diff --git a/templates/net/hp_hpn_snmp/README.md b/templates/net/hp_hpn_snmp/README.md
index 344335033ce..b4371ea6b8b 100644
--- a/templates/net/hp_hpn_snmp/README.md
+++ b/templates/net/hp_hpn_snmp/README.md
@@ -1,9 +1,9 @@
-# HP Enterprise Switch SNMP
+# HP Enterprise Switch by SNMP
## Overview
-For Zabbix version: 6.4 and higher
+For Zabbix version: 6.4 and higher.
This template was tested on:
@@ -111,30 +111,30 @@ There are no template links in this template.
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----|----|----|
-|High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/HP Enterprise Switch SNMP/system.cpu.util[hpSwitchCpuStat.0],5m)>{$CPU.UTIL.CRIT}` |WARNING | |
-|{#ENT_DESCR}: Fan is in critical state |<p>Please check the fan unit</p> |`count(/HP Enterprise Switch SNMP/sensor.fan.status[hpicfSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"bad\"}")=1` |AVERAGE | |
-|{#ENT_DESCR}: Fan is in warning state |<p>Please check the fan unit</p> |`count(/HP Enterprise Switch SNMP/sensor.fan.status[hpicfSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"warning\"}")=1` |WARNING |<p>**Depends on**:</p><p>- {#ENT_DESCR}: Fan is in critical state</p> |
-|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/HP Enterprise Switch SNMP/system.name,#1)<>last(/HP Enterprise Switch SNMP/system.name,#2) and length(last(/HP Enterprise Switch SNMP/system.name))>0` |INFO |<p>Manual close: YES</p> |
-|Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/HP Enterprise Switch SNMP/system.hw.serialnumber,#1)<>last(/HP Enterprise Switch SNMP/system.hw.serialnumber,#2) and length(last(/HP Enterprise Switch SNMP/system.hw.serialnumber))>0` |INFO |<p>Manual close: YES</p> |
-|Firmware has changed |<p>Firmware version has changed. Ack to close</p> |`last(/HP Enterprise Switch SNMP/system.hw.firmware,#1)<>last(/HP Enterprise Switch SNMP/system.hw.firmware,#2) and length(last(/HP Enterprise Switch SNMP/system.hw.firmware))>0` |INFO |<p>Manual close: YES</p> |
-|#{#SNMPVALUE}: High memory utilization |<p>The system is running out of free memory.</p> |`min(/HP Enterprise Switch SNMP/vm.memory.util[snmp.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | |
-|Interface {#IFNAME}({#IFALIAS}): In half-duplex mode |<p>Please check autonegotiation settings and cabling</p> |`last(/HP Enterprise Switch SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2` |WARNING |<p>Manual close: YES</p> |
-|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p><p>3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and last(/HP Enterprise Switch SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/HP Enterprise Switch SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/HP Enterprise Switch SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))`<p>Recovery expression:</p>`last(/HP Enterprise Switch SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0` |AVERAGE |<p>Manual close: YES</p> |
-|Interface {#IFNAME}({#IFALIAS}): High bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/HP Enterprise Switch SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/HP Enterprise Switch SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/HP Enterprise Switch SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/HP Enterprise Switch SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/HP Enterprise Switch SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0`<p>Recovery expression:</p>`avg(/HP Enterprise Switch SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/HP Enterprise Switch SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/HP Enterprise Switch SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/HP Enterprise Switch SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|Interface {#IFNAME}({#IFALIAS}): High error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/HP Enterprise Switch SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/HP Enterprise Switch SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/HP Enterprise Switch SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/HP Enterprise Switch SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/HP Enterprise Switch SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/HP Enterprise Switch SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/HP Enterprise Switch SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/HP Enterprise Switch SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/HP Enterprise Switch SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/HP Enterprise Switch SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/HP Enterprise Switch SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/HP Enterprise Switch SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/HP Enterprise Switch SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`<p>Recovery expression:</p>`(change(/HP Enterprise Switch SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/HP Enterprise Switch SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/HP Enterprise Switch SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|{#ENT_DESCR}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`count(/HP Enterprise Switch SNMP/sensor.psu.status[hpicfSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"bad\"}")=1` |AVERAGE | |
-|{#ENT_DESCR}: Power supply is in warning state |<p>Please check the power supply unit for errors</p> |`count(/HP Enterprise Switch SNMP/sensor.psu.status[hpicfSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"warning\"}")=1` |WARNING |<p>**Depends on**:</p><p>- {#ENT_DESCR}: Power supply is in critical state</p> |
-|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/HP Enterprise Switch SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/HP Enterprise Switch SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/HP Enterprise Switch SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/HP Enterprise Switch SNMP/system.net.uptime[sysUpTime.0])<10m)` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
-|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/HP Enterprise Switch SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
-|Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/HP Enterprise Switch SNMP/icmpping,#3)=0` |HIGH | |
-|High ICMP ping loss |<p>-</p> |`min(/HP Enterprise Switch SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/HP Enterprise Switch SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
-|High ICMP ping response time |<p>-</p> |`avg(/HP Enterprise Switch SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> |
-|{#SENSOR_INFO}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/HP Enterprise Switch SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_INFO}"}`<p>Recovery expression:</p>`max(/HP Enterprise Switch SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_INFO}"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_INFO}: Temperature is above critical threshold</p> |
-|{#SENSOR_INFO}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/HP Enterprise Switch SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}`<p>Recovery expression:</p>`max(/HP Enterprise Switch SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3` |HIGH | |
-|{#SENSOR_INFO}: Temperature is too low |<p>-</p> |`avg(/HP Enterprise Switch SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}`<p>Recovery expression:</p>`min(/HP Enterprise Switch SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}+3` |AVERAGE | |
+|High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/HP Enterprise Switch by SNMP/system.cpu.util[hpSwitchCpuStat.0],5m)>{$CPU.UTIL.CRIT}` |WARNING | |
+|{#ENT_DESCR}: Fan is in critical state |<p>Please check the fan unit</p> |`count(/HP Enterprise Switch by SNMP/sensor.fan.status[hpicfSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"bad\"}")=1` |AVERAGE | |
+|{#ENT_DESCR}: Fan is in warning state |<p>Please check the fan unit</p> |`count(/HP Enterprise Switch by SNMP/sensor.fan.status[hpicfSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"warning\"}")=1` |WARNING |<p>**Depends on**:</p><p>- {#ENT_DESCR}: Fan is in critical state</p> |
+|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/HP Enterprise Switch by SNMP/system.name,#1)<>last(/HP Enterprise Switch by SNMP/system.name,#2) and length(last(/HP Enterprise Switch by SNMP/system.name))>0` |INFO |<p>Manual close: YES</p> |
+|Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/HP Enterprise Switch by SNMP/system.hw.serialnumber,#1)<>last(/HP Enterprise Switch by SNMP/system.hw.serialnumber,#2) and length(last(/HP Enterprise Switch by SNMP/system.hw.serialnumber))>0` |INFO |<p>Manual close: YES</p> |
+|Firmware has changed |<p>Firmware version has changed. Ack to close</p> |`last(/HP Enterprise Switch by SNMP/system.hw.firmware,#1)<>last(/HP Enterprise Switch by SNMP/system.hw.firmware,#2) and length(last(/HP Enterprise Switch by SNMP/system.hw.firmware))>0` |INFO |<p>Manual close: YES</p> |
+|#{#SNMPVALUE}: High memory utilization |<p>The system is running out of free memory.</p> |`min(/HP Enterprise Switch by SNMP/vm.memory.util[snmp.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | |
+|Interface {#IFNAME}({#IFALIAS}): In half-duplex mode |<p>Please check autonegotiation settings and cabling</p> |`last(/HP Enterprise Switch by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2` |WARNING |<p>Manual close: YES</p> |
+|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p><p>3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and last(/HP Enterprise Switch by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/HP Enterprise Switch by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/HP Enterprise Switch by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))`<p>Recovery expression:</p>`last(/HP Enterprise Switch by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0` |AVERAGE |<p>Manual close: YES</p> |
+|Interface {#IFNAME}({#IFALIAS}): High bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/HP Enterprise Switch by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/HP Enterprise Switch by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/HP Enterprise Switch by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/HP Enterprise Switch by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/HP Enterprise Switch by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0`<p>Recovery expression:</p>`avg(/HP Enterprise Switch by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/HP Enterprise Switch by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/HP Enterprise Switch by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/HP Enterprise Switch by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|Interface {#IFNAME}({#IFALIAS}): High error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/HP Enterprise Switch by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/HP Enterprise Switch by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/HP Enterprise Switch by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/HP Enterprise Switch by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/HP Enterprise Switch by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/HP Enterprise Switch by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/HP Enterprise Switch by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/HP Enterprise Switch by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/HP Enterprise Switch by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/HP Enterprise Switch by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/HP Enterprise Switch by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/HP Enterprise Switch by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/HP Enterprise Switch by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`<p>Recovery expression:</p>`(change(/HP Enterprise Switch by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/HP Enterprise Switch by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/HP Enterprise Switch by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|{#ENT_DESCR}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`count(/HP Enterprise Switch by SNMP/sensor.psu.status[hpicfSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"bad\"}")=1` |AVERAGE | |
+|{#ENT_DESCR}: Power supply is in warning state |<p>Please check the power supply unit for errors</p> |`count(/HP Enterprise Switch by SNMP/sensor.psu.status[hpicfSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"warning\"}")=1` |WARNING |<p>**Depends on**:</p><p>- {#ENT_DESCR}: Power supply is in critical state</p> |
+|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/HP Enterprise Switch by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/HP Enterprise Switch by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/HP Enterprise Switch by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/HP Enterprise Switch by SNMP/system.net.uptime[sysUpTime.0])<10m)` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/HP Enterprise Switch by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
+|Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/HP Enterprise Switch by SNMP/icmpping,#3)=0` |HIGH | |
+|High ICMP ping loss |<p>-</p> |`min(/HP Enterprise Switch by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/HP Enterprise Switch by SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
+|High ICMP ping response time |<p>-</p> |`avg(/HP Enterprise Switch by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> |
+|{#SENSOR_INFO}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/HP Enterprise Switch by SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_INFO}"}`<p>Recovery expression:</p>`max(/HP Enterprise Switch by SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_INFO}"}-3` |WARNING |<p>**Depends on**:</p><p>- {#SENSOR_INFO}: Temperature is above critical threshold</p> |
+|{#SENSOR_INFO}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/HP Enterprise Switch by SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}`<p>Recovery expression:</p>`max(/HP Enterprise Switch by SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3` |HIGH | |
+|{#SENSOR_INFO}: Temperature is too low |<p>-</p> |`avg(/HP Enterprise Switch by SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}`<p>Recovery expression:</p>`min(/HP Enterprise Switch by SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}+3` |AVERAGE | |
## Feedback
-Please report any issues with the template at https://support.zabbix.com
+Please report any issues with the template at https://support.zabbix.com.