Welcome to mirror list, hosted at ThFree Co, Russian Federation.

README.md « dell_force_s_series_snmp « net « templates - github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
blob: 0585835a2ff2e7f81a7a9563cd87fa256e0adb2c (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129

# Dell Force S-Series SNMP

## Overview

For Zabbix version: 6.4 and higher  

## Setup

Refer to the vendor documentation.

## Zabbix configuration

No specific Zabbix configuration is required.

### Macros used

|Name|Description|Default|
|----|-----------|-------|
|{$CPU.UTIL.CRIT} |<p>-</p> |`90` |
|{$FAN_CRIT_STATUS} |<p>-</p> |`2` |
|{$FAN_OK_STATUS} |<p>-</p> |`1` |
|{$ICMP_LOSS_WARN} |<p>-</p> |`20` |
|{$ICMP_RESPONSE_TIME_WARN} |<p>-</p> |`0.15` |
|{$IF.ERRORS.WARN} |<p>-</p> |`2` |
|{$IF.UTIL.MAX} |<p>-</p> |`90` |
|{$IFCONTROL} |<p>-</p> |`1` |
|{$MEMORY.UTIL.MAX} |<p>-</p> |`90` |
|{$NET.IF.IFADMINSTATUS.MATCHES} |<p>Ignore notPresent(6)</p> |`^.*` |
|{$NET.IF.IFADMINSTATUS.NOT_MATCHES} |<p>Ignore down(2) administrative status</p> |`^2$` |
|{$NET.IF.IFALIAS.MATCHES} |<p>-</p> |`.*` |
|{$NET.IF.IFALIAS.NOT_MATCHES} |<p>-</p> |`CHANGE_IF_NEEDED` |
|{$NET.IF.IFDESCR.MATCHES} |<p>-</p> |`.*` |
|{$NET.IF.IFDESCR.NOT_MATCHES} |<p>-</p> |`CHANGE_IF_NEEDED` |
|{$NET.IF.IFNAME.MATCHES} |<p>-</p> |`^.*$` |
|{$NET.IF.IFNAME.NOT_MATCHES} |<p>Filter out loopbacks, nulls, docker veth links and docker0 bridge by default</p> |`(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12})` |
|{$NET.IF.IFOPERSTATUS.MATCHES} |<p>-</p> |`^.*$` |
|{$NET.IF.IFOPERSTATUS.NOT_MATCHES} |<p>Ignore notPresent(6)</p> |`^6$` |
|{$NET.IF.IFTYPE.MATCHES} |<p>-</p> |`.*` |
|{$NET.IF.IFTYPE.NOT_MATCHES} |<p>-</p> |`CHANGE_IF_NEEDED` |
|{$PSU_CRIT_STATUS} |<p>-</p> |`2` |
|{$PSU_OK_STATUS} |<p>-</p> |`1` |
|{$SNMP.TIMEOUT} |<p>-</p> |`5m` |
|{$TEMP_CRIT_LOW} |<p>-</p> |`5` |
|{$TEMP_CRIT} |<p>-</p> |`65` |
|{$TEMP_WARN} |<p>-</p> |`55` |

## Template links

There are no template links in this template.

## Discovery rules

|Name|Description|Type|Key and additional info|
|----|-----------|----|----|
|CPU and Memory and Flash Discovery |<p>-</p> |SNMP |module.discovery |
|EtherLike-MIB Discovery |<p>Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered.</p> |SNMP |net.if.duplex.discovery<p>**Preprocessing**:</p><p>- JAVASCRIPT: `The text is too long. Please see the template.`</p><p>**Filter**:</p>AND <p>- {#IFOPERSTATUS} MATCHES_REGEX `1`</p><p>- {#SNMPVALUE} MATCHES_REGEX `(2|3)`</p> |
|FAN Discovery |<p>-</p> |SNMP |fan.discovery |
|Network interfaces discovery |<p>Discovering interfaces from IF-MIB.</p> |SNMP |net.if.discovery<p>**Filter**:</p>AND <p>- {#IFADMINSTATUS} MATCHES_REGEX `{$NET.IF.IFADMINSTATUS.MATCHES}`</p><p>- {#IFADMINSTATUS} NOT_MATCHES_REGEX `{$NET.IF.IFADMINSTATUS.NOT_MATCHES}`</p><p>- {#IFOPERSTATUS} MATCHES_REGEX `{$NET.IF.IFOPERSTATUS.MATCHES}`</p><p>- {#IFOPERSTATUS} NOT_MATCHES_REGEX `{$NET.IF.IFOPERSTATUS.NOT_MATCHES}`</p><p>- {#IFNAME} MATCHES_REGEX `{$NET.IF.IFNAME.MATCHES}`</p><p>- {#IFNAME} NOT_MATCHES_REGEX `{$NET.IF.IFNAME.NOT_MATCHES}`</p><p>- {#IFDESCR} MATCHES_REGEX `{$NET.IF.IFDESCR.MATCHES}`</p><p>- {#IFDESCR} NOT_MATCHES_REGEX `{$NET.IF.IFDESCR.NOT_MATCHES}`</p><p>- {#IFALIAS} MATCHES_REGEX `{$NET.IF.IFALIAS.MATCHES}`</p><p>- {#IFALIAS} NOT_MATCHES_REGEX `{$NET.IF.IFALIAS.NOT_MATCHES}`</p><p>- {#IFTYPE} MATCHES_REGEX `{$NET.IF.IFTYPE.MATCHES}`</p><p>- {#IFTYPE} NOT_MATCHES_REGEX `{$NET.IF.IFTYPE.NOT_MATCHES}`</p> |
|PSU Discovery |<p>A list of power supply residents in the S-series chassis.</p> |SNMP |psu.discovery |
|Stack Unit Discovery |<p>-</p> |SNMP |stack.discovery |

## Items collected

|Group|Name|Description|Type|Key and additional info|
|-----|----|-----------|----|---------------------|
|CPU |#{#SNMPINDEX}: CPU utilization |<p>MIB: F10-S-SERIES-CHASSIS-MIB</p><p>CPU utilization in percentage for last 1 minute.</p> |SNMP |system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}] |
|Fans |Fan {#SNMPVALUE}: Fan status |<p>MIB: F10-S-SERIES-CHASSIS-MIB</p><p>The status of the fan tray {#SNMPVALUE}.</p> |SNMP |sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}] |
|General |SNMP traps (fallback) |<p>The item is used to collect all SNMP traps unmatched by other snmptrap items</p> |SNMP_TRAP |snmptrap.fallback |
|General |System location |<p>MIB: SNMPv2-MIB</p><p>The physical location of this node (e.g., `telephone closet, 3rd floor').  If the location is unknown, the value is the zero-length string.</p> |SNMP |system.location[sysLocation.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
|General |System contact details |<p>MIB: SNMPv2-MIB</p><p>The textual identification of the contact person for this managed node, together with information on how to contact this person.  If no contact information is known, the value is the zero-length string.</p> |SNMP |system.contact[sysContact.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
|General |System object ID |<p>MIB: SNMPv2-MIB</p><p>The vendor's authoritative identification of the network management subsystem contained in the entity.  This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed.  For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.</p> |SNMP |system.objectid[sysObjectID.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
|General |System name |<p>MIB: SNMPv2-MIB</p><p>An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name.  If the name is unknown, the value is the zero-length string.</p> |SNMP |system.name<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
|General |System description |<p>MIB: SNMPv2-MIB</p><p>A textual description of the entity. This value should</p><p>include the full name and version identification of the system's hardware type, software operating-system, and</p><p>networking software.</p> |SNMP |system.descr[sysDescr.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `12h`</p> |
|Inventory |#{#SNMPVALUE}: Hardware model name |<p>MIB: F10-S-SERIES-CHASSIS-MIB</p><p>The plugged-in model ID for this unit.</p> |SNMP |system.hw.model[chStackUnitModelID.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> |
|Inventory |#{#SNMPVALUE}: Hardware serial number |<p>MIB: F10-S-SERIES-CHASSIS-MIB</p><p>The unit's serial number.</p> |SNMP |system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> |
|Inventory |#{#SNMPVALUE}: Hardware version(revision) |<p>MIB: F10-S-SERIES-CHASSIS-MIB</p><p>The unit manufacturer's product revision</p> |SNMP |system.hw.version[chStackUnitProductRev.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> |
|Inventory |#{#SNMPVALUE}: Operating system |<p>MIB: F10-S-SERIES-CHASSIS-MIB</p><p>Current code version of this unit.</p> |SNMP |system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> |
|Memory |#{#SNMPINDEX}: Memory utilization |<p>MIB: F10-S-SERIES-CHASSIS-MIB</p><p>Total memory usage in percentage.</p> |SNMP |vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}] |
|Network interfaces |Interface {#IFNAME}({#IFALIAS}): Duplex status |<p>MIB: EtherLike-MIB</p><p>The current mode of operation of the MAC</p><p>entity.  'unknown' indicates that the current</p><p>duplex mode could not be determined.</p><p>Management control of the duplex mode is</p><p>accomplished through the MAU MIB.  When</p><p>an interface does not support autonegotiation,</p><p>or when autonegotiation is not enabled, the</p><p>duplex mode is controlled using</p><p>ifMauDefaultType.  When autonegotiation is</p><p>supported and enabled, duplex mode is controlled</p><p>using ifMauAutoNegAdvertisedBits.  In either</p><p>case, the currently operating duplex mode is</p><p>reflected both in this object and in ifMauType.</p><p>Note that this object provides redundant</p><p>information with ifMauType.  Normally, redundant</p><p>objects are discouraged.  However, in this</p><p>instance, it allows a management application to</p><p>determine the duplex status of an interface</p><p>without having to know every possible value of</p><p>ifMauType.  This was felt to be sufficiently</p><p>valuable to justify the redundancy.</p><p>Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus.</p> |SNMP |net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}] |
|Network interfaces |Interface {#IFNAME}({#IFALIAS}): Operational status |<p>MIB: IF-MIB</p><p>The current operational state of the interface.</p><p>- The testing(3) state indicates that no operational packet scan be passed</p><p>- If ifAdminStatus is down(2) then ifOperStatus should be down(2)</p><p>- If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic</p><p>- It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection)</p><p>- It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state</p><p>- It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.</p> |SNMP |net.if.status[ifOperStatus.{#SNMPINDEX}] |
|Network interfaces |Interface {#IFNAME}({#IFALIAS}): Bits received |<p>MIB: IF-MIB</p><p>The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.</p> |SNMP |net.if.in[ifHCInOctets.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- CHANGE_PER_SECOND</p><p>- MULTIPLIER: `8`</p> |
|Network interfaces |Interface {#IFNAME}({#IFALIAS}): Bits sent |<p>MIB: IF-MIB</p><p>The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.</p> |SNMP |net.if.out[ifHCOutOctets.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- CHANGE_PER_SECOND</p><p>- MULTIPLIER: `8`</p> |
|Network interfaces |Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors |<p>MIB: IF-MIB</p><p>For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.  For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.</p> |SNMP |net.if.in.errors[ifInErrors.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- CHANGE_PER_SECOND</p> |
|Network interfaces |Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors |<p>MIB: IF-MIB</p><p>For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.  For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.</p> |SNMP |net.if.out.errors[ifOutErrors.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- CHANGE_PER_SECOND</p> |
|Network interfaces |Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded |<p>MIB: IF-MIB</p><p>The number of outbound packets which were chosen to be discarded</p><p>even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.</p><p>One possible reason for discarding such a packet could be to free up buffer space.</p><p>Discontinuities in the value of this counter can occur at re-initialization of the management system,</p><p>and at other times as indicated by the value of ifCounterDiscontinuityTime.</p> |SNMP |net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- CHANGE_PER_SECOND</p> |
|Network interfaces |Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded |<p>MIB: IF-MIB</p><p>The number of inbound packets which were chosen to be discarded</p><p>even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.</p><p>One possible reason for discarding such a packet could be to free up buffer space.</p><p>Discontinuities in the value of this counter can occur at re-initialization of the management system,</p><p>and at other times as indicated by the value of ifCounterDiscontinuityTime.</p> |SNMP |net.if.in.discards[ifInDiscards.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- CHANGE_PER_SECOND</p> |
|Network interfaces |Interface {#IFNAME}({#IFALIAS}): Interface type |<p>MIB: IF-MIB</p><p>The type of interface.</p><p>Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA),</p><p>through updating the syntax of the IANAifType textual convention.</p> |SNMP |net.if.type[ifType.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1d`</p> |
|Network interfaces |Interface {#IFNAME}({#IFALIAS}): Speed |<p>MIB: IF-MIB</p><p>An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'.  For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero.</p> |SNMP |net.if.speed[ifHighSpeed.{#SNMPINDEX}]<p>**Preprocessing**:</p><p>- MULTIPLIER: `1000000`</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1h`</p> |
|Power supply |PSU {#SNMPVALUE}: Power supply status |<p>MIB: F10-S-SERIES-CHASSIS-MIB</p><p>The status of the power supply {#SNMPVALUE}</p> |SNMP |sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}] |
|Status |Uptime (network) |<p>MIB: SNMPv2-MIB</p><p>The time (in hundredths of a second) since the network management portion of the system was last re-initialized.</p> |SNMP |system.net.uptime[sysUpTime.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.01`</p> |
|Status |Uptime (hardware) |<p>MIB: HOST-RESOURCES-MIB</p><p>The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.</p> |SNMP |system.hw.uptime[hrSystemUptime.0]<p>**Preprocessing**:</p><p>- CHECK_NOT_SUPPORTED</p><p>⛔️ON_FAIL: `CUSTOM_VALUE -> 0`</p><p>- MULTIPLIER: `0.01`</p> |
|Status |SNMP agent availability |<p>Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.</p><p>Possible value:</p><p>0 - not available</p><p>1 - available</p><p>2 - unknown</p> |INTERNAL |zabbix[host,snmp,available] |
|Status |ICMP ping |<p>-</p> |SIMPLE |icmpping |
|Status |ICMP loss |<p>-</p> |SIMPLE |icmppingloss |
|Status |ICMP response time |<p>-</p> |SIMPLE |icmppingsec |
|Temperature |Device {#SNMPVALUE}: Temperature |<p>MIB: F10-S-SERIES-CHASSIS-MIB</p><p>The temperature of the unit.</p> |SNMP |sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}] |

## Triggers

|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----|----|----|
|#{#SNMPINDEX}: High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/Dell Force S-Series SNMP/system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}` |WARNING | |
|Fan {#SNMPVALUE}: Fan is in critical state |<p>Please check the fan unit</p> |`count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1` |AVERAGE | |
|Fan {#SNMPVALUE}: Fan is not in normal state |<p>Please check the fan unit</p> |`count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1` |INFO |<p>**Depends on**:</p><p>- Fan {#SNMPVALUE}: Fan is in critical state</p> |
|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/Dell Force S-Series SNMP/system.name,#1)<>last(/Dell Force S-Series SNMP/system.name,#2) and length(last(/Dell Force S-Series SNMP/system.name))>0` |INFO |<p>Manual close: YES</p> |
|#{#SNMPVALUE}: Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> |
|#{#SNMPVALUE}: Operating system description has changed |<p>Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.</p> |`last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- System name has changed</p> |
|#{#SNMPINDEX}: High memory utilization |<p>The system is running out of free memory.</p> |`min(/Dell Force S-Series SNMP/vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | |
|Interface {#IFNAME}({#IFALIAS}): In half-duplex mode |<p>Please check autonegotiation settings and cabling</p> |`last(/Dell Force S-Series SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2` |WARNING |<p>Manual close: YES</p> |
|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p><p>3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))`<p>Recovery expression:</p>`last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0` |AVERAGE |<p>Manual close: YES</p> |
|Interface {#IFNAME}({#IFALIAS}): High bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/Dell Force S-Series SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Dell Force S-Series SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0`<p>Recovery expression:</p>`avg(/Dell Force S-Series SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/Dell Force S-Series SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
|Interface {#IFNAME}({#IFALIAS}): High error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/Dell Force S-Series SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Dell Force S-Series SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/Dell Force S-Series SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/Dell Force S-Series SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`<p>Recovery expression:</p>`(change(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> |
|PSU {#SNMPVALUE}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1` |AVERAGE | |
|PSU {#SNMPVALUE}: Power supply is not in normal state |<p>Please check the power supply unit for errors</p> |`count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1` |INFO |<p>**Depends on**:</p><p>- PSU {#SNMPVALUE}: Power supply is in critical state</p> |
|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Dell Force S-Series SNMP/system.net.uptime[sysUpTime.0])<10m)` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> |
|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/Dell Force S-Series SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
|Unavailable by ICMP ping |<p>Last three attempts returned timeout.  Please check device connectivity.</p> |`max(/Dell Force S-Series SNMP/icmpping,#3)=0` |HIGH | |
|High ICMP ping loss |<p>-</p> |`min(/Dell Force S-Series SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> |
|High ICMP ping response time |<p>-</p> |`avg(/Dell Force S-Series SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> |
|Device {#SNMPVALUE}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3` |WARNING |<p>**Depends on**:</p><p>- Device {#SNMPVALUE}: Temperature is above critical threshold</p> |
|Device {#SNMPVALUE}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3` |HIGH | |
|Device {#SNMPVALUE}: Temperature is too low |<p>-</p> |`avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`min(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3` |AVERAGE | |