Welcome to mirror list, hosted at ThFree Co, Russian Federation.

github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
Diffstat (limited to 'templates/server/dell/dell_r820_snmp/README.md')
-rw-r--r--templates/server/dell/dell_r820_snmp/README.md64
1 files changed, 32 insertions, 32 deletions
diff --git a/templates/server/dell/dell_r820_snmp/README.md b/templates/server/dell/dell_r820_snmp/README.md
index e8097fbde61..a0e52de1fa3 100644
--- a/templates/server/dell/dell_r820_snmp/README.md
+++ b/templates/server/dell/dell_r820_snmp/README.md
@@ -1,9 +1,9 @@
-# DELL PowerEdge R820 SNMP
+# DELL PowerEdge R820 by SNMP
## Overview
-For Zabbix version: 6.4 and higher
+For Zabbix version: 6.4 and higher.
This is a template for monitoring DELL PowerEdge R820 servers with iDRAC version 7 and later via Zabbix SNMP agent that works without any external scripts.
## Setup
@@ -113,38 +113,38 @@ There are no template links in this template.
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----|----|----|
-|Dell R820: {#CNTLR_NAME} is in unrecoverable state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL}` |DISASTER | |
-|Dell R820: {#CNTLR_NAME} is in critical state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}` |HIGH |<p>**Depends on**:</p><p>- Dell R820: {#CNTLR_NAME} is in unrecoverable state</p> |
-|Dell R820: {#CNTLR_NAME} is in warning state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN}` |AVERAGE |<p>**Depends on**:</p><p>- Dell R820: {#CNTLR_NAME} is in critical state</p><p>- Dell R820: {#CNTLR_NAME} is in unrecoverable state</p> |
-|Dell R820: {#BATTERY_NAME} is in critical state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}` |AVERAGE | |
-|Dell R820: {#BATTERY_NAME} is in warning state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: {#BATTERY_NAME} is in critical state</p> |
-|Dell R820: {#BATTERY_NAME} is not in optimal state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: {#BATTERY_NAME} is in critical state</p><p>- Dell R820: {#BATTERY_NAME} is in warning state</p> |
-|Dell R820: {#FAN_DESCR} is in critical state |<p>Please check the fan unit.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"failed"}` |AVERAGE | |
-|Dell R820: {#FAN_DESCR} is in warning state |<p>Please check the fan unit.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalLower"}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: {#FAN_DESCR} is in critical state</p> |
-|Dell R820: System name has changed |<p>System name has changed. Ack to close.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R820 SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R820 SNMP/dell.server.name[sysName]))>0` |INFO |<p>Manual close: YES</p> |
-|Dell R820: Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R820 SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R820 SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0` |INFO |<p>Manual close: YES</p> |
-|Dell R820: Operating system description has changed |<p>Operating system description has changed. Possibly, the system has been updated or replaced. Ack to close.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R820 SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R820 SNMP/dell.server.sw.os[systemOSName]))>0` |INFO |<p>Manual close: YES</p> |
-|Dell R820: Firmware has changed |<p>Firmware version has changed. Ack to close.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R820 SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R820 SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0` |INFO |<p>Manual close: YES</p> |
-|Dell R820: {#DISK_NAME} failed |<p>Please check physical disk for warnings or errors.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"}` |HIGH | |
-|Dell R820: {#DISK_NAME} is in warning state |<p>Please check physical disk for warnings or errors.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN:"nonCritical"}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: {#DISK_NAME} failed</p> |
-|Dell R820: {#DISK_NAME} S.M.A.R.T. failed |<p>Disk probably requires replacement.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}` |HIGH |<p>**Depends on**:</p><p>- Dell R820: {#DISK_NAME} failed</p> |
-|Dell R820: {#DISK_NAME} has been replaced |<p>{#DISK_NAME} serial number has changed. Ack to close</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R820 SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> |
-|Dell R820: Power supply {#PSU_DESCR} is in critical state |<p>Please check the power supply unit for errors.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"nonRecoverable"}` |AVERAGE | |
-|Dell R820: Power supply {#PSU_DESCR} is in warning state |<p>Please check the power supply unit for errors.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.WARN:"nonCritical"}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: Power supply {#PSU_DESCR} is in critical state</p> |
-|Dell R820: System is in unrecoverable state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.DISASTER}` |DISASTER | |
-|Dell R820: System status is in critical state |<p>Please check the device for errors.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.CRIT}` |HIGH | |
-|Dell R820: System status is in warning state |<p>Please check the device for warnings.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: System status is in critical state</p> |
-|Dell R820: Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/DELL PowerEdge R820 SNMP/dell.server.hw.uptime[hrSystemUptime])>0 and last(/DELL PowerEdge R820 SNMP/dell.server.hw.uptime[hrSystemUptime])<10m) or (last(/DELL PowerEdge R820 SNMP/dell.server.hw.uptime[hrSystemUptime])=0 and last(/DELL PowerEdge R820 SNMP/dell.server.net.uptime[sysUpTime])<10m)` |WARNING |<p>Manual close: YES</p> |
-|Dell R820: No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/DELL PowerEdge R820 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
-|Dell R820: Probe {#SENSOR_LOCALE} is in critical status |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}` |AVERAGE | |
-|Dell R820: Probe {#SENSOR_LOCALE} is in warning status |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: Probe {#SENSOR_LOCALE} is in critical status</p> |
-|Dell R820: Probe {#SENSOR_LOCALE} is not in optimal status |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$SENSOR.TEMP.STATUS.OK}` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Dell R820: Probe {#SENSOR_LOCALE} is in critical status</p><p>- Dell R820: Probe {#SENSOR_LOCALE} is in warning status</p> |
-|Dell R820: {#DISK_NAME} failed |<p>Please check the virtual disk for warnings or errors.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.CRIT:"failed"}` |HIGH | |
-|Dell R820: {#DISK_NAME} is in warning state |<p>Please check the virtual disk for warnings or errors.</p> |`last(/DELL PowerEdge R820 SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.WARN:"degraded"}` |AVERAGE |<p>**Depends on**:</p><p>- Dell R820: {#DISK_NAME} failed</p> |
+|Dell R820: {#CNTLR_NAME} is in unrecoverable state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL}` |DISASTER | |
+|Dell R820: {#CNTLR_NAME} is in critical state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}` |HIGH |<p>**Depends on**:</p><p>- Dell R820: {#CNTLR_NAME} is in unrecoverable state</p> |
+|Dell R820: {#CNTLR_NAME} is in warning state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN}` |AVERAGE |<p>**Depends on**:</p><p>- Dell R820: {#CNTLR_NAME} is in critical state</p><p>- Dell R820: {#CNTLR_NAME} is in unrecoverable state</p> |
+|Dell R820: {#BATTERY_NAME} is in critical state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}` |AVERAGE | |
+|Dell R820: {#BATTERY_NAME} is in warning state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: {#BATTERY_NAME} is in critical state</p> |
+|Dell R820: {#BATTERY_NAME} is not in optimal state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: {#BATTERY_NAME} is in critical state</p><p>- Dell R820: {#BATTERY_NAME} is in warning state</p> |
+|Dell R820: {#FAN_DESCR} is in critical state |<p>Please check the fan unit.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"failed"}` |AVERAGE | |
+|Dell R820: {#FAN_DESCR} is in warning state |<p>Please check the fan unit.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalLower"}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: {#FAN_DESCR} is in critical state</p> |
+|Dell R820: System name has changed |<p>System name has changed. Ack to close.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.name[sysName]))>0` |INFO |<p>Manual close: YES</p> |
+|Dell R820: Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0` |INFO |<p>Manual close: YES</p> |
+|Dell R820: Operating system description has changed |<p>Operating system description has changed. Possibly, the system has been updated or replaced. Ack to close.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.sw.os[systemOSName]))>0` |INFO |<p>Manual close: YES</p> |
+|Dell R820: Firmware has changed |<p>Firmware version has changed. Ack to close.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0` |INFO |<p>Manual close: YES</p> |
+|Dell R820: {#DISK_NAME} failed |<p>Please check physical disk for warnings or errors.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"}` |HIGH | |
+|Dell R820: {#DISK_NAME} is in warning state |<p>Please check physical disk for warnings or errors.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN:"nonCritical"}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: {#DISK_NAME} failed</p> |
+|Dell R820: {#DISK_NAME} S.M.A.R.T. failed |<p>Disk probably requires replacement.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}` |HIGH |<p>**Depends on**:</p><p>- Dell R820: {#DISK_NAME} failed</p> |
+|Dell R820: {#DISK_NAME} has been replaced |<p>{#DISK_NAME} serial number has changed. Ack to close</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> |
+|Dell R820: Power supply {#PSU_DESCR} is in critical state |<p>Please check the power supply unit for errors.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"nonRecoverable"}` |AVERAGE | |
+|Dell R820: Power supply {#PSU_DESCR} is in warning state |<p>Please check the power supply unit for errors.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.WARN:"nonCritical"}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: Power supply {#PSU_DESCR} is in critical state</p> |
+|Dell R820: System is in unrecoverable state |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.DISASTER}` |DISASTER | |
+|Dell R820: System status is in critical state |<p>Please check the device for errors.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.CRIT}` |HIGH | |
+|Dell R820: System status is in warning state |<p>Please check the device for warnings.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: System status is in critical state</p> |
+|Dell R820: Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.uptime[hrSystemUptime])>0 and last(/DELL PowerEdge R820 by SNMP/dell.server.hw.uptime[hrSystemUptime])<10m) or (last(/DELL PowerEdge R820 by SNMP/dell.server.hw.uptime[hrSystemUptime])=0 and last(/DELL PowerEdge R820 by SNMP/dell.server.net.uptime[sysUpTime])<10m)` |WARNING |<p>Manual close: YES</p> |
+|Dell R820: No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/DELL PowerEdge R820 by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
+|Dell R820: Probe {#SENSOR_LOCALE} is in critical status |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}` |AVERAGE | |
+|Dell R820: Probe {#SENSOR_LOCALE} is in warning status |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}` |WARNING |<p>**Depends on**:</p><p>- Dell R820: Probe {#SENSOR_LOCALE} is in critical status</p> |
+|Dell R820: Probe {#SENSOR_LOCALE} is not in optimal status |<p>Please check the device for faults.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$SENSOR.TEMP.STATUS.OK}` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Dell R820: Probe {#SENSOR_LOCALE} is in critical status</p><p>- Dell R820: Probe {#SENSOR_LOCALE} is in warning status</p> |
+|Dell R820: {#DISK_NAME} failed |<p>Please check the virtual disk for warnings or errors.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.CRIT:"failed"}` |HIGH | |
+|Dell R820: {#DISK_NAME} is in warning state |<p>Please check the virtual disk for warnings or errors.</p> |`last(/DELL PowerEdge R820 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.WARN:"degraded"}` |AVERAGE |<p>**Depends on**:</p><p>- Dell R820: {#DISK_NAME} failed</p> |
## Feedback
-Please report any issues with the template at https://support.zabbix.com
+Please report any issues with the template at https://support.zabbix.com.
-You can also provide feedback, discuss the template or ask for help with it at [ZABBIX forums](https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates).
+You can also provide feedback, discuss the template, or ask for help at [ZABBIX forums](https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates).