@@ -1,9 +1,9 @@
-# HPE ProLiant DL360 SNMP
+# HPE ProLiant DL360 by SNMP
## Overview
-For Zabbix version: 6.4 and higher
+For Zabbix version: 6.4 and higher.
This is a template for monitoring HPE ProLiant DL360 servers with HP iLO version 4 and later via Zabbix SNMP agent that works without any external scripts.
## Setup
@@ -122,54 +122,54 @@ There are no template links in this template.
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----|----|----|
-|{#CNTLR_LOCATION}: Disk array controller is in critical state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}` |HIGH | |
-|{#CNTLR_LOCATION}: Disk array controller is in warning state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN}` |AVERAGE |<p>**Depends on**:</p><p>- {#CNTLR_LOCATION}: Disk array controller is in critical state</p> |
-|#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state! |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}` |AVERAGE | |
-|#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in warning state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModDegradedFailsafeSpeed"} or last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheReadCacheNotMapped"} or last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModFlashMemNotAttached"}` |WARNING |<p>**Depends on**:</p><p>- #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!</p> |
-|#{#CACHE_CNTRL_INDEX}: Disk array cache controller is not in optimal state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.STATUS.OK:"enabled"} and last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.STATUS.WARN:"invalid"}` |WARNING |<p>**Depends on**:</p><p>- #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!</p><p>- #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in warning state</p> |
-|#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in critical state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"failed"} or last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"capacitorFailed"}` |AVERAGE | |
-|#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in warning state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"degraded"}` |WARNING |<p>**Depends on**:</p><p>- #{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in critical state</p> |
-|Fan {#SNMPINDEX}: Fan is in critical state |<p>Please check the fan unit.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}])={$FAN.STATUS.CRIT}` |AVERAGE | |
-|Fan {#SNMPINDEX}: Fan is in warning state |<p>Please check the fan unit.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}])={$FAN.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- Fan {#SNMPINDEX}: Fan is in critical state</p> |
-|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.name[sysName],#1)<>last(/HPE ProLiant DL360 SNMP/hp.server.name[sysName],#2) and length(last(/HPE ProLiant DL360 SNMP/hp.server.name[sysName]))>0` |INFO |<p>Manual close: YES</p> |
-|Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum],#1)<>last(/HPE ProLiant DL360 SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum],#2) and length(last(/HPE ProLiant DL360 SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum]))>0` |INFO |<p>Manual close: YES</p> |
-|{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has failed |<p>Please check the physical adapter.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}])=3` |HIGH | |
-|{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has lost link |<p>Please check the cable connections to this adapter.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}])=4` |AVERAGE |<p>**Depends on**:</p><p>- {#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has failed</p> |
-|{#DISK_LOCATION}: Physical disk failed |<p>Please check physical disk for warnings or errors.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL}` |HIGH | |
-|{#DISK_LOCATION}: Physical disk is in warning state |<p>Please check physical disk for warnings or errors.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- {#DISK_LOCATION}: Physical disk failed</p> |
-|{#DISK_LOCATION}: Physical disk S.M.A.R.T. failed |<p>Disk probably requires replacement.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/HPE ProLiant DL360 SNMP/hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}` |HIGH |<p>**Depends on**:</p><p>- {#DISK_LOCATION}: Physical disk failed</p> |
-|{#DISK_LOCATION}: Disk has been replaced |<p>Disk serial number has changed. Ack to close</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}],#1)<>last(/HPE ProLiant DL360 SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}],#2) and length(last(/HPE ProLiant DL360 SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> |
-|Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in critical state |<p>Please check the power supply unit for errors.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}])={$PSU.STATUS.CRIT}` |AVERAGE | |
-|Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in warning state |<p>Please check the power supply unit for errors.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}])={$PSU.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in critical state</p> |
-|System status is in critical state |<p>Please check the device for errors.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.status[cpqHeMibCondition])={$HEALTH.STATUS.CRIT}` |HIGH | |
-|System status is in warning state |<p>Please check the device for warnings.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.status[cpqHeMibCondition])={$HEALTH.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- System status is in critical state</p> |
-|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/HPE ProLiant DL360 SNMP/hp.server.hw.uptime[hrSystemUptime])>0 and last(/HPE ProLiant DL360 SNMP/hp.server.hw.uptime[hrSystemUptime])<10m) or (last(/HPE ProLiant DL360 SNMP/hp.server.hw.uptime[hrSystemUptime])=0 and last(/HPE ProLiant DL360 SNMP/hp.server.net.uptime[sysUpTime])<10m)` |WARNING |<p>Manual close: YES</p> |
-|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/HPE ProLiant DL360 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
-|{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
-|{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 3` |WARNING | |
-|{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 4` |HIGH | |
-|Ambient: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
-|Ambient: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 3` |WARNING | |
-|Ambient: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 4` |HIGH | |
-|CPU-{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
-|CPU-{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 3` |WARNING | |
-|CPU-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 4` |HIGH | |
-|Memory-{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
-|Memory-{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 3` |WARNING | |
-|Memory-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 4` |HIGH | |
-|PSU-{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
-|PSU-{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 3` |WARNING | |
-|PSU-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 4` |HIGH | |
-|I/O-{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 1` |INFO |<p>Manual close: YES</p> |
-|I/O-{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 3` |WARNING | |
-|I/O-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 4` |HIGH | |
-|System-{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
-|System-{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 3` |WARNING | |
-|System-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 4` |HIGH | |
-|Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk failed |<p>Please check virtual disk for warnings or errors.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}])={$VDISK.STATUS.CRIT}` |HIGH | |
-|Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk is not in OK state |<p>Please check virtual disk for warnings or errors.</p> |`last(/HPE ProLiant DL360 SNMP/hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}])<>{$VDISK.STATUS.OK}` |WARNING |<p>**Depends on**:</p><p>- Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk failed</p> |
+|{#CNTLR_LOCATION}: Disk array controller is in critical state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}` |HIGH | |
+|{#CNTLR_LOCATION}: Disk array controller is in warning state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN}` |AVERAGE |<p>**Depends on**:</p><p>- {#CNTLR_LOCATION}: Disk array controller is in critical state</p> |
+|#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state! |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}` |AVERAGE | |
+|#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in warning state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModDegradedFailsafeSpeed"} or last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheReadCacheNotMapped"} or last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModFlashMemNotAttached"}` |WARNING |<p>**Depends on**:</p><p>- #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!</p> |
+|#{#CACHE_CNTRL_INDEX}: Disk array cache controller is not in optimal state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.STATUS.OK:"enabled"} and last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.STATUS.WARN:"invalid"}` |WARNING |<p>**Depends on**:</p><p>- #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!</p><p>- #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in warning state</p> |
+|#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in critical state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"failed"} or last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"capacitorFailed"}` |AVERAGE | |
+|#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in warning state |<p>Please check the device for faults.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"degraded"}` |WARNING |<p>**Depends on**:</p><p>- #{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in critical state</p> |
+|Fan {#SNMPINDEX}: Fan is in critical state |<p>Please check the fan unit.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}])={$FAN.STATUS.CRIT}` |AVERAGE | |
+|Fan {#SNMPINDEX}: Fan is in warning state |<p>Please check the fan unit.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}])={$FAN.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- Fan {#SNMPINDEX}: Fan is in critical state</p> |
+|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.name[sysName],#1)<>last(/HPE ProLiant DL360 by SNMP/hp.server.name[sysName],#2) and length(last(/HPE ProLiant DL360 by SNMP/hp.server.name[sysName]))>0` |INFO |<p>Manual close: YES</p> |
+|Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum],#1)<>last(/HPE ProLiant DL360 by SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum],#2) and length(last(/HPE ProLiant DL360 by SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum]))>0` |INFO |<p>Manual close: YES</p> |
+|{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has failed |<p>Please check the physical adapter.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}])=3` |HIGH | |
+|{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has lost link |<p>Please check the cable connections to this adapter.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}])=4` |AVERAGE |<p>**Depends on**:</p><p>- {#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has failed</p> |
+|{#DISK_LOCATION}: Physical disk failed |<p>Please check physical disk for warnings or errors.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL}` |HIGH | |
+|{#DISK_LOCATION}: Physical disk is in warning state |<p>Please check physical disk for warnings or errors.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- {#DISK_LOCATION}: Physical disk failed</p> |
+|{#DISK_LOCATION}: Physical disk S.M.A.R.T. failed |<p>Disk probably requires replacement.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/HPE ProLiant DL360 by SNMP/hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}` |HIGH |<p>**Depends on**:</p><p>- {#DISK_LOCATION}: Physical disk failed</p> |
+|{#DISK_LOCATION}: Disk has been replaced |<p>Disk serial number has changed. Ack to close</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}],#1)<>last(/HPE ProLiant DL360 by SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}],#2) and length(last(/HPE ProLiant DL360 by SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> |
+|Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in critical state |<p>Please check the power supply unit for errors.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}])={$PSU.STATUS.CRIT}` |AVERAGE | |
+|Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in warning state |<p>Please check the power supply unit for errors.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}])={$PSU.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in critical state</p> |
+|System status is in critical state |<p>Please check the device for errors.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.status[cpqHeMibCondition])={$HEALTH.STATUS.CRIT}` |HIGH | |
+|System status is in warning state |<p>Please check the device for warnings.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.status[cpqHeMibCondition])={$HEALTH.STATUS.WARN}` |WARNING |<p>**Depends on**:</p><p>- System status is in critical state</p> |
+|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/HPE ProLiant DL360 by SNMP/hp.server.hw.uptime[hrSystemUptime])>0 and last(/HPE ProLiant DL360 by SNMP/hp.server.hw.uptime[hrSystemUptime])<10m) or (last(/HPE ProLiant DL360 by SNMP/hp.server.hw.uptime[hrSystemUptime])=0 and last(/HPE ProLiant DL360 by SNMP/hp.server.net.uptime[sysUpTime])<10m)` |WARNING |<p>Manual close: YES</p> |
+|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/HPE ProLiant DL360 by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING | |
+|{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
+|{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 3` |WARNING | |
+|{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 4` |HIGH | |
+|Ambient: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
+|Ambient: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 3` |WARNING | |
+|Ambient: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 4` |HIGH | |
+|CPU-{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
+|CPU-{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 3` |WARNING | |
+|CPU-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 4` |HIGH | |
+|Memory-{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
+|Memory-{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 3` |WARNING | |
+|Memory-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 4` |HIGH | |
+|PSU-{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
+|PSU-{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 3` |WARNING | |
+|PSU-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 4` |HIGH | |
+|I/O-{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 1` |INFO |<p>Manual close: YES</p> |
+|I/O-{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 3` |WARNING | |
+|I/O-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 4` |HIGH | |
+|System-{#SNMPINDEX}: Temperature could not be determined |<p>Temperature could not be determined.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 1` |INFO |<p>Manual close: YES</p> |
+|System-{#SNMPINDEX}: The temperature sensor is outside of normal operating range |<p>If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 3` |WARNING | |
+|System-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system. |<p>The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 4` |HIGH | |
+|Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk failed |<p>Please check virtual disk for warnings or errors.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}])={$VDISK.STATUS.CRIT}` |HIGH | |
+|Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk is not in OK state |<p>Please check virtual disk for warnings or errors.</p> |`last(/HPE ProLiant DL360 by SNMP/hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}])<>{$VDISK.STATUS.OK}` |WARNING |<p>**Depends on**:</p><p>- Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk failed</p> |
## Feedback
-Please report any issues with the template at https://support.zabbix.com
+Please report any issues with the template at https://support.zabbix.com.