diff options
Diffstat (limited to 'templates/net/morningstar/morningstar_tristar_pwm_snmp/template_net_morningstar_tristar_pwm_snmp.yaml')
-rw-r--r-- | templates/net/morningstar/morningstar_tristar_pwm_snmp/template_net_morningstar_tristar_pwm_snmp.yaml | 118 |
1 files changed, 59 insertions, 59 deletions
diff --git a/templates/net/morningstar/morningstar_tristar_pwm_snmp/template_net_morningstar_tristar_pwm_snmp.yaml b/templates/net/morningstar/morningstar_tristar_pwm_snmp/template_net_morningstar_tristar_pwm_snmp.yaml index dacbee08cf6..c0666c1e9a2 100644 --- a/templates/net/morningstar/morningstar_tristar_pwm_snmp/template_net_morningstar_tristar_pwm_snmp.yaml +++ b/templates/net/morningstar/morningstar_tristar_pwm_snmp/template_net_morningstar_tristar_pwm_snmp.yaml @@ -1,6 +1,6 @@ zabbix_export: version: '6.4' - date: '2022-08-16T10:54:50Z' + date: '2022-10-27T14:44:08Z' template_groups: - uuid: 36bff6c29af64692839d077febfc7079 @@ -8,8 +8,8 @@ zabbix_export: templates: - uuid: 230fa9f7c1774821bbe6cdcbbba5cbc6 - template: 'Morningstar TriStar PWM SNMP' - name: 'Morningstar TriStar PWM SNMP' + template: 'Morningstar TriStar PWM by SNMP' + name: 'Morningstar TriStar PWM by SNMP' description: | MIBs used: TRISTAR @@ -189,7 +189,7 @@ zabbix_export: triggers: - uuid: 121d47c6bbdd45bca261df2e01ea41c6 - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","batterySense")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","batterySense")=2' name: 'Status: Device has "batterySense" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -199,7 +199,7 @@ zabbix_export: value: notice - uuid: fd2d9290144143d39bb5a3cf0a2d261f - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","batterySenseDisconnected")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","batterySenseDisconnected")=2' name: 'Status: Device has "batterySenseDisconnected" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -209,7 +209,7 @@ zabbix_export: value: notice - uuid: 83d5b8d52acd4e21ac6d3a9cf05dcd04 - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","currentLimit")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","currentLimit")=2' name: 'Status: Device has "currentLimit" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -219,7 +219,7 @@ zabbix_export: value: notice - uuid: d9529a4372d848038e6ee561d62e9f22 - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","currentOffset")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","currentOffset")=2' name: 'Status: Device has "currentOffset" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -229,7 +229,7 @@ zabbix_export: value: notice - uuid: 5f3983acc1cc417e860c1305b11c15ea - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","diversionLoadNearMax")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","diversionLoadNearMax")=2' name: 'Status: Device has "diversionLoadNearMax" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -239,7 +239,7 @@ zabbix_export: value: notice - uuid: 878e04df7e7b416bb0d2213b5dbb80e6 - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorOpen")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorOpen")=2' name: 'Status: Device has "heatsinkTempSensorOpen" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -249,7 +249,7 @@ zabbix_export: value: notice - uuid: c642ed9496ce4322809c7142d32929a5 - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorShorted")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorShorted")=2' name: 'Status: Device has "heatsinkTempSensorShorted" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -259,7 +259,7 @@ zabbix_export: value: notice - uuid: 532421fe17bf4732a01a6990e34e649a - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","highVoltageDisconnect")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","highVoltageDisconnect")=2' name: 'Status: Device has "highVoltageDisconnect" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -269,7 +269,7 @@ zabbix_export: value: notice - uuid: ae90e8034baf4b21906d56d18bfa4da8 - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","loadDisconnectState")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","loadDisconnectState")=2' name: 'Status: Device has "loadDisconnectState" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -279,7 +279,7 @@ zabbix_export: value: notice - uuid: 8d8b721c6dee40499b29bee44b21589a - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","mosfetSOpen")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","mosfetSOpen")=2' name: 'Status: Device has "mosfetSOpen" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -289,7 +289,7 @@ zabbix_export: value: notice - uuid: 8cda8e5773de4583b9baa6a6e542e32c - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","p12VoltageReferenceOff")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","p12VoltageReferenceOff")=2' name: 'Status: Device has "p12VoltageReferenceOff" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -299,7 +299,7 @@ zabbix_export: value: notice - uuid: 1b6192b8ca364c229b35ba6de89ad56b - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","rtsDisconnected")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","rtsDisconnected")=2' name: 'Status: Device has "rtsDisconnected" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -309,7 +309,7 @@ zabbix_export: value: notice - uuid: 176de77a142d45a3ac39ea42989e209c - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","rtsMiswire")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","rtsMiswire")=2' name: 'Status: Device has "rtsMiswire" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -319,7 +319,7 @@ zabbix_export: value: notice - uuid: f63029eabc8e498ea7e6336d312ac169 - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","rtsShorted")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","rtsShorted")=2' name: 'Status: Device has "rtsShorted" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -329,7 +329,7 @@ zabbix_export: value: notice - uuid: 480b69c1febf45a2971788c2f967c45d - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","systemMiswire")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","systemMiswire")=2' name: 'Status: Device has "systemMiswire" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -339,7 +339,7 @@ zabbix_export: value: notice - uuid: 4a287e4086c4458aaa3dc48bbb8ee219 - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","tristarHot")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","tristarHot")=2' name: 'Status: Device has "tristarHot" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -349,7 +349,7 @@ zabbix_export: value: notice - uuid: de665482d2574730a3a839948dd730ea - expression: 'count(/Morningstar TriStar PWM SNMP/status.alarms[alarms.0],#3,"like","uncalibrated")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","uncalibrated")=2' name: 'Status: Device has "uncalibrated" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING @@ -414,7 +414,7 @@ zabbix_export: triggers: - uuid: 514b041aebdd4ddb8ab2d1222c0ef295 - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","customSettingsEdit")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","customSettingsEdit")=2' name: 'Status: Device has "customSettingsEdit" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -424,7 +424,7 @@ zabbix_export: value: notice - uuid: 1a40ce8b87f04ab1b4f30387e9ce2d9d - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","dipSwitchChange")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","dipSwitchChange")=2' name: 'Status: Device has "dipSwitchChange" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -434,7 +434,7 @@ zabbix_export: value: notice - uuid: 49b120c3933c43b1b7f5c77f7b359997 - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","externalShort")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","externalShort")=2' name: 'Status: Device has "externalShort" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -444,7 +444,7 @@ zabbix_export: value: notice - uuid: f063b9f717c44ab988db7ac95bfca68f - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","highVoltageDisconnect")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","highVoltageDisconnect")=2' name: 'Status: Device has "highVoltageDisconnect" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -454,7 +454,7 @@ zabbix_export: value: notice - uuid: 468716d748f1470cb764ce1af922164d - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","mosfetSShorted")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","mosfetSShorted")=2' name: 'Status: Device has "mosfetSShorted" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -464,7 +464,7 @@ zabbix_export: value: notice - uuid: b6f65dfca421490eafff48991cdf1e3b - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","overcurrent")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","overcurrent")=2' name: 'Status: Device has "overcurrent" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -474,7 +474,7 @@ zabbix_export: value: notice - uuid: 73561a5765694633b1dc0ef1b1f60fd4 - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","reset")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","reset")=2' name: 'Status: Device has "reset" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -484,7 +484,7 @@ zabbix_export: value: notice - uuid: d14c7d928f57448390c2b4c588a28c65 - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","rtsDisconnected")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","rtsDisconnected")=2' name: 'Status: Device has "rtsDisconnected" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -494,7 +494,7 @@ zabbix_export: value: notice - uuid: d94067598c234968b4929404067eff86 - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","rtsShorted")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","rtsShorted")=2' name: 'Status: Device has "rtsShorted" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -504,7 +504,7 @@ zabbix_export: value: notice - uuid: 886b18bee7cd4f8eb454973e2d2ae59f - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","softwareFault")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","softwareFault")=2' name: 'Status: Device has "softwareFault" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -514,7 +514,7 @@ zabbix_export: value: notice - uuid: 2e520cdafaaa4eefad5ebea71819c3a6 - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","systemMiswire")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","systemMiswire")=2' name: 'Status: Device has "systemMiswire" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -524,7 +524,7 @@ zabbix_export: value: notice - uuid: 041be44e639d4d1eadb15230a678e278 - expression: 'count(/Morningstar TriStar PWM SNMP/status.faults[faults.0],#3,"like","tristarHot")=2' + expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","tristarHot")=2' name: 'Status: Device has "tristarHot" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -577,7 +577,7 @@ zabbix_export: triggers: - uuid: 64aa2a79fe854def8e179a4d27790417 - expression: 'nodata(/Morningstar TriStar PWM SNMP/status.net.uptime,5m)=1' + expression: 'nodata(/Morningstar TriStar PWM by SNMP/status.net.uptime,5m)=1' name: 'Status: Failed to fetch data' event_name: 'Status: Failed to fetch data (or no data for 5m)' priority: WARNING @@ -610,7 +610,7 @@ zabbix_export: triggers: - uuid: e759b90e2bf44bbb8e5efe5b9e458e40 - expression: 'min(/Morningstar TriStar PWM SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}' + expression: 'min(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}' name: 'Temperature: Critically high battery temperature' event_name: 'Temperature: Critically high battery temperature (over {$BATTERY.TEMP.MAX.CRIT}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -621,7 +621,7 @@ zabbix_export: value: notice - uuid: e57f335f657d45768509f139d31dcdae - expression: 'max(/Morningstar TriStar PWM SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}' + expression: 'max(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}' name: 'Temperature: Critically low battery temperature' event_name: 'Temperature: Critically low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -632,7 +632,7 @@ zabbix_export: value: notice - uuid: 7d1444dba9334e91ad425a6f2ff9fef9 - expression: 'min(/Morningstar TriStar PWM SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.WARN}' + expression: 'min(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.WARN}' name: 'Temperature: High battery temperature' event_name: 'Temperature: High battery temperature (over {$BATTERY.TEMP.MAX.WARN}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -640,14 +640,14 @@ zabbix_export: dependencies: - name: 'Temperature: Critically high battery temperature' - expression: 'min(/Morningstar TriStar PWM SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}' + expression: 'min(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}' tags: - tag: scope value: notice - uuid: 14fe4a22b28c4d08a24da51a54e36e81 - expression: 'max(/Morningstar TriStar PWM SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.WARN}' + expression: 'max(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.WARN}' name: 'Temperature: Low battery temperature' event_name: 'Temperature: Low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -655,7 +655,7 @@ zabbix_export: dependencies: - name: 'Temperature: Critically low battery temperature' - expression: 'max(/Morningstar TriStar PWM SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}' + expression: 'max(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}' tags: - tag: scope @@ -722,7 +722,7 @@ zabbix_export: trigger_prototypes: - uuid: 156ec13d673b4a8aa02a87b1794cb722 - expression: 'min(/Morningstar TriStar PWM SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}' + expression: 'min(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}' name: 'Battery: Critically high battery voltage' event_name: 'Battery: Critically high battery voltage (over {#VOLTAGE.MAX.CRIT}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -733,7 +733,7 @@ zabbix_export: value: capacity - uuid: 5e4400321f4f45b39397c68a4ba54d8e - expression: 'max(/Morningstar TriStar PWM SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}' + expression: 'max(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}' name: 'Battery: Critically low battery voltage' event_name: 'Battery: Critically low battery voltage (below {#VOLTAGE.MIN.CRIT}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -744,7 +744,7 @@ zabbix_export: value: capacity - uuid: fa6502a4a0214f7f933e982182d21d6b - expression: 'min(/Morningstar TriStar PWM SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.WARN}' + expression: 'min(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.WARN}' name: 'Battery: High battery voltage' event_name: 'Battery: High battery voltage (over {#VOLTAGE.MAX.WARN}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -752,14 +752,14 @@ zabbix_export: dependencies: - name: 'Battery: Critically high battery voltage' - expression: 'min(/Morningstar TriStar PWM SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}' + expression: 'min(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}' tags: - tag: scope value: capacity - uuid: a5275748f4c742ea8ab9efd266901e95 - expression: 'max(/Morningstar TriStar PWM SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.WARN}' + expression: 'max(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.WARN}' name: 'Battery: Low battery voltage' event_name: 'Battery: Low battery voltage (below {#VOLTAGE.MIN.WARN}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -767,7 +767,7 @@ zabbix_export: dependencies: - name: 'Battery: Critically low battery voltage' - expression: 'max(/Morningstar TriStar PWM SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}' + expression: 'max(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}' tags: - tag: scope @@ -781,7 +781,7 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Morningstar TriStar PWM SNMP' + host: 'Morningstar TriStar PWM by SNMP' key: 'battery.voltage[batteryVoltage.0{#SINGLETON}]' master_item: key: 'battery.voltage.discovery[batteryVoltage.0]' @@ -889,7 +889,7 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Morningstar TriStar PWM SNMP' + host: 'Morningstar TriStar PWM by SNMP' key: 'array.voltage[arrayloadVoltage.0{#SINGLETON}]' - uuid: cd64c57669314d2e9526fbc580034c81 @@ -899,7 +899,7 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Morningstar TriStar PWM SNMP' + host: 'Morningstar TriStar PWM by SNMP' key: 'charge.current[chargeCurrent.0{#SINGLETON}]' master_item: key: 'control.mode[controlMode.0]' @@ -943,7 +943,7 @@ zabbix_export: trigger_prototypes: - uuid: da21473ce79c42269cc24d3e470b7d07 - expression: 'last(/Morningstar TriStar PWM SNMP/charge.state[controlState.0{#SINGLETON}])={$CHARGE.STATE.CRIT}' + expression: 'last(/Morningstar TriStar PWM by SNMP/charge.state[controlState.0{#SINGLETON}])={$CHARGE.STATE.CRIT}' name: 'Battery: Device charge in critical state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -953,14 +953,14 @@ zabbix_export: value: notice - uuid: 79a592050bc64c018cfa5c7b779fba02 - expression: 'last(/Morningstar TriStar PWM SNMP/charge.state[controlState.0{#SINGLETON}])={$CHARGE.STATE.WARN}' + expression: 'last(/Morningstar TriStar PWM by SNMP/charge.state[controlState.0{#SINGLETON}])={$CHARGE.STATE.WARN}' name: 'Battery: Device charge in warning state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Battery: Device charge in critical state' - expression: 'last(/Morningstar TriStar PWM SNMP/charge.state[controlState.0{#SINGLETON}])={$CHARGE.STATE.CRIT}' + expression: 'last(/Morningstar TriStar PWM by SNMP/charge.state[controlState.0{#SINGLETON}])={$CHARGE.STATE.CRIT}' tags: - tag: scope @@ -1094,7 +1094,7 @@ zabbix_export: trigger_prototypes: - uuid: 9035e0a92d384a3c844b8a4d4ebd1eb9 - expression: 'last(/Morningstar TriStar PWM SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar TriStar PWM SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"fault"}' + expression: 'last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"fault"}' name: 'Load: Device load in critical state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH @@ -1104,14 +1104,14 @@ zabbix_export: value: notice - uuid: a2d13f97c4bd46bfab8e74a2f2a7df2e - expression: 'last(/Morningstar TriStar PWM SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.WARN:"lvdWarning"} or last(/Morningstar TriStar PWM SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.WARN:"override"}' + expression: 'last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.WARN:"lvdWarning"} or last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.WARN:"override"}' name: 'Load: Device load in warning state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Load: Device load in critical state' - expression: 'last(/Morningstar TriStar PWM SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar TriStar PWM SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"fault"}' + expression: 'last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"fault"}' tags: - tag: scope @@ -1201,7 +1201,7 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Morningstar TriStar PWM SNMP' + host: 'Morningstar TriStar PWM by SNMP' key: 'load.current[loadCurrent.0{#SINGLETON}]' - uuid: b4b595193e0c40a2b390f7ce6eefba4a @@ -1211,7 +1211,7 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Morningstar TriStar PWM SNMP' + host: 'Morningstar TriStar PWM by SNMP' key: 'load.voltage[arrayloadVoltage.0{#SINGLETON}]' master_item: key: 'control.mode[controlMode.0]' @@ -1364,7 +1364,7 @@ zabbix_export: triggers: - uuid: f0549419f015448497cd7d15a2bf96fa - expression: '(last(/Morningstar TriStar PWM SNMP/status.hw.uptime)>0 and last(/Morningstar TriStar PWM SNMP/status.hw.uptime)<10m) or (last(/Morningstar TriStar PWM SNMP/status.hw.uptime)=0 and last(/Morningstar TriStar PWM SNMP/status.net.uptime)<10m)' + expression: '(last(/Morningstar TriStar PWM by SNMP/status.hw.uptime)>0 and last(/Morningstar TriStar PWM by SNMP/status.hw.uptime)<10m) or (last(/Morningstar TriStar PWM by SNMP/status.hw.uptime)=0 and last(/Morningstar TriStar PWM by SNMP/status.net.uptime)<10m)' name: 'Status: Device has been restarted' event_name: 'Status: Device has been restarted (uptime < 10m)' priority: INFO @@ -1383,12 +1383,12 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Morningstar TriStar PWM SNMP' + host: 'Morningstar TriStar PWM by SNMP' key: 'temp.battery[batteryTemperature.0]' - sortorder: '1' drawtype: GRADIENT_LINE color: 2774A4 item: - host: 'Morningstar TriStar PWM SNMP' + host: 'Morningstar TriStar PWM by SNMP' key: 'temp.heatsink[heatsinkTemperature.0]' |