Welcome to mirror list, hosted at ThFree Co, Russian Federation.

template_power_apc_ups_smart_srt_8000_snmp.yaml « apc_ups_smart_srt_8000_snmp « apc « power « templates - github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
blob: f3e21d234b25dd2d35fb2f33f89f9fa0f753d665 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
zabbix_export:
  version: '6.4'
  date: '2022-10-27T14:24:46Z'
  template_groups:
    -
      uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
      name: Templates/Power
  templates:
    -
      uuid: b3caafda8c5345cc832ac3be3cefa615
      template: 'APC Smart-UPS SRT 8000 by SNMP'
      name: 'APC Smart-UPS SRT 8000 by SNMP'
      description: |
        Template Power APC Smart-UPS SRT 8000
        
        MIBs used:
        HOST-RESOURCES-MIB
        PowerNet-MIB
        SNMPv2-MIB
        
        You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/420730-discussion-thread-for-official-zabbix-template-apc-ups
        
        Template tooling version used: 0.42
      groups:
        -
          name: Templates/Power
      items:
        -
          uuid: c4f4a85105f24292a3b566d0d1bcc090
          name: 'Battery capacity'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.1.0
          key: 'battery.capacity[upsHighPrecBatteryCapacity]'
          history: 7d
          value_type: FLOAT
          units: '%'
          description: |
            MIB: PowerNet-MIB
            The remaining battery capacity expressed as
             percentage of full capacity.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
          triggers:
            -
              uuid: 92e6a65ffc6d4a6bae62303ee2796580
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/battery.capacity[upsHighPrecBatteryCapacity]) < {$BATTERY.CAPACITY.MIN.WARN}'
              name: 'Battery has low capacity'
              event_name: 'Battery has low capacity (below {$BATTERY.CAPACITY.MIN.WARN}%)'
              opdata: 'Current capacity: {ITEM.LASTVALUE1}'
              priority: HIGH
              tags:
                -
                  tag: scope
                  value: capacity
        -
          uuid: 7d7c2b962e9843b8a6cf72c04ff1e479
          name: 'External battery packs count'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.5.0
          key: 'battery.external_packs_count[upsAdvBatteryNumOfBattPacks]'
          delay: 1h
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The number of external battery packs connected to the UPS. If
             the UPS does not use smart cells then the agent reports
             ERROR_NO_SUCH_NAME.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: inventory
        -
          uuid: 552e030c272d43a0998bc2648f15ae44
          name: 'Battery last replace date'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.1.3.0
          key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
          delay: 1h
          history: 7d
          trends: '0'
          value_type: CHAR
          description: |
            MIB: PowerNet-MIB
            The date when the UPS system's batteries were last replaced
             in mm/dd/yy (or yyyy) format. For Smart-UPS models, this value
             is originally set at the factory. When the UPS batteries
             are replaced, this value should be reset by the administrator.
             For Symmetra PX 250/500 this OID is read-only and is configurable in the local display only.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: inventory
        -
          uuid: 4cdd4bbff845477194a6d96a31431d23
          name: 'Battery replace indicator'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.4.0
          key: 'battery.replace_indicator[upsAdvBatteryReplaceIndicator]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            Indicates whether the UPS batteries need replacement.
          valuemap:
            name: 'PowerNet-MIB::upsAdvBatteryReplaceIndicator'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
          triggers:
            -
              uuid: 0e8030c0028144728361153c2b47016b
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/battery.replace_indicator[upsAdvBatteryReplaceIndicator])=2'
              name: 'Battery needs replacement'
              priority: HIGH
              description: 'A battery installed has an internal error condition.'
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: ae8a19896d21405ca99a5bfbd5de1f95
          name: 'Battery runtime remaining'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.3.0
          key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
          history: 7d
          value_type: FLOAT
          units: s
          description: |
            MIB: PowerNet-MIB
            The UPS battery run time remaining before battery
             exhaustion.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.01'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
        -
          uuid: ceed5ddfc9964aabaebb0b97875b1bd9
          name: 'Battery status'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.1.1.0
          key: 'battery.status[upsBasicBatteryStatus]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The status of the UPS batteries. A batteryLow(3) value
             indicates the UPS will be unable to sustain the current
             load, and its services will be lost if power is not restored.
             The amount of run time in reserve at the time of low battery
             can be configured by the upsAdvConfigLowBatteryRunTime.
             A batteryInFaultCondition(4)value indicates that a battery
             installed has an internal error condition.
          valuemap:
            name: 'PowerNet-MIB::upsBasicBatteryStatus'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: health
            -
              tag: component
              value: power
          triggers:
            -
              uuid: cf186014cfd94ccbad3cc4cbd22b6aa1
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/battery.status[upsBasicBatteryStatus])=4'
              name: 'Battery has an internal error condition'
              priority: AVERAGE
              description: 'A battery installed has an internal error condition.'
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: e1957ee82be847e7bfb171560fc59293
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/battery.status[upsBasicBatteryStatus])=3'
              name: 'Battery is Low'
              priority: AVERAGE
              description: 'The UPS will be unable to sustain the current load, and its services will be lost if power is not restored.'
              tags:
                -
                  tag: scope
                  value: capacity
        -
          uuid: 533041b6831c451cb72991d3fdeca535
          name: 'Battery temperature'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.2.0
          key: 'battery.temperature[upsHighPrecBatteryTemperature]'
          history: 7d
          value_type: FLOAT
          units: ℃
          description: |
            MIB: PowerNet-MIB
            The current internal UPS temperature in Celsius.
             Temperatures below zero read as 0.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: temperature
          triggers:
            -
              uuid: 1e883961b65e445997c57870734a58ca
              expression: 'min(/APC Smart-UPS SRT 8000 by SNMP/battery.temperature[upsHighPrecBatteryTemperature],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}'
              name: 'Battery has high temperature'
              event_name: 'Battery has high temperature (over {$BATTERY.TEMP.MAX.WARN}℃ for {$TIME.PERIOD})'
              opdata: 'Current temperature: {ITEM.LASTVALUE1}'
              priority: HIGH
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: fa8256c826954defa82083ddc742624e
          name: 'Battery voltage'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.4.0
          key: 'battery.voltage[upsHighPrecBatteryActualVoltage]'
          history: 7d
          value_type: FLOAT
          units: V
          description: |
            MIB: PowerNet-MIB
            The actual battery bus voltage in Volts.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
        -
          uuid: 07754bb421d0435995abbc49d4597908
          name: 'Input fail cause'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.2.5.0
          key: 'input.fail[upsAdvInputLineFailCause]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The reason for the occurrence of the last transfer to UPS
            battery power.  The variable is set to:
            - noTransfer(1) -- if there is no transfer yet.
            - highLineVoltage(2) -- if the transfer to battery is caused
            by an over voltage greater than the high transfer voltage.
            - brownout(3) -- if the duration of the outage is greater than
            five seconds and the line voltage is between 40% of the
            rated output voltage and the low transfer voltage.
            - blackout(4) -- if the duration of the outage is greater than five
            seconds and the line voltage is between 40% of the rated
            output voltage and ground.
            - smallMomentarySag(5) -- if the duration of the outage is less
            than five seconds and the line voltage is between 40% of the
            rated output voltage and the low transfer voltage.
            - deepMomentarySag(6) -- if the duration of the outage is less
            than five seconds and the line voltage is between 40% of the
            rated output voltage and ground.  The variable is set to
            - smallMomentarySpike(7) -- if the line failure is caused by a
            rate of change of input voltage less than ten volts per cycle.
            - largeMomentarySpike(8) -- if the line failure is caused by
            a rate of change of input voltage greater than ten volts per cycle.
            - selfTest(9) -- if the UPS was commanded to do a self test.
            - rateOfVoltageChange(10) -- if the failure is due to the rate of change of
            the line voltage.
          valuemap:
            name: 'PowerNet-MIB::upsAdvInputLineFailCause'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
        -
          uuid: 7574344f67544554804c4c68e39d3d72
          name: 'Input frequency'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.3.4.0
          key: 'input.frequency[upsHighPrecInputFrequency]'
          history: 7d
          value_type: FLOAT
          units: Hz
          description: |
            MIB: PowerNet-MIB
            The current input frequency to the UPS system in Hz.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
          triggers:
            -
              uuid: b9a134c942da46ffba1acdf85a7832e4
              expression: 'min(/APC Smart-UPS SRT 8000 by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > 0 and (min(/APC Smart-UPS SRT 8000 by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > {$UPS.INPUT_FREQ.MAX.WARN} or max(/APC Smart-UPS SRT 8000 by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) < {$UPS.INPUT_FREQ.MIN.WARN})'
              name: 'Unacceptable input frequency'
              event_name: 'Unacceptable input frequency (out of range {$UPS.INPUT_FREQ.MIN.WARN}-{$UPS.INPUT_FREQ.MAX.WARN}Hz for {$TIME.PERIOD})'
              opdata: 'Current frequency: {ITEM.LASTVALUE1}'
              priority: HIGH
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: c69418651f75413e95645c62fa3fee7f
          name: 'Input voltage'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.3.1.0
          key: 'input.voltage[upsHighPrecInputLineVoltage]'
          history: 7d
          value_type: FLOAT
          units: V
          description: |
            MIB: PowerNet-MIB
            The current utility line voltage in VAC.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
          triggers:
            -
              uuid: 694ab76079b1447b99ef510d80faab6a
              expression: 'min(/APC Smart-UPS SRT 8000 by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > 0 and (min(/APC Smart-UPS SRT 8000 by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 8000 by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN})'
              name: 'Unacceptable input voltage'
              event_name: 'Unacceptable input voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})'
              opdata: 'Current voltage: {ITEM.LASTVALUE1}'
              priority: HIGH
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: e4d76d857c4e46fd9b0e97405b17988a
          name: 'Output current'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.3.4.0
          key: 'output.current[upsHighPrecOutputCurrent]'
          history: 7d
          value_type: FLOAT
          units: A
          description: |
            MIB: PowerNet-MIB
            The current in amperes drawn by the load on the UPS.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
        -
          uuid: 0413f6ef89894dc6ba51e42f6a963f94
          name: 'Output load'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.3.3.0
          key: 'output.load[upsHighPrecOutputLoad]'
          history: 7d
          value_type: FLOAT
          units: '%'
          description: |
            MIB: PowerNet-MIB
            The current UPS load expressed as percentage
            of rated capacity.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
          triggers:
            -
              uuid: 68f92026e7b345c88bf4aa679f9b642c
              expression: 'min(/APC Smart-UPS SRT 8000 by SNMP/output.load[upsHighPrecOutputLoad],{$TIME.PERIOD}) > {$UPS.OUTPUT.MAX.WARN}'
              name: 'Output load is high'
              event_name: 'Output load is high (over {$UPS.OUTPUT.MAX.WARN}% for {$TIME.PERIOD})'
              opdata: 'Current load: {ITEM.LASTVALUE1}'
              priority: HIGH
              description: 'A battery installed has an internal error condition.'
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: 11c1742beed041999375e5a1ede42546
          name: 'Output status'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.1.1.0
          key: 'output.status[upsBasicOutputStatus]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The current state of the UPS. If the UPS is unable to
             determine the state of the UPS this variable is set
             to unknown(1).
            During self-test most UPSes report onBattery(3) but
             some that support it will report onBatteryTest(15).
             To determine self-test status across all UPSes, refer
             to the upsBasicStateOutputState OID.
          valuemap:
            name: 'PowerNet-MIB::upsBasicOutputStatus'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: health
            -
              tag: component
              value: power
          triggers:
            -
              uuid: 9952679fada845228bbbf05bcdada305
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=16'
              name: 'UPS is Emergency Static Bypass'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: ee306606159f4930bcf580b5084c846a
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=10'
              name: 'UPS is Hardware Failure Bypass'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: c4623dc4c6ae4c5b9ff4bdf4f43ed8b2
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=7'
              name: 'UPS is Off'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 26c0b9b62d864c1ead7b16e0076a7226
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=3'
              name: 'UPS is on battery'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 5c8408069c03421cb60b388451869b6f
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=4'
              name: 'UPS is on Smart Boost'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 156c5260ed4444c19313ba491ce9352c
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=12'
              name: 'UPS is On Smart Trim'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: c233bc86198140659ec3dd609c94ec94
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=8'
              name: 'UPS is Rebooting'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 944e49d1b6d44adc8d720bd689d8c8cf
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=11'
              name: 'UPS is Sleeping Until Power Return'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 9b376dbd2d614878b681b42bb2c7fe4d
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=6'
              name: 'UPS is Software Bypass'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 499ac46836c1454dad3c1ffc5714c073
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=9'
              name: 'UPS is Switched Bypass'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 8a0a5af39647494681e52595d179c336
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/output.status[upsBasicOutputStatus])=5'
              name: 'UPS is Timed Sleeping'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: 07059c625de94e618925249492982fb7
          name: 'Output voltage'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.3.1.0
          key: 'output.voltage[upsHighPrecOutputVoltage]'
          history: 7d
          value_type: FLOAT
          units: V
          description: |
            MIB: PowerNet-MIB
            The output voltage of the UPS system in VAC.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
        -
          uuid: ae4579b14c424c0492acbfcb5aa5dd67
          name: 'SNMP traps (fallback)'
          type: SNMP_TRAP
          key: snmptrap.fallback
          history: 2w
          trends: '0'
          value_type: LOG
          description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items'
          logtimefmt: 'hh:mm:sszyyyy/MM/dd'
          tags:
            -
              tag: component
              value: network
        -
          uuid: e4995e72f6b442bd9b8c90f09eb54f16
          name: 'System contact details'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.4.0
          key: 'system.contact[sysContact.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The textual identification of the contact person for this managed
            node, together with information on how to contact this person.  If no contact
            information is known, the value is the zero-length string.
          inventory_link: CONTACT
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 12h
          tags:
            -
              tag: component
              value: system
        -
          uuid: 13d3c18413a249d492272a7373ebd772
          name: 'System description'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.1.0
          key: 'system.descr[sysDescr.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            A textual description of the entity. This value should
            include the full name and version identification of the system's hardware type, software operating-system, and
            networking software.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 12h
          tags:
            -
              tag: component
              value: system
        -
          uuid: 4e8b6d6a5aa24159b048d1cf28e9418a
          name: 'Uptime (hardware)'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.25.1.1.0
          key: 'system.hw.uptime[hrSystemUptime.0]'
          delay: 30s
          history: 2w
          trends: 0d
          units: uptime
          description: |
            MIB: HOST-RESOURCES-MIB
            The amount of time since this host was last initialized.
            Note that this is different from sysUpTime in the SNMPv2-MIB
            [RFC1907] because sysUpTime is the uptime of the
            network management portion of the system.
          preprocessing:
            -
              type: CHECK_NOT_SUPPORTED
              parameters:
                - ''
              error_handler: CUSTOM_VALUE
              error_handler_params: '0'
            -
              type: MULTIPLIER
              parameters:
                - '0.01'
          tags:
            -
              tag: component
              value: system
        -
          uuid: 25aa469a757347089191eb8e364d4df9
          name: 'System location'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.6.0
          key: 'system.location[sysLocation.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The physical location of this node (e.g., `telephone closet,
            3rd floor').  If the location is unknown, the value is the zero-length string.
          inventory_link: LOCATION
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: system
        -
          uuid: 57f3c4c2aff04eef83b7a7a53fa9f95c
          name: Model
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.1.1.1.0
          key: 'system.model[upsBasicIdentModel]'
          delay: 15m
          history: 7d
          trends: '0'
          value_type: CHAR
          description: |
            MIB: PowerNet-MIB
            The UPS model name (e.g. 'APC Smart-UPS 600').
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: inventory
        -
          uuid: 13c26820947442f581c2234c38c052cc
          name: 'System name'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.5.0
          key: 'system.name[sysName.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            An administratively-assigned name for this managed node.By
            convention, this is the node's fully-qualified domain name.  If the name is unknown,
            the value is the zero-length string.
          inventory_link: NAME
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: system
          triggers:
            -
              uuid: 852083234a55441aa2fa57b202227bef
              expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/system.name[sysName.0],#1)<>last(/APC Smart-UPS SRT 8000 by SNMP/system.name[sysName.0],#2) and length(last(/APC Smart-UPS SRT 8000 by SNMP/system.name[sysName.0]))>0'
              name: 'System name has changed'
              event_name: 'System name has changed (new name: {ITEM.VALUE})'
              priority: INFO
              description: 'System name has changed. Ack to close.'
              manual_close: 'YES'
              tags:
                -
                  tag: scope
                  value: notice
                -
                  tag: scope
                  value: security
        -
          uuid: 320bdbfd8076411bb1dd63fccddec126
          name: 'Uptime (network)'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.3.0
          key: 'system.net.uptime[sysUpTime.0]'
          delay: 30s
          history: 2w
          trends: 0d
          units: uptime
          description: |
            MIB: SNMPv2-MIB
            The time (in hundredths of a second) since the network management
            portion of the system was last re-initialized.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.01'
          tags:
            -
              tag: component
              value: system
        -
          uuid: b59b3801f5584321a1fca9bdb466f191
          name: 'System object ID'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.2.0
          key: 'system.objectid[sysObjectID.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The vendor's authoritative identification of the network management
            subsystem contained in the entity.  This value is allocated within the SMI enterprises
            subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what
            kind of box' is being managed.  For example, if vendor`Flintstones, Inc.' was
            assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1
            to its `Fred Router'.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: system
        -
          uuid: 63852531159c44f1beca7facd8f93fa2
          name: 'Serial number'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.1.2.3.0
          key: 'system.sn[upsAdvIdentSerialNumber]'
          delay: 15m
          history: 7d
          trends: '0'
          value_type: CHAR
          description: |
            MIB: PowerNet-MIB
            An 8-character string identifying the serial number of
             the UPS internal microprocessor.  This number is set at
             the factory.  NOTE: This number does NOT correspond to
             the serial number on the rear of the UPS.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: inventory
        -
          uuid: 567996748402435d80aae37818d4125e
          name: 'SNMP agent availability'
          type: INTERNAL
          key: 'zabbix[host,snmp,available]'
          history: 7d
          description: |
            Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
            Possible value:
            0 - not available
            1 - available
            2 - unknown
          valuemap:
            name: zabbix.host.available
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: health
            -
              tag: component
              value: network
          triggers:
            -
              uuid: 9a0cb26712c14045a18a0e86de4cdd54
              expression: 'max(/APC Smart-UPS SRT 8000 by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
              name: 'No SNMP data collection'
              opdata: 'Current state: {ITEM.LASTVALUE1}'
              priority: WARNING
              description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
              tags:
                -
                  tag: scope
                  value: availability
      discovery_rules:
        -
          uuid: 912994ce460742ebbb91c89d28d87d73
          name: 'External bad battery packs discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#EXTERNAL_PACKS},1.3.6.1.4.1.318.1.1.1.2.2.6]'
          key: battery.packs.bad.discovery
          delay: 1h
          description: 'Discovery of the number of external defective battery packs.'
          item_prototypes:
            -
              uuid: e74988ed369b429893ca495a57ae9a52
              name: '{#SNMPINDEX}: External battery packs bad'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.6.0
              key: 'battery.external_packs_bad[upsAdvBatteryNumOfBadBattPacks.{#SNMPINDEX}]'
              delay: 15m
              history: 7d
              description: |
                MIB: PowerNet-MIB
                The number of external battery packs connected to the UPS that
                are defective. If the UPS does not use smart cells then the
                agent reports ERROR_NO_SUCH_NAME.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: inventory
        -
          uuid: abfe041a98dc4023b21ec6d9e829a94a
          name: 'External battery packs discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#CARTRIDGE_STATUS},1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.7,{#BATTERY_PACK},1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.1,{#CARTRIDGE_INDEX},1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.2]'
          key: battery.packs.discovery
          delay: 1h
          filter:
            evaltype: AND
            conditions:
              -
                macro: '{#CARTRIDGE_STATUS}'
                value: ^$
                operator: NOT_MATCHES_REGEX
                formulaid: A
          item_prototypes:
            -
              uuid: b3835f9b8e9c41c98a747c37feaedb50
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery estimated replace date'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.8.{#SNMPINDEX}'
              key: 'battery.estimated_replace_date[upsHighPrecBatteryPackCartridgeReplaceDate.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              delay: 1h
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery cartridge estimated battery replace date.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: inventory
                -
                  tag: component
                  value: power
            -
              uuid: 820d8eda050b41a3a9ba2889e290a28a
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery pack cartridge health'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.7.{#SNMPINDEX}'
              key: 'battery.pack.cartridge_health[upsHighPrecBatteryPackCartridgeHealth.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery cartridge health.
                  bit 0 Battery lifetime okay
                  bit 1 Battery lifetime near end, order replacement cartridge
                  bit 2 Battery lifetime exceeded, replace battery
                  bit 3 Battery lifetime near end acknowledged, order replacement cartridge
                  bit 4 Battery lifetime exceeded acknowledged, replace battery
                  bit 5 Battery measured lifetime near end, order replacement cartridge
                  bit 6 Battery measured lifetime near end acknowledged, order replacement cartridge
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: health
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 2d9c4ef006994ebea581b895424203f3
                  expression: 'find(/APC Smart-UPS SRT 8000 by SNMP/battery.pack.cartridge_health[upsHighPrecBatteryPackCartridgeHealth.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0)[0|1]{15}$")=1'
                  name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery lifetime is not okay'
                  opdata: 'Current bit set: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: |
                    The battery cartridge health.
                      bit 0 Battery lifetime okay
                      bit 1 Battery lifetime near end, order replacement cartridge
                      bit 2 Battery lifetime exceeded, replace battery
                      bit 3 Battery lifetime near end acknowledged, order replacement cartridge
                      bit 4 Battery lifetime exceeded acknowledged, replace battery
                      bit 5 Battery measured lifetime near end, order replacement cartridge
                      bit 6 Battery measured lifetime near end acknowledged, order replacement cartridge
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: cf709f051aa242799cf14ba923d9a0c0
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.10.{#SNMPINDEX}'
              key: 'battery.pack.status[upsHighPrecBatteryPackCartridgeStatus.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery cartridge status.
                bit 0 Disconnected
                bit 1 Overvoltage
                bit 2 NeedsReplacement
                bit 3 OvertemperatureCritical
                bit 4 Charger
                bit 5 TemperatureSensor
                bit 6 BusSoftStart
                bit 7 OvertemperatureWarning
                bit 8 GeneralError
                bit 9 Communication
                bit 10 DisconnectedFrame
                bit 11 FirmwareMismatch
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: health
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 5358b97f94aa47f59351be88673407a0
                  expression: 'find(/APC Smart-UPS SRT 8000 by SNMP/battery.pack.status[upsHighPrecBatteryPackCartridgeStatus.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0{16})$")=0'
                  name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery status is not okay'
                  opdata: 'Current bit set: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: |
                    The battery cartridge status:
                    bit 0 Disconnected
                    bit 1 Overvoltage
                    bit 2 NeedsReplacement
                    bit 3 OvertemperatureCritical
                    bit 4 Charger
                    bit 5 TemperatureSensor
                    bit 6 BusSoftStart
                    bit 7 OvertemperatureWarning
                    bit 8 GeneralError
                    bit 9 Communication
                    bit 10 DisconnectedFrame
                    bit 11 FirmwareMismatch
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: 99c570ed628343e99ac086167cec51ee
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery temperature'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.5.{#SNMPINDEX}'
              key: 'battery.temperature[upsHighPrecBatteryPackTemperature.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              history: 7d
              value_type: FLOAT
              units: ℃
              description: |
                MIB: PowerNet-MIB
                The battery pack temperature in Celsius.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.1'
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: temperature
              trigger_prototypes:
                -
                  uuid: b88678e600694bc19ebaf57472d8658f
                  expression: 'min(/APC Smart-UPS SRT 8000 by SNMP/battery.temperature[upsHighPrecBatteryPackTemperature.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}'
                  name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery has high temperature'
                  event_name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery has high temperature (over {$BATTERY.TEMP.MAX.WARN}℃ for {$TIME.PERIOD})'
                  opdata: 'Current temperature: {ITEM.LASTVALUE1}'
                  priority: HIGH
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: 597b33ec3d4c4f79bc0acc36edaa6dec
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Serial number'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.4.{#SNMPINDEX}'
              key: 'system.sn[upsHighPrecBatteryPackSerialNumber.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              delay: 15m
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery pack serial number.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: inventory
        -
          uuid: 52e5451d8c7a41478ef9dde6a3c16378
          name: 'External sensor port 1 discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#EXTERNAL_SENSOR1_NAME},1.3.6.1.4.1.318.1.1.25.1.2.1.3]'
          key: external.sensor1.discovery
          delay: 1h
          description: uioSensorStatusTable
          item_prototypes:
            -
              uuid: 418b37fbca594f6288eeccdbe272bad7
              name: '{#EXTERNAL_SENSOR1_NAME}: Humidity sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.1.7.1.1
              key: 'external.sensor.humidity[uioSensorStatusHumidity.1.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: PowerNet-MIB
                The sensor's current humidity reading - a relative humidity
                 percentage. -1 indicates an invalid reading due to either a
                 sensor that doesn't read humidity or lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: humidity
                -
                  tag: component
                  value: power
            -
              uuid: 53102fe478cf47bd9fbe5240aab7cf65
              name: '{#EXTERNAL_SENSOR1_NAME}: Sensor alarm status'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.1.9.1.1
              key: 'external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}]'
              history: 7d
              description: |
                MIB: PowerNet-MIB
                The alarm status of the sensor. Possible values:
                uioNormal                 (1),
                uioWarning                (2),
                uioCritical               (3),
                sensorStatusNotApplicable (4)
              valuemap:
                name: 'PowerNet-MIB::uioSensorStatusAlarmStatus'
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: health
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 33f4ac80a8d44752b97bc4f885a8c95f
                  expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=3'
                  name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Critical'
                  priority: HIGH
                  description: 'The external sensor has returned a value greater than the critical threshold.'
                  tags:
                    -
                      tag: scope
                      value: notice
                -
                  uuid: 1a2080a561394f8c8a0dc639cbf2c812
                  expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=4'
                  name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Not Applicable'
                  priority: INFO
                  description: 'The external sensor does not work or is not connected.'
                  tags:
                    -
                      tag: scope
                      value: notice
                -
                  uuid: a53d5dd33e8548d5bcb73ffb936af910
                  expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=2'
                  name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Warning'
                  priority: AVERAGE
                  description: 'The external sensor has returned a value greater than the warning threshold.'
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: 0f44bfc0e17b47919e83246046209bbf
              name: '{#EXTERNAL_SENSOR1_NAME}: Temperature sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.1.6.1.1
              key: 'external.sensor.temperature[uioSensorStatusTemperatureDegC.1.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: ℃
              description: |
                MIB: PowerNet-MIB
                The sensor's current temperature reading in Celsius.
                 -1 indicates an invalid reading due to lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
                -
                  tag: component
                  value: temperature
          overrides:
            -
              name: Temp
              step: '1'
              filter:
                conditions:
                  -
                    macro: '{#EXTERNAL_SENSOR1_NAME}'
                    value: Temp
                    formulaid: A
              operations:
                -
                  operationobject: ITEM_PROTOTYPE
                  operator: LIKE
                  value: Humidity
                  discover: NO_DISCOVER
        -
          uuid: 39f516180a1b4727907b1e2974111fe1
          name: 'External sensor port 2 discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#EXTERNAL_SENSOR2_NAME},1.3.6.1.4.1.318.1.1.25.1.2.2.3]'
          key: external.sensor2.discovery
          delay: 1h
          description: uioSensorStatusTable
          item_prototypes:
            -
              uuid: 2263b22a266a4db091f05522a024a1e4
              name: '{#EXTERNAL_SENSOR2_NAME}: Humidity sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.2.7.1.1
              key: 'external.sensor.humidity[uioSensorStatusHumidity.2.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: PowerNet-MIB
                The sensor's current humidity reading - a relative humidity
                 percentage. -1 indicates an invalid reading due to either a
                 sensor that doesn't read humidity or lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: humidity
                -
                  tag: component
                  value: power
            -
              uuid: b7af85f894194cf39c369fcba0401cc5
              name: '{#EXTERNAL_SENSOR2_NAME}: Sensor alarm status'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.2.9.1.1
              key: 'external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}]'
              history: 7d
              description: |
                MIB: PowerNet-MIB
                The alarm status of the sensor. Possible values:
                uioNormal                 (1),
                uioWarning                (2),
                uioCritical               (3),
                sensorStatusNotApplicable (4)
              valuemap:
                name: 'PowerNet-MIB::uioSensorStatusAlarmStatus'
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: health
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 9247973676c44377a4fa550990384eeb
                  expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=3'
                  name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Critical'
                  priority: HIGH
                  description: 'The external sensor has returned a value greater than the critical threshold.'
                  tags:
                    -
                      tag: scope
                      value: notice
                -
                  uuid: 6b054505c2704c8d8e38b096885bbbe5
                  expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=4'
                  name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Not Applicable'
                  priority: INFO
                  description: 'The external sensor does not work or is not connected.'
                  tags:
                    -
                      tag: scope
                      value: notice
                -
                  uuid: f56f165d71084b75a716d04337f5fcb1
                  expression: 'last(/APC Smart-UPS SRT 8000 by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=2'
                  name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Warning'
                  priority: AVERAGE
                  description: 'The external sensor has returned a value greater than the warning threshold.'
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: 84af771eee61470d9a61cede04718d88
              name: '{#EXTERNAL_SENSOR2_NAME}: Temperature sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.2.6.1.1
              key: 'external.sensor.temperature[uioSensorStatusTemperatureDegC.2.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: ℃
              description: |
                MIB: PowerNet-MIB
                The sensor's current temperature reading in Celsius.
                 -1 indicates an invalid reading due to lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
                -
                  tag: component
                  value: temperature
          overrides:
            -
              name: Temp
              step: '1'
              filter:
                conditions:
                  -
                    macro: '{#EXTERNAL_SENSOR2_NAME}'
                    value: Temp
                    formulaid: A
              operations:
                -
                  operationobject: ITEM_PROTOTYPE
                  operator: LIKE
                  value: Humidity
                  discover: NO_DISCOVER
        -
          uuid: 10363e965d97464a9344baa5fa7a2f53
          name: 'Input phases discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#PHASEINDEX},1.3.6.1.4.1.318.1.1.1.9.2.3.1.2.1.1]'
          key: input.phases.discovery
          delay: 1h
          description: 'The input phase identifier. OID upsPhaseInputPhaseIndex.1.1'
          item_prototypes:
            -
              uuid: a275ab18a7064706bf721498ac7c5605
              name: '{#PHASEINDEX}: Phase input current'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.2.3.1.6.1.1.{#PHASEINDEX}'
              key: 'phase.input.current[upsPhaseInputCurrent.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: A
              description: |
                MIB: PowerNet-MIB
                The input current in 0.1 amperes, or -0.1 if it's
                 unsupported by this UPS.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.1'
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
            -
              uuid: 113adf39a65548abab2da39aec20c169
              name: '{#PHASEINDEX}: Phase input voltage'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.2.3.1.3.1.1.{#PHASEINDEX}'
              key: 'phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: V
              description: |
                MIB: PowerNet-MIB
                The input voltage in VAC, or -1 if it's unsupported
                 by this UPS.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 755f972a32904dbf81a6da77f4ba57f0
                  expression: 'min(/APC Smart-UPS SRT 8000 by SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 8000 by SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}'
                  name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage'
                  event_name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})'
                  opdata: 'Current phase {#PHASEINDEX} voltage: {ITEM.LASTVALUE1}'
                  priority: HIGH
                  tags:
                    -
                      tag: scope
                      value: notice
        -
          uuid: 0a3159e22ba640e2840789b63bee2bda
          name: 'Output phases discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#PHASEINDEX},1.3.6.1.4.1.318.1.1.1.9.3.3.1.2.1.1]'
          key: output.phases.discovery
          delay: 1h
          description: 'The output phase identifier. OID upsPhaseOutputPhaseIndex.1.1'
          item_prototypes:
            -
              uuid: 3b625f8ab9f54dca882534d78ee0e584
              name: '{#PHASEINDEX}: Phase output current'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.3.3.1.4.1.1.{#PHASEINDEX}'
              key: 'phase.output.current[upsPhaseOutputCurrent.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: A
              description: |
                MIB: PowerNet-MIB
                The output current in 0.1 amperes drawn
                 by the load on the UPS, or -1 if it's unsupported
                 by this UPS.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.1'
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
            -
              uuid: 99357a267db04c8ca9385aaa15116b79
              name: '{#PHASEINDEX}: Phase output load, %'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.3.3.1.10.1.1.{#PHASEINDEX}'
              key: 'phase.output.load.percent[upsPhaseOutputPercentLoad.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: PowerNet-MIB
                The percentage of the UPS load capacity in VA at
                 redundancy @ (n + x) presently being used on this
                 output phase, or -1 if it's unsupported by this UPS.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
            -
              uuid: 13315206a94948a09fbb4a9843d2e149
              name: '{#PHASEINDEX}: Phase output voltage'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.3.3.1.3.1.1.{#PHASEINDEX}'
              key: 'phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: V
              description: |
                MIB: PowerNet-MIB
                The output voltage in VAC, or -1 if it's unsupported
                 by this UPS.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 5846a7a3d56f43de8394823ed64a11ae
                  expression: 'min(/APC Smart-UPS SRT 8000 by SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC Smart-UPS SRT 8000 by SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}'
                  name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage'
                  event_name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})'
                  opdata: 'Current phase {#PHASEINDEX} voltage: {ITEM.LASTVALUE1}'
                  priority: HIGH
                  tags:
                    -
                      tag: scope
                      value: notice
      tags:
        -
          tag: class
          value: power
        -
          tag: target
          value: apc
        -
          tag: target
          value: apc-smart-ups-srt-8000
      macros:
        -
          macro: '{$BATTERY.CAPACITY.MIN.WARN}'
          value: '50'
          description: 'Minimum battery capacity percentage for trigger expression.'
        -
          macro: '{$BATTERY.TEMP.MAX.WARN}'
          value: '55'
          description: 'Maximum battery temperature for trigger expression.'
        -
          macro: '{$SNMP.TIMEOUT}'
          value: 5m
          description: 'The time interval for SNMP agent availability trigger expression.'
        -
          macro: '{$TIME.PERIOD}'
          value: 15m
          description: 'Time period for trigger expression.'
        -
          macro: '{$UPS.INPUT_FREQ.MAX.WARN}'
          value: '50.3'
          description: 'Maximum input frequency for trigger expression.'
        -
          macro: '{$UPS.INPUT_FREQ.MIN.WARN}'
          value: '49.7'
          description: 'Minimum input frequency for trigger expression.'
        -
          macro: '{$UPS.INPUT_VOLT.MAX.WARN}'
          value: '243'
          description: 'Maximum input voltage for trigger expression.'
        -
          macro: '{$UPS.INPUT_VOLT.MIN.WARN}'
          value: '197'
          description: 'Minimum input voltage for trigger expression.'
        -
          macro: '{$UPS.OUTPUT.MAX.WARN}'
          value: '80'
          description: 'Maximum output load in % for trigger expression.'
      dashboards:
        -
          uuid: 268ead40a9dd40798df6d75f554ec1bb
          name: 'UPS Summary'
          pages:
            -
              widgets:
                -
                  type: PLAIN_TEXT
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC Smart-UPS SRT 8000 by SNMP'
                        key: 'system.net.uptime[sysUpTime.0]'
                -
                  type: PLAIN_TEXT
                  x: '8'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC Smart-UPS SRT 8000 by SNMP'
                        key: 'input.fail[upsAdvInputLineFailCause]'
                -
                  type: PLAIN_TEXT
                  x: '16'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC Smart-UPS SRT 8000 by SNMP'
                        key: 'output.status[upsBasicOutputStatus]'
                -
                  type: PLAIN_TEXT
                  'y': '5'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC Smart-UPS SRT 8000 by SNMP'
                        key: 'battery.status[upsBasicBatteryStatus]'
                -
                  type: PLAIN_TEXT
                  x: '8'
                  'y': '5'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC Smart-UPS SRT 8000 by SNMP'
                        key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
                -
                  type: PLAIN_TEXT
                  x: '16'
                  'y': '5'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC Smart-UPS SRT 8000 by SNMP'
                        key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
                -
                  type: GRAPH_CLASSIC
                  'y': '10'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: INTEGER
                      name: source_type
                      value: '0'
                    -
                      type: GRAPH
                      name: graphid
                      value:
                        host: 'APC Smart-UPS SRT 8000 by SNMP'
                        name: 'Capacity of the UPS batteries'
                -
                  type: GRAPH_CLASSIC
                  x: '8'
                  'y': '10'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: INTEGER
                      name: source_type
                      value: '0'
                    -
                      type: GRAPH
                      name: graphid
                      value:
                        host: 'APC Smart-UPS SRT 8000 by SNMP'
                        name: Voltage
                -
                  type: GRAPH_CLASSIC
                  x: '16'
                  'y': '10'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: INTEGER
                      name: source_type
                      value: '0'
                    -
                      type: GRAPH
                      name: graphid
                      value:
                        host: 'APC Smart-UPS SRT 8000 by SNMP'
                        name: Output
      valuemaps:
        -
          uuid: 864d59cbfcc8431cb334b812bf7ef3a3
          name: 'PowerNet-MIB::uioSensorStatusAlarmStatus'
          mappings:
            -
              value: '1'
              newvalue: Normal
            -
              value: '2'
              newvalue: Warning
            -
              value: '3'
              newvalue: Critical
            -
              value: '4'
              newvalue: 'Not applicable'
        -
          uuid: cc42cb7a7fb4417fa1c143e214958c1d
          name: 'PowerNet-MIB::upsAdvBatteryReplaceIndicator'
          mappings:
            -
              value: '1'
              newvalue: 'no Battery Needs Replacing'
            -
              value: '2'
              newvalue: 'battery Needs Replacing'
        -
          uuid: a3bbd0be8c7c4dc1aa9accb9f22292c9
          name: 'PowerNet-MIB::upsAdvInputLineFailCause'
          mappings:
            -
              value: '1'
              newvalue: 'no Transfer'
            -
              value: '2'
              newvalue: 'High Line Voltage'
            -
              value: '3'
              newvalue: Brownout
            -
              value: '4'
              newvalue: Blackout
            -
              value: '5'
              newvalue: 'Small Momentary Sag'
            -
              value: '6'
              newvalue: 'Deep Momentary Sag'
            -
              value: '7'
              newvalue: 'Small Momentary Spike'
            -
              value: '8'
              newvalue: 'Large Momentary Spike'
            -
              value: '9'
              newvalue: 'Self Test'
            -
              value: '10'
              newvalue: 'Rate of Voltage Change'
        -
          uuid: f801d4fb07c644e4be1f01e99ba48aa7
          name: 'PowerNet-MIB::upsBasicBatteryStatus'
          mappings:
            -
              value: '1'
              newvalue: Unknown
            -
              value: '2'
              newvalue: Normal
            -
              value: '3'
              newvalue: Low
            -
              value: '4'
              newvalue: 'In Fault Condition'
        -
          uuid: 28964e9cf2b849fbb2f8d998cecdacda
          name: 'PowerNet-MIB::upsBasicOutputStatus'
          mappings:
            -
              value: '1'
              newvalue: Unknown
            -
              value: '2'
              newvalue: Online
            -
              value: '3'
              newvalue: 'On Battery'
            -
              value: '4'
              newvalue: 'On Smart Boost'
            -
              value: '5'
              newvalue: 'Timed Sleeping'
            -
              value: '6'
              newvalue: 'Software Bypass'
            -
              value: '7'
              newvalue: 'Off'
            -
              value: '8'
              newvalue: Rebooting
            -
              value: '9'
              newvalue: 'Switched Bypass'
            -
              value: '10'
              newvalue: 'Hardware Failure Bypass'
            -
              value: '11'
              newvalue: 'Sleeping Until Power Return'
            -
              value: '12'
              newvalue: 'On Smart Trim'
            -
              value: '13'
              newvalue: 'Eco Mode'
            -
              value: '14'
              newvalue: 'Hot Standby'
            -
              value: '15'
              newvalue: 'On Battery Test'
            -
              value: '16'
              newvalue: 'Emergency Static Bypass'
            -
              value: '17'
              newvalue: 'Static Bypass Standby'
            -
              value: '18'
              newvalue: 'Power Saving Mode'
            -
              value: '19'
              newvalue: 'Spot Mode'
            -
              value: '20'
              newvalue: E-Conversion
            -
              value: '21'
              newvalue: 'Charger Spotmode'
            -
              value: '22'
              newvalue: 'Inverter Spotmode'
            -
              value: '23'
              newvalue: 'Active Load'
            -
              value: '24'
              newvalue: 'Battery Discharge Spotmode'
            -
              value: '25'
              newvalue: 'Inverter Standby'
            -
              value: '26'
              newvalue: 'Charger Only'
        -
          uuid: 12058346f9e046388767c2939bbed2cf
          name: zabbix.host.available
          mappings:
            -
              value: '0'
              newvalue: 'not available'
            -
              value: '1'
              newvalue: available
            -
              value: '2'
              newvalue: unknown
  triggers:
    -
      uuid: 6f0fbe74ad4945e987e7ffdfa741d92f
      expression: '(last(/APC Smart-UPS SRT 8000 by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/APC Smart-UPS SRT 8000 by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/APC Smart-UPS SRT 8000 by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/APC Smart-UPS SRT 8000 by SNMP/system.net.uptime[sysUpTime.0])<10m)'
      name: 'Host has been restarted'
      event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
      priority: WARNING
      description: 'Uptime is less than 10 minutes.'
      manual_close: 'YES'
      dependencies:
        -
          name: 'No SNMP data collection'
          expression: 'max(/APC Smart-UPS SRT 8000 by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
      tags:
        -
          tag: scope
          value: notice
  graphs:
    -
      uuid: e040a4ac7b024c4c878c8145b34969aa
      name: 'Capacity of the UPS batteries'
      type: PIE
      graph_items:
        -
          color: 1A7C11
          item:
            host: 'APC Smart-UPS SRT 8000 by SNMP'
            key: 'battery.capacity[upsHighPrecBatteryCapacity]'
    -
      uuid: 7cd3c6f5dcaf40e28cbc0ac9e3c35d7a
      name: Output
      graph_items:
        -
          color: 1A7C11
          item:
            host: 'APC Smart-UPS SRT 8000 by SNMP'
            key: 'output.current[upsHighPrecOutputCurrent]'
        -
          sortorder: '1'
          color: 2774A4
          item:
            host: 'APC Smart-UPS SRT 8000 by SNMP'
            key: 'output.load[upsHighPrecOutputLoad]'
    -
      uuid: 2fe4eba0af2745c994ad3d6abfe30140
      name: Voltage
      graph_items:
        -
          color: 1A7C11
          item:
            host: 'APC Smart-UPS SRT 8000 by SNMP'
            key: 'input.voltage[upsHighPrecInputLineVoltage]'
        -
          sortorder: '1'
          color: 2774A4
          item:
            host: 'APC Smart-UPS SRT 8000 by SNMP'
            key: 'output.voltage[upsHighPrecOutputVoltage]'