diff options
Diffstat (limited to 'templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml')
-rw-r--r-- | templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml | 216 |
1 files changed, 172 insertions, 44 deletions
diff --git a/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml b/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml index b5a7baac001..5e23aeb8b8d 100644 --- a/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml +++ b/templates/power/apc/apc_ups_smart_rt_1000_rm_xl_snmp/template_power_apc_ups_smart_rt_1000_rm_xl_snmp.yaml @@ -1,6 +1,6 @@ zabbix_export: version: '6.4' - date: '2022-08-16T10:56:54Z' + date: '2022-10-27T14:24:38Z' template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 @@ -8,8 +8,8 @@ zabbix_export: templates: - uuid: 340ec6917c274ead8fab36925e57f30a - template: 'APC Smart-UPS RT 1000 RM XL SNMP' - name: 'APC Smart-UPS RT 1000 RM XL SNMP' + template: 'APC Smart-UPS RT 1000 RM XL by SNMP' + name: 'APC Smart-UPS RT 1000 RM XL by SNMP' description: | Template Power APC Smart-UPS RT 1000 RM XL @@ -54,7 +54,7 @@ zabbix_export: triggers: - uuid: 8ab182b26a0443539a1a114767d8acd7 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/battery.capacity[upsHighPrecBatteryCapacity]) < {$BATTERY.CAPACITY.MIN.WARN}' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/battery.capacity[upsHighPrecBatteryCapacity]) < {$BATTERY.CAPACITY.MIN.WARN}' name: 'Battery has low capacity' event_name: 'Battery has low capacity (below {$BATTERY.CAPACITY.MIN.WARN}%)' opdata: 'Current capacity: {ITEM.LASTVALUE1}' @@ -135,7 +135,7 @@ zabbix_export: triggers: - uuid: ab0db1327cf04a9c9a9ee757f0869603 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/battery.replace_indicator[upsAdvBatteryReplaceIndicator])=2' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/battery.replace_indicator[upsAdvBatteryReplaceIndicator])=2' name: 'Battery needs replacement' priority: HIGH description: 'A battery installed has an internal error condition.' @@ -202,7 +202,7 @@ zabbix_export: triggers: - uuid: c8787a09c2ea4aeb977b868ae0a3218b - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/battery.status[upsBasicBatteryStatus])=4' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/battery.status[upsBasicBatteryStatus])=4' name: 'Battery has an internal error condition' priority: AVERAGE description: 'A battery installed has an internal error condition.' @@ -212,7 +212,7 @@ zabbix_export: value: notice - uuid: 40d1fdcec63d4c3785b5ba77fbd14ee7 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/battery.status[upsBasicBatteryStatus])=3' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/battery.status[upsBasicBatteryStatus])=3' name: 'Battery is Low' priority: AVERAGE description: 'The UPS will be unable to sustain the current load, and its services will be lost if power is not restored.' @@ -249,7 +249,7 @@ zabbix_export: triggers: - uuid: e2debe06675d4d4584b60b768633887b - expression: 'min(/APC Smart-UPS RT 1000 RM XL SNMP/battery.temperature[upsHighPrecBatteryTemperature],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}' + expression: 'min(/APC Smart-UPS RT 1000 RM XL by SNMP/battery.temperature[upsHighPrecBatteryTemperature],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}' name: 'Battery has high temperature' event_name: 'Battery has high temperature (over {$BATTERY.TEMP.MAX.WARN}℃ for {$TIME.PERIOD})' opdata: 'Current temperature: {ITEM.LASTVALUE1}' @@ -355,7 +355,7 @@ zabbix_export: triggers: - uuid: b29cd7e33c1e4e16b10fe436c1f7e6d6 - expression: 'min(/APC Smart-UPS RT 1000 RM XL SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > 0 and (min(/APC Smart-UPS RT 1000 RM XL SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > {$UPS.INPUT_FREQ.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) < {$UPS.INPUT_FREQ.MIN.WARN})' + expression: 'min(/APC Smart-UPS RT 1000 RM XL by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > 0 and (min(/APC Smart-UPS RT 1000 RM XL by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > {$UPS.INPUT_FREQ.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) < {$UPS.INPUT_FREQ.MIN.WARN})' name: 'Unacceptable input frequency' event_name: 'Unacceptable input frequency (out of range {$UPS.INPUT_FREQ.MIN.WARN}-{$UPS.INPUT_FREQ.MAX.WARN}Hz for {$TIME.PERIOD})' opdata: 'Current frequency: {ITEM.LASTVALUE1}' @@ -392,7 +392,7 @@ zabbix_export: triggers: - uuid: d38f2151f0eb486e8d44b72a2e361a5f - expression: 'min(/APC Smart-UPS RT 1000 RM XL SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > 0 and (min(/APC Smart-UPS RT 1000 RM XL SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN})' + expression: 'min(/APC Smart-UPS RT 1000 RM XL by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > 0 and (min(/APC Smart-UPS RT 1000 RM XL by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN})' name: 'Unacceptable input voltage' event_name: 'Unacceptable input voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})' opdata: 'Current voltage: {ITEM.LASTVALUE1}' @@ -455,7 +455,7 @@ zabbix_export: triggers: - uuid: 57197c601f8a433d8ccdcb040d047f6f - expression: 'min(/APC Smart-UPS RT 1000 RM XL SNMP/output.load[upsHighPrecOutputLoad],{$TIME.PERIOD}) > {$UPS.OUTPUT.MAX.WARN}' + expression: 'min(/APC Smart-UPS RT 1000 RM XL by SNMP/output.load[upsHighPrecOutputLoad],{$TIME.PERIOD}) > {$UPS.OUTPUT.MAX.WARN}' name: 'Output load is high' event_name: 'Output load is high (over {$UPS.OUTPUT.MAX.WARN}% for {$TIME.PERIOD})' opdata: 'Current load: {ITEM.LASTVALUE1}' @@ -498,7 +498,7 @@ zabbix_export: triggers: - uuid: e9289d8f4e124097990e2af98e916368 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=16' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=16' name: 'UPS is Emergency Static Bypass' priority: AVERAGE tags: @@ -507,7 +507,7 @@ zabbix_export: value: notice - uuid: 13735964f51d4d1bb17e6b0587a43020 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=10' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=10' name: 'UPS is Hardware Failure Bypass' priority: AVERAGE tags: @@ -516,7 +516,7 @@ zabbix_export: value: notice - uuid: d74ae82199884a7fb4a20b48f3c7ff1f - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=7' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=7' name: 'UPS is Off' priority: AVERAGE tags: @@ -525,7 +525,7 @@ zabbix_export: value: notice - uuid: 4df5271075904c228a0372d5f667530e - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=3' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=3' name: 'UPS is on battery' priority: AVERAGE tags: @@ -534,7 +534,7 @@ zabbix_export: value: notice - uuid: 3f02d9cb7f5142599e59e7781808e5c3 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=4' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=4' name: 'UPS is on Smart Boost' priority: AVERAGE tags: @@ -543,7 +543,7 @@ zabbix_export: value: notice - uuid: 515ad03892694fd4a2f2350a6bb8af6f - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=12' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=12' name: 'UPS is On Smart Trim' priority: AVERAGE tags: @@ -552,7 +552,7 @@ zabbix_export: value: notice - uuid: 2a2d35e4e4674b6aa49068a7970caa03 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=8' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=8' name: 'UPS is Rebooting' priority: AVERAGE tags: @@ -561,7 +561,7 @@ zabbix_export: value: notice - uuid: ef1ddb8869074847b70e8f669883c56b - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=11' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=11' name: 'UPS is Sleeping Until Power Return' priority: AVERAGE tags: @@ -570,7 +570,7 @@ zabbix_export: value: notice - uuid: 0d6e4e664ddf425e8c03155802fe45be - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=6' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=6' name: 'UPS is Software Bypass' priority: AVERAGE tags: @@ -579,7 +579,7 @@ zabbix_export: value: notice - uuid: 12a3a33152824ffe863a8d79c1372195 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=9' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=9' name: 'UPS is Switched Bypass' priority: AVERAGE tags: @@ -588,7 +588,7 @@ zabbix_export: value: notice - uuid: 273c561c2afb4d78be86218e370c9a1f - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/output.status[upsBasicOutputStatus])=5' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/output.status[upsBasicOutputStatus])=5' name: 'UPS is Timed Sleeping' priority: AVERAGE tags: @@ -788,7 +788,7 @@ zabbix_export: triggers: - uuid: b13b087b9828426aac82a281071ceb8b - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/system.name[sysName.0],#1)<>last(/APC Smart-UPS RT 1000 RM XL SNMP/system.name[sysName.0],#2) and length(last(/APC Smart-UPS RT 1000 RM XL SNMP/system.name[sysName.0]))>0' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/system.name[sysName.0],#1)<>last(/APC Smart-UPS RT 1000 RM XL by SNMP/system.name[sysName.0],#2) and length(last(/APC Smart-UPS RT 1000 RM XL by SNMP/system.name[sysName.0]))>0' name: 'System name has changed' event_name: 'System name has changed (new name: {ITEM.VALUE})' priority: INFO @@ -905,7 +905,7 @@ zabbix_export: triggers: - uuid: 53263bf0536d479785b45883b9b7ab21 - expression: 'max(/APC Smart-UPS RT 1000 RM XL SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' + expression: 'max(/APC Smart-UPS RT 1000 RM XL by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING @@ -1021,7 +1021,7 @@ zabbix_export: trigger_prototypes: - uuid: c1eefbeeb0d146c3bea5cae929d0c30b - expression: 'find(/APC Smart-UPS RT 1000 RM XL SNMP/battery.pack.cartridge_health[upsHighPrecBatteryPackCartridgeHealth.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0)[0|1]{15}$")=1' + expression: 'find(/APC Smart-UPS RT 1000 RM XL by SNMP/battery.pack.cartridge_health[upsHighPrecBatteryPackCartridgeHealth.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0)[0|1]{15}$")=1' name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery lifetime is not okay' opdata: 'Current bit set: {ITEM.LASTVALUE1}' priority: WARNING @@ -1077,7 +1077,7 @@ zabbix_export: trigger_prototypes: - uuid: 28b8fb69a85549288cf0e26b9ca0a2cf - expression: 'find(/APC Smart-UPS RT 1000 RM XL SNMP/battery.pack.status[upsHighPrecBatteryPackCartridgeStatus.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0{16})$")=0' + expression: 'find(/APC Smart-UPS RT 1000 RM XL by SNMP/battery.pack.status[upsHighPrecBatteryPackCartridgeStatus.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0{16})$")=0' name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery status is not okay' opdata: 'Current bit set: {ITEM.LASTVALUE1}' priority: WARNING @@ -1127,7 +1127,7 @@ zabbix_export: trigger_prototypes: - uuid: fa007fcfbe7c499d8f97a808991f2800 - expression: 'min(/APC Smart-UPS RT 1000 RM XL SNMP/battery.temperature[upsHighPrecBatteryPackTemperature.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}' + expression: 'min(/APC Smart-UPS RT 1000 RM XL by SNMP/battery.temperature[upsHighPrecBatteryPackTemperature.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}' name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery has high temperature' event_name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery has high temperature (over {$BATTERY.TEMP.MAX.WARN}℃ for {$TIME.PERIOD})' opdata: 'Current temperature: {ITEM.LASTVALUE1}' @@ -1224,7 +1224,7 @@ zabbix_export: trigger_prototypes: - uuid: 175c1def62ac412eb5f9ef015a9b8ac3 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=3' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=3' name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Critical' priority: HIGH description: 'The external sensor has returned a value greater than the critical threshold.' @@ -1234,7 +1234,7 @@ zabbix_export: value: notice - uuid: e7610cf822674591bea6ed7ba5e4198d - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=4' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=4' name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Not Applicable' priority: INFO description: 'The external sensor does not work or is not connected.' @@ -1244,7 +1244,7 @@ zabbix_export: value: notice - uuid: 44353bbfcfbe42e59d2e58b544d32b43 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=2' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=2' name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Warning' priority: AVERAGE description: 'The external sensor has returned a value greater than the warning threshold.' @@ -1292,7 +1292,6 @@ zabbix_export: operationobject: ITEM_PROTOTYPE operator: LIKE value: Humidity - status: ENABLED discover: NO_DISCOVER - uuid: d4b34302c7d74f83a409947f2eed37b0 @@ -1360,7 +1359,7 @@ zabbix_export: trigger_prototypes: - uuid: 5e937c991aa146fe98c1a4f868be6b70 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=3' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=3' name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Critical' priority: HIGH description: 'The external sensor has returned a value greater than the critical threshold.' @@ -1370,7 +1369,7 @@ zabbix_export: value: notice - uuid: f8dd227322784a708ae6297e796177f9 - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=4' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=4' name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Not Applicable' priority: INFO description: 'The external sensor does not work or is not connected.' @@ -1380,7 +1379,7 @@ zabbix_export: value: notice - uuid: b142607d33e9447d88f23fc3ff7dc11d - expression: 'last(/APC Smart-UPS RT 1000 RM XL SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=2' + expression: 'last(/APC Smart-UPS RT 1000 RM XL by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=2' name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Warning' priority: AVERAGE description: 'The external sensor has returned a value greater than the warning threshold.' @@ -1428,7 +1427,6 @@ zabbix_export: operationobject: ITEM_PROTOTYPE operator: LIKE value: Humidity - status: ENABLED discover: NO_DISCOVER - uuid: 525a204918834dbfa788a3681c2d0527 @@ -1490,7 +1488,7 @@ zabbix_export: trigger_prototypes: - uuid: 971301abf4d6457da125fd7ebd903728 - expression: 'min(/APC Smart-UPS RT 1000 RM XL SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}' + expression: 'min(/APC Smart-UPS RT 1000 RM XL by SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL by SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}' name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage' event_name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})' opdata: 'Current phase {#PHASEINDEX} voltage: {ITEM.LASTVALUE1}' @@ -1583,7 +1581,7 @@ zabbix_export: trigger_prototypes: - uuid: d7167a129de146d19218edb85c82c69b - expression: 'min(/APC Smart-UPS RT 1000 RM XL SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}' + expression: 'min(/APC Smart-UPS RT 1000 RM XL by SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS RT 1000 RM XL by SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}' name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage' event_name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})' opdata: 'Current phase {#PHASEINDEX} voltage: {ITEM.LASTVALUE1}' @@ -1639,6 +1637,136 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' + dashboards: + - + uuid: 2fba6e227f9b4d8fa584664bfd600cf4 + name: 'UPS Summary' + pages: + - + widgets: + - + type: PLAIN_TEXT + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' + key: 'system.net.uptime[sysUpTime.0]' + - + type: PLAIN_TEXT + x: '8' + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' + key: 'input.fail[upsAdvInputLineFailCause]' + - + type: PLAIN_TEXT + x: '16' + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' + key: 'output.status[upsBasicOutputStatus]' + - + type: PLAIN_TEXT + 'y': '5' + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' + key: 'battery.status[upsBasicBatteryStatus]' + - + type: PLAIN_TEXT + x: '8' + 'y': '5' + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' + key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' + - + type: PLAIN_TEXT + x: '16' + 'y': '5' + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' + key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' + - + type: GRAPH_CLASSIC + 'y': '10' + width: '8' + height: '5' + fields: + - + type: INTEGER + name: source_type + value: '0' + - + type: GRAPH + name: graphid + value: + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' + name: 'Capacity of the UPS batteries' + - + type: GRAPH_CLASSIC + x: '8' + 'y': '10' + width: '8' + height: '5' + fields: + - + type: INTEGER + name: source_type + value: '0' + - + type: GRAPH + name: graphid + value: + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' + name: Voltage + - + type: GRAPH_CLASSIC + x: '16' + 'y': '10' + width: '8' + height: '5' + fields: + - + type: INTEGER + name: source_type + value: '0' + - + type: GRAPH + name: graphid + value: + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' + name: Output valuemaps: - uuid: 7cf932d3b9304f2cb151134e9ea3be82 @@ -1814,7 +1942,7 @@ zabbix_export: triggers: - uuid: 87ebd137f2744ae6879d6fd9d51314ef - expression: '(last(/APC Smart-UPS RT 1000 RM XL SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/APC Smart-UPS RT 1000 RM XL SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/APC Smart-UPS RT 1000 RM XL SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/APC Smart-UPS RT 1000 RM XL SNMP/system.net.uptime[sysUpTime.0])<10m)' + expression: '(last(/APC Smart-UPS RT 1000 RM XL by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/APC Smart-UPS RT 1000 RM XL by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/APC Smart-UPS RT 1000 RM XL by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/APC Smart-UPS RT 1000 RM XL by SNMP/system.net.uptime[sysUpTime.0])<10m)' name: 'Host has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING @@ -1823,7 +1951,7 @@ zabbix_export: dependencies: - name: 'No SNMP data collection' - expression: 'max(/APC Smart-UPS RT 1000 RM XL SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' + expression: 'max(/APC Smart-UPS RT 1000 RM XL by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' tags: - tag: scope @@ -1837,7 +1965,7 @@ zabbix_export: - color: 1A7C11 item: - host: 'APC Smart-UPS RT 1000 RM XL SNMP' + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' key: 'battery.capacity[upsHighPrecBatteryCapacity]' - uuid: 09da5776f4ff4e978e488a12f33dc8bc @@ -1846,13 +1974,13 @@ zabbix_export: - color: 1A7C11 item: - host: 'APC Smart-UPS RT 1000 RM XL SNMP' + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' key: 'output.current[upsHighPrecOutputCurrent]' - sortorder: '1' color: 2774A4 item: - host: 'APC Smart-UPS RT 1000 RM XL SNMP' + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' key: 'output.load[upsHighPrecOutputLoad]' - uuid: df0833759bae450e8125c3fb76519775 @@ -1861,11 +1989,11 @@ zabbix_export: - color: 1A7C11 item: - host: 'APC Smart-UPS RT 1000 RM XL SNMP' + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' key: 'input.voltage[upsHighPrecInputLineVoltage]' - sortorder: '1' color: 2774A4 item: - host: 'APC Smart-UPS RT 1000 RM XL SNMP' + host: 'APC Smart-UPS RT 1000 RM XL by SNMP' key: 'output.voltage[upsHighPrecOutputVoltage]' |