Welcome to mirror list, hosted at ThFree Co, Russian Federation.

README.md « morningstar_tristar_mppt_snmp « morningstar « net « templates - github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
blob: 2b2777350bd48679ce8b11937d240ef57396458d (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121

# Morningstar TriStar MPPT SNMP

## Overview

For Zabbix version: 6.4 and higher  

## Setup

> See [Zabbix template operation](https://www.zabbix.com/documentation/6.4/manual/config/templates_out_of_the_box/zabbix_agent) for basic instructions.

Refer to the vendor documentation.

## Zabbix configuration

No specific Zabbix configuration is required.

### Macros used

|Name|Description|Default|
|----|-----------|-------|
|{$BATTERY.TEMP.MAX.CRIT} |<p>Battery high temperature critical value</p> |`60` |
|{$BATTERY.TEMP.MAX.WARN} |<p>Battery high temperature warning value</p> |`45` |
|{$BATTERY.TEMP.MIN.CRIT} |<p>Battery low temperature critical value</p> |`-20` |
|{$BATTERY.TEMP.MIN.WARN} |<p>Battery low temperature warning value</p> |`0` |
|{$CHARGE.STATE.CRIT} |<p>fault</p> |`4` |
|{$CHARGE.STATE.WARN} |<p>disconnect</p> |`2` |
|{$LOAD.STATE.CRIT:"fault"} |<p>fault</p> |`4` |
|{$LOAD.STATE.CRIT:"lvd"} |<p>lvd</p> |`3` |
|{$LOAD.STATE.WARN:"disconnect"} |<p>disconnect</p> |`5` |
|{$LOAD.STATE.WARN:"lvdWarning"} |<p>lvdWarning</p> |`2` |
|{$LOAD.STATE.WARN:"override"} |<p>override</p> |`7` |
|{$VOLTAGE.MAX.CRIT} |<p>-</p> |`` |
|{$VOLTAGE.MAX.WARN} |<p>-</p> |`` |
|{$VOLTAGE.MIN.CRIT} |<p>-</p> |`` |
|{$VOLTAGE.MIN.WARN} |<p>-</p> |`` |

## Template links

There are no template links in this template.

## Discovery rules

|Name|Description|Type|Key and additional info|
|----|-----------|----|----|
|Battery voltage discovery |<p>Discovery for battery voltage triggers</p> |DEPENDENT |battery.voltage.discovery<p>**Preprocessing**:</p><p>- JAVASCRIPT: `The text is too long. Please see the template.`</p> |

## Items collected

|Group|Name|Description|Type|Key and additional info|
|-----|----|-----------|----|---------------------|
|Array |Array: Voltage |<p>MIB: TRISTAR-MPPT</p><p>Description:Array Voltage</p><p>Scaling Factor:0.0054931640625</p><p>Units:V</p><p>Range:[-10, 180]</p><p>Modbus address:0x001b</p> |SNMP |array.voltage[arrayVoltage.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.005493164063`</p><p>- REGEX: `^(\d+)(\.\d{1,2})? \1\2`</p> |
|Array |Array: Array Current |<p>MIB: TRISTAR-MPPT</p><p>Description:Array Current</p><p>Scaling Factor:0.00244140625</p><p>Units:A</p><p>Range:[-10, 80]</p><p>Modbus address:0x001d</p> |SNMP |array.current[arrayCurrent.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.00244140625`</p><p>- REGEX: `^(\d+)(\.\d{1,2})? \1\2`</p> |
|Array |Array: Sweep Vmp |<p>MIB: TRISTAR-MPPT</p><p>Description:Vmp (last sweep)</p><p>Scaling Factor:0.0054931640625</p><p>Units:V</p><p>Range:[-10, 180.0]</p><p>Modbus address:0x003d</p> |SNMP |array.sweep_vmp[arrayVmpLastSweep.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.005493164063`</p><p>- REGEX: `^(\d+)(\.\d{1,2})? \1\2`</p> |
|Array |Array: Sweep Voc |<p>MIB: TRISTAR-MPPT</p><p>Description:Voc (last sweep)</p><p>Scaling Factor:0.0054931640625</p><p>Units:V</p><p>Range:[-10, 180.0]</p><p>Modbus address:0x003e</p> |SNMP |array.sweep_voc[arrayVocLastSweep.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.005493164063`</p><p>- REGEX: `^(\d+)(\.\d{1,2})? \1\2`</p> |
|Array |Array: Sweep Pmax |<p>MIB: TRISTAR-MPPT</p><p>Description:Pmax (last sweep)</p><p>Scaling Factor:0.10986328125</p><p>Units:W</p><p>Range:[-10, 5000]</p><p>Modbus address:0x003c</p> |SNMP |array.sweep_pmax[arrayPmaxLastSweep.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.1098632813`</p><p>- REGEX: `^(\d+)(\.\d{1,2})? \1\2`</p> |
|Battery |Battery: Charge State |<p>MIB: TRISTAR-MPPT</p><p>Description:Charge State</p><p>Modbus address:0x0032</p><p>0: Start</p><p>1: NightCheck</p><p>2: Disconnect</p><p>3: Night</p><p>4: Fault</p><p>5: Mppt</p><p>6: Absorption</p><p>7: Float</p><p>8: Equalize</p><p>9: Slave</p> |SNMP |charge.state[chargeState.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1h`</p> |
|Battery |Battery: Target Voltage |<p>MIB: TRISTAR-MPPT</p><p>Description:Target Voltage</p><p>Scaling Factor:0.0054931640625</p><p>Units:V</p><p>Range:[-10, 180.0]</p><p>Modbus address:0x0033</p> |SNMP |target.voltage[targetRegulationVoltage.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.005493164063`</p><p>- REGEX: `^(\d+)(\.\d{1,2})? \1\2`</p> |
|Battery |Battery: Charge Current |<p>MIB: TRISTAR-MPPT</p><p>Description:Battery Current</p><p>Scaling Factor:0.00244140625</p><p>Units:A</p><p>Range:[-10, 80]</p><p>Modbus address:0x001c</p> |SNMP |charge.current[batteryCurrent.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.00244140625`</p><p>- REGEX: `^(\d+)(\.\d{1,2})? \1\2`</p> |
|Battery |Battery: Output Power |<p>MIB: TRISTAR-MPPT</p><p>Description:Output Power</p><p>Scaling Factor:0.10986328125</p><p>Units:W</p><p>Range:[-10, 5000]</p><p>Modbus address:0x003a</p> |SNMP |charge.output_power[ outputPower.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.1098632813`</p><p>- REGEX: `^(\d+)(\.\d{1,2})? \1\2`</p> |
|Battery |Battery: Voltage{#SINGLETON} |<p>MIB: TRISTAR-MPPT</p><p>Description:Battery voltage</p><p>Scaling Factor:0.0054931640625</p><p>Units:V</p><p>Range:[-10, 180.0]</p><p>Modbus address:0x0018</p> |SNMP |battery.voltage[batteryVoltage.0{#SINGLETON}]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.005493164063`</p><p>- REGEX: `^(\d+)(\.\d{1,2})? \1\2`</p> |
|Counter |Counter: Charge Amp-hours |<p>MIB: TRISTAR-MPPT</p><p>Description:Ah Charge Resettable</p><p>Scaling Factor:0.1</p><p>Units:Ah</p><p>Range:[0.0, 5000]</p><p>Modbus addresses:H=0x0034 L=0x0035</p> |SNMP |counter.charge_amp_hours[ahChargeResetable.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.1`</p> |
|Counter |Counter: Charge KW-hours |<p>MIB: TRISTAR-MPPT</p><p>Description:kWh Charge Resettable</p><p>Scaling Factor:0.1</p><p>Units:kWh</p><p>Range:[0.0, 65535.0]</p><p>Modbus address:0x0038</p> |SNMP |counter.charge_kw_hours[kwhChargeResetable.0] |
|Status |Status: Uptime (network) |<p>The time (in hundredths of a second) since the network management portion of the system was last re-initialized.</p> |SNMP |status.net.uptime<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.01`</p> |
|Status |Status: Uptime (hardware) |<p>The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.</p> |SNMP |status.hw.uptime<p>**Preprocessing**:</p><p>- CHECK_NOT_SUPPORTED</p><p>⛔️ON_FAIL: `CUSTOM_VALUE -> 0`</p><p>- MULTIPLIER: `0.01`</p> |
|Status |Status: Faults |<p>MIB: TRISTAR-MPPT</p><p>Description:Faults</p><p>Modbus address:0x002c</p> |SNMP |status.faults[faults.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1h`</p><p>- JAVASCRIPT: `The text is too long. Please see the template.`</p> |
|Status |Status: Alarms |<p>MIB: TRISTAR-MPPT</p><p>Description:Faults</p><p>Modbus address:0x002c</p> |SNMP |status.alarms[alarms.0]<p>**Preprocessing**:</p><p>- DISCARD_UNCHANGED_HEARTBEAT: `1h`</p><p>- JAVASCRIPT: `The text is too long. Please see the template.`</p> |
|Temperature |Temperature: Battery |<p>MIB: TRISTAR-MPPT</p><p>Description:Batt. Temp</p><p>Scaling Factor:1.0</p><p>Units:C</p><p>Range:[-40, 80]</p><p>Modbus address:0x0025</p> |SNMP |temp.battery[batteryTemperature.0] |
|Temperature |Temperature: Heatsink |<p>MIB: TRISTAR-MPPT</p><p>Description:HS Temp</p><p>Scaling Factor:1.0</p><p>Units:C</p><p>Range:[-40, 80]</p><p>Modbus address:0x0023</p> |SNMP |temp.heatsink[heatsinkTemperature.0] |
|Zabbix raw items |Battery: Battery Voltage discovery |<p>MIB: TRISTAR-MPPT</p> |SNMP |battery.voltage.discovery[batteryVoltage.0]<p>**Preprocessing**:</p><p>- MULTIPLIER: `0.005493164063`</p> |

## Triggers

|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----|----|----|
|Battery: Device charge in warning state |<p>-</p> |`last(/Morningstar TriStar MPPT SNMP/charge.state[chargeState.0])={$CHARGE.STATE.WARN}` |WARNING |<p>**Depends on**:</p><p>- Battery: Device charge in critical state</p> |
|Battery: Device charge in critical state |<p>-</p> |`last(/Morningstar TriStar MPPT SNMP/charge.state[chargeState.0])={$CHARGE.STATE.CRIT}` |HIGH | |
|Battery: Low battery voltage |<p>-</p> |`max(/Morningstar TriStar MPPT SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.WARN}` |WARNING |<p>**Depends on**:</p><p>- Battery: Critically low battery voltage</p> |
|Battery: Critically low battery voltage |<p>-</p> |`max(/Morningstar TriStar MPPT SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}` |HIGH | |
|Battery: High battery voltage |<p>-</p> |`min(/Morningstar TriStar MPPT SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.WARN}` |WARNING |<p>**Depends on**:</p><p>- Battery: Critically high battery voltage</p> |
|Battery: Critically high battery voltage |<p>-</p> |`min(/Morningstar TriStar MPPT SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}` |HIGH | |
|Status: Device has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/Morningstar TriStar MPPT SNMP/status.hw.uptime)>0 and last(/Morningstar TriStar MPPT SNMP/status.hw.uptime)<10m) or (last(/Morningstar TriStar MPPT SNMP/status.hw.uptime)=0 and last(/Morningstar TriStar MPPT SNMP/status.net.uptime)<10m)` |INFO |<p>Manual close: YES</p> |
|Status: Failed to fetch data |<p>Zabbix has not received data for items for the last 5 minutes.</p> |`nodata(/Morningstar TriStar MPPT SNMP/status.net.uptime,5m)=1` |WARNING |<p>Manual close: YES</p> |
|Status: Device has "overcurrent" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","overcurrent")=2` |HIGH | |
|Status: Device has "fetShort" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","fetShort")=2` |HIGH | |
|Status: Device has "softwareFault" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","softwareFault")=2` |HIGH | |
|Status: Device has "batteryHvd" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","batteryHvd")=2` |HIGH | |
|Status: Device has "arrayHvd" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","arrayHvd")=2` |HIGH | |
|Status: Device has "dipSwitchChange" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","dipSwitchChange")=2` |HIGH | |
|Status: Device has "customSettingsEdit" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","customSettingsEdit")=2` |HIGH | |
|Status: Device has "rtsShorted" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","rtsShorted")=2` |HIGH | |
|Status: Device has "rtsDisconnected" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","rtsDisconnected")=2` |HIGH | |
|Status: Device has "eepromRetryLimit" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","eepromRetryLimit")=2` |HIGH | |
|Status: Device has "slaveControlTimeout" faults flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.faults[faults.0],#3,"like","slaveControlTimeout")=2` |HIGH | |
|Status: Device has "rtsShorted" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","rtsShorted")=2` |WARNING | |
|Status: Device has "rtsDisconnected" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","rtsDisconnected")=2` |WARNING | |
|Status: Device has "heatsinkTempSensorOpen" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorOpen")=2` |WARNING | |
|Status: Device has "heatsinkTempSensorShorted" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorShorted")=2` |WARNING | |
|Status: Device has "highTemperatureCurrentLimit" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","highTemperatureCurrentLimit")=2` |WARNING | |
|Status: Device has "currentLimit" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","currentLimit")=2` |WARNING | |
|Status: Device has "currentOffset" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","currentOffset")=2` |WARNING | |
|Status: Device has "batterySense" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","batterySense")=2` |WARNING | |
|Status: Device has "batterySenseDisconnected" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","batterySenseDisconnected")=2` |WARNING | |
|Status: Device has "uncalibrated" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","uncalibrated")=2` |WARNING | |
|Status: Device has "rtsMiswire" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","rtsMiswire")=2` |WARNING | |
|Status: Device has "highVoltageDisconnect" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","highVoltageDisconnect")=2` |WARNING | |
|Status: Device has "systemMiswire" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","systemMiswire")=2` |WARNING | |
|Status: Device has "mosfetSOpen" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","mosfetSOpen")=2` |WARNING | |
|Status: Device has "p12VoltageReferenceOff" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","p12VoltageReferenceOff")=2` |WARNING | |
|Status: Device has "highArrayVCurrentLimit" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","highArrayVCurrentLimit")=2` |WARNING | |
|Status: Device has "maxAdcValueReached" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","maxAdcValueReached")=2` |WARNING | |
|Status: Device has "controllerWasReset" alarm flag |<p>-</p> |`count(/Morningstar TriStar MPPT SNMP/status.alarms[alarms.0],#3,"like","controllerWasReset")=2` |WARNING | |
|Temperature: Low battery temperature |<p>-</p> |`max(/Morningstar TriStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.WARN}` |WARNING |<p>**Depends on**:</p><p>- Temperature: Critically low battery temperature</p> |
|Temperature: Critically low battery temperature |<p>-</p> |`max(/Morningstar TriStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}` |HIGH | |
|Temperature: High battery temperature |<p>-</p> |`min(/Morningstar TriStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.WARN}` |WARNING |<p>**Depends on**:</p><p>- Temperature: Critically high battery temperature</p> |
|Temperature: Critically high battery temperature |<p>-</p> |`min(/Morningstar TriStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}` |HIGH | |

## Feedback

Please report any issues with the template at https://support.zabbix.com