Welcome to mirror list, hosted at ThFree Co, Russian Federation.

github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
Diffstat (limited to 'templates/net/mikrotik/mikrotik_CRS328-24P-4S+RM_snmp/README.md')
-rw-r--r--templates/net/mikrotik/mikrotik_CRS328-24P-4S+RM_snmp/README.md62
1 files changed, 31 insertions, 31 deletions
diff --git a/templates/net/mikrotik/mikrotik_CRS328-24P-4S+RM_snmp/README.md b/templates/net/mikrotik/mikrotik_CRS328-24P-4S+RM_snmp/README.md
index 5e00b870168..42d9be714d2 100644
--- a/templates/net/mikrotik/mikrotik_CRS328-24P-4S+RM_snmp/README.md
+++ b/templates/net/mikrotik/mikrotik_CRS328-24P-4S+RM_snmp/README.md
@@ -1,9 +1,9 @@
-# MikroTik CRS328-24P-4S+RM SNMP
+# MikroTik CRS328-24P-4S+RM by SNMP
## Overview
-For Zabbix version: 6.4 and higher
+For Zabbix version: 6.4 and higher.
The template for monitoring Switch MikroTik CRS328-24P-4S+RM.
24 port Gigabit Ethernet router/switch with four 10Gbps SFP+ ports in 1U rackmount case, Dual Boot and PoE output, 500W
@@ -129,38 +129,38 @@ There are no template links in this template.
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----|----|----|
-|#{#SNMPINDEX}: High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/MikroTik CRS328-24P-4SRM SNMP/system.cpu.util[hrProcessorLoad.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}` |WARNING | |
-|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/MikroTik CRS328-24P-4SRM SNMP/system.name,#1)<>last(/MikroTik CRS328-24P-4SRM SNMP/system.name,#2) and length(last(/MikroTik CRS328-24P-4SRM SNMP/system.name))>0` |INFO |<p>Manual close: YES</p> |
-|Operating system description has changed |<p>Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.</p> |`last(/MikroTik CRS328-24P-4SRM SNMP/system.sw.os[mtxrLicVersion.0],#1)<>last(/MikroTik CRS328-24P-4SRM SNMP/system.sw.os[mtxrLicVersion.0],#2) and length(last(/MikroTik CRS328-24P-4SRM SNMP/system.sw.os[mtxrLicVersion.0]))>0` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- System name has changed</p> |
-|Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/MikroTik CRS328-24P-4SRM SNMP/system.hw.serialnumber,#1)<>last(/MikroTik CRS328-24P-4SRM SNMP/system.hw.serialnumber,#2) and length(last(/MikroTik CRS328-24P-4SRM SNMP/system.hw.serialnumber))>0` |INFO |<p>Manual close: YES</p> |
-|Firmware has changed |<p>Firmware version has changed. Ack to close</p> |`last(/MikroTik CRS328-24P-4SRM SNMP/system.hw.firmware,#1)<>last(/MikroTik CRS328-24P-4SRM SNMP/system.hw.firmware,#2) and length(last(/MikroTik CRS328-24P-4SRM SNMP/system.hw.firmware))>0` |INFO |<p>Manual close: YES</p> |
-|High memory utilization |<p>The system is running out of free memory.</p> |`min(/MikroTik CRS328-24P-4SRM SNMP/vm.memory.util[memoryUsedPercentage.Memory],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | |
-|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p><p>3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and last(/MikroTik CRS328-24P-4SRM SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/MikroTik CRS328-24P-4SRM SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/MikroTik CRS328-24P-4SRM SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))`<p>Recovery expression:</p>`last(/MikroTik CRS328-24P-4SRM SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0` |AVERAGE |<p>Manual close: YES</p> |
-|Interface {#IFNAME}({#IFALIAS}): High bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/MikroTik CRS328-24P-4SRM SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/MikroTik CRS328-24P-4SRM SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/MikroTik CRS328-24P-4SRM SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/MikroTik CRS328-24P-4SRM SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/MikroTik CRS328-24P-4SRM SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0`<p>Recovery expression:</p>`avg(/MikroTik CRS328-24P-4SRM SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/MikroTik CRS328-24P-4SRM SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/MikroTik CRS328-24P-4SRM SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/MikroTik CRS328-24P-4SRM SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|Interface {#IFNAME}({#IFALIAS}): High error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/MikroTik CRS328-24P-4SRM SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/MikroTik CRS328-24P-4SRM SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/MikroTik CRS328-24P-4SRM SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/MikroTik CRS328-24P-4SRM SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/MikroTik CRS328-24P-4SRM SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/MikroTik CRS328-24P-4SRM SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/MikroTik CRS328-24P-4SRM SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/MikroTik CRS328-24P-4SRM SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/MikroTik CRS328-24P-4SRM SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/MikroTik CRS328-24P-4SRM SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/MikroTik CRS328-24P-4SRM SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/MikroTik CRS328-24P-4SRM SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/MikroTik CRS328-24P-4SRM SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`<p>Recovery expression:</p>`(change(/MikroTik CRS328-24P-4SRM SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/MikroTik CRS328-24P-4SRM SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/MikroTik CRS328-24P-4SRM SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
-|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/MikroTik CRS328-24P-4SRM SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/MikroTik CRS328-24P-4SRM SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/MikroTik CRS328-24P-4SRM SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/MikroTik CRS328-24P-4SRM SNMP/system.net.uptime[sysUpTime.0])<10m)` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
-|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/MikroTik CRS328-24P-4SRM SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
-|Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/MikroTik CRS328-24P-4SRM SNMP/icmpping,#3)=0` |HIGH | |
-|High ICMP ping loss |<p>-</p> |`min(/MikroTik CRS328-24P-4SRM SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/MikroTik CRS328-24P-4SRM SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
-|High ICMP ping response time |<p>-</p> |`avg(/MikroTik CRS328-24P-4SRM SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> |
-|Disk-{#SNMPINDEX}: Disk space is critically low |<p>Two conditions should match: First, space utilization should be above {$VFS.FS.PUSED.MAX.CRIT:"Disk-{#SNMPINDEX}"}.</p><p> Second condition should be one of the following:</p><p> - The disk free space is less than {$VFS.FS.FREE.MIN.CRIT:"Disk-{#SNMPINDEX}"}.</p><p> - The disk will be full in less than 24 hours.</p> |`last(/MikroTik CRS328-24P-4SRM SNMP/vfs.fs.pused[hrStorageSize.{#SNMPINDEX}])>{$VFS.FS.PUSED.MAX.CRIT:"Disk-{#SNMPINDEX}"} and ((last(/MikroTik CRS328-24P-4SRM SNMP/vfs.fs.total[hrStorageSize.{#SNMPINDEX}])-last(/MikroTik CRS328-24P-4SRM SNMP/vfs.fs.used[hrStorageSize.{#SNMPINDEX}]))<{$VFS.FS.FREE.MIN.CRIT:"Disk-{#SNMPINDEX}"} or timeleft(/MikroTik CRS328-24P-4SRM SNMP/vfs.fs.pused[hrStorageSize.{#SNMPINDEX}],1h,100)<1d)` |AVERAGE |<p>Manual close: YES</p> |
-|Disk-{#SNMPINDEX}: Disk space is low |<p>Two conditions should match: First, space utilization should be above {$VFS.FS.PUSED.MAX.WARN:"Disk-{#SNMPINDEX}"}.</p><p> Second condition should be one of the following:</p><p> - The disk free space is less than {$VFS.FS.FREE.MIN.WARN:"Disk-{#SNMPINDEX}"}.</p><p> - The disk will be full in less than 24 hours.</p> |`last(/MikroTik CRS328-24P-4SRM SNMP/vfs.fs.pused[hrStorageSize.{#SNMPINDEX}])>{$VFS.FS.PUSED.MAX.WARN:"Disk-{#SNMPINDEX}"} and ((last(/MikroTik CRS328-24P-4SRM SNMP/vfs.fs.total[hrStorageSize.{#SNMPINDEX}])-last(/MikroTik CRS328-24P-4SRM SNMP/vfs.fs.used[hrStorageSize.{#SNMPINDEX}]))<{$VFS.FS.FREE.MIN.WARN:"Disk-{#SNMPINDEX}"} or timeleft(/MikroTik CRS328-24P-4SRM SNMP/vfs.fs.pused[hrStorageSize.{#SNMPINDEX}],1h,100)<1d)` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Disk-{#SNMPINDEX}: Disk space is critically low</p> |
-|CPU: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"CPU"}`<p>Recovery expression:</p>`max(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:"CPU"}-3` |WARNING |<p>**Depends on**:</p><p>- CPU: Temperature is above critical threshold</p> |
-|CPU: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"CPU"}`<p>Recovery expression:</p>`max(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"CPU"}-3` |HIGH | |
-|CPU: Temperature is too low |<p>-</p> |`avg(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"CPU"}`<p>Recovery expression:</p>`min(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"CPU"}+3` |AVERAGE | |
-|Device: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Device"}`<p>Recovery expression:</p>`max(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:"Device"}-3` |WARNING |<p>**Depends on**:</p><p>- Device: Temperature is above critical threshold</p> |
-|Device: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Device"}`<p>Recovery expression:</p>`max(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Device"}-3` |HIGH | |
-|Device: Temperature is too low |<p>-</p> |`avg(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Device"}`<p>Recovery expression:</p>`min(/MikroTik CRS328-24P-4SRM SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"Device"}+3` |AVERAGE | |
-|Interface {#IFNAME}({#IFALIAS}): LTE modem RSSI is low |<p>-</p> |`max(/MikroTik CRS328-24P-4SRM SNMP/lte.modem.rssi[mtxrLTEModemSignalRSSI.{#SNMPINDEX}],5m) < {$LTEMODEM.RSSI.MIN.WARN}` |WARNING | |
-|Interface {#IFNAME}({#IFALIAS}): LTE modem RSRP is low |<p>-</p> |`max(/MikroTik CRS328-24P-4SRM SNMP/lte.modem.rsrp[mtxrLTEModemSignalRSRP.{#SNMPINDEX}],5m) < {$LTEMODEM.RSRP.MIN.WARN}` |WARNING | |
-|Interface {#IFNAME}({#IFALIAS}): LTE modem RSRQ is low |<p>-</p> |`max(/MikroTik CRS328-24P-4SRM SNMP/lte.modem.rsrq[mtxrLTEModemSignalRSRQ.{#SNMPINDEX}],5m) < {$LTEMODEM.RSRQ.MIN.WARN}` |WARNING | |
-|Interface {#IFNAME}({#IFALIAS}): LTE modem SINR is low |<p>-</p> |`max(/MikroTik CRS328-24P-4SRM SNMP/lte.modem.sinr[mtxrLTEModemSignalSINR.{#SNMPINDEX}],5m) < {$LTEMODEM.SINR.MIN.WARN}` |WARNING | |
-|Interface {#IFNAME}({#IFALIAS}): AP interface {#IFNAME}({#IFALIAS}) is not running |<p>Access point interface can be not running by different reasons - disabled interface, power off, network link down.</p> |`last(/MikroTik CRS328-24P-4SRM SNMP/ssid.state[mtxrWlCMState.{#SNMPINDEX}])<>"running-ap"` |WARNING | |
+|#{#SNMPINDEX}: High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/MikroTik CRS328-24P-4SRM by SNMP/system.cpu.util[hrProcessorLoad.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}` |WARNING | |
+|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/MikroTik CRS328-24P-4SRM by SNMP/system.name,#1)<>last(/MikroTik CRS328-24P-4SRM by SNMP/system.name,#2) and length(last(/MikroTik CRS328-24P-4SRM by SNMP/system.name))>0` |INFO |<p>Manual close: YES</p> |
+|Operating system description has changed |<p>Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.</p> |`last(/MikroTik CRS328-24P-4SRM by SNMP/system.sw.os[mtxrLicVersion.0],#1)<>last(/MikroTik CRS328-24P-4SRM by SNMP/system.sw.os[mtxrLicVersion.0],#2) and length(last(/MikroTik CRS328-24P-4SRM by SNMP/system.sw.os[mtxrLicVersion.0]))>0` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- System name has changed</p> |
+|Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/MikroTik CRS328-24P-4SRM by SNMP/system.hw.serialnumber,#1)<>last(/MikroTik CRS328-24P-4SRM by SNMP/system.hw.serialnumber,#2) and length(last(/MikroTik CRS328-24P-4SRM by SNMP/system.hw.serialnumber))>0` |INFO |<p>Manual close: YES</p> |
+|Firmware has changed |<p>Firmware version has changed. Ack to close</p> |`last(/MikroTik CRS328-24P-4SRM by SNMP/system.hw.firmware,#1)<>last(/MikroTik CRS328-24P-4SRM by SNMP/system.hw.firmware,#2) and length(last(/MikroTik CRS328-24P-4SRM by SNMP/system.hw.firmware))>0` |INFO |<p>Manual close: YES</p> |
+|High memory utilization |<p>The system is running out of free memory.</p> |`min(/MikroTik CRS328-24P-4SRM by SNMP/vm.memory.util[memoryUsedPercentage.Memory],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | |
+|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p><p>3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))`<p>Recovery expression:</p>`last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0` |AVERAGE |<p>Manual close: YES</p> |
+|Interface {#IFNAME}({#IFALIAS}): High bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/MikroTik CRS328-24P-4SRM by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/MikroTik CRS328-24P-4SRM by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0`<p>Recovery expression:</p>`avg(/MikroTik CRS328-24P-4SRM by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/MikroTik CRS328-24P-4SRM by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|Interface {#IFNAME}({#IFALIAS}): High error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/MikroTik CRS328-24P-4SRM by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/MikroTik CRS328-24P-4SRM by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/MikroTik CRS328-24P-4SRM by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/MikroTik CRS328-24P-4SRM by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/MikroTik CRS328-24P-4SRM by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`<p>Recovery expression:</p>`(change(/MikroTik CRS328-24P-4SRM by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/MikroTik CRS328-24P-4SRM by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
+|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/MikroTik CRS328-24P-4SRM by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/MikroTik CRS328-24P-4SRM by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/MikroTik CRS328-24P-4SRM by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/MikroTik CRS328-24P-4SRM by SNMP/system.net.uptime[sysUpTime.0])<10m)` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
+|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/MikroTik CRS328-24P-4SRM by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
+|Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/MikroTik CRS328-24P-4SRM by SNMP/icmpping,#3)=0` |HIGH | |
+|High ICMP ping loss |<p>-</p> |`min(/MikroTik CRS328-24P-4SRM by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/MikroTik CRS328-24P-4SRM by SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
+|High ICMP ping response time |<p>-</p> |`avg(/MikroTik CRS328-24P-4SRM by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> |
+|Disk-{#SNMPINDEX}: Disk space is critically low |<p>Two conditions should match: First, space utilization should be above {$VFS.FS.PUSED.MAX.CRIT:"Disk-{#SNMPINDEX}"}.</p><p> Second condition should be one of the following:</p><p> - The disk free space is less than {$VFS.FS.FREE.MIN.CRIT:"Disk-{#SNMPINDEX}"}.</p><p> - The disk will be full in less than 24 hours.</p> |`last(/MikroTik CRS328-24P-4SRM by SNMP/vfs.fs.pused[hrStorageSize.{#SNMPINDEX}])>{$VFS.FS.PUSED.MAX.CRIT:"Disk-{#SNMPINDEX}"} and ((last(/MikroTik CRS328-24P-4SRM by SNMP/vfs.fs.total[hrStorageSize.{#SNMPINDEX}])-last(/MikroTik CRS328-24P-4SRM by SNMP/vfs.fs.used[hrStorageSize.{#SNMPINDEX}]))<{$VFS.FS.FREE.MIN.CRIT:"Disk-{#SNMPINDEX}"} or timeleft(/MikroTik CRS328-24P-4SRM by SNMP/vfs.fs.pused[hrStorageSize.{#SNMPINDEX}],1h,100)<1d)` |AVERAGE |<p>Manual close: YES</p> |
+|Disk-{#SNMPINDEX}: Disk space is low |<p>Two conditions should match: First, space utilization should be above {$VFS.FS.PUSED.MAX.WARN:"Disk-{#SNMPINDEX}"}.</p><p> Second condition should be one of the following:</p><p> - The disk free space is less than {$VFS.FS.FREE.MIN.WARN:"Disk-{#SNMPINDEX}"}.</p><p> - The disk will be full in less than 24 hours.</p> |`last(/MikroTik CRS328-24P-4SRM by SNMP/vfs.fs.pused[hrStorageSize.{#SNMPINDEX}])>{$VFS.FS.PUSED.MAX.WARN:"Disk-{#SNMPINDEX}"} and ((last(/MikroTik CRS328-24P-4SRM by SNMP/vfs.fs.total[hrStorageSize.{#SNMPINDEX}])-last(/MikroTik CRS328-24P-4SRM by SNMP/vfs.fs.used[hrStorageSize.{#SNMPINDEX}]))<{$VFS.FS.FREE.MIN.WARN:"Disk-{#SNMPINDEX}"} or timeleft(/MikroTik CRS328-24P-4SRM by SNMP/vfs.fs.pused[hrStorageSize.{#SNMPINDEX}],1h,100)<1d)` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Disk-{#SNMPINDEX}: Disk space is critically low</p> |
+|CPU: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"CPU"}`<p>Recovery expression:</p>`max(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:"CPU"}-3` |WARNING |<p>**Depends on**:</p><p>- CPU: Temperature is above critical threshold</p> |
+|CPU: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"CPU"}`<p>Recovery expression:</p>`max(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"CPU"}-3` |HIGH | |
+|CPU: Temperature is too low |<p>-</p> |`avg(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"CPU"}`<p>Recovery expression:</p>`min(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlProcessorTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"CPU"}+3` |AVERAGE | |
+|Device: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Device"}`<p>Recovery expression:</p>`max(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:"Device"}-3` |WARNING |<p>**Depends on**:</p><p>- Device: Temperature is above critical threshold</p> |
+|Device: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Device"}`<p>Recovery expression:</p>`max(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Device"}-3` |HIGH | |
+|Device: Temperature is too low |<p>-</p> |`avg(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Device"}`<p>Recovery expression:</p>`min(/MikroTik CRS328-24P-4SRM by SNMP/sensor.temp.value[mtxrHlTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"Device"}+3` |AVERAGE | |
+|Interface {#IFNAME}({#IFALIAS}): LTE modem RSSI is low |<p>-</p> |`max(/MikroTik CRS328-24P-4SRM by SNMP/lte.modem.rssi[mtxrLTEModemSignalRSSI.{#SNMPINDEX}],5m) < {$LTEMODEM.RSSI.MIN.WARN}` |WARNING | |
+|Interface {#IFNAME}({#IFALIAS}): LTE modem RSRP is low |<p>-</p> |`max(/MikroTik CRS328-24P-4SRM by SNMP/lte.modem.rsrp[mtxrLTEModemSignalRSRP.{#SNMPINDEX}],5m) < {$LTEMODEM.RSRP.MIN.WARN}` |WARNING | |
+|Interface {#IFNAME}({#IFALIAS}): LTE modem RSRQ is low |<p>-</p> |`max(/MikroTik CRS328-24P-4SRM by SNMP/lte.modem.rsrq[mtxrLTEModemSignalRSRQ.{#SNMPINDEX}],5m) < {$LTEMODEM.RSRQ.MIN.WARN}` |WARNING | |
+|Interface {#IFNAME}({#IFALIAS}): LTE modem SINR is low |<p>-</p> |`max(/MikroTik CRS328-24P-4SRM by SNMP/lte.modem.sinr[mtxrLTEModemSignalSINR.{#SNMPINDEX}],5m) < {$LTEMODEM.SINR.MIN.WARN}` |WARNING | |
+|Interface {#IFNAME}({#IFALIAS}): AP interface {#IFNAME}({#IFALIAS}) is not running |<p>Access point interface can be not running by different reasons - disabled interface, power off, network link down.</p> |`last(/MikroTik CRS328-24P-4SRM by SNMP/ssid.state[mtxrWlCMState.{#SNMPINDEX}])<>"running-ap"` |WARNING | |
## Feedback
-Please report any issues with the template at https://support.zabbix.com
+Please report any issues with the template at https://support.zabbix.com.
## References