diff options
Diffstat (limited to 'templates/net/zyxel_snmp/zyxel_mes3500-24_snmp/README.md')
-rw-r--r-- | templates/net/zyxel_snmp/zyxel_mes3500-24_snmp/README.md | 36 |
1 files changed, 18 insertions, 18 deletions
diff --git a/templates/net/zyxel_snmp/zyxel_mes3500-24_snmp/README.md b/templates/net/zyxel_snmp/zyxel_mes3500-24_snmp/README.md index 80ea3028acd..baab93fc68d 100644 --- a/templates/net/zyxel_snmp/zyxel_mes3500-24_snmp/README.md +++ b/templates/net/zyxel_snmp/zyxel_mes3500-24_snmp/README.md @@ -1,9 +1,9 @@ -# ZYXEL MES3500-24 SNMP +# ZYXEL MES3500-24 by SNMP ## Overview -For Zabbix version: 6.4 and higher +For Zabbix version: 6.4 and higher. https://service-provider.zyxel.com/emea/en/products/carrier-and-access-switches/access-switches/mes3500-series This template was tested on: @@ -46,7 +46,7 @@ There are no template links in this template. |Name|Description|Type|Key and additional info| |----|-----------|----|----| -|Interface discovery |<p>-</p> |SNMP |zyxel.3500_24.net.if.discovery<p>**Filter**:</p>AND <p>- {#ZYXEL.IF.NAME} MATCHES_REGEX `{$ZYXEL.LLD.FILTER.IF.NAME.MATCHES}`</p><p>- {#ZYXEL.IF.NAME} NOT_MATCHES_REGEX `{$ZYXEL.LLD.FILTER.IF.NAME.NOT_MATCHES}`</p><p>- {#ZYXEL.IF.LINKUPTYPE} MATCHES_REGEX `{$ZYXEL.LLD.FILTER.IF.LINKUPTYPE.MATCHES}`</p><p>- {#ZYXEL.IF.LINKUPTYPE} NOT_MATCHES_REGEX `{$ZYXEL.LLD.FILTER.IF.LINKUPTYPE.NOT_MATCHES}`</p><p>**Overrides:**</p><p>Don't create triggers for matching interface<br> - {#ZYXEL.IF.NAME} NOT_MATCHES_REGEX `{$ZYXEL.LLD.FILTER.IF.CONTROL.MATCHES}`<br> - TRIGGER_PROTOTYPE REGEXP `.*` - NO_DISCOVER</p> | +|Interface discovery |<p>-</p> |SNMP |zyxel.3500_24.net.if.discovery<p>**Filter**:</p>AND <p>- {#ZYXEL.IF.NAME} MATCHES_REGEX `{$ZYXEL.LLD.FILTER.IF.NAME.MATCHES}`</p><p>- {#ZYXEL.IF.NAME} NOT_MATCHES_REGEX `{$ZYXEL.LLD.FILTER.IF.NAME.NOT_MATCHES}`</p><p>- {#ZYXEL.IF.LINKUPTYPE} MATCHES_REGEX `{$ZYXEL.LLD.FILTER.IF.LINKUPTYPE.MATCHES}`</p><p>- {#ZYXEL.IF.LINKUPTYPE} NOT_MATCHES_REGEX `{$ZYXEL.LLD.FILTER.IF.LINKUPTYPE.NOT_MATCHES}`</p><p>**Overrides:**</p><p>Don't create triggers for matching interface<br> - {#ZYXEL.IF.NAME} NOT_MATCHES_REGEX `{$ZYXEL.LLD.FILTER.IF.CONTROL.MATCHES}`<br> - TRIGGER_PROTOTYPE REGEXP `.*`<br> - NO_DISCOVER</p> | |Memory pool discovery |<p>-</p> |SNMP |zyxel.3500_24.memory.discovery | |SFP with DDM discovery |<p>SFP DDM module discovery.</p> |SNMP |zyxel.3500_24.sfp.ddm.discovery<p>**Preprocessing**:</p><p>- JAVASCRIPT: `The text is too long. Please see the template.`</p><p>**Filter**:</p>AND <p>- {#ZYXEL.SFP.DESCRIPTION} MATCHES_REGEX `{$ZYXEL.LLD.FILTER.SFPDDM.DESC.MATCHES}`</p><p>- {#ZYXEL.SFP.DESCRIPTION} NOT_MATCHES_REGEX `{$ZYXEL.LLD.FILTER.SFPDDM.DESC.NOT_MATCHES}`</p> | |SFP without DDM discovery |<p>SFP module discovery.</p> |SNMP |zyxel.3500_24.sfp.discovery<p>**Filter**:</p>AND <p>- {#ZYXEL.SFP.STATUS} MATCHES_REGEX `{$ZYXEL.LLD.FILTER.SFP.STATUS.MATCHES}`</p><p>- {#ZYXEL.SFP.STATUS} NOT_MATCHES_REGEX `{$ZYXEL.LLD.FILTER.SFP.STATUS.NOT_MATCHES}`</p> | @@ -101,25 +101,25 @@ There are no template links in this template. |Name|Description|Expression|Severity|Dependencies and additional info| |----|-----------|----|----|----| -|ZYXEL MES3500-24: High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.cpuusage,5m)>{$CPU.UTIL.CRIT}` |WARNING | | -|ZYXEL MES3500-24: Template does not match hardware |<p>This template is for Zyxel MES3500-24, but connected to {ITEM.VALUE}</p> |`last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.model)<>"MES3500-24"` |INFO | | -|ZYXEL MES3500-24: Firmware has changed |<p>Firmware version has changed. Ack to close</p> |`last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.fwversion,#1)<>last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.fwversion,#2) and length(last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.fwversion))>0` |INFO |<p>Manual close: YES</p> | -|ZYXEL MES3500-24: Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.serialnumber,#1)<>last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.serialnumber,#2) and length(last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.serialnumber))>0` |INFO |<p>Manual close: YES</p> | -|ZYXEL MES3500-24: High memory utilization in "{#ZYXEL.MEMORY.NAME}" pool |<p>The system is running out of free memory.</p> |`min(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.memory[{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | | -|ZYXEL MES3500-24: Port {#SNMPINDEX}: Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.net.if.operstatus[{#SNMPINDEX}])=2 and last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.net.if.operstatus[{#SNMPINDEX}],#1)<>last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.net.if.operstatus[{#SNMPINDEX}],#2)`<p>Recovery expression:</p>`last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.net.if.operstatus[{#SNMPINDEX}])<>2` |AVERAGE |<p>Manual close: YES</p> | -|ZYXEL MES3500-24: SFP {#SNMPINDEX} has been replaced |<p>SFP {#SNMPINDEX} serial number has changed. Ack to close</p> |`last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.sfp.serialnumber[{#SNMPINDEX}],#1)<>last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.sfp.serialnumber[{#SNMPINDEX}],#2) and length(last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.sfp.serialnumber[{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> | -|ZYXEL MES3500-24: SFP {#ZYXEL.SFP.PORT}: High {#ZYXEL.SFP.DESCRIPTION} |<p>The upper threshold value of the parameter is exceeded</p> |`last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.sfp.ddm[{#SNMPINDEX}]) > {#ZYXEL.SFP.WARN.MAX}` |WARNING | | -|ZYXEL MES3500-24: SFP {#ZYXEL.SFP.PORT}: Low {#ZYXEL.SFP.DESCRIPTION} |<p>The parameter values are less than the lower threshold</p> |`last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.sfp.ddm[{#SNMPINDEX}]) < {#ZYXEL.SFP.WARN.MIN}` |WARNING | | -|ZYXEL MES3500-24: Voltage {#ZYXEL.VOLT.NOMINAL} is in critical state |<p>Please check the power supply</p> |`last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.volt[{#SNMPINDEX}])<{#ZYXEL.VOLT.THRESH.LOW}` |AVERAGE | | -|ZYXEL MES3500-24: No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/ZYXEL MES3500-24 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | -|ZYXEL MES3500-24: Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.hw.uptime)>0 and last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.hw.uptime)<10m) or (last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.hw.uptime)=0 and last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.net.uptime)<10m)` |INFO |<p>Manual close: YES</p> | -|ZYXEL MES3500-24: Temperature {#ZYXEL.TEMP.ID} is in critical state |<p>Please check the temperature</p> |`last(/ZYXEL MES3500-24 SNMP/zyxel.3500_24.temp[{#SNMPINDEX}])>{#ZYXEL.TEMP.THRESH.HIGH}` |AVERAGE | | +|ZYXEL MES3500-24: High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.cpuusage,5m)>{$CPU.UTIL.CRIT}` |WARNING | | +|ZYXEL MES3500-24: Template does not match hardware |<p>This template is for Zyxel MES3500-24, but connected to {ITEM.VALUE}</p> |`last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.model)<>"MES3500-24"` |INFO | | +|ZYXEL MES3500-24: Firmware has changed |<p>Firmware version has changed. Ack to close</p> |`last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.fwversion,#1)<>last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.fwversion,#2) and length(last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.fwversion))>0` |INFO |<p>Manual close: YES</p> | +|ZYXEL MES3500-24: Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.serialnumber,#1)<>last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.serialnumber,#2) and length(last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.serialnumber))>0` |INFO |<p>Manual close: YES</p> | +|ZYXEL MES3500-24: High memory utilization in "{#ZYXEL.MEMORY.NAME}" pool |<p>The system is running out of free memory.</p> |`min(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.memory[{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | | +|ZYXEL MES3500-24: Port {#SNMPINDEX}: Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.net.if.operstatus[{#SNMPINDEX}])=2 and last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.net.if.operstatus[{#SNMPINDEX}],#1)<>last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.net.if.operstatus[{#SNMPINDEX}],#2)`<p>Recovery expression:</p>`last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.net.if.operstatus[{#SNMPINDEX}])<>2` |AVERAGE |<p>Manual close: YES</p> | +|ZYXEL MES3500-24: SFP {#SNMPINDEX} has been replaced |<p>SFP {#SNMPINDEX} serial number has changed. Ack to close</p> |`last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.sfp.serialnumber[{#SNMPINDEX}],#1)<>last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.sfp.serialnumber[{#SNMPINDEX}],#2) and length(last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.sfp.serialnumber[{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> | +|ZYXEL MES3500-24: SFP {#ZYXEL.SFP.PORT}: High {#ZYXEL.SFP.DESCRIPTION} |<p>The upper threshold value of the parameter is exceeded</p> |`last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.sfp.ddm[{#SNMPINDEX}]) > {#ZYXEL.SFP.WARN.MAX}` |WARNING | | +|ZYXEL MES3500-24: SFP {#ZYXEL.SFP.PORT}: Low {#ZYXEL.SFP.DESCRIPTION} |<p>The parameter values are less than the lower threshold</p> |`last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.sfp.ddm[{#SNMPINDEX}]) < {#ZYXEL.SFP.WARN.MIN}` |WARNING | | +|ZYXEL MES3500-24: Voltage {#ZYXEL.VOLT.NOMINAL} is in critical state |<p>Please check the power supply</p> |`last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.volt[{#SNMPINDEX}])<{#ZYXEL.VOLT.THRESH.LOW}` |AVERAGE | | +|ZYXEL MES3500-24: No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/ZYXEL MES3500-24 by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | | +|ZYXEL MES3500-24: Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.hw.uptime)>0 and last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.hw.uptime)<10m) or (last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.hw.uptime)=0 and last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.net.uptime)<10m)` |INFO |<p>Manual close: YES</p> | +|ZYXEL MES3500-24: Temperature {#ZYXEL.TEMP.ID} is in critical state |<p>Please check the temperature</p> |`last(/ZYXEL MES3500-24 by SNMP/zyxel.3500_24.temp[{#SNMPINDEX}])>{#ZYXEL.TEMP.THRESH.HIGH}` |AVERAGE | | ## Feedback -Please report any issues with the template at https://support.zabbix.com +Please report any issues with the template at https://support.zabbix.com. -You can also provide feedback, discuss the template or ask for help with it at [ZABBIX forums](https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/422668-discussion-thread-for-official-zabbix-templates-for-zyxel). +You can also provide feedback, discuss the template, or ask for help at [ZABBIX forums](https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/422668-discussion-thread-for-official-zabbix-templates-for-zyxel). ## Known Issues |