Welcome to mirror list, hosted at ThFree Co, Russian Federation.

template_net_dell_force_s_series_snmp.yaml « dell_force_s_series_snmp « net « templates - github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
blob: ab1c676c3e45e02d2fc4419eacf9899298532971 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
zabbix_export:
  version: '6.4'
  date: '2022-08-16T11:05:05Z'
  template_groups:
    -
      uuid: 36bff6c29af64692839d077febfc7079
      name: 'Templates/Network devices'
  templates:
    -
      uuid: e5ec7acc7efc4ac491b6fa552ab077ae
      template: 'Dell Force S-Series SNMP'
      name: 'Dell Force S-Series SNMP'
      description: |
        Template Dell Force S-Series
        
        MIBs used:
        F10-S-SERIES-CHASSIS-MIB
        EtherLike-MIB
        HOST-RESOURCES-MIB
        SNMPv2-MIB
        IF-MIB
        
        Template tooling version used: 0.42
      groups:
        -
          name: 'Templates/Network devices'
      items:
        -
          uuid: 3853e6ef8cbf4e59a64422659f66bbb7
          name: 'ICMP ping'
          type: SIMPLE
          key: icmpping
          history: 1w
          valuemap:
            name: 'Service state'
          tags:
            -
              tag: component
              value: health
            -
              tag: component
              value: network
          triggers:
            -
              uuid: f186488b337f4b1b8971992e8118d9cc
              expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0'
              name: 'Unavailable by ICMP ping'
              priority: HIGH
              description: 'Last three attempts returned timeout.  Please check device connectivity.'
              tags:
                -
                  tag: scope
                  value: availability
        -
          uuid: ef0432ffcf0546bf82177193866861cf
          name: 'ICMP loss'
          type: SIMPLE
          key: icmppingloss
          history: 1w
          value_type: FLOAT
          units: '%'
          tags:
            -
              tag: component
              value: health
            -
              tag: component
              value: network
          triggers:
            -
              uuid: 46798adec54c47a38cb599773767a2a7
              expression: 'min(/Dell Force S-Series SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series SNMP/icmppingloss,5m)<100'
              name: 'High ICMP ping loss'
              opdata: 'Loss: {ITEM.LASTVALUE1}'
              priority: WARNING
              dependencies:
                -
                  name: 'Unavailable by ICMP ping'
                  expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0'
              tags:
                -
                  tag: scope
                  value: availability
                -
                  tag: scope
                  value: performance
        -
          uuid: 9b56a2a725bf4632bc28c6a5d0c3d64b
          name: 'ICMP response time'
          type: SIMPLE
          key: icmppingsec
          history: 1w
          value_type: FLOAT
          units: s
          tags:
            -
              tag: component
              value: health
            -
              tag: component
              value: network
          triggers:
            -
              uuid: 04828676081147b4bfad0ad03385986e
              expression: 'avg(/Dell Force S-Series SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
              name: 'High ICMP ping response time'
              opdata: 'Value: {ITEM.LASTVALUE1}'
              priority: WARNING
              dependencies:
                -
                  name: 'High ICMP ping loss'
                  expression: 'min(/Dell Force S-Series SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series SNMP/icmppingloss,5m)<100'
                -
                  name: 'Unavailable by ICMP ping'
                  expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0'
              tags:
                -
                  tag: scope
                  value: availability
                -
                  tag: scope
                  value: performance
        -
          uuid: ba8178338b0e41ac97b0265f98b90770
          name: 'SNMP traps (fallback)'
          type: SNMP_TRAP
          key: snmptrap.fallback
          history: 2w
          trends: '0'
          value_type: LOG
          description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items'
          logtimefmt: 'hh:mm:sszyyyy/MM/dd'
          tags:
            -
              tag: component
              value: network
        -
          uuid: d4df70f2c5f04ad2b7f1b4e8ab9a9993
          name: 'System contact details'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.4.0
          key: 'system.contact[sysContact.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The textual identification of the contact person for this managed node, together with information on how to contact this person.  If no contact information is known, the value is the zero-length string.
          inventory_link: CONTACT
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 12h
          tags:
            -
              tag: component
              value: system
        -
          uuid: 804476e771374e22b8767f90f271654a
          name: 'System description'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.1.0
          key: 'system.descr[sysDescr.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            A textual description of the entity. This value should
            include the full name and version identification of the system's hardware type, software operating-system, and
            networking software.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 12h
          tags:
            -
              tag: component
              value: system
        -
          uuid: 5297253edb09463e8fdb6f1905e4f494
          name: 'Uptime (hardware)'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.25.1.1.0
          key: 'system.hw.uptime[hrSystemUptime.0]'
          delay: 30s
          history: 2w
          trends: 0d
          units: uptime
          description: |
            MIB: HOST-RESOURCES-MIB
            The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.
          preprocessing:
            -
              type: CHECK_NOT_SUPPORTED
              parameters:
                - ''
              error_handler: CUSTOM_VALUE
              error_handler_params: '0'
            -
              type: MULTIPLIER
              parameters:
                - '0.01'
          tags:
            -
              tag: component
              value: system
        -
          uuid: f3d1970fc4404b4fa50a855433681105
          name: 'System location'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.6.0
          key: 'system.location[sysLocation.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The physical location of this node (e.g., `telephone closet, 3rd floor').  If the location is unknown, the value is the zero-length string.
          inventory_link: LOCATION
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 12h
          tags:
            -
              tag: component
              value: system
        -
          uuid: a36cccdaf24c4e82801ebb44eaa5e25a
          name: 'System name'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.5.0
          key: system.name
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name.  If the name is unknown, the value is the zero-length string.
          inventory_link: NAME
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 12h
          tags:
            -
              tag: component
              value: system
          triggers:
            -
              uuid: 2dc35c5813b042fd96f2ebc53f565799
              expression: 'last(/Dell Force S-Series SNMP/system.name,#1)<>last(/Dell Force S-Series SNMP/system.name,#2) and length(last(/Dell Force S-Series SNMP/system.name))>0'
              name: 'System name has changed'
              event_name: 'System name has changed (new name: {ITEM.VALUE})'
              priority: INFO
              description: 'System name has changed. Ack to close.'
              manual_close: 'YES'
              tags:
                -
                  tag: scope
                  value: notice
                -
                  tag: scope
                  value: security
        -
          uuid: 26a0a117545f4b17986f0b48996fec47
          name: 'Uptime (network)'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.3.0
          key: 'system.net.uptime[sysUpTime.0]'
          delay: 30s
          history: 2w
          trends: 0d
          units: uptime
          description: |
            MIB: SNMPv2-MIB
            The time (in hundredths of a second) since the network management portion of the system was last re-initialized.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.01'
          tags:
            -
              tag: component
              value: system
        -
          uuid: 651059497914431f827ad82a982e139b
          name: 'System object ID'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.2.0
          key: 'system.objectid[sysObjectID.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The vendor's authoritative identification of the network management subsystem contained in the entity.  This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed.  For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 12h
          tags:
            -
              tag: component
              value: system
        -
          uuid: 7ce4f98cdc6741bbb03f6e2ea03432c4
          name: 'SNMP agent availability'
          type: INTERNAL
          key: 'zabbix[host,snmp,available]'
          history: 7d
          description: |
            Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
            Possible value:
            0 - not available
            1 - available
            2 - unknown
          valuemap:
            name: zabbix.host.available
          tags:
            -
              tag: component
              value: health
            -
              tag: component
              value: network
          triggers:
            -
              uuid: da99689aa1394d17af5008e5678915bc
              expression: 'max(/Dell Force S-Series SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
              name: 'No SNMP data collection'
              opdata: 'Current state: {ITEM.LASTVALUE1}'
              priority: WARNING
              description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
              dependencies:
                -
                  name: 'Unavailable by ICMP ping'
                  expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0'
              tags:
                -
                  tag: scope
                  value: availability
      discovery_rules:
        -
          uuid: f35cb754ebd748b7842c67461264f48d
          name: 'FAN Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.6027.3.10.1.2.4.1.1]'
          key: fan.discovery
          delay: 1h
          item_prototypes:
            -
              uuid: c916b4658e914e93af13b4fe7b58138e
              name: 'Fan {#SNMPVALUE}: Fan status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.6027.3.10.1.2.4.1.2.{#SNMPINDEX}'
              key: 'sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}]'
              delay: 3m
              history: 2w
              trends: 0d
              description: |
                MIB: F10-S-SERIES-CHASSIS-MIB
                The status of the fan tray {#SNMPVALUE}.
              valuemap:
                name: 'F10-S-SERIES-CHASSIS-MIB::chSysFanTrayOperStatus'
              tags:
                -
                  tag: component
                  value: fan
              trigger_prototypes:
                -
                  uuid: aecc6fdd58404347b3074b0c1db63f09
                  expression: 'count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
                  name: 'Fan {#SNMPVALUE}: Fan is in critical state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
                  description: 'Please check the fan unit'
                  tags:
                    -
                      tag: scope
                      value: availability
                    -
                      tag: scope
                      value: performance
                -
                  uuid: a53271304dcf418aa5afdaa145436b70
                  expression: 'count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1'
                  name: 'Fan {#SNMPVALUE}: Fan is not in normal state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: INFO
                  description: 'Please check the fan unit'
                  dependencies:
                    -
                      name: 'Fan {#SNMPVALUE}: Fan is in critical state'
                      expression: 'count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
                  tags:
                    -
                      tag: scope
                      value: notice
        -
          uuid: ff38ddf97a2a47c88ad93d590dedc22a
          name: 'CPU and Memory and Flash Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.6027.3.10.1.2.9.1.1]'
          key: module.discovery
          delay: 1h
          item_prototypes:
            -
              uuid: f2f0febdd3c14d77a47461c22b883bb5
              name: '#{#SNMPINDEX}: CPU utilization'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.6027.3.10.1.2.9.1.3.{#SNMPINDEX}'
              key: 'system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: F10-S-SERIES-CHASSIS-MIB
                CPU utilization in percentage for last 1 minute.
              tags:
                -
                  tag: component
                  value: cpu
              trigger_prototypes:
                -
                  uuid: 002c0f19cfe54fe08da2183654752470
                  expression: 'min(/Dell Force S-Series SNMP/system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
                  name: '#{#SNMPINDEX}: High CPU utilization'
                  event_name: '#{#SNMPINDEX}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
                  opdata: 'Current utilization: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: 'CPU utilization is too high. The system might be slow to respond.'
                  tags:
                    -
                      tag: scope
                      value: performance
            -
              uuid: 3571d6508f07442983936fdcc2ba733f
              name: '#{#SNMPINDEX}: Memory utilization'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.6027.3.10.1.2.9.1.5.{#SNMPINDEX}'
              key: 'vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: F10-S-SERIES-CHASSIS-MIB
                Total memory usage in percentage.
              tags:
                -
                  tag: component
                  value: memory
              trigger_prototypes:
                -
                  uuid: 41baaaa2eb6246b7982ac76928fbd0f8
                  expression: 'min(/Dell Force S-Series SNMP/vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
                  name: '#{#SNMPINDEX}: High memory utilization'
                  event_name: '#{#SNMPINDEX}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
                  priority: AVERAGE
                  description: 'The system is running out of free memory.'
                  tags:
                    -
                      tag: scope
                      value: capacity
                    -
                      tag: scope
                      value: performance
          graph_prototypes:
            -
              uuid: d5ec0b9ce1f04b0abd0b4bfe6aa28f6b
              name: '#{#SNMPINDEX}: CPU utilization'
              ymin_type_1: FIXED
              ymax_type_1: FIXED
              graph_items:
                -
                  drawtype: GRADIENT_LINE
                  color: 1A7C11
                  item:
                    host: 'Dell Force S-Series SNMP'
                    key: 'system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}]'
            -
              uuid: 69c63b7fb65347cc9301b02e1f9cd45e
              name: '#{#SNMPINDEX}: Memory utilization'
              ymin_type_1: FIXED
              ymax_type_1: FIXED
              graph_items:
                -
                  drawtype: GRADIENT_LINE
                  color: 1A7C11
                  item:
                    host: 'Dell Force S-Series SNMP'
                    key: 'vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}]'
        -
          uuid: 620805730ede4c7281a1c736fcfeb130
          name: 'Network interfaces discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#IFTYPE},1.3.6.1.2.1.2.2.1.3]'
          key: net.if.discovery
          delay: 1h
          filter:
            evaltype: AND
            conditions:
              -
                macro: '{#IFADMINSTATUS}'
                value: '{$NET.IF.IFADMINSTATUS.MATCHES}'
                formulaid: A
              -
                macro: '{#IFADMINSTATUS}'
                value: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}'
                operator: NOT_MATCHES_REGEX
                formulaid: B
              -
                macro: '{#IFOPERSTATUS}'
                value: '{$NET.IF.IFOPERSTATUS.MATCHES}'
                formulaid: I
              -
                macro: '{#IFOPERSTATUS}'
                value: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}'
                operator: NOT_MATCHES_REGEX
                formulaid: J
              -
                macro: '{#IFNAME}'
                value: '{$NET.IF.IFNAME.MATCHES}'
                formulaid: G
              -
                macro: '{#IFNAME}'
                value: '{$NET.IF.IFNAME.NOT_MATCHES}'
                operator: NOT_MATCHES_REGEX
                formulaid: H
              -
                macro: '{#IFDESCR}'
                value: '{$NET.IF.IFDESCR.MATCHES}'
                formulaid: E
              -
                macro: '{#IFDESCR}'
                value: '{$NET.IF.IFDESCR.NOT_MATCHES}'
                operator: NOT_MATCHES_REGEX
                formulaid: F
              -
                macro: '{#IFALIAS}'
                value: '{$NET.IF.IFALIAS.MATCHES}'
                formulaid: C
              -
                macro: '{#IFALIAS}'
                value: '{$NET.IF.IFALIAS.NOT_MATCHES}'
                operator: NOT_MATCHES_REGEX
                formulaid: D
              -
                macro: '{#IFTYPE}'
                value: '{$NET.IF.IFTYPE.MATCHES}'
                formulaid: K
              -
                macro: '{#IFTYPE}'
                value: '{$NET.IF.IFTYPE.NOT_MATCHES}'
                operator: NOT_MATCHES_REGEX
                formulaid: L
          description: 'Discovering interfaces from IF-MIB.'
          item_prototypes:
            -
              uuid: 2130b9e384b14fd7909d421c7756284a
              name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}'
              key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]'
              delay: 3m
              history: 7d
              description: |
                MIB: IF-MIB
                The number of inbound packets which were chosen to be discarded
                even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
                One possible reason for discarding such a packet could be to free up buffer space.
                Discontinuities in the value of this counter can occur at re-initialization of the management system,
                and at other times as indicated by the value of ifCounterDiscontinuityTime.
              preprocessing:
                -
                  type: CHANGE_PER_SECOND
                  parameters:
                    - ''
              tags:
                -
                  tag: component
                  value: network
                -
                  tag: description
                  value: '{#IFALIAS}'
                -
                  tag: interface
                  value: '{#IFNAME}'
            -
              uuid: 5a61f0168e034e8baf6794cf5cc5ce70
              name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}'
              key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]'
              delay: 3m
              history: 7d
              description: |
                MIB: IF-MIB
                For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.  For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
              preprocessing:
                -
                  type: CHANGE_PER_SECOND
                  parameters:
                    - ''
              tags:
                -
                  tag: component
                  value: network
                -
                  tag: description
                  value: '{#IFALIAS}'
                -
                  tag: interface
                  value: '{#IFNAME}'
            -
              uuid: 19e183dbf814471e885f2fef4b84e759
              name: 'Interface {#IFNAME}({#IFALIAS}): Bits received'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}'
              key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]'
              delay: 3m
              history: 7d
              units: bps
              description: |
                MIB: IF-MIB
                The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
              preprocessing:
                -
                  type: CHANGE_PER_SECOND
                  parameters:
                    - ''
                -
                  type: MULTIPLIER
                  parameters:
                    - '8'
              tags:
                -
                  tag: component
                  value: network
                -
                  tag: description
                  value: '{#IFALIAS}'
                -
                  tag: interface
                  value: '{#IFNAME}'
            -
              uuid: 26135962ebd246ce82b3d101e7eb92a4
              name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}'
              key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]'
              delay: 3m
              history: 7d
              description: |
                MIB: IF-MIB
                The number of outbound packets which were chosen to be discarded
                even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
                One possible reason for discarding such a packet could be to free up buffer space.
                Discontinuities in the value of this counter can occur at re-initialization of the management system,
                and at other times as indicated by the value of ifCounterDiscontinuityTime.
              preprocessing:
                -
                  type: CHANGE_PER_SECOND
                  parameters:
                    - ''
              tags:
                -
                  tag: component
                  value: network
                -
                  tag: description
                  value: '{#IFALIAS}'
                -
                  tag: interface
                  value: '{#IFNAME}'
            -
              uuid: e3b1efbafa204424b0a61cf877ad168b
              name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}'
              key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]'
              delay: 3m
              history: 7d
              description: |
                MIB: IF-MIB
                For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.  For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
              preprocessing:
                -
                  type: CHANGE_PER_SECOND
                  parameters:
                    - ''
              tags:
                -
                  tag: component
                  value: network
                -
                  tag: description
                  value: '{#IFALIAS}'
                -
                  tag: interface
                  value: '{#IFNAME}'
            -
              uuid: 6994853a31054989b1e0fc25420f88b1
              name: 'Interface {#IFNAME}({#IFALIAS}): Bits sent'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}'
              key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]'
              delay: 3m
              history: 7d
              units: bps
              description: |
                MIB: IF-MIB
                The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
              preprocessing:
                -
                  type: CHANGE_PER_SECOND
                  parameters:
                    - ''
                -
                  type: MULTIPLIER
                  parameters:
                    - '8'
              tags:
                -
                  tag: component
                  value: network
                -
                  tag: description
                  value: '{#IFALIAS}'
                -
                  tag: interface
                  value: '{#IFNAME}'
            -
              uuid: cd36f7b9176349d1a5b69c7eef672986
              name: 'Interface {#IFNAME}({#IFALIAS}): Speed'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.2.1.31.1.1.1.15.{#SNMPINDEX}'
              key: 'net.if.speed[ifHighSpeed.{#SNMPINDEX}]'
              delay: 5m
              history: 7d
              trends: 0d
              units: bps
              description: |
                MIB: IF-MIB
                An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'.  For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '1000000'
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 1h
              tags:
                -
                  tag: component
                  value: network
                -
                  tag: description
                  value: '{#IFALIAS}'
                -
                  tag: interface
                  value: '{#IFNAME}'
            -
              uuid: cf571531ada84121a94e1084070560c0
              name: 'Interface {#IFNAME}({#IFALIAS}): Operational status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}'
              key: 'net.if.status[ifOperStatus.{#SNMPINDEX}]'
              history: 7d
              trends: '0'
              description: |
                MIB: IF-MIB
                The current operational state of the interface.
                - The testing(3) state indicates that no operational packet scan be passed
                - If ifAdminStatus is down(2) then ifOperStatus should be down(2)
                - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic
                - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection)
                - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state
                - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.
              valuemap:
                name: 'IF-MIB::ifOperStatus'
              tags:
                -
                  tag: component
                  value: network
                -
                  tag: description
                  value: '{#IFALIAS}'
                -
                  tag: interface
                  value: '{#IFNAME}'
              trigger_prototypes:
                -
                  uuid: b7b55335f42b4ace8434588bc70f7e60
                  expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
                  name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
                  description: |
                    This trigger expression works as follows:
                    1. Can be triggered if operations status is down.
                    2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.
                    3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)
                    
                    WARNING: if closed manually - won't fire again on next poll, because of .diff.
                  manual_close: 'YES'
                  tags:
                    -
                      tag: scope
                      value: availability
            -
              uuid: ec1b53ae24ff443083ab691e1826734f
              name: 'Interface {#IFNAME}({#IFALIAS}): Interface type'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.2.1.2.2.1.3.{#SNMPINDEX}'
              key: 'net.if.type[ifType.{#SNMPINDEX}]'
              delay: 1h
              history: 7d
              trends: 0d
              description: |
                MIB: IF-MIB
                The type of interface.
                Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA),
                through updating the syntax of the IANAifType textual convention.
              valuemap:
                name: 'IF-MIB::ifType'
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 1d
              tags:
                -
                  tag: component
                  value: network
                -
                  tag: description
                  value: '{#IFALIAS}'
                -
                  tag: interface
                  value: '{#IFNAME}'
          trigger_prototypes:
            -
              uuid: f4903edf173f470482174ee9937cbb32
              expression: |
                change(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
                and (
                last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or
                last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or
                last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or
                last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or
                last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or
                last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=117
                )
                and
                (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)
              recovery_mode: RECOVERY_EXPRESSION
              recovery_expression: |
                (change(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or
                (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)
              name: 'Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before'
              opdata: 'Current reported speed: {ITEM.LASTVALUE1}'
              priority: INFO
              description: 'This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.'
              manual_close: 'YES'
              dependencies:
                -
                  name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
                  expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
                  recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
              tags:
                -
                  tag: scope
                  value: performance
            -
              uuid: e85a287c2e0e48e19cb43bf74d3f3535
              expression: |
                (avg(/Dell Force S-Series SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or
                avg(/Dell Force S-Series SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and
                last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
              recovery_mode: RECOVERY_EXPRESSION
              recovery_expression: |
                avg(/Dell Force S-Series SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and
                avg(/Dell Force S-Series SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])
              name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage'
              event_name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage (>{$IF.UTIL.MAX:"{#IFNAME}"}%)'
              opdata: 'In: {ITEM.LASTVALUE1}, out: {ITEM.LASTVALUE3}, speed: {ITEM.LASTVALUE2}'
              priority: WARNING
              description: 'The network interface utilization is close to its estimated maximum bandwidth.'
              manual_close: 'YES'
              dependencies:
                -
                  name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
                  expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
                  recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
              tags:
                -
                  tag: scope
                  value: performance
            -
              uuid: 00d2988bdd084719ba781562920d20fa
              expression: |
                min(/Dell Force S-Series SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
                or min(/Dell Force S-Series SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
              recovery_mode: RECOVERY_EXPRESSION
              recovery_expression: |
                max(/Dell Force S-Series SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
                and max(/Dell Force S-Series SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
              name: 'Interface {#IFNAME}({#IFALIAS}): High error rate'
              event_name: 'Interface {#IFNAME}({#IFALIAS}): High error rate (>{$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)'
              opdata: 'errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}'
              priority: WARNING
              description: 'Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold'
              manual_close: 'YES'
              dependencies:
                -
                  name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
                  expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
                  recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
              tags:
                -
                  tag: scope
                  value: availability
                -
                  tag: scope
                  value: performance
          graph_prototypes:
            -
              uuid: 2841f46964a74c56b5d16233c924bc58
              name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
              graph_items:
                -
                  drawtype: GRADIENT_LINE
                  color: 1A7C11
                  item:
                    host: 'Dell Force S-Series SNMP'
                    key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]'
                -
                  sortorder: '1'
                  drawtype: BOLD_LINE
                  color: 2774A4
                  item:
                    host: 'Dell Force S-Series SNMP'
                    key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]'
                -
                  sortorder: '2'
                  color: F63100
                  yaxisside: RIGHT
                  item:
                    host: 'Dell Force S-Series SNMP'
                    key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]'
                -
                  sortorder: '3'
                  color: A54F10
                  yaxisside: RIGHT
                  item:
                    host: 'Dell Force S-Series SNMP'
                    key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]'
                -
                  sortorder: '4'
                  color: FC6EA3
                  yaxisside: RIGHT
                  item:
                    host: 'Dell Force S-Series SNMP'
                    key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]'
                -
                  sortorder: '5'
                  color: 6C59DC
                  yaxisside: RIGHT
                  item:
                    host: 'Dell Force S-Series SNMP'
                    key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]'
        -
          uuid: 6782ece35ded46b08a4f45a9743b1ff5
          name: 'EtherLike-MIB Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.2.1.10.7.2.1.19,{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2]'
          key: net.if.duplex.discovery
          delay: 1h
          filter:
            evaltype: AND
            conditions:
              -
                macro: '{#IFOPERSTATUS}'
                value: '1'
                formulaid: A
              -
                macro: '{#SNMPVALUE}'
                value: (2|3)
                formulaid: B
          description: 'Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered.'
          item_prototypes:
            -
              uuid: 200797ecab6f416191d2ef0c836da4f5
              name: 'Interface {#IFNAME}({#IFALIAS}): Duplex status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.2.1.10.7.2.1.19.{#SNMPINDEX}'
              key: 'net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}]'
              history: 7d
              description: |
                MIB: EtherLike-MIB
                The current mode of operation of the MAC
                entity.  'unknown' indicates that the current
                duplex mode could not be determined.
                
                Management control of the duplex mode is
                accomplished through the MAU MIB.  When
                an interface does not support autonegotiation,
                or when autonegotiation is not enabled, the
                duplex mode is controlled using
                ifMauDefaultType.  When autonegotiation is
                supported and enabled, duplex mode is controlled
                using ifMauAutoNegAdvertisedBits.  In either
                case, the currently operating duplex mode is
                reflected both in this object and in ifMauType.
                
                Note that this object provides redundant
                information with ifMauType.  Normally, redundant
                objects are discouraged.  However, in this
                instance, it allows a management application to
                determine the duplex status of an interface
                without having to know every possible value of
                ifMauType.  This was felt to be sufficiently
                valuable to justify the redundancy.
                Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus.
              valuemap:
                name: 'EtherLike-MIB::dot3StatsDuplexStatus'
              tags:
                -
                  tag: component
                  value: network
                -
                  tag: description
                  value: '{#IFALIAS}'
                -
                  tag: interface
                  value: '{#IFNAME}'
              trigger_prototypes:
                -
                  uuid: edc143c44b2d465cac94c4cf0fb588a6
                  expression: 'last(/Dell Force S-Series SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2'
                  name: 'Interface {#IFNAME}({#IFALIAS}): In half-duplex mode'
                  priority: WARNING
                  description: 'Please check autonegotiation settings and cabling'
                  manual_close: 'YES'
                  tags:
                    -
                      tag: scope
                      value: performance
          preprocessing:
            -
              type: JAVASCRIPT
              parameters:
                - |
                  try {
                      var data = JSON.parse(value);
                  }
                  catch (error) {
                      throw 'Failed to parse JSON of EtherLike-MIB discovery.';
                  }
                  var fields = ['{#SNMPVALUE}','{#IFOPERSTATUS}','{#IFALIAS}','{#IFNAME}','{#IFDESCR}'];
                  data.forEach(function (element) {
                      fields.forEach(function (field) {
                          element[field] = element[field] || '';
                      });
                  });
                  return JSON.stringify(data);
        -
          uuid: 21117a6eb71f4837971ccedfff7596f6
          name: 'PSU Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.6027.3.10.1.2.3.1.1]'
          key: psu.discovery
          delay: 1h
          description: 'A list of power supply residents in the S-series chassis.'
          item_prototypes:
            -
              uuid: 7cc5081ad6114124845beedbe4725899
              name: 'PSU {#SNMPVALUE}: Power supply status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.6027.3.10.1.2.3.1.2.{#SNMPINDEX}'
              key: 'sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}]'
              delay: 3m
              history: 2w
              trends: 0d
              description: |
                MIB: F10-S-SERIES-CHASSIS-MIB
                The status of the power supply {#SNMPVALUE}
              valuemap:
                name: 'F10-S-SERIES-CHASSIS-MIB::chSysPowerSupplyOperStatus'
              tags:
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 764f08ab7a29481fa73a63ae256ff154
                  expression: 'count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
                  name: 'PSU {#SNMPVALUE}: Power supply is in critical state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
                  description: 'Please check the power supply unit for errors'
                  tags:
                    -
                      tag: scope
                      value: availability
                    -
                      tag: scope
                      value: performance
                -
                  uuid: a7d4ac882ec24cce9839c6012c7fa562
                  expression: 'count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1'
                  name: 'PSU {#SNMPVALUE}: Power supply is not in normal state'
                  opdata: 'Current state: {ITEM.LASTVALUE1}'
                  priority: INFO
                  description: 'Please check the power supply unit for errors'
                  dependencies:
                    -
                      name: 'PSU {#SNMPVALUE}: Power supply is in critical state'
                      expression: 'count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
                  tags:
                    -
                      tag: scope
                      value: notice
        -
          uuid: a619474b839642f69e583a2c63e8b4ba
          name: 'Stack Unit Discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.6027.3.10.1.2.2.1.2]'
          key: stack.discovery
          delay: 1h
          item_prototypes:
            -
              uuid: 4eaf5b777b0c4efeb34140618e18aaa5
              name: 'Device {#SNMPVALUE}: Temperature'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.6027.3.10.1.2.2.1.14.{#SNMPINDEX}'
              key: 'sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}]'
              delay: 3m
              value_type: FLOAT
              units: °C
              description: |
                MIB: F10-S-SERIES-CHASSIS-MIB
                The temperature of the unit.
              tags:
                -
                  tag: component
                  value: temperature
              trigger_prototypes:
                -
                  uuid: dc1064de6a6b4533be812e590b96927b
                  expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
                  name: 'Device {#SNMPVALUE}: Temperature is above critical threshold'
                  event_name: 'Device {#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: HIGH
                  description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
                  tags:
                    -
                      tag: scope
                      value: availability
                    -
                      tag: scope
                      value: performance
                -
                  uuid: f4d0a2c0b1a9468990e1f6dbfef1ab75
                  expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
                  name: 'Device {#SNMPVALUE}: Temperature is above warning threshold'
                  event_name: 'Device {#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
                  dependencies:
                    -
                      name: 'Device {#SNMPVALUE}: Temperature is above critical threshold'
                      expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
                      recovery_expression: 'max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
                  tags:
                    -
                      tag: scope
                      value: availability
                    -
                      tag: scope
                      value: performance
                -
                  uuid: f1bbf02af05041ef95ff80ff18fc02a7
                  expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
                  recovery_mode: RECOVERY_EXPRESSION
                  recovery_expression: 'min(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
                  name: 'Device {#SNMPVALUE}: Temperature is too low'
                  event_name: 'Device {#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
                  opdata: 'Current value: {ITEM.LASTVALUE1}'
                  priority: AVERAGE
                  tags:
                    -
                      tag: scope
                      value: availability
                    -
                      tag: scope
                      value: performance
            -
              uuid: d6e3d7bb74b84e0c895a1b1b740f0e14
              name: '#{#SNMPVALUE}: Hardware model name'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.6027.3.10.1.2.2.1.7.{#SNMPINDEX}'
              key: 'system.hw.model[chStackUnitModelID.{#SNMPINDEX}]'
              delay: 1h
              history: 2w
              trends: '0'
              value_type: CHAR
              description: |
                MIB: F10-S-SERIES-CHASSIS-MIB
                The plugged-in model ID for this unit.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 1d
              tags:
                -
                  tag: component
                  value: system
            -
              uuid: eb6853c30dd04581b2e362d7747b40b5
              name: '#{#SNMPVALUE}: Hardware serial number'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.6027.3.10.1.2.2.1.12.{#SNMPINDEX}'
              key: 'system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]'
              delay: 1h
              history: 2w
              trends: '0'
              value_type: CHAR
              description: |
                MIB: F10-S-SERIES-CHASSIS-MIB
                The unit's serial number.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 1d
              tags:
                -
                  tag: component
                  value: system
              trigger_prototypes:
                -
                  uuid: 6f02e903dab24bf294015f43e0b52504
                  expression: 'last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]))>0'
                  name: '#{#SNMPVALUE}: Device has been replaced'
                  event_name: '#{#SNMPVALUE}: Device has been replaced (new serial number received)'
                  priority: INFO
                  description: 'Device serial number has changed. Ack to close'
                  manual_close: 'YES'
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: bd68fcd8247744cb8c10e3dfc699bc7f
              name: '#{#SNMPVALUE}: Hardware version(revision)'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.6027.3.10.1.2.2.1.21.{#SNMPINDEX}'
              key: 'system.hw.version[chStackUnitProductRev.{#SNMPINDEX}]'
              delay: 1h
              history: 2w
              trends: '0'
              value_type: CHAR
              description: |
                MIB: F10-S-SERIES-CHASSIS-MIB
                The unit manufacturer's product revision
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 1d
              tags:
                -
                  tag: component
                  value: system
            -
              uuid: 67cce945315e426f9b12456fe95a6c1a
              name: '#{#SNMPVALUE}: Operating system'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.6027.3.10.1.2.2.1.10.{#SNMPINDEX}'
              key: 'system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]'
              delay: 1h
              history: 2w
              trends: '0'
              value_type: CHAR
              description: |
                MIB: F10-S-SERIES-CHASSIS-MIB
                Current code version of this unit.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 1d
              tags:
                -
                  tag: component
                  value: os
              trigger_prototypes:
                -
                  uuid: 66049aa1d7cb45ebac1fe5292c309ba2
                  expression: 'last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]))>0'
                  name: '#{#SNMPVALUE}: Operating system description has changed'
                  priority: INFO
                  description: 'Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.'
                  manual_close: 'YES'
                  dependencies:
                    -
                      name: 'System name has changed'
                      expression: 'last(/Dell Force S-Series SNMP/system.name,#1)<>last(/Dell Force S-Series SNMP/system.name,#2) and length(last(/Dell Force S-Series SNMP/system.name))>0'
                  tags:
                    -
                      tag: scope
                      value: notice
      tags:
        -
          tag: class
          value: network
        -
          tag: target
          value: dell
        -
          tag: target
          value: force-s-series
      macros:
        -
          macro: '{$CPU.UTIL.CRIT}'
          value: '90'
        -
          macro: '{$FAN_CRIT_STATUS}'
          value: '2'
        -
          macro: '{$FAN_OK_STATUS}'
          value: '1'
        -
          macro: '{$ICMP_LOSS_WARN}'
          value: '20'
        -
          macro: '{$ICMP_RESPONSE_TIME_WARN}'
          value: '0.15'
        -
          macro: '{$IF.ERRORS.WARN}'
          value: '2'
        -
          macro: '{$IF.UTIL.MAX}'
          value: '90'
        -
          macro: '{$IFCONTROL}'
          value: '1'
        -
          macro: '{$MEMORY.UTIL.MAX}'
          value: '90'
        -
          macro: '{$NET.IF.IFADMINSTATUS.MATCHES}'
          value: '^.*'
          description: 'Ignore notPresent(6)'
        -
          macro: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}'
          value: ^2$
          description: 'Ignore down(2) administrative status'
        -
          macro: '{$NET.IF.IFALIAS.MATCHES}'
          value: '.*'
        -
          macro: '{$NET.IF.IFALIAS.NOT_MATCHES}'
          value: CHANGE_IF_NEEDED
        -
          macro: '{$NET.IF.IFDESCR.MATCHES}'
          value: '.*'
        -
          macro: '{$NET.IF.IFDESCR.NOT_MATCHES}'
          value: CHANGE_IF_NEEDED
        -
          macro: '{$NET.IF.IFNAME.MATCHES}'
          value: '^.*$'
        -
          macro: '{$NET.IF.IFNAME.NOT_MATCHES}'
          value: '(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12})'
          description: 'Filter out loopbacks, nulls, docker veth links and docker0 bridge by default'
        -
          macro: '{$NET.IF.IFOPERSTATUS.MATCHES}'
          value: '^.*$'
        -
          macro: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}'
          value: ^6$
          description: 'Ignore notPresent(6)'
        -
          macro: '{$NET.IF.IFTYPE.MATCHES}'
          value: '.*'
        -
          macro: '{$NET.IF.IFTYPE.NOT_MATCHES}'
          value: CHANGE_IF_NEEDED
        -
          macro: '{$PSU_CRIT_STATUS}'
          value: '2'
        -
          macro: '{$PSU_OK_STATUS}'
          value: '1'
        -
          macro: '{$SNMP.TIMEOUT}'
          value: 5m
        -
          macro: '{$TEMP_CRIT}'
          value: '65'
        -
          macro: '{$TEMP_CRIT_LOW}'
          value: '5'
        -
          macro: '{$TEMP_WARN}'
          value: '55'
      dashboards:
        -
          uuid: 5074235070b54485bd6c72688d013cb9
          name: 'Network interfaces'
          pages:
            -
              widgets:
                -
                  type: GRAPH_PROTOTYPE
                  width: '24'
                  height: '5'
                  fields:
                    -
                      type: INTEGER
                      name: source_type
                      value: '2'
                    -
                      type: INTEGER
                      name: columns
                      value: '1'
                    -
                      type: INTEGER
                      name: rows
                      value: '1'
                    -
                      type: GRAPH_PROTOTYPE
                      name: graphid
                      value:
                        host: 'Dell Force S-Series SNMP'
                        name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
      valuemaps:
        -
          uuid: 1962bc26a6064ee6868371f86d44dbeb
          name: 'EtherLike-MIB::dot3StatsDuplexStatus'
          mappings:
            -
              value: '1'
              newvalue: unknown
            -
              value: '2'
              newvalue: halfDuplex
            -
              value: '3'
              newvalue: fullDuplex
        -
          uuid: b389c759db0448ffbe28d4572fbfb3e9
          name: 'F10-S-SERIES-CHASSIS-MIB::chSysFanTrayOperStatus'
          mappings:
            -
              value: '1'
              newvalue: up
            -
              value: '2'
              newvalue: down
            -
              value: '3'
              newvalue: absent
        -
          uuid: 2532df482bd348ba8202c3eb2b76340b
          name: 'F10-S-SERIES-CHASSIS-MIB::chSysPowerSupplyOperStatus'
          mappings:
            -
              value: '1'
              newvalue: up
            -
              value: '2'
              newvalue: down
            -
              value: '3'
              newvalue: absent
        -
          uuid: 7f124ca304d9431386bba2edbb9b2560
          name: 'IF-MIB::ifOperStatus'
          mappings:
            -
              value: '1'
              newvalue: up
            -
              value: '2'
              newvalue: down
            -
              value: '4'
              newvalue: unknown
            -
              value: '5'
              newvalue: dormant
            -
              value: '6'
              newvalue: notPresent
            -
              value: '7'
              newvalue: lowerLayerDown
        -
          uuid: 9fde4e729aaf43cc993167d7c0bcae23
          name: 'IF-MIB::ifType'
          mappings:
            -
              value: '1'
              newvalue: other
            -
              value: '2'
              newvalue: regular1822
            -
              value: '3'
              newvalue: hdh1822
            -
              value: '4'
              newvalue: ddnX25
            -
              value: '5'
              newvalue: rfc877x25
            -
              value: '6'
              newvalue: ethernetCsmacd
            -
              value: '7'
              newvalue: iso88023Csmacd
            -
              value: '8'
              newvalue: iso88024TokenBus
            -
              value: '9'
              newvalue: iso88025TokenRing
            -
              value: '10'
              newvalue: iso88026Man
            -
              value: '11'
              newvalue: starLan
            -
              value: '12'
              newvalue: proteon10Mbit
            -
              value: '13'
              newvalue: proteon80Mbit
            -
              value: '14'
              newvalue: hyperchannel
            -
              value: '15'
              newvalue: fddi
            -
              value: '16'
              newvalue: lapb
            -
              value: '17'
              newvalue: sdlc
            -
              value: '18'
              newvalue: ds1
            -
              value: '19'
              newvalue: e1
            -
              value: '20'
              newvalue: basicISDN
            -
              value: '21'
              newvalue: primaryISDN
            -
              value: '22'
              newvalue: propPointToPointSerial
            -
              value: '23'
              newvalue: ppp
            -
              value: '24'
              newvalue: softwareLoopback
            -
              value: '25'
              newvalue: eon
            -
              value: '26'
              newvalue: ethernet3Mbit
            -
              value: '27'
              newvalue: nsip
            -
              value: '28'
              newvalue: slip
            -
              value: '29'
              newvalue: ultra
            -
              value: '30'
              newvalue: ds3
            -
              value: '31'
              newvalue: sip
            -
              value: '32'
              newvalue: frameRelay
            -
              value: '33'
              newvalue: rs232
            -
              value: '34'
              newvalue: para
            -
              value: '35'
              newvalue: arcnet
            -
              value: '36'
              newvalue: arcnetPlus
            -
              value: '37'
              newvalue: atm
            -
              value: '38'
              newvalue: miox25
            -
              value: '39'
              newvalue: sonet
            -
              value: '40'
              newvalue: x25ple
            -
              value: '41'
              newvalue: iso88022llc
            -
              value: '42'
              newvalue: localTalk
            -
              value: '43'
              newvalue: smdsDxi
            -
              value: '44'
              newvalue: frameRelayService
            -
              value: '45'
              newvalue: v35
            -
              value: '46'
              newvalue: hssi
            -
              value: '47'
              newvalue: hippi
            -
              value: '48'
              newvalue: modem
            -
              value: '49'
              newvalue: aal5
            -
              value: '50'
              newvalue: sonetPath
            -
              value: '51'
              newvalue: sonetVT
            -
              value: '52'
              newvalue: smdsIcip
            -
              value: '53'
              newvalue: propVirtual
            -
              value: '54'
              newvalue: propMultiplexor
            -
              value: '55'
              newvalue: ieee80212
            -
              value: '56'
              newvalue: fibreChannel
            -
              value: '57'
              newvalue: hippiInterface
            -
              value: '58'
              newvalue: frameRelayInterconnect
            -
              value: '59'
              newvalue: aflane8023
            -
              value: '60'
              newvalue: aflane8025
            -
              value: '61'
              newvalue: cctEmul
            -
              value: '62'
              newvalue: fastEther
            -
              value: '63'
              newvalue: isdn
            -
              value: '64'
              newvalue: v11
            -
              value: '65'
              newvalue: v36
            -
              value: '66'
              newvalue: g703at64k
            -
              value: '67'
              newvalue: g703at2mb
            -
              value: '68'
              newvalue: qllc
            -
              value: '69'
              newvalue: fastEtherFX
            -
              value: '70'
              newvalue: channel
            -
              value: '71'
              newvalue: ieee80211
            -
              value: '72'
              newvalue: ibm370parChan
            -
              value: '73'
              newvalue: escon
            -
              value: '74'
              newvalue: dlsw
            -
              value: '75'
              newvalue: isdns
            -
              value: '76'
              newvalue: isdnu
            -
              value: '77'
              newvalue: lapd
            -
              value: '78'
              newvalue: ipSwitch
            -
              value: '79'
              newvalue: rsrb
            -
              value: '80'
              newvalue: atmLogical
            -
              value: '81'
              newvalue: ds0
            -
              value: '82'
              newvalue: ds0Bundle
            -
              value: '83'
              newvalue: bsc
            -
              value: '84'
              newvalue: async
            -
              value: '85'
              newvalue: cnr
            -
              value: '86'
              newvalue: iso88025Dtr
            -
              value: '87'
              newvalue: eplrs
            -
              value: '88'
              newvalue: arap
            -
              value: '89'
              newvalue: propCnls
            -
              value: '90'
              newvalue: hostPad
            -
              value: '91'
              newvalue: termPad
            -
              value: '92'
              newvalue: frameRelayMPI
            -
              value: '93'
              newvalue: x213
            -
              value: '94'
              newvalue: adsl
            -
              value: '95'
              newvalue: radsl
            -
              value: '96'
              newvalue: sdsl
            -
              value: '97'
              newvalue: vdsl
            -
              value: '98'
              newvalue: iso88025CRFPInt
            -
              value: '99'
              newvalue: myrinet
            -
              value: '100'
              newvalue: voiceEM
            -
              value: '101'
              newvalue: voiceFXO
            -
              value: '102'
              newvalue: voiceFXS
            -
              value: '103'
              newvalue: voiceEncap
            -
              value: '104'
              newvalue: voiceOverIp
            -
              value: '105'
              newvalue: atmDxi
            -
              value: '106'
              newvalue: atmFuni
            -
              value: '107'
              newvalue: atmIma
            -
              value: '108'
              newvalue: pppMultilinkBundle
            -
              value: '109'
              newvalue: ipOverCdlc
            -
              value: '110'
              newvalue: ipOverClaw
            -
              value: '111'
              newvalue: stackToStack
            -
              value: '112'
              newvalue: virtualIpAddress
            -
              value: '113'
              newvalue: mpc
            -
              value: '114'
              newvalue: ipOverAtm
            -
              value: '115'
              newvalue: iso88025Fiber
            -
              value: '116'
              newvalue: tdlc
            -
              value: '117'
              newvalue: gigabitEthernet
            -
              value: '118'
              newvalue: hdlc
            -
              value: '119'
              newvalue: lapf
            -
              value: '120'
              newvalue: v37
            -
              value: '121'
              newvalue: x25mlp
            -
              value: '122'
              newvalue: x25huntGroup
            -
              value: '123'
              newvalue: trasnpHdlc
            -
              value: '124'
              newvalue: interleave
            -
              value: '125'
              newvalue: fast
            -
              value: '126'
              newvalue: ip
            -
              value: '127'
              newvalue: docsCableMaclayer
            -
              value: '128'
              newvalue: docsCableDownstream
            -
              value: '129'
              newvalue: docsCableUpstream
            -
              value: '130'
              newvalue: a12MppSwitch
            -
              value: '131'
              newvalue: tunnel
            -
              value: '132'
              newvalue: coffee
            -
              value: '133'
              newvalue: ces
            -
              value: '134'
              newvalue: atmSubInterface
            -
              value: '135'
              newvalue: l2vlan
            -
              value: '136'
              newvalue: l3ipvlan
            -
              value: '137'
              newvalue: l3ipxvlan
            -
              value: '138'
              newvalue: digitalPowerline
            -
              value: '139'
              newvalue: mediaMailOverIp
            -
              value: '140'
              newvalue: dtm
            -
              value: '141'
              newvalue: dcn
            -
              value: '142'
              newvalue: ipForward
            -
              value: '143'
              newvalue: msdsl
            -
              value: '144'
              newvalue: ieee1394
            -
              value: '145'
              newvalue: if-gsn
            -
              value: '146'
              newvalue: dvbRccMacLayer
            -
              value: '147'
              newvalue: dvbRccDownstream
            -
              value: '148'
              newvalue: dvbRccUpstream
            -
              value: '149'
              newvalue: atmVirtual
            -
              value: '150'
              newvalue: mplsTunnel
            -
              value: '151'
              newvalue: srp
            -
              value: '152'
              newvalue: voiceOverAtm
            -
              value: '153'
              newvalue: voiceOverFrameRelay
            -
              value: '154'
              newvalue: idsl
            -
              value: '155'
              newvalue: compositeLink
            -
              value: '156'
              newvalue: ss7SigLink
            -
              value: '157'
              newvalue: propWirelessP2P
            -
              value: '158'
              newvalue: frForward
            -
              value: '159'
              newvalue: rfc1483
            -
              value: '160'
              newvalue: usb
            -
              value: '161'
              newvalue: ieee8023adLag
            -
              value: '162'
              newvalue: bgppolicyaccounting
            -
              value: '163'
              newvalue: frf16MfrBundle
            -
              value: '164'
              newvalue: h323Gatekeeper
            -
              value: '165'
              newvalue: h323Proxy
            -
              value: '166'
              newvalue: mpls
            -
              value: '167'
              newvalue: mfSigLink
            -
              value: '168'
              newvalue: hdsl2
            -
              value: '169'
              newvalue: shdsl
            -
              value: '170'
              newvalue: ds1FDL
            -
              value: '171'
              newvalue: pos
            -
              value: '172'
              newvalue: dvbAsiIn
            -
              value: '173'
              newvalue: dvbAsiOut
            -
              value: '174'
              newvalue: plc
            -
              value: '175'
              newvalue: nfas
            -
              value: '176'
              newvalue: tr008
            -
              value: '177'
              newvalue: gr303RDT
            -
              value: '178'
              newvalue: gr303IDT
            -
              value: '179'
              newvalue: isup
            -
              value: '180'
              newvalue: propDocsWirelessMaclayer
            -
              value: '181'
              newvalue: propDocsWirelessDownstream
            -
              value: '182'
              newvalue: propDocsWirelessUpstream
            -
              value: '183'
              newvalue: hiperlan2
            -
              value: '184'
              newvalue: propBWAp2Mp
            -
              value: '185'
              newvalue: sonetOverheadChannel
            -
              value: '186'
              newvalue: digitalWrapperOverheadChannel
            -
              value: '187'
              newvalue: aal2
            -
              value: '188'
              newvalue: radioMAC
            -
              value: '189'
              newvalue: atmRadio
            -
              value: '190'
              newvalue: imt
            -
              value: '191'
              newvalue: mvl
            -
              value: '192'
              newvalue: reachDSL
            -
              value: '193'
              newvalue: frDlciEndPt
            -
              value: '194'
              newvalue: atmVciEndPt
            -
              value: '195'
              newvalue: opticalChannel
            -
              value: '196'
              newvalue: opticalTransport
            -
              value: '197'
              newvalue: propAtm
            -
              value: '198'
              newvalue: voiceOverCable
            -
              value: '199'
              newvalue: infiniband
            -
              value: '200'
              newvalue: teLink
            -
              value: '201'
              newvalue: q2931
            -
              value: '202'
              newvalue: virtualTg
            -
              value: '203'
              newvalue: sipTg
            -
              value: '204'
              newvalue: sipSig
            -
              value: '205'
              newvalue: docsCableUpstreamChannel
            -
              value: '206'
              newvalue: econet
            -
              value: '207'
              newvalue: pon155
            -
              value: '208'
              newvalue: pon622
            -
              value: '209'
              newvalue: bridge
            -
              value: '210'
              newvalue: linegroup
            -
              value: '211'
              newvalue: voiceEMFGD
            -
              value: '212'
              newvalue: voiceFGDEANA
            -
              value: '213'
              newvalue: voiceDID
            -
              value: '214'
              newvalue: mpegTransport
            -
              value: '215'
              newvalue: sixToFour
            -
              value: '216'
              newvalue: gtp
            -
              value: '217'
              newvalue: pdnEtherLoop1
            -
              value: '218'
              newvalue: pdnEtherLoop2
            -
              value: '219'
              newvalue: opticalChannelGroup
            -
              value: '220'
              newvalue: homepna
            -
              value: '221'
              newvalue: gfp
            -
              value: '222'
              newvalue: ciscoISLvlan
            -
              value: '223'
              newvalue: actelisMetaLOOP
            -
              value: '224'
              newvalue: fcipLink
            -
              value: '225'
              newvalue: rpr
            -
              value: '226'
              newvalue: qam
            -
              value: '227'
              newvalue: lmp
            -
              value: '228'
              newvalue: cblVectaStar
            -
              value: '229'
              newvalue: docsCableMCmtsDownstream
            -
              value: '230'
              newvalue: adsl2
            -
              value: '231'
              newvalue: macSecControlledIF
            -
              value: '232'
              newvalue: macSecUncontrolledIF
            -
              value: '233'
              newvalue: aviciOpticalEther
            -
              value: '234'
              newvalue: atmbond
            -
              value: '235'
              newvalue: voiceFGDOS
            -
              value: '236'
              newvalue: mocaVersion1
            -
              value: '237'
              newvalue: ieee80216WMAN
            -
              value: '238'
              newvalue: adsl2plus
            -
              value: '239'
              newvalue: dvbRcsMacLayer
            -
              value: '240'
              newvalue: dvbTdm
            -
              value: '241'
              newvalue: dvbRcsTdma
            -
              value: '242'
              newvalue: x86Laps
            -
              value: '243'
              newvalue: wwanPP
            -
              value: '244'
              newvalue: wwanPP2
            -
              value: '245'
              newvalue: voiceEBS
            -
              value: '246'
              newvalue: ifPwType
            -
              value: '247'
              newvalue: ilan
            -
              value: '248'
              newvalue: pip
            -
              value: '249'
              newvalue: aluELP
            -
              value: '250'
              newvalue: gpon
            -
              value: '251'
              newvalue: vdsl2
            -
              value: '252'
              newvalue: capwapDot11Profile
            -
              value: '253'
              newvalue: capwapDot11Bss
            -
              value: '254'
              newvalue: capwapWtpVirtualRadio
            -
              value: '255'
              newvalue: bits
            -
              value: '256'
              newvalue: docsCableUpstreamRfPort
            -
              value: '257'
              newvalue: cableDownstreamRfPort
            -
              value: '258'
              newvalue: vmwareVirtualNic
            -
              value: '259'
              newvalue: ieee802154
            -
              value: '260'
              newvalue: otnOdu
            -
              value: '261'
              newvalue: otnOtu
            -
              value: '262'
              newvalue: ifVfiType
            -
              value: '263'
              newvalue: g9981
            -
              value: '264'
              newvalue: g9982
            -
              value: '265'
              newvalue: g9983
            -
              value: '266'
              newvalue: aluEpon
            -
              value: '267'
              newvalue: aluEponOnu
            -
              value: '268'
              newvalue: aluEponPhysicalUni
            -
              value: '269'
              newvalue: aluEponLogicalLink
            -
              value: '270'
              newvalue: aluGponOnu
            -
              value: '271'
              newvalue: aluGponPhysicalUni
            -
              value: '272'
              newvalue: vmwareNicTeam
            -
              value: '277'
              newvalue: docsOfdmDownstream
            -
              value: '278'
              newvalue: docsOfdmaUpstream
            -
              value: '279'
              newvalue: gfast
            -
              value: '280'
              newvalue: sdci
            -
              value: '281'
              newvalue: xboxWireless
            -
              value: '282'
              newvalue: fastdsl
            -
              value: '283'
              newvalue: docsCableScte55d1FwdOob
            -
              value: '284'
              newvalue: docsCableScte55d1RetOob
            -
              value: '285'
              newvalue: docsCableScte55d2DsOob
            -
              value: '286'
              newvalue: docsCableScte55d2UsOob
            -
              value: '287'
              newvalue: docsCableNdf
            -
              value: '288'
              newvalue: docsCableNdr
            -
              value: '289'
              newvalue: ptm
            -
              value: '290'
              newvalue: ghn
        -
          uuid: 38ce73f0eb6b4c4a912b61b2014156fb
          name: 'Service state'
          mappings:
            -
              value: '0'
              newvalue: Down
            -
              value: '1'
              newvalue: Up
        -
          uuid: 01bced41864644fd842efed7085fda69
          name: zabbix.host.available
          mappings:
            -
              value: '0'
              newvalue: 'not available'
            -
              value: '1'
              newvalue: available
            -
              value: '2'
              newvalue: unknown
  triggers:
    -
      uuid: 4246a064d33f428c8441491402ae8090
      expression: '(last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Dell Force S-Series SNMP/system.net.uptime[sysUpTime.0])<10m)'
      name: 'Host has been restarted'
      event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
      priority: WARNING
      description: 'Uptime is less than 10 minutes.'
      manual_close: 'YES'
      dependencies:
        -
          name: 'No SNMP data collection'
          expression: 'max(/Dell Force S-Series SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
      tags:
        -
          tag: scope
          value: notice