diff options
Diffstat (limited to 'templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml')
-rw-r--r-- | templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml | 216 |
1 files changed, 172 insertions, 44 deletions
diff --git a/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml b/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml index 8918c875069..f4967b3fdfc 100644 --- a/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml +++ b/templates/power/apc/apc_ups_symmetra_lx_snmp/template_power_apc_ups_symmetra_lx_snmp.yaml @@ -1,6 +1,6 @@ zabbix_export: version: '6.4' - date: '2022-08-16T10:56:59Z' + date: '2022-10-27T14:24:42Z' template_groups: - uuid: 3dcd5bbe90534f9e8eb5c2d53756af63 @@ -8,8 +8,8 @@ zabbix_export: templates: - uuid: 0b9a899ff8f1467c9fdf999d02b9fd77 - template: 'APC UPS Symmetra LX SNMP' - name: 'APC UPS Symmetra LX SNMP' + template: 'APC UPS Symmetra LX by SNMP' + name: 'APC UPS Symmetra LX by SNMP' description: | Template Power APC UPS Symmetra LX @@ -54,7 +54,7 @@ zabbix_export: triggers: - uuid: fdece80f2fc44ac1974fafe190ce186f - expression: 'last(/APC UPS Symmetra LX SNMP/battery.capacity[upsHighPrecBatteryCapacity]) < {$BATTERY.CAPACITY.MIN.WARN}' + expression: 'last(/APC UPS Symmetra LX by SNMP/battery.capacity[upsHighPrecBatteryCapacity]) < {$BATTERY.CAPACITY.MIN.WARN}' name: 'Battery has low capacity' event_name: 'Battery has low capacity (below {$BATTERY.CAPACITY.MIN.WARN}%)' opdata: 'Current capacity: {ITEM.LASTVALUE1}' @@ -135,7 +135,7 @@ zabbix_export: triggers: - uuid: a1bd434a249b48b2ac0ef69ede417a72 - expression: 'last(/APC UPS Symmetra LX SNMP/battery.replace_indicator[upsAdvBatteryReplaceIndicator])=2' + expression: 'last(/APC UPS Symmetra LX by SNMP/battery.replace_indicator[upsAdvBatteryReplaceIndicator])=2' name: 'Battery needs replacement' priority: HIGH description: 'A battery installed has an internal error condition.' @@ -202,7 +202,7 @@ zabbix_export: triggers: - uuid: 955d79a0cf5447dd9a11d4608758e983 - expression: 'last(/APC UPS Symmetra LX SNMP/battery.status[upsBasicBatteryStatus])=4' + expression: 'last(/APC UPS Symmetra LX by SNMP/battery.status[upsBasicBatteryStatus])=4' name: 'Battery has an internal error condition' priority: AVERAGE description: 'A battery installed has an internal error condition.' @@ -212,7 +212,7 @@ zabbix_export: value: notice - uuid: 3ca8156ecc1c4ee4b5623c4a085b993f - expression: 'last(/APC UPS Symmetra LX SNMP/battery.status[upsBasicBatteryStatus])=3' + expression: 'last(/APC UPS Symmetra LX by SNMP/battery.status[upsBasicBatteryStatus])=3' name: 'Battery is Low' priority: AVERAGE description: 'The UPS will be unable to sustain the current load, and its services will be lost if power is not restored.' @@ -249,7 +249,7 @@ zabbix_export: triggers: - uuid: 5b43659a10644a51861282bc72116f9f - expression: 'min(/APC UPS Symmetra LX SNMP/battery.temperature[upsHighPrecBatteryTemperature],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}' + expression: 'min(/APC UPS Symmetra LX by SNMP/battery.temperature[upsHighPrecBatteryTemperature],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}' name: 'Battery has high temperature' event_name: 'Battery has high temperature (over {$BATTERY.TEMP.MAX.WARN}℃ for {$TIME.PERIOD})' opdata: 'Current temperature: {ITEM.LASTVALUE1}' @@ -355,7 +355,7 @@ zabbix_export: triggers: - uuid: 94a5c26b89e2416f96b61bbfc6e60a97 - expression: 'min(/APC UPS Symmetra LX SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > 0 and (min(/APC UPS Symmetra LX SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > {$UPS.INPUT_FREQ.MAX.WARN} or max(/APC UPS Symmetra LX SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) < {$UPS.INPUT_FREQ.MIN.WARN})' + expression: 'min(/APC UPS Symmetra LX by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > 0 and (min(/APC UPS Symmetra LX by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > {$UPS.INPUT_FREQ.MAX.WARN} or max(/APC UPS Symmetra LX by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) < {$UPS.INPUT_FREQ.MIN.WARN})' name: 'Unacceptable input frequency' event_name: 'Unacceptable input frequency (out of range {$UPS.INPUT_FREQ.MIN.WARN}-{$UPS.INPUT_FREQ.MAX.WARN}Hz for {$TIME.PERIOD})' opdata: 'Current frequency: {ITEM.LASTVALUE1}' @@ -392,7 +392,7 @@ zabbix_export: triggers: - uuid: 2b640b94d48446609802ce6e57c7bd46 - expression: 'min(/APC UPS Symmetra LX SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > 0 and (min(/APC UPS Symmetra LX SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN})' + expression: 'min(/APC UPS Symmetra LX by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > 0 and (min(/APC UPS Symmetra LX by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN})' name: 'Unacceptable input voltage' event_name: 'Unacceptable input voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})' opdata: 'Current voltage: {ITEM.LASTVALUE1}' @@ -455,7 +455,7 @@ zabbix_export: triggers: - uuid: 34562b5c734d492c89c386902dfd6e90 - expression: 'min(/APC UPS Symmetra LX SNMP/output.load[upsHighPrecOutputLoad],{$TIME.PERIOD}) > {$UPS.OUTPUT.MAX.WARN}' + expression: 'min(/APC UPS Symmetra LX by SNMP/output.load[upsHighPrecOutputLoad],{$TIME.PERIOD}) > {$UPS.OUTPUT.MAX.WARN}' name: 'Output load is high' event_name: 'Output load is high (over {$UPS.OUTPUT.MAX.WARN}% for {$TIME.PERIOD})' opdata: 'Current load: {ITEM.LASTVALUE1}' @@ -498,7 +498,7 @@ zabbix_export: triggers: - uuid: 6ade2b9fb9ad432596d16b3df6237ec4 - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=16' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=16' name: 'UPS is Emergency Static Bypass' priority: AVERAGE tags: @@ -507,7 +507,7 @@ zabbix_export: value: notice - uuid: da9a0fa7669e454b8ba44c0458a94ea8 - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=10' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=10' name: 'UPS is Hardware Failure Bypass' priority: AVERAGE tags: @@ -516,7 +516,7 @@ zabbix_export: value: notice - uuid: 01a2bcb5f20b4fe889a48e4bed2a2a63 - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=7' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=7' name: 'UPS is Off' priority: AVERAGE tags: @@ -525,7 +525,7 @@ zabbix_export: value: notice - uuid: d0b154dd92424af8bb841d91d4e7ddd5 - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=3' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=3' name: 'UPS is on battery' priority: AVERAGE tags: @@ -534,7 +534,7 @@ zabbix_export: value: notice - uuid: afc071d0ccfb4226a3c5ee3058270937 - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=4' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=4' name: 'UPS is on Smart Boost' priority: AVERAGE tags: @@ -543,7 +543,7 @@ zabbix_export: value: notice - uuid: 12259f4a961a40b39de12d0202d41c56 - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=12' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=12' name: 'UPS is On Smart Trim' priority: AVERAGE tags: @@ -552,7 +552,7 @@ zabbix_export: value: notice - uuid: ef9d1e4b1ec244f6bcf36d19a9e7c9c7 - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=8' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=8' name: 'UPS is Rebooting' priority: AVERAGE tags: @@ -561,7 +561,7 @@ zabbix_export: value: notice - uuid: c673928e7b764b5db0fa3168edd2cc67 - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=11' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=11' name: 'UPS is Sleeping Until Power Return' priority: AVERAGE tags: @@ -570,7 +570,7 @@ zabbix_export: value: notice - uuid: c9b24aa16e124d8c9cd6cfb188ded816 - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=6' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=6' name: 'UPS is Software Bypass' priority: AVERAGE tags: @@ -579,7 +579,7 @@ zabbix_export: value: notice - uuid: 02904426801d4d42b3f634267f8697e7 - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=9' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=9' name: 'UPS is Switched Bypass' priority: AVERAGE tags: @@ -588,7 +588,7 @@ zabbix_export: value: notice - uuid: fa08f8a60c2c4d88a3f9ebf317fcd06e - expression: 'last(/APC UPS Symmetra LX SNMP/output.status[upsBasicOutputStatus])=5' + expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=5' name: 'UPS is Timed Sleeping' priority: AVERAGE tags: @@ -788,7 +788,7 @@ zabbix_export: triggers: - uuid: 61d0836efd33437894e1edd595373f1e - expression: 'last(/APC UPS Symmetra LX SNMP/system.name[sysName.0],#1)<>last(/APC UPS Symmetra LX SNMP/system.name[sysName.0],#2) and length(last(/APC UPS Symmetra LX SNMP/system.name[sysName.0]))>0' + expression: 'last(/APC UPS Symmetra LX by SNMP/system.name[sysName.0],#1)<>last(/APC UPS Symmetra LX by SNMP/system.name[sysName.0],#2) and length(last(/APC UPS Symmetra LX by SNMP/system.name[sysName.0]))>0' name: 'System name has changed' event_name: 'System name has changed (new name: {ITEM.VALUE})' priority: INFO @@ -905,7 +905,7 @@ zabbix_export: triggers: - uuid: aeaaa7e2bd2d46a481f9d8b33ec18cb5 - expression: 'max(/APC UPS Symmetra LX SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' + expression: 'max(/APC UPS Symmetra LX by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING @@ -1021,7 +1021,7 @@ zabbix_export: trigger_prototypes: - uuid: 2ea1a8d2bd3746dabafed72e1f6216fd - expression: 'find(/APC UPS Symmetra LX SNMP/battery.pack.cartridge_health[upsHighPrecBatteryPackCartridgeHealth.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0)[0|1]{15}$")=1' + expression: 'find(/APC UPS Symmetra LX by SNMP/battery.pack.cartridge_health[upsHighPrecBatteryPackCartridgeHealth.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0)[0|1]{15}$")=1' name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery lifetime is not okay' opdata: 'Current bit set: {ITEM.LASTVALUE1}' priority: WARNING @@ -1077,7 +1077,7 @@ zabbix_export: trigger_prototypes: - uuid: 3870634ad8c1414dabeebc10c510fba3 - expression: 'find(/APC UPS Symmetra LX SNMP/battery.pack.status[upsHighPrecBatteryPackCartridgeStatus.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0{16})$")=0' + expression: 'find(/APC UPS Symmetra LX by SNMP/battery.pack.status[upsHighPrecBatteryPackCartridgeStatus.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0{16})$")=0' name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery status is not okay' opdata: 'Current bit set: {ITEM.LASTVALUE1}' priority: WARNING @@ -1127,7 +1127,7 @@ zabbix_export: trigger_prototypes: - uuid: 730bdb68d90f4bc6aaf6cb22e04e1845 - expression: 'min(/APC UPS Symmetra LX SNMP/battery.temperature[upsHighPrecBatteryPackTemperature.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}' + expression: 'min(/APC UPS Symmetra LX by SNMP/battery.temperature[upsHighPrecBatteryPackTemperature.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}' name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery has high temperature' event_name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery has high temperature (over {$BATTERY.TEMP.MAX.WARN}℃ for {$TIME.PERIOD})' opdata: 'Current temperature: {ITEM.LASTVALUE1}' @@ -1224,7 +1224,7 @@ zabbix_export: trigger_prototypes: - uuid: 97b4078788d244d0b501e9465c659ff7 - expression: 'last(/APC UPS Symmetra LX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=3' + expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=3' name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Critical' priority: HIGH description: 'The external sensor has returned a value greater than the critical threshold.' @@ -1234,7 +1234,7 @@ zabbix_export: value: notice - uuid: 86cd9908372045618672d6ff82bca705 - expression: 'last(/APC UPS Symmetra LX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=4' + expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=4' name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Not Applicable' priority: INFO description: 'The external sensor does not work or is not connected.' @@ -1244,7 +1244,7 @@ zabbix_export: value: notice - uuid: 4ba13efc27da411785410109340b6a26 - expression: 'last(/APC UPS Symmetra LX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=2' + expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=2' name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Warning' priority: AVERAGE description: 'The external sensor has returned a value greater than the warning threshold.' @@ -1292,7 +1292,6 @@ zabbix_export: operationobject: ITEM_PROTOTYPE operator: LIKE value: Humidity - status: ENABLED discover: NO_DISCOVER - uuid: 14e6acae826e4e87b68c04beee67a5cb @@ -1360,7 +1359,7 @@ zabbix_export: trigger_prototypes: - uuid: 3155c8cf446c40d896755a25a46ec90b - expression: 'last(/APC UPS Symmetra LX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=3' + expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=3' name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Critical' priority: HIGH description: 'The external sensor has returned a value greater than the critical threshold.' @@ -1370,7 +1369,7 @@ zabbix_export: value: notice - uuid: 9ef9a4dc80c84087b44b5f0e8aa94202 - expression: 'last(/APC UPS Symmetra LX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=4' + expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=4' name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Not Applicable' priority: INFO description: 'The external sensor does not work or is not connected.' @@ -1380,7 +1379,7 @@ zabbix_export: value: notice - uuid: 74a3585b0cc74a4887eb3683fb1e6f64 - expression: 'last(/APC UPS Symmetra LX SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=2' + expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=2' name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Warning' priority: AVERAGE description: 'The external sensor has returned a value greater than the warning threshold.' @@ -1428,7 +1427,6 @@ zabbix_export: operationobject: ITEM_PROTOTYPE operator: LIKE value: Humidity - status: ENABLED discover: NO_DISCOVER - uuid: b4f271299e9a47bf8543863a7d9be479 @@ -1490,7 +1488,7 @@ zabbix_export: trigger_prototypes: - uuid: 90e3258375e047b594deb0ecf7300c22 - expression: 'min(/APC UPS Symmetra LX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}' + expression: 'min(/APC UPS Symmetra LX by SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX by SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}' name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage' event_name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})' opdata: 'Current phase {#PHASEINDEX} voltage: {ITEM.LASTVALUE1}' @@ -1583,7 +1581,7 @@ zabbix_export: trigger_prototypes: - uuid: b8c42d5d66d9403eba697920439ae956 - expression: 'min(/APC UPS Symmetra LX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}' + expression: 'min(/APC UPS Symmetra LX by SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX by SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}' name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage' event_name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})' opdata: 'Current phase {#PHASEINDEX} voltage: {ITEM.LASTVALUE1}' @@ -1639,6 +1637,136 @@ zabbix_export: macro: '{$UPS.OUTPUT.MAX.WARN}' value: '80' description: 'Maximum output load in % for trigger expression.' + dashboards: + - + uuid: fbf5cb79251d48bdbe4bc7b81dbd2d65 + name: 'UPS Summary' + pages: + - + widgets: + - + type: PLAIN_TEXT + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC UPS Symmetra LX by SNMP' + key: 'system.net.uptime[sysUpTime.0]' + - + type: PLAIN_TEXT + x: '8' + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC UPS Symmetra LX by SNMP' + key: 'input.fail[upsAdvInputLineFailCause]' + - + type: PLAIN_TEXT + x: '16' + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC UPS Symmetra LX by SNMP' + key: 'output.status[upsBasicOutputStatus]' + - + type: PLAIN_TEXT + 'y': '5' + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC UPS Symmetra LX by SNMP' + key: 'battery.status[upsBasicBatteryStatus]' + - + type: PLAIN_TEXT + x: '8' + 'y': '5' + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC UPS Symmetra LX by SNMP' + key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]' + - + type: PLAIN_TEXT + x: '16' + 'y': '5' + width: '8' + height: '5' + fields: + - + type: ITEM + name: itemids + value: + host: 'APC UPS Symmetra LX by SNMP' + key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]' + - + type: GRAPH_CLASSIC + 'y': '10' + width: '8' + height: '5' + fields: + - + type: INTEGER + name: source_type + value: '0' + - + type: GRAPH + name: graphid + value: + host: 'APC UPS Symmetra LX by SNMP' + name: 'Capacity of the UPS batteries' + - + type: GRAPH_CLASSIC + x: '8' + 'y': '10' + width: '8' + height: '5' + fields: + - + type: INTEGER + name: source_type + value: '0' + - + type: GRAPH + name: graphid + value: + host: 'APC UPS Symmetra LX by SNMP' + name: Voltage + - + type: GRAPH_CLASSIC + x: '16' + 'y': '10' + width: '8' + height: '5' + fields: + - + type: INTEGER + name: source_type + value: '0' + - + type: GRAPH + name: graphid + value: + host: 'APC UPS Symmetra LX by SNMP' + name: Output valuemaps: - uuid: aec3362485c242ec928cb8ecfe5e61cf @@ -1814,7 +1942,7 @@ zabbix_export: triggers: - uuid: 9d0c32f93c0c44f69b54c91fabfa1529 - expression: '(last(/APC UPS Symmetra LX SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/APC UPS Symmetra LX SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/APC UPS Symmetra LX SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/APC UPS Symmetra LX SNMP/system.net.uptime[sysUpTime.0])<10m)' + expression: '(last(/APC UPS Symmetra LX by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/APC UPS Symmetra LX by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/APC UPS Symmetra LX by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/APC UPS Symmetra LX by SNMP/system.net.uptime[sysUpTime.0])<10m)' name: 'Host has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING @@ -1823,7 +1951,7 @@ zabbix_export: dependencies: - name: 'No SNMP data collection' - expression: 'max(/APC UPS Symmetra LX SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' + expression: 'max(/APC UPS Symmetra LX by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' tags: - tag: scope @@ -1837,7 +1965,7 @@ zabbix_export: - color: 1A7C11 item: - host: 'APC UPS Symmetra LX SNMP' + host: 'APC UPS Symmetra LX by SNMP' key: 'battery.capacity[upsHighPrecBatteryCapacity]' - uuid: 2ef61780d42c4d61bcb89faf08691d08 @@ -1846,13 +1974,13 @@ zabbix_export: - color: 1A7C11 item: - host: 'APC UPS Symmetra LX SNMP' + host: 'APC UPS Symmetra LX by SNMP' key: 'output.current[upsHighPrecOutputCurrent]' - sortorder: '1' color: 2774A4 item: - host: 'APC UPS Symmetra LX SNMP' + host: 'APC UPS Symmetra LX by SNMP' key: 'output.load[upsHighPrecOutputLoad]' - uuid: 4432ed7ca97d4d989b253383037f48ee @@ -1861,11 +1989,11 @@ zabbix_export: - color: 1A7C11 item: - host: 'APC UPS Symmetra LX SNMP' + host: 'APC UPS Symmetra LX by SNMP' key: 'input.voltage[upsHighPrecInputLineVoltage]' - sortorder: '1' color: 2774A4 item: - host: 'APC UPS Symmetra LX SNMP' + host: 'APC UPS Symmetra LX by SNMP' key: 'output.voltage[upsHighPrecOutputVoltage]' |