOS by SNMP'
description: |
Template Cisco IOS Software releases 12.2(3.5) or later
@@ -1019,7 +52,7 @@ zabbix_export:
triggers:
-
uuid: 77e52d690bc043e389ad8d705dbb86b9
- expression: 'max(/Cisco IOS SNMP/icmpping,#3)=0'
+ expression: 'max(/Cisco IOS by SNMP/icmpping,#3)=0'
name: 'Unavailable by ICMP ping'
priority: HIGH
description: 'Last three attempts returned timeout. Please check device connectivity.'
@@ -1045,14 +78,14 @@ zabbix_export:
triggers:
-
uuid: 62b3c0a2654f4372a1bad40a0fd2898d
- expression: 'min(/Cisco IOS SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS SNMP/icmppingloss,5m)<100'
+ expression: 'min(/Cisco IOS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS by SNMP/icmppingloss,5m)<100'
name: 'High ICMP ping loss'
opdata: 'Loss: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'Unavailable by ICMP ping'
- expression: 'max(/Cisco IOS SNMP/icmpping,#3)=0'
+ expression: 'max(/Cisco IOS by SNMP/icmpping,#3)=0'
tags:
-
tag: scope
@@ -1078,17 +111,17 @@ zabbix_export:
triggers:
-
uuid: 1ba34b5e344147d5b27431906037bc04
- expression: 'avg(/Cisco IOS SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
+ expression: 'avg(/Cisco IOS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
name: 'High ICMP ping response time'
opdata: 'Value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'High ICMP ping loss'
- expression: 'min(/Cisco IOS SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS SNMP/icmppingloss,5m)<100'
+ expression: 'min(/Cisco IOS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS by SNMP/icmppingloss,5m)<100'
-
name: 'Unavailable by ICMP ping'
- expression: 'max(/Cisco IOS SNMP/icmpping,#3)=0'
+ expression: 'max(/Cisco IOS by SNMP/icmpping,#3)=0'
tags:
-
tag: scope
@@ -1202,7 +235,7 @@ zabbix_export:
triggers:
-
uuid: 7d1460eaf7ad46fd8a1b5df3c20051ba
- expression: 'last(/Cisco IOS SNMP/system.hw.serialnumber,#1)<>last(/Cisco IOS SNMP/system.hw.serialnumber,#2) and length(last(/Cisco IOS SNMP/system.hw.serialnumber))>0'
+ expression: 'last(/Cisco IOS by SNMP/system.hw.serialnumber,#1)<>last(/Cisco IOS by SNMP/system.hw.serialnumber,#2) and length(last(/Cisco IOS by SNMP/system.hw.serialnumber))>0'
name: 'Device has been replaced'
event_name: 'Device has been replaced (new serial number received)'
priority: INFO
@@ -1289,7 +322,7 @@ zabbix_export:
triggers:
-
uuid: 2105744d4efd4a239c5b6ab615746a40
- expression: 'last(/Cisco IOS SNMP/system.name,#1)<>last(/Cisco IOS SNMP/system.name,#2) and length(last(/Cisco IOS SNMP/system.name))>0'
+ expression: 'last(/Cisco IOS by SNMP/system.name,#1)<>last(/Cisco IOS by SNMP/system.name,#2) and length(last(/Cisco IOS by SNMP/system.name))>0'
name: 'System name has changed'
event_name: 'System name has changed (new name: {ITEM.VALUE})'
priority: INFO
@@ -1375,7 +408,7 @@ zabbix_export:
triggers:
-
uuid: 2d97173405594074bfe2cc6f3d0cae70
- expression: 'last(/Cisco IOS SNMP/system.sw.os[sysDescr.0],#1)<>last(/Cisco IOS SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Cisco IOS SNMP/system.sw.os[sysDescr.0]))>0'
+ expression: 'last(/Cisco IOS by SNMP/system.sw.os[sysDescr.0],#1)<>last(/Cisco IOS by SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Cisco IOS by SNMP/system.sw.os[sysDescr.0]))>0'
name: 'Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.'
@@ -1383,7 +416,7 @@ zabbix_export:
dependencies:
-
name: 'System name has changed'
- expression: 'last(/Cisco IOS SNMP/system.name,#1)<>last(/Cisco IOS SNMP/system.name,#2) and length(last(/Cisco IOS SNMP/system.name))>0'
+ expression: 'last(/Cisco IOS by SNMP/system.name,#1)<>last(/Cisco IOS by SNMP/system.name,#2) and length(last(/Cisco IOS by SNMP/system.name))>0'
tags:
-
tag: scope
@@ -1412,7 +445,7 @@ zabbix_export:
triggers:
-
uuid: df7c9ed5d3164e73a792f82ecad6ba13
- expression: 'max(/Cisco IOS SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
+ expression: 'max(/Cisco IOS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
name: 'No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
@@ -1420,7 +453,7 @@ zabbix_export:
dependencies:
-
name: 'Unavailable by ICMP ping'
- expression: 'max(/Cisco IOS SNMP/icmpping,#3)=0'
+ expression: 'max(/Cisco IOS by SNMP/icmpping,#3)=0'
tags:
-
tag: scope
@@ -1461,7 +494,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 89b292f6748f49fa8b0f23f5378944b2
- expression: 'min(/Cisco IOS SNMP/system.cpu.util[cpmCPUTotal5minRev.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
+ expression: 'min(/Cisco IOS by SNMP/system.cpu.util[cpmCPUTotal5minRev.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
name: '#{#SNMPINDEX}: High CPU utilization'
event_name: '#{#SNMPINDEX}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
opdata: 'Current utilization: {ITEM.LASTVALUE1}'
@@ -1482,7 +515,7 @@ zabbix_export:
drawtype: GRADIENT_LINE
color: 1A7C11
item:
- host: 'Cisco IOS SNMP'
+ host: 'Cisco IOS by SNMP'
key: 'system.cpu.util[cpmCPUTotal5minRev.{#SNMPINDEX}]'
-
uuid: e8c57e436eed4958a0a83c7afd6a07e3
@@ -1526,7 +559,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: e5477e6803974060ba3ce8a131d97d40
- expression: 'last(/Cisco IOS SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#1)<>last(/Cisco IOS SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#2) and length(last(/Cisco IOS SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]))>0'
+ expression: 'last(/Cisco IOS by SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#1)<>last(/Cisco IOS by SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#2) and length(last(/Cisco IOS by SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]))>0'
name: '{#ENT_NAME}: Device has been replaced'
event_name: '{#ENT_NAME}: Device has been replaced (new serial number received)'
priority: INFO
@@ -1564,7 +597,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: e64b0790509c4a21b7ead959fa1b7951
- expression: 'count(/Cisco IOS SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
+ expression: 'count(/Cisco IOS by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
name: '{#SENSOR_INFO}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
@@ -1578,7 +611,7 @@ zabbix_export:
value: performance
-
uuid: 33207a0c65e14a5d9355690c8d9d54e2
- expression: 'count(/Cisco IOS SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"notFunctioning\"}")=1'
+ expression: 'count(/Cisco IOS by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"notFunctioning\"}")=1'
name: '{#SENSOR_INFO}: Fan is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
@@ -1586,7 +619,7 @@ zabbix_export:
dependencies:
-
name: '{#SENSOR_INFO}: Fan is in critical state'
- expression: 'count(/Cisco IOS SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
+ expression: 'count(/Cisco IOS by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
tags:
-
tag: scope
@@ -1654,7 +687,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: ee300a1f9f644bdbb545bd65d59d4837
- expression: 'min(/Cisco IOS SNMP/vm.memory.util[vm.memory.util.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
+ expression: 'min(/Cisco IOS by SNMP/vm.memory.util[vm.memory.util.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
name: '{#SNMPVALUE}: High memory utilization'
event_name: '{#SNMPVALUE}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
priority: AVERAGE
@@ -1677,7 +710,7 @@ zabbix_export:
drawtype: GRADIENT_LINE
color: 1A7C11
item:
- host: 'Cisco IOS SNMP'
+ host: 'Cisco IOS by SNMP'
key: 'vm.memory.util[vm.memory.util.{#SNMPINDEX}]'
-
uuid: b416fb001e46464f847578a50451164b
@@ -1983,9 +1016,9 @@ zabbix_export:
trigger_prototypes:
-
uuid: 6bf13b6cac1b438bbfe384a746646597
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ recovery_expression: 'last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
@@ -2036,21 +1069,21 @@ zabbix_export:
-
uuid: 3783d41e790f4d1e9ebb7340d82edc1f
expression: |
- change(/Cisco IOS SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Cisco IOS SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
+ change(/Cisco IOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Cisco IOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
and (
- last(/Cisco IOS SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or
- last(/Cisco IOS SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or
- last(/Cisco IOS SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or
- last(/Cisco IOS SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or
- last(/Cisco IOS SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or
- last(/Cisco IOS SNMP/net.if.type[ifType.{#SNMPINDEX}])=117
+ last(/Cisco IOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or
+ last(/Cisco IOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or
+ last(/Cisco IOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or
+ last(/Cisco IOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or
+ last(/Cisco IOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or
+ last(/Cisco IOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117
)
and
- (last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)
+ (last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
- (change(/Cisco IOS SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Cisco IOS SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or
- (last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)
+ (change(/Cisco IOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Cisco IOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or
+ (last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)
name: 'Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before'
opdata: 'Current reported speed: {ITEM.LASTVALUE1}'
priority: INFO
@@ -2059,8 +1092,8 @@ zabbix_export:
dependencies:
-
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
- recovery_expression: 'last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ recovery_expression: 'last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
-
tag: scope
@@ -2068,13 +1101,13 @@ zabbix_export:
-
uuid: 17a07d8b87c04874bfbf12009e1da65f
expression: |
- (avg(/Cisco IOS SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco IOS SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or
- avg(/Cisco IOS SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco IOS SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and
- last(/Cisco IOS SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
+ (avg(/Cisco IOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco IOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or
+ avg(/Cisco IOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco IOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and
+ last(/Cisco IOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
- avg(/Cisco IOS SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco IOS SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and
- avg(/Cisco IOS SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco IOS SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])
+ avg(/Cisco IOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco IOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and
+ avg(/Cisco IOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco IOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])
name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage'
event_name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage (>{$IF.UTIL.MAX:"{#IFNAME}"}%)'
opdata: 'In: {ITEM.LASTVALUE1}, out: {ITEM.LASTVALUE3}, speed: {ITEM.LASTVALUE2}'
@@ -2084,8 +1117,8 @@ zabbix_export:
dependencies:
-
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
- recovery_expression: 'last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ recovery_expression: 'last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
-
tag: scope
@@ -2093,12 +1126,12 @@ zabbix_export:
-
uuid: 0c1c6f8fc17849a68a12813389da6373
expression: |
- min(/Cisco IOS SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
- or min(/Cisco IOS SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
+ min(/Cisco IOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
+ or min(/Cisco IOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
- max(/Cisco IOS SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
- and max(/Cisco IOS SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
+ max(/Cisco IOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
+ and max(/Cisco IOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
name: 'Interface {#IFNAME}({#IFALIAS}): High error rate'
event_name: 'Interface {#IFNAME}({#IFALIAS}): High error rate (>{$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)'
opdata: 'errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}'
@@ -2108,8 +1141,8 @@ zabbix_export:
dependencies:
-
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
- recovery_expression: 'last(/Cisco IOS SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ recovery_expression: 'last(/Cisco IOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
-
tag: scope
@@ -2126,42 +1159,42 @@ zabbix_export:
drawtype: GRADIENT_LINE
color: 1A7C11
item:
- host: 'Cisco IOS SNMP'
+ host: 'Cisco IOS by SNMP'
key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]'
-
sortorder: '1'
drawtype: BOLD_LINE
color: 2774A4
item:
- host: 'Cisco IOS SNMP'
+ host: 'Cisco IOS by SNMP'
key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]'
-
sortorder: '2'
color: F63100
yaxisside: RIGHT
item:
- host: 'Cisco IOS SNMP'
+ host: 'Cisco IOS by SNMP'
key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]'
-
sortorder: '3'
color: A54F10
yaxisside: RIGHT
item:
- host: 'Cisco IOS SNMP'
+ host: 'Cisco IOS by SNMP'
key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]'
-
sortorder: '4'
color: FC6EA3
yaxisside: RIGHT
item:
- host: 'Cisco IOS SNMP'
+ host: 'Cisco IOS by SNMP'
key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]'
-
sortorder: '5'
color: 6C59DC
yaxisside: RIGHT
item:
- host: 'Cisco IOS SNMP'
+ host: 'Cisco IOS by SNMP'
key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]'
-
uuid: d79d3a6026bd4d1f877fc164a3eb7f84
@@ -2231,7 +1264,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 251a80d2f6824e33b8edfca94e0f335d
- expression: 'last(/Cisco IOS SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2'
+ expression: 'last(/Cisco IOS by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2'
name: 'Interface {#IFNAME}({#IFALIAS}): In half-duplex mode'
priority: WARNING
description: 'Please check autonegotiation settings and cabling'
@@ -2286,7 +1319,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 3068fc8f0b0749d4b76d97d7f500e36d
- expression: 'count(/Cisco IOS SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
+ expression: 'count(/Cisco IOS by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
name: '{#SENSOR_INFO}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
@@ -2300,7 +1333,7 @@ zabbix_export:
value: performance
-
uuid: 194444afb5d143a0a0734120e26066e4
- expression: 'count(/Cisco IOS SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"notFunctioning\"}")=1'
+ expression: 'count(/Cisco IOS by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"notFunctioning\"}")=1'
name: '{#SENSOR_INFO}: Power supply is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
@@ -2308,7 +1341,7 @@ zabbix_export:
dependencies:
-
name: '{#SENSOR_INFO}: Power supply is in critical state'
- expression: 'count(/Cisco IOS SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
+ expression: 'count(/Cisco IOS by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
tags:
-
tag: scope
@@ -2364,9 +1397,9 @@ zabbix_export:
trigger_prototypes:
-
uuid: 64888770ef6a44089593e78d4d2c528d
- expression: 'avg(/Cisco IOS SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
+ expression: 'avg(/Cisco IOS by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'min(/Cisco IOS SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
+ recovery_expression: 'min(/Cisco IOS by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
name: '{#SNMPVALUE}: Temperature is too low'
event_name: '{#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
@@ -2382,13 +1415,13 @@ zabbix_export:
-
uuid: 95f562a5b2fb4e17b091eaed07c77d4a
expression: |
- avg(/Cisco IOS SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
+ avg(/Cisco IOS by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
or
- last(/Cisco IOS SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
+ last(/Cisco IOS by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
or
- last(/Cisco IOS SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
+ last(/Cisco IOS by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'max(/Cisco IOS SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
+ recovery_expression: 'max(/Cisco IOS by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
name: '{#SNMPVALUE}: Temperature is above critical threshold'
event_name: '{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
@@ -2404,11 +1437,11 @@ zabbix_export:
-
uuid: 5809893fb23a452ebad327c595322619
expression: |
- avg(/Cisco IOS SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}
+ avg(/Cisco IOS by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}
or
- last(/Cisco IOS SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_WARN_STATUS}
+ last(/Cisco IOS by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_WARN_STATUS}
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'max(/Cisco IOS SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
+ recovery_expression: 'max(/Cisco IOS by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
name: '{#SNMPVALUE}: Temperature is above warning threshold'
event_name: '{#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
@@ -2418,12 +1451,12 @@ zabbix_export:
-
name: '{#SNMPVALUE}: Temperature is above critical threshold'
expression: |
- avg(/Cisco IOS SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
+ avg(/Cisco IOS by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
or
- last(/Cisco IOS SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
+ last(/Cisco IOS by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
or
- last(/Cisco IOS SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
- recovery_expression: 'max(/Cisco IOS SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
+ last(/Cisco IOS by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
+ recovery_expression: 'max(/Cisco IOS by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
tags:
-
tag: scope
@@ -2582,7 +1615,7 @@ zabbix_export:
type: GRAPH_PROTOTYPE
name: graphid
value:
- host: 'Cisco IOS SNMP'
+ host: 'Cisco IOS by SNMP'
name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
valuemaps:
-
@@ -3528,9 +2561,976 @@ zabbix_export:
value: '2'
newvalue: unknown
-
+ uuid: 1bb42fbdb9054645a62ff81f14ba3b99
+ template: 'Cisco IOS prior to 12.0_3_T by SNMP'
+ name: 'Cisco IOS prior to 12.0_3_T by SNMP'
+ description: |
+ Cisco IOS Software releases prior to 12.0(3)T
+
+ MIBs used:
+ HOST-RESOURCES-MIB
+ SNMPv2-MIB
+ OLD-CISCO-CPU-MIB
+ CISCO-ENVMON-MIB
+ CISCO-MEMORY-POOL-MIB
+ ENTITY-MIB
+
+ Template tooling version used: 0.42
+ groups:
+ -
+ name: 'Templates/Network devices'
+ items:
+ -
+ uuid: bf6d81068770410a929c127d8e7d76c1
+ name: 'ICMP ping'
+ type: SIMPLE
+ key: icmpping
+ history: 1w
+ valuemap:
+ name: 'Service state'
+ tags:
+ -
+ tag: component
+ value: health
+ -
+ tag: component
+ value: network
+ triggers:
+ -
+ uuid: fd317d3e8d3d45bf97322b8578f30c04
+ expression: 'max(/Cisco IOS prior to 12.0_3_T by SNMP/icmpping,#3)=0'
+ name: 'Unavailable by ICMP ping'
+ priority: HIGH
+ description: 'Last three attempts returned timeout. Please check device connectivity.'
+ tags:
+ -
+ tag: scope
+ value: availability
+ -
+ uuid: 2af7b5f79fc44d7d992b0bf6277c12bb
+ name: 'ICMP loss'
+ type: SIMPLE
+ key: icmppingloss
+ history: 1w
+ value_type: FLOAT
+ units: '%'
+ tags:
+ -
+ tag: component
+ value: health
+ -
+ tag: component
+ value: network
+ triggers:
+ -
+ uuid: 3576c96601ef40abbeedbde11768141a
+ expression: 'min(/Cisco IOS prior to 12.0_3_T by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS prior to 12.0_3_T by SNMP/icmppingloss,5m)<100'
+ name: 'High ICMP ping loss'
+ opdata: 'Loss: {ITEM.LASTVALUE1}'
+ priority: WARNING
+ dependencies:
+ -
+ name: 'Unavailable by ICMP ping'
+ expression: 'max(/Cisco IOS prior to 12.0_3_T by SNMP/icmpping,#3)=0'
+ tags:
+ -
+ tag: scope
+ value: availability
+ -
+ tag: scope
+ value: performance
+ -
+ uuid: 1afa1e8ca21c430598845806bbf0e7a2
+ name: 'ICMP response time'
+ type: SIMPLE
+ key: icmppingsec
+ history: 1w
+ value_type: FLOAT
+ units: s
+ tags:
+ -
+ tag: component
+ value: health
+ -
+ tag: component
+ value: network
+ triggers:
+ -
+ uuid: 2941d30058b14d52bd9a723889c8be26
+ expression: 'avg(/Cisco IOS prior to 12.0_3_T by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
+ name: 'High ICMP ping response time'
+ opdata: 'Value: {ITEM.LASTVALUE1}'
+ priority: WARNING
+ dependencies:
+ -
+ name: 'High ICMP ping loss'
+ expression: 'min(/Cisco IOS prior to 12.0_3_T by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS prior to 12.0_3_T by SNMP/icmppingloss,5m)<100'
+ -
+ name: 'Unavailable by ICMP ping'
+ expression: 'max(/Cisco IOS prior to 12.0_3_T by SNMP/icmpping,#3)=0'
+ tags:
+ -
+ tag: scope
+ value: availability
+ -
+ tag: scope
+ value: performance
+ -
+ uuid: 53eb0288c9e54490942cedd4ce5f376e
+ name: 'SNMP traps (fallback)'
+ type: SNMP_TRAP
+ key: snmptrap.fallback
+ history: 2w
+ trends: '0'
+ value_type: LOG
+ description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items'
+ logtimefmt: 'hh:mm:sszyyyy/MM/dd'
+ tags:
+ -
+ tag: component
+ value: network
+ -
+ uuid: bba5be8b3fa54bfbb354b7a2c20fd353
+ name: 'System contact details'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.2.1.1.4.0
+ key: 'system.contact[sysContact.0]'
+ delay: 15m
+ history: 2w
+ trends: '0'
+ value_type: CHAR
+ description: |
+ MIB: SNMPv2-MIB
+ The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
+ inventory_link: CONTACT
+ preprocessing:
+ -
+ type: DISCARD_UNCHANGED_HEARTBEAT
+ parameters:
+ - 12h
+ tags:
+ -
+ tag: component
+ value: system
+ -
+ uuid: 693b0c779f574d869f47b44c4b3ecd58
+ name: 'CPU utilization'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.4.1.9.2.1.58
+ key: 'system.cpu.util[avgBusy5]'
+ delay: 5m
+ history: 7d
+ value_type: FLOAT
+ units: '%'
+ description: |
+ MIB: OLD-CISCO-CPU-MIB
+ 5 minute exponentially-decayed moving average of the CPU busy percentage.
+ Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15215-collect-cpu-util-snmp.html
+ tags:
+ -
+ tag: component
+ value: cpu
+ triggers:
+ -
+ uuid: 74773fc279864e7daf89cffe9cb2067c
+ expression: 'min(/Cisco IOS prior to 12.0_3_T by SNMP/system.cpu.util[avgBusy5],5m)>{$CPU.UTIL.CRIT}'
+ name: 'High CPU utilization'
+ event_name: 'High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
+ opdata: 'Current utilization: {ITEM.LASTVALUE1}'
+ priority: WARNING
+ description: 'CPU utilization is too high. The system might be slow to respond.'
+ tags:
+ -
+ tag: scope
+ value: performance
+ -
+ uuid: 495b26e876a04819a02cf22eaba04e0b
+ name: 'System description'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.2.1.1.1.0
+ key: 'system.descr[sysDescr.0]'
+ delay: 15m
+ history: 2w
+ trends: '0'
+ value_type: CHAR
+ description: |
+ MIB: SNMPv2-MIB
+ A textual description of the entity. This value should
+ include the full name and version identification of the system's hardware type, software operating-system, and
+ networking software.
+ preprocessing:
+ -
+ type: DISCARD_UNCHANGED_HEARTBEAT
+ parameters:
+ - 12h
+ tags:
+ -
+ tag: component
+ value: system
+ -
+ uuid: b5121a382d0245f0906bba4530a82ac4
+ name: 'Hardware model name'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.13.1
+ key: system.hw.model
+ delay: 1h
+ history: 2w
+ trends: '0'
+ value_type: CHAR
+ description: 'MIB: ENTITY-MIB'
+ inventory_link: MODEL
+ preprocessing:
+ -
+ type: DISCARD_UNCHANGED_HEARTBEAT
+ parameters:
+ - 1d
+ tags:
+ -
+ tag: component
+ value: system
+ -
+ uuid: 5934a35b54464f66ab19152ca393b882
+ name: 'Hardware serial number'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.2.1.47.1.1.1.1.11.1
+ key: system.hw.serialnumber
+ delay: 1h
+ history: 2w
+ trends: '0'
+ value_type: CHAR
+ description: 'MIB: ENTITY-MIB'
+ inventory_link: SERIALNO_A
+ preprocessing:
+ -
+ type: DISCARD_UNCHANGED_HEARTBEAT
+ parameters:
+ - 1d
+ tags:
+ -
+ tag: component
+ value: system
+ triggers:
+ -
+ uuid: d53c0d22a67544cf8a2fcd2c8de4d4eb
+ expression: 'last(/Cisco IOS prior to 12.0_3_T by SNMP/system.hw.serialnumber,#1)<>last(/Cisco IOS prior to 12.0_3_T by SNMP/system.hw.serialnumber,#2) and length(last(/Cisco IOS prior to 12.0_3_T by SNMP/system.hw.serialnumber))>0'
+ name: 'Device has been replaced'
+ event_name: 'Device has been replaced (new serial number received)'
+ priority: INFO
+ description: 'Device serial number has changed. Ack to close'
+ manual_close: 'YES'
+ tags:
+ -
+ tag: scope
+ value: notice
+ -
+ uuid: 732ccfd809b44d7fa923c54e6577851d
+ name: 'Uptime (hardware)'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.2.1.25.1.1.0
+ key: 'system.hw.uptime[hrSystemUptime.0]'
+ delay: 30s
+ history: 2w
+ trends: 0d
+ units: uptime
+ description: |
+ MIB: HOST-RESOURCES-MIB
+ The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.
+ preprocessing:
+ -
+ type: CHECK_NOT_SUPPORTED
+ parameters:
+ - ''
+ error_handler: CUSTOM_VALUE
+ error_handler_params: '0'
+ -
+ type: MULTIPLIER
+ parameters:
+ - '0.01'
+ tags:
+ -
+ tag: component
+ value: system
+ -
+ uuid: 30df666e80bd4875ac761306781061da
+ name: 'System location'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.2.1.1.6.0
+ key: 'system.location[sysLocation.0]'
+ delay: 15m
+ history: 2w
+ trends: '0'
+ value_type: CHAR
+ description: |
+ MIB: SNMPv2-MIB
+ The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.
+ inventory_link: LOCATION
+ preprocessing:
+ -
+ type: DISCARD_UNCHANGED_HEARTBEAT
+ parameters:
+ - 12h
+ tags:
+ -
+ tag: component
+ value: system
+ -
+ uuid: 2e55e75a7baa4195b012e750bac90dcb
+ name: 'System name'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.2.1.1.5.0
+ key: system.name
+ delay: 15m
+ history: 2w
+ trends: '0'
+ value_type: CHAR
+ description: |
+ MIB: SNMPv2-MIB
+ An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
+ inventory_link: NAME
+ preprocessing:
+ -
+ type: DISCARD_UNCHANGED_HEARTBEAT
+ parameters:
+ - 12h
+ tags:
+ -
+ tag: component
+ value: system
+ triggers:
+ -
+ uuid: 33b42b1aa448408fa3fb5aadf7375cf8
+ expression: 'last(/Cisco IOS prior to 12.0_3_T by SNMP/system.name,#1)<>last(/Cisco IOS prior to 12.0_3_T by SNMP/system.name,#2) and length(last(/Cisco IOS prior to 12.0_3_T by SNMP/system.name))>0'
+ name: 'System name has changed'
+ event_name: 'System name has changed (new name: {ITEM.VALUE})'
+ priority: INFO
+ description: 'System name has changed. Ack to close.'
+ manual_close: 'YES'
+ tags:
+ -
+ tag: scope
+ value: notice
+ -
+ tag: scope
+ value: security
+ -
+ uuid: 7ecd28b73c0f43a98c3a58467b1cbdc7
+ name: 'Uptime (network)'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.2.1.1.3.0
+ key: 'system.net.uptime[sysUpTime.0]'
+ delay: 30s
+ history: 2w
+ trends: 0d
+ units: uptime
+ description: |
+ MIB: SNMPv2-MIB
+ The time (in hundredths of a second) since the network management portion of the system was last re-initialized.
+ preprocessing:
+ -
+ type: MULTIPLIER
+ parameters:
+ - '0.01'
+ tags:
+ -
+ tag: component
+ value: system
+ -
+ uuid: cc6e5a6e4f604b639815d9397264c6af
+ name: 'System object ID'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.2.1.1.2.0
+ key: 'system.objectid[sysObjectID.0]'
+ delay: 15m
+ history: 2w
+ trends: '0'
+ value_type: CHAR
+ description: |
+ MIB: SNMPv2-MIB
+ The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
+ preprocessing:
+ -
+ type: DISCARD_UNCHANGED_HEARTBEAT
+ parameters:
+ - 12h
+ tags:
+ -
+ tag: component
+ value: system
+ -
+ uuid: 70ef7ce7561640b7bc6b5d30235c0ecc
+ name: 'Operating system'
+ type: SNMP_AGENT
+ snmp_oid: 1.3.6.1.2.1.1.1.0
+ key: 'system.sw.os[sysDescr.0]'
+ delay: 1h
+ history: 2w
+ trends: '0'
+ value_type: CHAR
+ description: 'MIB: SNMPv2-MIB'
+ inventory_link: OS
+ preprocessing:
+ -
+ type: REGEX
+ parameters:
+ - 'Version (.+), RELEASE'
+ - \1
+ -
+ type: DISCARD_UNCHANGED_HEARTBEAT
+ parameters:
+ - 1d
+ tags:
+ -
+ tag: component
+ value: os
+ triggers:
+ -
+ uuid: abe57415ff574b878a2ce2a318be86ee
+ expression: 'last(/Cisco IOS prior to 12.0_3_T by SNMP/system.sw.os[sysDescr.0],#1)<>last(/Cisco IOS prior to 12.0_3_T by SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Cisco IOS prior to 12.0_3_T by SNMP/system.sw.os[sysDescr.0]))>0'
+ name: 'Operating system description has changed'
+ priority: INFO
+ description: 'Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.'
+ manual_close: 'YES'
+ dependencies:
+ -
+ name: 'System name has changed'
+ expression: 'last(/Cisco IOS prior to 12.0_3_T by SNMP/system.name,#1)<>last(/Cisco IOS prior to 12.0_3_T by SNMP/system.name,#2) and length(last(/Cisco IOS prior to 12.0_3_T by SNMP/system.name))>0'
+ tags:
+ -
+ tag: scope
+ value: notice
+ -
+ uuid: 5a156e9ca10c49bbb87cf3de1b686cff
+ name: 'SNMP agent availability'
+ type: INTERNAL
+ key: 'zabbix[host,snmp,available]'
+ history: 7d
+ description: |
+ Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
+ Possible value:
+ 0 - not available
+ 1 - available
+ 2 - unknown
+ valuemap:
+ name: zabbix.host.available
+ tags:
+ -
+ tag: component
+ value: health
+ -
+ tag: component
+ value: network
+ triggers:
+ -
+ uuid: 86d8603903504287b07a25530c8eda2b
+ expression: 'max(/Cisco IOS prior to 12.0_3_T by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
+ name: 'No SNMP data collection'
+ opdata: 'Current state: {ITEM.LASTVALUE1}'
+ priority: WARNING
+ description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
+ dependencies:
+ -
+ name: 'Unavailable by ICMP ping'
+ expression: 'max(/Cisco IOS prior to 12.0_3_T by SNMP/icmpping,#3)=0'
+ tags:
+ -
+ tag: scope
+ value: availability
+ discovery_rules:
+ -
+ uuid: fbeef9c16d9d45b7a5c50f530a697f76
+ name: 'Entity Serial Numbers Discovery'
+ type: SNMP_AGENT
+ snmp_oid: 'discovery[{#ENT_CLASS},1.3.6.1.2.1.47.1.1.1.1.5,{#ENT_NAME},1.3.6.1.2.1.47.1.1.1.1.7,{#ENT_SN},1.3.6.1.2.1.47.1.1.1.1.11]'
+ key: entity_sn.discovery
+ delay: 1h
+ filter:
+ evaltype: AND
+ conditions:
+ -
+ macro: '{#ENT_SN}'
+ value: .+
+ formulaid: B
+ -
+ macro: '{#ENT_CLASS}'
+ value: ^3$
+ formulaid: A
+ item_prototypes:
+ -
+ uuid: 1993495d289d407e85c24f4986819ab8
+ name: '{#ENT_NAME}: Hardware serial number'
+ type: SNMP_AGENT
+ snmp_oid: '1.3.6.1.2.1.47.1.1.1.1.11.{#SNMPINDEX}'
+ key: 'system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]'
+ delay: 1h
+ history: 2w
+ trends: '0'
+ value_type: CHAR
+ description: 'MIB: ENTITY-MIB'
+ preprocessing:
+ -
+ type: DISCARD_UNCHANGED_HEARTBEAT
+ parameters:
+ - 1d
+ tags:
+ -
+ tag: component
+ value: system
+ trigger_prototypes:
+ -
+ uuid: e8c328ad70a146219a8ae62f101cfc00
+ expression: 'last(/Cisco IOS prior to 12.0_3_T by SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#1)<>last(/Cisco IOS prior to 12.0_3_T by SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#2) and length(last(/Cisco IOS prior to 12.0_3_T by SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]))>0'
+ name: '{#ENT_NAME}: Device has been replaced'
+ event_name: '{#ENT_NAME}: Device has been replaced (new serial number received)'
+ priority: INFO
+ description: 'Device serial number has changed. Ack to close'
+ manual_close: 'YES'
+ tags:
+ -
+ tag: scope
+ value: notice
+ -
+ uuid: 109cd000cd044e4096bf98dbf57b72d1
+ name: 'FAN Discovery'
+ type: SNMP_AGENT
+ snmp_oid: 'discovery[{#SENSOR_INFO},1.3.6.1.4.1.9.9.13.1.4.1.2]'
+ key: fan.discovery
+ delay: 1h
+ description: 'The table of fan status maintained by the environmental monitor.'
+ item_prototypes:
+ -
+ uuid: 7008cccccf2647918bce95bb0a6193df
+ name: '{#SENSOR_INFO}: Fan status'
+ type: SNMP_AGENT
+ snmp_oid: '1.3.6.1.4.1.9.9.13.1.4.1.3.{#SNMPINDEX}'
+ key: 'sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}]'
+ delay: 3m
+ history: 2w
+ trends: 0d
+ description: 'MIB: CISCO-ENVMON-MIB'
+ valuemap:
+ name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
+ tags:
+ -
+ tag: component
+ value: fan
+ trigger_prototypes:
+ -
+ uuid: ddd7015dd3204514beea29edc45c3cd4
+ expression: 'count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
+ name: '{#SENSOR_INFO}: Fan is in critical state'
+ opdata: 'Current state: {ITEM.LASTVALUE1}'
+ priority: AVERAGE
+ description: 'Please check the fan unit'
+ tags:
+ -
+ tag: scope
+ value: availability
+ -
+ tag: scope
+ value: performance
+ -
+ uuid: 4eb7ea3405d74740a12095a07d91d48f
+ expression: 'count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"notFunctioning\"}")=1'
+ name: '{#SENSOR_INFO}: Fan is in warning state'
+ opdata: 'Current state: {ITEM.LASTVALUE1}'
+ priority: WARNING
+ description: 'Please check the fan unit'
+ dependencies:
+ -
+ name: '{#SENSOR_INFO}: Fan is in critical state'
+ expression: 'count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
+ tags:
+ -
+ tag: scope
+ value: availability
+ -
+ tag: scope
+ value: performance
+ -
+ uuid: 727adcf658d141ff9e45744107a58c38
+ name: 'Memory Discovery'
+ type: SNMP_AGENT
+ snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.48.1.1.1.2]'
+ key: memory.discovery
+ delay: 1h
+ description: |
+ Discovery of ciscoMemoryPoolTable, a table of memory pool monitoring entries.
+ http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
+ item_prototypes:
+ -
+ uuid: e0df9d6e31384da4af18ab191e467814
+ name: '{#SNMPVALUE}: Free memory'
+ type: SNMP_AGENT
+ snmp_oid: '1.3.6.1.4.1.9.9.48.1.1.1.6.{#SNMPINDEX}'
+ key: 'vm.memory.free[ciscoMemoryPoolFree.{#SNMPINDEX}]'
+ history: 7d
+ units: B
+ description: |
+ MIB: CISCO-MEMORY-POOL-MIB
+ Indicates the number of bytes from the memory pool that are currently unused on the managed device. Note that the sum of ciscoMemoryPoolUsed and ciscoMemoryPoolFree is the total amount of memory in the pool
+ Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
+ tags:
+ -
+ tag: component
+ value: memory
+ -
+ uuid: 25471f4acc4348bf978792fcfaff6acc
+ name: '{#SNMPVALUE}: Used memory'
+ type: SNMP_AGENT
+ snmp_oid: '1.3.6.1.4.1.9.9.48.1.1.1.5.{#SNMPINDEX}'
+ key: 'vm.memory.used[ciscoMemoryPoolUsed.{#SNMPINDEX}]'
+ history: 7d
+ units: B
+ description: |
+ MIB: CISCO-MEMORY-POOL-MIB
+ Indicates the number of bytes from the memory pool that are currently in use by applications on the managed device.
+ Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
+ tags:
+ -
+ tag: component
+ value: memory
+ -
+ uuid: 9a03c1b1c6ae42e5ab1886c172b2e3ac
+ name: '{#SNMPVALUE}: Memory utilization'
+ type: CALCULATED
+ key: 'vm.memory.util[vm.memory.util.{#SNMPINDEX}]'
+ history: 7d
+ value_type: FLOAT
+ units: '%'
+ params: 'last(//vm.memory.used[ciscoMemoryPoolUsed.{#SNMPINDEX}])/(last(//vm.memory.free[ciscoMemoryPoolFree.{#SNMPINDEX}])+last(//vm.memory.used[ciscoMemoryPoolUsed.{#SNMPINDEX}]))*100'
+ description: 'Memory utilization in %.'
+ tags:
+ -
+ tag: component
+ value: memory
+ trigger_prototypes:
+ -
+ uuid: 8793ba7767cc415a80a6a206aaf01f11
+ expression: 'min(/Cisco IOS prior to 12.0_3_T by SNMP/vm.memory.util[vm.memory.util.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
+ name: '{#SNMPVALUE}: High memory utilization'
+ event_name: '{#SNMPVALUE}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
+ priority: AVERAGE
+ description: 'The system is running out of free memory.'
+ tags:
+ -
+ tag: scope
+ value: capacity
+ -
+ tag: scope
+ value: performance
+ graph_prototypes:
+ -
+ uuid: dd0520d162fe4230900d33472944677f
+ name: '{#SNMPVALUE}: Memory utilization'
+ ymin_type_1: FIXED
+ ymax_type_1: FIXED
+ graph_items:
+ -
+ drawtype: GRADIENT_LINE
+ color: 1A7C11
+ item:
+ host: 'Cisco IOS prior to 12.0_3_T by SNMP'
+ key: 'vm.memory.util[vm.memory.util.{#SNMPINDEX}]'
+ -
+ uuid: 5e67e9c84ac54dea866893207a42d3e3
+ name: 'PSU Discovery'
+ type: SNMP_AGENT
+ snmp_oid: 'discovery[{#SENSOR_INFO},1.3.6.1.4.1.9.9.13.1.5.1.2]'
+ key: psu.discovery
+ delay: 1h
+ description: 'The table of power supply status maintained by the environmental monitor card.'
+ item_prototypes:
+ -
+ uuid: d05d99a68e3540d09d64b8bab5d63004
+ name: '{#SENSOR_INFO}: Power supply status'
+ type: SNMP_AGENT
+ snmp_oid: '1.3.6.1.4.1.9.9.13.1.5.1.3.{#SNMPINDEX}'
+ key: 'sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}]'
+ delay: 3m
+ history: 2w
+ trends: 0d
+ description: 'MIB: CISCO-ENVMON-MIB'
+ valuemap:
+ name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
+ tags:
+ -
+ tag: component
+ value: power
+ trigger_prototypes:
+ -
+ uuid: fc4b6f155d3646c3bb8b27d35c18604b
+ expression: 'count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
+ name: '{#SENSOR_INFO}: Power supply is in critical state'
+ opdata: 'Current state: {ITEM.LASTVALUE1}'
+ priority: AVERAGE
+ description: 'Please check the power supply unit for errors'
+ tags:
+ -
+ tag: scope
+ value: availability
+ -
+ tag: scope
+ value: performance
+ -
+ uuid: 58e9514d75f84c989b052cfd76ceed4a
+ expression: 'count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"notFunctioning\"}")=1'
+ name: '{#SENSOR_INFO}: Power supply is in warning state'
+ opdata: 'Current state: {ITEM.LASTVALUE1}'
+ priority: WARNING
+ description: 'Please check the power supply unit for errors'
+ dependencies:
+ -
+ name: '{#SENSOR_INFO}: Power supply is in critical state'
+ expression: 'count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
+ tags:
+ -
+ tag: scope
+ value: availability
+ -
+ tag: scope
+ value: performance
+ -
+ uuid: 73d10f48886443248f7d2d9167fcfee5
+ name: 'Temperature Discovery'
+ type: SNMP_AGENT
+ snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.3.1.2]'
+ key: temperature.discovery
+ delay: 1h
+ description: |
+ Discovery of ciscoEnvMonTemperatureTable (ciscoEnvMonTemperatureDescr), a table of ambient temperature status
+ maintained by the environmental monitor.
+ item_prototypes:
+ -
+ uuid: a12075ae5b834eeeb742fed6f7afc39d
+ name: '{#SNMPVALUE}: Temperature status'
+ type: SNMP_AGENT
+ snmp_oid: '1.3.6.1.4.1.9.9.13.1.3.1.6.{#SNMPINDEX}'
+ key: 'sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}]'
+ delay: 3m
+ history: 2w
+ trends: 0d
+ description: |
+ MIB: CISCO-ENVMON-MIB
+ The current state of the test point being instrumented.
+ valuemap:
+ name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
+ tags:
+ -
+ tag: component
+ value: temperature
+ -
+ uuid: ea0d56dd49104257ba6c14ce3bdb753a
+ name: '{#SNMPVALUE}: Temperature'
+ type: SNMP_AGENT
+ snmp_oid: '1.3.6.1.4.1.9.9.13.1.3.1.3.{#SNMPINDEX}'
+ key: 'sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}]'
+ delay: 3m
+ value_type: FLOAT
+ units: °C
+ description: |
+ MIB: CISCO-ENVMON-MIB
+ The current measurement of the test point being instrumented.
+ tags:
+ -
+ tag: component
+ value: temperature
+ trigger_prototypes:
+ -
+ uuid: 716dee103c9f4e9da5f83d6cc338617d
+ expression: 'avg(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
+ recovery_mode: RECOVERY_EXPRESSION
+ recovery_expression: 'min(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
+ name: '{#SNMPVALUE}: Temperature is too low'
+ event_name: '{#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
+ opdata: 'Current value: {ITEM.LASTVALUE1}'
+ priority: AVERAGE
+ tags:
+ -
+ tag: scope
+ value: availability
+ -
+ tag: scope
+ value: performance
+ trigger_prototypes:
+ -
+ uuid: 82fa9473dc7d49d4a3a230ef6238cd2c
+ expression: |
+ avg(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
+ or
+ last(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
+ or
+ last(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
+ recovery_mode: RECOVERY_EXPRESSION
+ recovery_expression: 'max(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
+ name: '{#SNMPVALUE}: Temperature is above critical threshold'
+ event_name: '{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}'
+ opdata: 'Current value: {ITEM.LASTVALUE1}'
+ priority: HIGH
+ description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
+ tags:
+ -
+ tag: scope
+ value: availability
+ -
+ tag: scope
+ value: performance
+ -
+ uuid: a0199088767f43c0990f5ac8793267b1
+ expression: |
+ avg(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}
+ or
+ last(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_WARN_STATUS}
+ recovery_mode: RECOVERY_EXPRESSION
+ recovery_expression: 'max(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
+ name: '{#SNMPVALUE}: Temperature is above warning threshold'
+ event_name: '{#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}'
+ opdata: 'Current value: {ITEM.LASTVALUE1}'
+ priority: WARNING
+ description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
+ dependencies:
+ -
+ name: '{#SNMPVALUE}: Temperature is above critical threshold'
+ expression: |
+ avg(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
+ or
+ last(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
+ or
+ last(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
+ recovery_expression: 'max(/Cisco IOS prior to 12.0_3_T by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
+ tags:
+ -
+ tag: scope
+ value: availability
+ -
+ tag: scope
+ value: performance
+ tags:
+ -
+ tag: class
+ value: network
+ -
+ tag: target
+ value: cisco
+ -
+ tag: target
+ value: cisco-prior
+ -
+ tag: target
+ value: cisco-prior-12.0-3-t
+ macros:
+ -
+ macro: '{$CPU.UTIL.CRIT}'
+ value: '90'
+ -
+ macro: '{$FAN_CRIT_STATUS:"critical"}'
+ value: '3'
+ -
+ macro: '{$FAN_CRIT_STATUS:"shutdown"}'
+ value: '4'
+ -
+ macro: '{$FAN_WARN_STATUS:"notFunctioning"}'
+ value: '6'
+ -
+ macro: '{$FAN_WARN_STATUS:"warning"}'
+ value: '2'
+ -
+ macro: '{$ICMP_LOSS_WARN}'
+ value: '20'
+ -
+ macro: '{$ICMP_RESPONSE_TIME_WARN}'
+ value: '0.15'
+ -
+ macro: '{$MEMORY.UTIL.MAX}'
+ value: '90'
+ -
+ macro: '{$PSU_CRIT_STATUS:"critical"}'
+ value: '3'
+ -
+ macro: '{$PSU_CRIT_STATUS:"shutdown"}'
+ value: '4'
+ -
+ macro: '{$PSU_WARN_STATUS:"notFunctioning"}'
+ value: '6'
+ -
+ macro: '{$PSU_WARN_STATUS:"warning"}'
+ value: '2'
+ -
+ macro: '{$SNMP.TIMEOUT}'
+ value: 5m
+ -
+ macro: '{$TEMP_CRIT}'
+ value: '60'
+ -
+ macro: '{$TEMP_CRIT:"CPU"}'
+ value: '75'
+ -
+ macro: '{$TEMP_CRIT_LOW}'
+ value: '5'
+ -
+ macro: '{$TEMP_CRIT_STATUS}'
+ value: '3'
+ -
+ macro: '{$TEMP_DISASTER_STATUS}'
+ value: '4'
+ -
+ macro: '{$TEMP_WARN}'
+ value: '50'
+ -
+ macro: '{$TEMP_WARN:"CPU"}'
+ value: '70'
+ -
+ macro: '{$TEMP_WARN_STATUS}'
+ value: '2'
+ valuemaps:
+ -
+ uuid: 0e5588b6aa714283b436031ff8ebc93a
+ name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
+ mappings:
+ -
+ value: '1'
+ newvalue: normal
+ -
+ value: '2'
+ newvalue: warning
+ -
+ value: '3'
+ newvalue: critical
+ -
+ value: '4'
+ newvalue: shutdown
+ -
+ value: '5'
+ newvalue: notPresent
+ -
+ value: '6'
+ newvalue: notFunctioning
+ -
+ uuid: 9fc9d3c2eb254de996d9c4a61ba58671
+ name: 'Service state'
+ mappings:
+ -
+ value: '0'
+ newvalue: Down
+ -
+ value: '1'
+ newvalue: Up
+ -
+ uuid: bb13061dd5b542f9b0f5921e75866679
+ name: zabbix.host.available
+ mappings:
+ -
+ value: '0'
+ newvalue: 'not available'
+ -
+ value: '1'
+ newvalue: available
+ -
+ value: '2'
+ newvalue: unknown
+ -
uuid: 40c233aaa3424fd29dc378022ff3461d
- template: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
- name: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
+ template: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
+ name: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
description: |
Cisco IOS Software releases later to 12.0(3)T and prior to 12.2(3.5)
@@ -3566,7 +3566,7 @@ zabbix_export:
triggers:
-
uuid: f6fae61d08644d5fa3929f526aee34e4
- expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/icmpping,#3)=0'
+ expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/icmpping,#3)=0'
name: 'Unavailable by ICMP ping'
priority: HIGH
description: 'Last three attempts returned timeout. Please check device connectivity.'
@@ -3592,14 +3592,14 @@ zabbix_export:
triggers:
-
uuid: 5c7eae9701be4661a34bbcdb99c094fe
- expression: 'min(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/icmppingloss,5m)<100'
+ expression: 'min(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/icmppingloss,5m)<100'
name: 'High ICMP ping loss'
opdata: 'Loss: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'Unavailable by ICMP ping'
- expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/icmpping,#3)=0'
+ expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/icmpping,#3)=0'
tags:
-
tag: scope
@@ -3625,17 +3625,17 @@ zabbix_export:
triggers:
-
uuid: 9aebe4a1cfa34c5d92178abc8a6ce06e
- expression: 'avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
+ expression: 'avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
name: 'High ICMP ping response time'
opdata: 'Value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'High ICMP ping loss'
- expression: 'min(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/icmppingloss,5m)<100'
+ expression: 'min(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/icmppingloss,5m)<100'
-
name: 'Unavailable by ICMP ping'
- expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/icmpping,#3)=0'
+ expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/icmpping,#3)=0'
tags:
-
tag: scope
@@ -3749,7 +3749,7 @@ zabbix_export:
triggers:
-
uuid: 78723249679b4a288861f4ad8621fd77
- expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.hw.serialnumber,#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.hw.serialnumber,#2) and length(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.hw.serialnumber))>0'
+ expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.hw.serialnumber,#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.hw.serialnumber,#2) and length(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.hw.serialnumber))>0'
name: 'Device has been replaced'
event_name: 'Device has been replaced (new serial number received)'
priority: INFO
@@ -3836,7 +3836,7 @@ zabbix_export:
triggers:
-
uuid: 3e09d5d308e449a4974393650b33e64d
- expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.name,#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.name,#2) and length(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.name))>0'
+ expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.name,#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.name,#2) and length(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.name))>0'
name: 'System name has changed'
event_name: 'System name has changed (new name: {ITEM.VALUE})'
priority: INFO
@@ -3922,7 +3922,7 @@ zabbix_export:
triggers:
-
uuid: df85813bb6af4accab8d5191cd452329
- expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.sw.os[sysDescr.0],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.sw.os[sysDescr.0]))>0'
+ expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.sw.os[sysDescr.0],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.sw.os[sysDescr.0],#2) and length(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.sw.os[sysDescr.0]))>0'
name: 'Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.'
@@ -3930,7 +3930,7 @@ zabbix_export:
dependencies:
-
name: 'System name has changed'
- expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.name,#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.name,#2) and length(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.name))>0'
+ expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.name,#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.name,#2) and length(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.name))>0'
tags:
-
tag: scope
@@ -3959,7 +3959,7 @@ zabbix_export:
triggers:
-
uuid: 778749b260bb45c3a926d6bb49c07257
- expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
+ expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
name: 'No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
@@ -3967,7 +3967,7 @@ zabbix_export:
dependencies:
-
name: 'Unavailable by ICMP ping'
- expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/icmpping,#3)=0'
+ expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/icmpping,#3)=0'
tags:
-
tag: scope
@@ -4012,7 +4012,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: b964834d4f6549c7ae0f0c0c2646dfbc
- expression: 'min(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.cpu.util[cpmCPUTotal5min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
+ expression: 'min(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.cpu.util[cpmCPUTotal5min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
name: '{#SNMPVALUE}: High CPU utilization'
event_name: '{#SNMPVALUE}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
opdata: 'Current utilization: {ITEM.LASTVALUE1}'
@@ -4033,7 +4033,7 @@ zabbix_export:
drawtype: GRADIENT_LINE
color: 1A7C11
item:
- host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
+ host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
key: 'system.cpu.util[cpmCPUTotal5min.{#SNMPINDEX}]'
-
uuid: afafbf551dc242e8a85dbb12ba1aa067
@@ -4077,7 +4077,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 75ee6ab1f0c84946a4f4d6e87007ec25
- expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#2) and length(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]))>0'
+ expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#2) and length(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]))>0'
name: '{#ENT_NAME}: Device has been replaced'
event_name: '{#ENT_NAME}: Device has been replaced (new serial number received)'
priority: INFO
@@ -4115,7 +4115,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 907502bbdeee45bbbfb84d43c2dc4f20
- expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
+ expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
name: '{#SENSOR_INFO}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
@@ -4129,7 +4129,7 @@ zabbix_export:
value: performance
-
uuid: 4b2a4eb4cb2a43758048cc05d63f37a4
- expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"notFunctioning\"}")=1'
+ expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"notFunctioning\"}")=1'
name: '{#SENSOR_INFO}: Fan is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
@@ -4137,7 +4137,7 @@ zabbix_export:
dependencies:
-
name: '{#SENSOR_INFO}: Fan is in critical state'
- expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
+ expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.fan.status[ciscoEnvMonFanState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"shutdown\"}")=1'
tags:
-
tag: scope
@@ -4205,7 +4205,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 0f8d70ef5e704483a49d7b635e74dfc6
- expression: 'min(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/vm.memory.util[vm.memory.util.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
+ expression: 'min(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/vm.memory.util[vm.memory.util.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
name: '{#SNMPVALUE}: High memory utilization'
event_name: '{#SNMPVALUE}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
priority: AVERAGE
@@ -4228,7 +4228,7 @@ zabbix_export:
drawtype: GRADIENT_LINE
color: 1A7C11
item:
- host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
+ host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
key: 'vm.memory.util[vm.memory.util.{#SNMPINDEX}]'
-
uuid: 328da4bee6ea49aa8809cdbb74744263
@@ -4534,9 +4534,9 @@ zabbix_export:
trigger_prototypes:
-
uuid: c99f0efcc30749e79cce0efe2fdd574f
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ recovery_expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
@@ -4587,21 +4587,21 @@ zabbix_export:
-
uuid: 60809b6c94d74e34b5f29525d77c75b5
expression: |
- change(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
+ change(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
and (
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.type[ifType.{#SNMPINDEX}])=117
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117
)
and
- (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)
+ (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
- (change(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or
- (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)
+ (change(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or
+ (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)
name: 'Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before'
opdata: 'Current reported speed: {ITEM.LASTVALUE1}'
priority: INFO
@@ -4610,8 +4610,8 @@ zabbix_export:
dependencies:
-
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
- recovery_expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ recovery_expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
-
tag: scope
@@ -4619,13 +4619,13 @@ zabbix_export:
-
uuid: 21d475be7fa24ba2b946e4ec31371df5
expression: |
- (avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or
- avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
+ (avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or
+ avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
- avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and
- avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])
+ avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and
+ avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])
name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage'
event_name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage (>{$IF.UTIL.MAX:"{#IFNAME}"}%)'
opdata: 'In: {ITEM.LASTVALUE1}, out: {ITEM.LASTVALUE3}, speed: {ITEM.LASTVALUE2}'
@@ -4635,8 +4635,8 @@ zabbix_export:
dependencies:
-
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
- recovery_expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ recovery_expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
-
tag: scope
@@ -4644,12 +4644,12 @@ zabbix_export:
-
uuid: 5a2bc4c9bf344948a52ce256daa1258e
expression: |
- min(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
- or min(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
+ min(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
+ or min(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
- max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
- and max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
+ max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
+ and max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
name: 'Interface {#IFNAME}({#IFALIAS}): High error rate'
event_name: 'Interface {#IFNAME}({#IFALIAS}): High error rate (>{$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)'
opdata: 'errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}'
@@ -4659,8 +4659,8 @@ zabbix_export:
dependencies:
-
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
- recovery_expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ recovery_expression: 'last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
-
tag: scope
@@ -4677,42 +4677,42 @@ zabbix_export:
drawtype: GRADIENT_LINE
color: 1A7C11
item:
- host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
+ host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]'
-
sortorder: '1'
drawtype: BOLD_LINE
color: 2774A4
item:
- host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
+ host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]'
-
sortorder: '2'
color: F63100
yaxisside: RIGHT
item:
- host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
+ host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]'
-
sortorder: '3'
color: A54F10
yaxisside: RIGHT
item:
- host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
+ host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]'
-
sortorder: '4'
color: FC6EA3
yaxisside: RIGHT
item:
- host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
+ host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]'
-
sortorder: '5'
color: 6C59DC
yaxisside: RIGHT
item:
- host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
+ host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]'
-
uuid: 09264b1af69a4a4595ba2e4539106d6f
@@ -4742,7 +4742,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 7c5269ac98e847f28da8d3d97e52a28e
- expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
+ expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
name: '{#SENSOR_INFO}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
@@ -4756,7 +4756,7 @@ zabbix_export:
value: performance
-
uuid: 616059e289694181aea6a076ecb093c1
- expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"notFunctioning\"}")=1'
+ expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"warning\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"notFunctioning\"}")=1'
name: '{#SENSOR_INFO}: Power supply is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
@@ -4764,7 +4764,7 @@ zabbix_export:
dependencies:
-
name: '{#SENSOR_INFO}: Power supply is in critical state'
- expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
+ expression: 'count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.psu.status[ciscoEnvMonSupplyState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"shutdown\"}")=1'
tags:
-
tag: scope
@@ -4820,9 +4820,9 @@ zabbix_export:
trigger_prototypes:
-
uuid: 67fad9e835f9466ab368bbdad6544e7e
- expression: 'avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
+ expression: 'avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'min(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
+ recovery_expression: 'min(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
name: '{#SNMPVALUE}: Temperature is too low'
event_name: '{#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
@@ -4838,13 +4838,13 @@ zabbix_export:
-
uuid: f138f708723a4ca49b21cb992798da7f
expression: |
- avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
+ avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
or
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
or
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
+ recovery_expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
name: '{#SNMPVALUE}: Temperature is above critical threshold'
event_name: '{#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
@@ -4860,11 +4860,11 @@ zabbix_export:
-
uuid: 281f7afca6ed4d3bb866430ec89e862e
expression: |
- avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}
+ avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}
or
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_WARN_STATUS}
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_WARN_STATUS}
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
+ recovery_expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
name: '{#SNMPVALUE}: Temperature is above warning threshold'
event_name: '{#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
@@ -4874,12 +4874,12 @@ zabbix_export:
-
name: '{#SNMPVALUE}: Temperature is above critical threshold'
expression: |
- avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
+ avg(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}
or
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_CRIT_STATUS}
or
- last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
- recovery_expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
+ last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.status[ciscoEnvMonTemperatureState.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS}
+ recovery_expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/sensor.temp.value[ciscoEnvMonTemperatureValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
tags:
-
tag: scope
@@ -5041,7 +5041,7 @@ zabbix_export:
type: GRAPH_PROTOTYPE
name: graphid
value:
- host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP'
+ host: 'Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP'
name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
valuemaps:
-
@@ -5975,8 +5975,8 @@ zabbix_export:
newvalue: unknown
triggers:
-
- uuid: f278b8b4eb784107a6d8d3e8437e8a66
- expression: '(last(/Cisco IOS prior to 12.0_3_T SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Cisco IOS prior to 12.0_3_T SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Cisco IOS prior to 12.0_3_T SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Cisco IOS prior to 12.0_3_T SNMP/system.net.uptime[sysUpTime.0])<10m)'
+ uuid: b98092ddf87247ff91710e2f310dbfb9
+ expression: '(last(/Cisco IOS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Cisco IOS by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Cisco IOS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Cisco IOS by SNMP/system.net.uptime[sysUpTime.0])<10m)'
name: 'Host has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
@@ -5985,14 +5985,14 @@ zabbix_export:
dependencies:
-
name: 'No SNMP data collection'
- expression: 'max(/Cisco IOS prior to 12.0_3_T SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
+ expression: 'max(/Cisco IOS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
tags:
-
tag: scope
value: notice
-
- uuid: b98092ddf87247ff91710e2f310dbfb9
- expression: '(last(/Cisco IOS SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Cisco IOS SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Cisco IOS SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Cisco IOS SNMP/system.net.uptime[sysUpTime.0])<10m)'
+ uuid: f278b8b4eb784107a6d8d3e8437e8a66
+ expression: '(last(/Cisco IOS prior to 12.0_3_T by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Cisco IOS prior to 12.0_3_T by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Cisco IOS prior to 12.0_3_T by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Cisco IOS prior to 12.0_3_T by SNMP/system.net.uptime[sysUpTime.0])<10m)'
name: 'Host has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
@@ -6001,14 +6001,14 @@ zabbix_export:
dependencies:
-
name: 'No SNMP data collection'
- expression: 'max(/Cisco IOS SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
+ expression: 'max(/Cisco IOS prior to 12.0_3_T by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
tags:
-
tag: scope
value: notice
-
uuid: 806f54999d064eb68a3f46a0d84ee4df
- expression: '(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/system.net.uptime[sysUpTime.0])<10m)'
+ expression: '(last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/system.net.uptime[sysUpTime.0])<10m)'
name: 'Host has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
@@ -6017,7 +6017,7 @@ zabbix_export:
dependencies:
-
name: 'No SNMP data collection'
- expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
+ expression: 'max(/Cisco IOS versions 12.0_3_T-12.2_3.5 by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
tags:
-
tag: scope
@@ -6033,5 +6033,5 @@ zabbix_export:
drawtype: GRADIENT_LINE
color: 1A7C11
item:
- host: 'Cisco IOS prior to 12.0_3_T SNMP'
+ host: 'Cisco IOS prior to 12.0_3_T by SNMP'
key: 'system.cpu.util[avgBusy5]'