Welcome to mirror list, hosted at ThFree Co, Russian Federation.

template_power_apc_ups_symmetra_lx_snmp.yaml « apc_ups_symmetra_lx_snmp « apc « power « templates - github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
blob: f4967b3fdfc103e3cf43feee829357b725ceb4b0 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
zabbix_export:
  version: '6.4'
  date: '2022-10-27T14:24:42Z'
  template_groups:
    -
      uuid: 3dcd5bbe90534f9e8eb5c2d53756af63
      name: Templates/Power
  templates:
    -
      uuid: 0b9a899ff8f1467c9fdf999d02b9fd77
      template: 'APC UPS Symmetra LX by SNMP'
      name: 'APC UPS Symmetra LX by SNMP'
      description: |
        Template Power APC UPS Symmetra LX
        
        MIBs used:
        HOST-RESOURCES-MIB
        PowerNet-MIB
        SNMPv2-MIB
        
        You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/420730-discussion-thread-for-official-zabbix-template-apc-ups
        
        Template tooling version used: 0.42
      groups:
        -
          name: Templates/Power
      items:
        -
          uuid: 560d838206844447b8f79fd4500557b2
          name: 'Battery capacity'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.1.0
          key: 'battery.capacity[upsHighPrecBatteryCapacity]'
          history: 7d
          value_type: FLOAT
          units: '%'
          description: |
            MIB: PowerNet-MIB
            The remaining battery capacity expressed as
             percentage of full capacity.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
          triggers:
            -
              uuid: fdece80f2fc44ac1974fafe190ce186f
              expression: 'last(/APC UPS Symmetra LX by SNMP/battery.capacity[upsHighPrecBatteryCapacity]) < {$BATTERY.CAPACITY.MIN.WARN}'
              name: 'Battery has low capacity'
              event_name: 'Battery has low capacity (below {$BATTERY.CAPACITY.MIN.WARN}%)'
              opdata: 'Current capacity: {ITEM.LASTVALUE1}'
              priority: HIGH
              tags:
                -
                  tag: scope
                  value: capacity
        -
          uuid: 3fea9d328d5342b5bae6b643a0b45495
          name: 'External battery packs count'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.5.0
          key: 'battery.external_packs_count[upsAdvBatteryNumOfBattPacks]'
          delay: 1h
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The number of external battery packs connected to the UPS. If
             the UPS does not use smart cells then the agent reports
             ERROR_NO_SUCH_NAME.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: inventory
        -
          uuid: f4bd3a4a637640e29f50ebd36fb510e5
          name: 'Battery last replace date'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.1.3.0
          key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
          delay: 1h
          history: 7d
          trends: '0'
          value_type: CHAR
          description: |
            MIB: PowerNet-MIB
            The date when the UPS system's batteries were last replaced
             in mm/dd/yy (or yyyy) format. For Smart-UPS models, this value
             is originally set at the factory. When the UPS batteries
             are replaced, this value should be reset by the administrator.
             For Symmetra PX 250/500 this OID is read-only and is configurable in the local display only.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: inventory
        -
          uuid: 731d350450f742d880d81ff2be69e67e
          name: 'Battery replace indicator'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.4.0
          key: 'battery.replace_indicator[upsAdvBatteryReplaceIndicator]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            Indicates whether the UPS batteries need replacement.
          valuemap:
            name: 'PowerNet-MIB::upsAdvBatteryReplaceIndicator'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
          triggers:
            -
              uuid: a1bd434a249b48b2ac0ef69ede417a72
              expression: 'last(/APC UPS Symmetra LX by SNMP/battery.replace_indicator[upsAdvBatteryReplaceIndicator])=2'
              name: 'Battery needs replacement'
              priority: HIGH
              description: 'A battery installed has an internal error condition.'
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: 8340b775b76f4e8aad6d3984c63632e9
          name: 'Battery runtime remaining'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.3.0
          key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
          history: 7d
          value_type: FLOAT
          units: s
          description: |
            MIB: PowerNet-MIB
            The UPS battery run time remaining before battery
             exhaustion.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.01'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
        -
          uuid: c1d818ee115343c8bb41bedb8de7f2bd
          name: 'Battery status'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.1.1.0
          key: 'battery.status[upsBasicBatteryStatus]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The status of the UPS batteries. A batteryLow(3) value
             indicates the UPS will be unable to sustain the current
             load, and its services will be lost if power is not restored.
             The amount of run time in reserve at the time of low battery
             can be configured by the upsAdvConfigLowBatteryRunTime.
             A batteryInFaultCondition(4)value indicates that a battery
             installed has an internal error condition.
          valuemap:
            name: 'PowerNet-MIB::upsBasicBatteryStatus'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: health
            -
              tag: component
              value: power
          triggers:
            -
              uuid: 955d79a0cf5447dd9a11d4608758e983
              expression: 'last(/APC UPS Symmetra LX by SNMP/battery.status[upsBasicBatteryStatus])=4'
              name: 'Battery has an internal error condition'
              priority: AVERAGE
              description: 'A battery installed has an internal error condition.'
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 3ca8156ecc1c4ee4b5623c4a085b993f
              expression: 'last(/APC UPS Symmetra LX by SNMP/battery.status[upsBasicBatteryStatus])=3'
              name: 'Battery is Low'
              priority: AVERAGE
              description: 'The UPS will be unable to sustain the current load, and its services will be lost if power is not restored.'
              tags:
                -
                  tag: scope
                  value: capacity
        -
          uuid: 6d581eae836342bb8280eb09d7894533
          name: 'Battery temperature'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.2.0
          key: 'battery.temperature[upsHighPrecBatteryTemperature]'
          history: 7d
          value_type: FLOAT
          units: ℃
          description: |
            MIB: PowerNet-MIB
            The current internal UPS temperature in Celsius.
             Temperatures below zero read as 0.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: temperature
          triggers:
            -
              uuid: 5b43659a10644a51861282bc72116f9f
              expression: 'min(/APC UPS Symmetra LX by SNMP/battery.temperature[upsHighPrecBatteryTemperature],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}'
              name: 'Battery has high temperature'
              event_name: 'Battery has high temperature (over {$BATTERY.TEMP.MAX.WARN}℃ for {$TIME.PERIOD})'
              opdata: 'Current temperature: {ITEM.LASTVALUE1}'
              priority: HIGH
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: ab0f5d86a40b421ba136506f7854bbbd
          name: 'Battery voltage'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.3.4.0
          key: 'battery.voltage[upsHighPrecBatteryActualVoltage]'
          history: 7d
          value_type: FLOAT
          units: V
          description: |
            MIB: PowerNet-MIB
            The actual battery bus voltage in Volts.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
        -
          uuid: 13c0d202d19f4b64a52141062c4be6bb
          name: 'Input fail cause'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.2.5.0
          key: 'input.fail[upsAdvInputLineFailCause]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The reason for the occurrence of the last transfer to UPS
            battery power.  The variable is set to:
            - noTransfer(1) -- if there is no transfer yet.
            - highLineVoltage(2) -- if the transfer to battery is caused
            by an over voltage greater than the high transfer voltage.
            - brownout(3) -- if the duration of the outage is greater than
            five seconds and the line voltage is between 40% of the
            rated output voltage and the low transfer voltage.
            - blackout(4) -- if the duration of the outage is greater than five
            seconds and the line voltage is between 40% of the rated
            output voltage and ground.
            - smallMomentarySag(5) -- if the duration of the outage is less
            than five seconds and the line voltage is between 40% of the
            rated output voltage and the low transfer voltage.
            - deepMomentarySag(6) -- if the duration of the outage is less
            than five seconds and the line voltage is between 40% of the
            rated output voltage and ground.  The variable is set to
            - smallMomentarySpike(7) -- if the line failure is caused by a
            rate of change of input voltage less than ten volts per cycle.
            - largeMomentarySpike(8) -- if the line failure is caused by
            a rate of change of input voltage greater than ten volts per cycle.
            - selfTest(9) -- if the UPS was commanded to do a self test.
            - rateOfVoltageChange(10) -- if the failure is due to the rate of change of
            the line voltage.
          valuemap:
            name: 'PowerNet-MIB::upsAdvInputLineFailCause'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
        -
          uuid: 05ccf5bd85414ee9b5860c80f6e8323f
          name: 'Input frequency'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.3.4.0
          key: 'input.frequency[upsHighPrecInputFrequency]'
          history: 7d
          value_type: FLOAT
          units: Hz
          description: |
            MIB: PowerNet-MIB
            The current input frequency to the UPS system in Hz.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
          triggers:
            -
              uuid: 94a5c26b89e2416f96b61bbfc6e60a97
              expression: 'min(/APC UPS Symmetra LX by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > 0 and (min(/APC UPS Symmetra LX by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) > {$UPS.INPUT_FREQ.MAX.WARN} or max(/APC UPS Symmetra LX by SNMP/input.frequency[upsHighPrecInputFrequency],{$TIME.PERIOD}) < {$UPS.INPUT_FREQ.MIN.WARN})'
              name: 'Unacceptable input frequency'
              event_name: 'Unacceptable input frequency (out of range {$UPS.INPUT_FREQ.MIN.WARN}-{$UPS.INPUT_FREQ.MAX.WARN}Hz for {$TIME.PERIOD})'
              opdata: 'Current frequency: {ITEM.LASTVALUE1}'
              priority: HIGH
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: 5764182c547143b3b044ec1adb54c1ce
          name: 'Input voltage'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.3.3.1.0
          key: 'input.voltage[upsHighPrecInputLineVoltage]'
          history: 7d
          value_type: FLOAT
          units: V
          description: |
            MIB: PowerNet-MIB
            The current utility line voltage in VAC.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
          triggers:
            -
              uuid: 2b640b94d48446609802ce6e57c7bd46
              expression: 'min(/APC UPS Symmetra LX by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > 0 and (min(/APC UPS Symmetra LX by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX by SNMP/input.voltage[upsHighPrecInputLineVoltage],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN})'
              name: 'Unacceptable input voltage'
              event_name: 'Unacceptable input voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})'
              opdata: 'Current voltage: {ITEM.LASTVALUE1}'
              priority: HIGH
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: bbb33508be95488680bcb644a44626ef
          name: 'Output current'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.3.4.0
          key: 'output.current[upsHighPrecOutputCurrent]'
          history: 7d
          value_type: FLOAT
          units: A
          description: |
            MIB: PowerNet-MIB
            The current in amperes drawn by the load on the UPS.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
        -
          uuid: d27e991fc0f64b4f9704fb8183567e8d
          name: 'Output load'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.3.3.0
          key: 'output.load[upsHighPrecOutputLoad]'
          history: 7d
          value_type: FLOAT
          units: '%'
          description: |
            MIB: PowerNet-MIB
            The current UPS load expressed as percentage
            of rated capacity.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
          triggers:
            -
              uuid: 34562b5c734d492c89c386902dfd6e90
              expression: 'min(/APC UPS Symmetra LX by SNMP/output.load[upsHighPrecOutputLoad],{$TIME.PERIOD}) > {$UPS.OUTPUT.MAX.WARN}'
              name: 'Output load is high'
              event_name: 'Output load is high (over {$UPS.OUTPUT.MAX.WARN}% for {$TIME.PERIOD})'
              opdata: 'Current load: {ITEM.LASTVALUE1}'
              priority: HIGH
              description: 'A battery installed has an internal error condition.'
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: 978a7ee6923c40cd8097afb60c81244f
          name: 'Output status'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.1.1.0
          key: 'output.status[upsBasicOutputStatus]'
          history: 7d
          description: |
            MIB: PowerNet-MIB
            The current state of the UPS. If the UPS is unable to
             determine the state of the UPS this variable is set
             to unknown(1).
            During self-test most UPSes report onBattery(3) but
             some that support it will report onBatteryTest(15).
             To determine self-test status across all UPSes, refer
             to the upsBasicStateOutputState OID.
          valuemap:
            name: 'PowerNet-MIB::upsBasicOutputStatus'
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: health
            -
              tag: component
              value: power
          triggers:
            -
              uuid: 6ade2b9fb9ad432596d16b3df6237ec4
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=16'
              name: 'UPS is Emergency Static Bypass'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: da9a0fa7669e454b8ba44c0458a94ea8
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=10'
              name: 'UPS is Hardware Failure Bypass'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 01a2bcb5f20b4fe889a48e4bed2a2a63
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=7'
              name: 'UPS is Off'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: d0b154dd92424af8bb841d91d4e7ddd5
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=3'
              name: 'UPS is on battery'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: afc071d0ccfb4226a3c5ee3058270937
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=4'
              name: 'UPS is on Smart Boost'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 12259f4a961a40b39de12d0202d41c56
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=12'
              name: 'UPS is On Smart Trim'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: ef9d1e4b1ec244f6bcf36d19a9e7c9c7
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=8'
              name: 'UPS is Rebooting'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: c673928e7b764b5db0fa3168edd2cc67
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=11'
              name: 'UPS is Sleeping Until Power Return'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: c9b24aa16e124d8c9cd6cfb188ded816
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=6'
              name: 'UPS is Software Bypass'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: 02904426801d4d42b3f634267f8697e7
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=9'
              name: 'UPS is Switched Bypass'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
            -
              uuid: fa08f8a60c2c4d88a3f9ebf317fcd06e
              expression: 'last(/APC UPS Symmetra LX by SNMP/output.status[upsBasicOutputStatus])=5'
              name: 'UPS is Timed Sleeping'
              priority: AVERAGE
              tags:
                -
                  tag: scope
                  value: notice
        -
          uuid: 9cf495d14fdf4059b6c35e7857d7a18c
          name: 'Output voltage'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.4.3.1.0
          key: 'output.voltage[upsHighPrecOutputVoltage]'
          history: 7d
          value_type: FLOAT
          units: V
          description: |
            MIB: PowerNet-MIB
            The output voltage of the UPS system in VAC.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.1'
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: power
        -
          uuid: 102179b315b548e289df3459bc5860c1
          name: 'SNMP traps (fallback)'
          type: SNMP_TRAP
          key: snmptrap.fallback
          history: 2w
          trends: '0'
          value_type: LOG
          description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items'
          logtimefmt: 'hh:mm:sszyyyy/MM/dd'
          tags:
            -
              tag: component
              value: network
        -
          uuid: 8dd800fbbcde431aa421eeb5a33eb798
          name: 'System contact details'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.4.0
          key: 'system.contact[sysContact.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The textual identification of the contact person for this managed
            node, together with information on how to contact this person.  If no contact
            information is known, the value is the zero-length string.
          inventory_link: CONTACT
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 12h
          tags:
            -
              tag: component
              value: system
        -
          uuid: e8c576f27f4c49ef9acd1ba7198ffbb6
          name: 'System description'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.1.0
          key: 'system.descr[sysDescr.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            A textual description of the entity. This value should
            include the full name and version identification of the system's hardware type, software operating-system, and
            networking software.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 12h
          tags:
            -
              tag: component
              value: system
        -
          uuid: e5a92d45430b4bd6bdef42870141d141
          name: 'Uptime (hardware)'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.25.1.1.0
          key: 'system.hw.uptime[hrSystemUptime.0]'
          delay: 30s
          history: 2w
          trends: 0d
          units: uptime
          description: |
            MIB: HOST-RESOURCES-MIB
            The amount of time since this host was last initialized.
            Note that this is different from sysUpTime in the SNMPv2-MIB
            [RFC1907] because sysUpTime is the uptime of the
            network management portion of the system.
          preprocessing:
            -
              type: CHECK_NOT_SUPPORTED
              parameters:
                - ''
              error_handler: CUSTOM_VALUE
              error_handler_params: '0'
            -
              type: MULTIPLIER
              parameters:
                - '0.01'
          tags:
            -
              tag: component
              value: system
        -
          uuid: 6a06715ef4c44534a0ebc45f4e5adb5b
          name: 'System location'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.6.0
          key: 'system.location[sysLocation.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The physical location of this node (e.g., `telephone closet,
            3rd floor').  If the location is unknown, the value is the zero-length string.
          inventory_link: LOCATION
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: system
        -
          uuid: 64d56d199021432886452fff5a4c6d22
          name: Model
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.1.1.1.0
          key: 'system.model[upsBasicIdentModel]'
          delay: 15m
          history: 7d
          trends: '0'
          value_type: CHAR
          description: |
            MIB: PowerNet-MIB
            The UPS model name (e.g. 'APC Smart-UPS 600').
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: inventory
        -
          uuid: b15628c68d4c4e8ca761ad9fa7e40a1c
          name: 'System name'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.5.0
          key: 'system.name[sysName.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            An administratively-assigned name for this managed node.By
            convention, this is the node's fully-qualified domain name.  If the name is unknown,
            the value is the zero-length string.
          inventory_link: NAME
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: system
          triggers:
            -
              uuid: 61d0836efd33437894e1edd595373f1e
              expression: 'last(/APC UPS Symmetra LX by SNMP/system.name[sysName.0],#1)<>last(/APC UPS Symmetra LX by SNMP/system.name[sysName.0],#2) and length(last(/APC UPS Symmetra LX by SNMP/system.name[sysName.0]))>0'
              name: 'System name has changed'
              event_name: 'System name has changed (new name: {ITEM.VALUE})'
              priority: INFO
              description: 'System name has changed. Ack to close.'
              manual_close: 'YES'
              tags:
                -
                  tag: scope
                  value: notice
                -
                  tag: scope
                  value: security
        -
          uuid: 0810681a8ae74ad8b28ea38119a93f59
          name: 'Uptime (network)'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.3.0
          key: 'system.net.uptime[sysUpTime.0]'
          delay: 30s
          history: 2w
          trends: 0d
          units: uptime
          description: |
            MIB: SNMPv2-MIB
            The time (in hundredths of a second) since the network management
            portion of the system was last re-initialized.
          preprocessing:
            -
              type: MULTIPLIER
              parameters:
                - '0.01'
          tags:
            -
              tag: component
              value: system
        -
          uuid: 9f858f7eaed545b8a35ac24e858b0826
          name: 'System object ID'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.2.1.1.2.0
          key: 'system.objectid[sysObjectID.0]'
          delay: 15m
          history: 2w
          trends: '0'
          value_type: CHAR
          description: |
            MIB: SNMPv2-MIB
            The vendor's authoritative identification of the network management
            subsystem contained in the entity.  This value is allocated within the SMI enterprises
            subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what
            kind of box' is being managed.  For example, if vendor`Flintstones, Inc.' was
            assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1
            to its `Fred Router'.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: system
        -
          uuid: 3f61bd561e7d42fbb55b71df9ea3b5b1
          name: 'Serial number'
          type: SNMP_AGENT
          snmp_oid: 1.3.6.1.4.1.318.1.1.1.1.2.3.0
          key: 'system.sn[upsAdvIdentSerialNumber]'
          delay: 15m
          history: 7d
          trends: '0'
          value_type: CHAR
          description: |
            MIB: PowerNet-MIB
            An 8-character string identifying the serial number of
             the UPS internal microprocessor.  This number is set at
             the factory.  NOTE: This number does NOT correspond to
             the serial number on the rear of the UPS.
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: inventory
        -
          uuid: 9562f60b1cbd4fe08614221e69efd811
          name: 'SNMP agent availability'
          type: INTERNAL
          key: 'zabbix[host,snmp,available]'
          history: 7d
          description: |
            Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
            Possible value:
            0 - not available
            1 - available
            2 - unknown
          valuemap:
            name: zabbix.host.available
          preprocessing:
            -
              type: DISCARD_UNCHANGED_HEARTBEAT
              parameters:
                - 6h
          tags:
            -
              tag: component
              value: health
            -
              tag: component
              value: network
          triggers:
            -
              uuid: aeaaa7e2bd2d46a481f9d8b33ec18cb5
              expression: 'max(/APC UPS Symmetra LX by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
              name: 'No SNMP data collection'
              opdata: 'Current state: {ITEM.LASTVALUE1}'
              priority: WARNING
              description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
              tags:
                -
                  tag: scope
                  value: availability
      discovery_rules:
        -
          uuid: 35a885d8f181416db86f2ffe73a30f7f
          name: 'External bad battery packs discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#EXTERNAL_PACKS},1.3.6.1.4.1.318.1.1.1.2.2.6]'
          key: battery.packs.bad.discovery
          delay: 1h
          description: 'Discovery of the number of external defective battery packs.'
          item_prototypes:
            -
              uuid: b0b3bb219c534b40ad07f89ac8c43797
              name: '{#SNMPINDEX}: External battery packs bad'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.1.2.2.6.0
              key: 'battery.external_packs_bad[upsAdvBatteryNumOfBadBattPacks.{#SNMPINDEX}]'
              delay: 15m
              history: 7d
              description: |
                MIB: PowerNet-MIB
                The number of external battery packs connected to the UPS that
                are defective. If the UPS does not use smart cells then the
                agent reports ERROR_NO_SUCH_NAME.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: inventory
        -
          uuid: 168bfbfc58ca46509caf54ae3562f0bc
          name: 'External battery packs discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#CARTRIDGE_STATUS},1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.7,{#BATTERY_PACK},1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.1,{#CARTRIDGE_INDEX},1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.2]'
          key: battery.packs.discovery
          delay: 1h
          filter:
            evaltype: AND
            conditions:
              -
                macro: '{#CARTRIDGE_STATUS}'
                value: ^$
                operator: NOT_MATCHES_REGEX
                formulaid: A
          item_prototypes:
            -
              uuid: 3d2e62971cfb4b0a92b51ece740e1a58
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery estimated replace date'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.8.{#SNMPINDEX}'
              key: 'battery.estimated_replace_date[upsHighPrecBatteryPackCartridgeReplaceDate.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              delay: 1h
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery cartridge estimated battery replace date.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: inventory
                -
                  tag: component
                  value: power
            -
              uuid: b49b4836472f45e3b4947048dcd64cf8
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery pack cartridge health'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.7.{#SNMPINDEX}'
              key: 'battery.pack.cartridge_health[upsHighPrecBatteryPackCartridgeHealth.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery cartridge health.
                  bit 0 Battery lifetime okay
                  bit 1 Battery lifetime near end, order replacement cartridge
                  bit 2 Battery lifetime exceeded, replace battery
                  bit 3 Battery lifetime near end acknowledged, order replacement cartridge
                  bit 4 Battery lifetime exceeded acknowledged, replace battery
                  bit 5 Battery measured lifetime near end, order replacement cartridge
                  bit 6 Battery measured lifetime near end acknowledged, order replacement cartridge
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: health
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 2ea1a8d2bd3746dabafed72e1f6216fd
                  expression: 'find(/APC UPS Symmetra LX by SNMP/battery.pack.cartridge_health[upsHighPrecBatteryPackCartridgeHealth.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0)[0|1]{15}$")=1'
                  name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery lifetime is not okay'
                  opdata: 'Current bit set: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: |
                    The battery cartridge health.
                      bit 0 Battery lifetime okay
                      bit 1 Battery lifetime near end, order replacement cartridge
                      bit 2 Battery lifetime exceeded, replace battery
                      bit 3 Battery lifetime near end acknowledged, order replacement cartridge
                      bit 4 Battery lifetime exceeded acknowledged, replace battery
                      bit 5 Battery measured lifetime near end, order replacement cartridge
                      bit 6 Battery measured lifetime near end acknowledged, order replacement cartridge
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: df73a5fd0d964c67857178a936c2dc7d
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery status'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.10.{#SNMPINDEX}'
              key: 'battery.pack.status[upsHighPrecBatteryPackCartridgeStatus.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery cartridge status.
                bit 0 Disconnected
                bit 1 Overvoltage
                bit 2 NeedsReplacement
                bit 3 OvertemperatureCritical
                bit 4 Charger
                bit 5 TemperatureSensor
                bit 6 BusSoftStart
                bit 7 OvertemperatureWarning
                bit 8 GeneralError
                bit 9 Communication
                bit 10 DisconnectedFrame
                bit 11 FirmwareMismatch
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: health
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 3870634ad8c1414dabeebc10c510fba3
                  expression: 'find(/APC UPS Symmetra LX by SNMP/battery.pack.status[upsHighPrecBatteryPackCartridgeStatus.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],,"regexp","^(0{16})$")=0'
                  name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery status is not okay'
                  opdata: 'Current bit set: {ITEM.LASTVALUE1}'
                  priority: WARNING
                  description: |
                    The battery cartridge status:
                    bit 0 Disconnected
                    bit 1 Overvoltage
                    bit 2 NeedsReplacement
                    bit 3 OvertemperatureCritical
                    bit 4 Charger
                    bit 5 TemperatureSensor
                    bit 6 BusSoftStart
                    bit 7 OvertemperatureWarning
                    bit 8 GeneralError
                    bit 9 Communication
                    bit 10 DisconnectedFrame
                    bit 11 FirmwareMismatch
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: 18c46e7d50ee4eefb669705d62e2224c
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery temperature'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.5.{#SNMPINDEX}'
              key: 'battery.temperature[upsHighPrecBatteryPackTemperature.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              history: 7d
              value_type: FLOAT
              units: ℃
              description: |
                MIB: PowerNet-MIB
                The battery pack temperature in Celsius.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.1'
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: temperature
              trigger_prototypes:
                -
                  uuid: 730bdb68d90f4bc6aaf6cb22e04e1845
                  expression: 'min(/APC UPS Symmetra LX by SNMP/battery.temperature[upsHighPrecBatteryPackTemperature.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}],{$TIME.PERIOD}) > {$BATTERY.TEMP.MAX.WARN}'
                  name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery has high temperature'
                  event_name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Battery has high temperature (over {$BATTERY.TEMP.MAX.WARN}℃ for {$TIME.PERIOD})'
                  opdata: 'Current temperature: {ITEM.LASTVALUE1}'
                  priority: HIGH
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: 5fadf217f7444f58ba3dca52bc6cff76
              name: '{#BATTERY_PACK}.{#CARTRIDGE_INDEX}: Serial number'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.4.{#SNMPINDEX}'
              key: 'system.sn[upsHighPrecBatteryPackSerialNumber.{#BATTERY_PACK}.{#CARTRIDGE_INDEX}]'
              delay: 15m
              history: 7d
              trends: '0'
              value_type: CHAR
              description: |
                MIB: PowerNet-MIB
                The battery pack serial number.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: inventory
        -
          uuid: 598521a7c59d425d9deb58c9829e344e
          name: 'External sensor port 1 discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#EXTERNAL_SENSOR1_NAME},1.3.6.1.4.1.318.1.1.25.1.2.1.3]'
          key: external.sensor1.discovery
          delay: 1h
          description: uioSensorStatusTable
          item_prototypes:
            -
              uuid: 2db30af657574f8f9390002f94b7e249
              name: '{#EXTERNAL_SENSOR1_NAME}: Humidity sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.1.7.1.1
              key: 'external.sensor.humidity[uioSensorStatusHumidity.1.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: PowerNet-MIB
                The sensor's current humidity reading - a relative humidity
                 percentage. -1 indicates an invalid reading due to either a
                 sensor that doesn't read humidity or lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: humidity
                -
                  tag: component
                  value: power
            -
              uuid: 6182750c55f24110b076d95c2cdbd1fa
              name: '{#EXTERNAL_SENSOR1_NAME}: Sensor alarm status'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.1.9.1.1
              key: 'external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}]'
              history: 7d
              description: |
                MIB: PowerNet-MIB
                The alarm status of the sensor. Possible values:
                uioNormal                 (1),
                uioWarning                (2),
                uioCritical               (3),
                sensorStatusNotApplicable (4)
              valuemap:
                name: 'PowerNet-MIB::uioSensorStatusAlarmStatus'
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: health
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 97b4078788d244d0b501e9465c659ff7
                  expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=3'
                  name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Critical'
                  priority: HIGH
                  description: 'The external sensor has returned a value greater than the critical threshold.'
                  tags:
                    -
                      tag: scope
                      value: notice
                -
                  uuid: 86cd9908372045618672d6ff82bca705
                  expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=4'
                  name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Not Applicable'
                  priority: INFO
                  description: 'The external sensor does not work or is not connected.'
                  tags:
                    -
                      tag: scope
                      value: notice
                -
                  uuid: 4ba13efc27da411785410109340b6a26
                  expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.1.{#SNMPINDEX}])=2'
                  name: '{#EXTERNAL_SENSOR1_NAME}: Sensor has status Warning'
                  priority: AVERAGE
                  description: 'The external sensor has returned a value greater than the warning threshold.'
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: fc394520f4964a86ac93e87da2fc541b
              name: '{#EXTERNAL_SENSOR1_NAME}: Temperature sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.1.6.1.1
              key: 'external.sensor.temperature[uioSensorStatusTemperatureDegC.1.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: ℃
              description: |
                MIB: PowerNet-MIB
                The sensor's current temperature reading in Celsius.
                 -1 indicates an invalid reading due to lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
                -
                  tag: component
                  value: temperature
          overrides:
            -
              name: Temp
              step: '1'
              filter:
                conditions:
                  -
                    macro: '{#EXTERNAL_SENSOR1_NAME}'
                    value: Temp
                    formulaid: A
              operations:
                -
                  operationobject: ITEM_PROTOTYPE
                  operator: LIKE
                  value: Humidity
                  discover: NO_DISCOVER
        -
          uuid: 14e6acae826e4e87b68c04beee67a5cb
          name: 'External sensor port 2 discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#EXTERNAL_SENSOR2_NAME},1.3.6.1.4.1.318.1.1.25.1.2.2.3]'
          key: external.sensor2.discovery
          delay: 1h
          description: uioSensorStatusTable
          item_prototypes:
            -
              uuid: 5f5df15d6cc4455083f9fa6932d86656
              name: '{#EXTERNAL_SENSOR2_NAME}: Humidity sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.2.7.1.1
              key: 'external.sensor.humidity[uioSensorStatusHumidity.2.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: PowerNet-MIB
                The sensor's current humidity reading - a relative humidity
                 percentage. -1 indicates an invalid reading due to either a
                 sensor that doesn't read humidity or lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: humidity
                -
                  tag: component
                  value: power
            -
              uuid: ecc2e5c49b004027bb9ccd5498e3d169
              name: '{#EXTERNAL_SENSOR2_NAME}: Sensor alarm status'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.2.9.1.1
              key: 'external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}]'
              history: 7d
              description: |
                MIB: PowerNet-MIB
                The alarm status of the sensor. Possible values:
                uioNormal                 (1),
                uioWarning                (2),
                uioCritical               (3),
                sensorStatusNotApplicable (4)
              valuemap:
                name: 'PowerNet-MIB::uioSensorStatusAlarmStatus'
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: health
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 3155c8cf446c40d896755a25a46ec90b
                  expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=3'
                  name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Critical'
                  priority: HIGH
                  description: 'The external sensor has returned a value greater than the critical threshold.'
                  tags:
                    -
                      tag: scope
                      value: notice
                -
                  uuid: 9ef9a4dc80c84087b44b5f0e8aa94202
                  expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=4'
                  name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Not Applicable'
                  priority: INFO
                  description: 'The external sensor does not work or is not connected.'
                  tags:
                    -
                      tag: scope
                      value: notice
                -
                  uuid: 74a3585b0cc74a4887eb3683fb1e6f64
                  expression: 'last(/APC UPS Symmetra LX by SNMP/external.sensor.status[uioSensorStatusAlarmStatus.2.{#SNMPINDEX}])=2'
                  name: '{#EXTERNAL_SENSOR2_NAME}: Sensor has status Warning'
                  priority: AVERAGE
                  description: 'The external sensor has returned a value greater than the warning threshold.'
                  tags:
                    -
                      tag: scope
                      value: notice
            -
              uuid: f2cd5bb0c8a64b09868ddff9b14e4cbd
              name: '{#EXTERNAL_SENSOR2_NAME}: Temperature sensor'
              type: SNMP_AGENT
              snmp_oid: 1.3.6.1.4.1.318.1.1.25.1.2.2.6.1.1
              key: 'external.sensor.temperature[uioSensorStatusTemperatureDegC.2.{#SNMPINDEX}]'
              history: 7d
              value_type: FLOAT
              units: ℃
              description: |
                MIB: PowerNet-MIB
                The sensor's current temperature reading in Celsius.
                 -1 indicates an invalid reading due to lost communications.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
                -
                  tag: component
                  value: temperature
          overrides:
            -
              name: Temp
              step: '1'
              filter:
                conditions:
                  -
                    macro: '{#EXTERNAL_SENSOR2_NAME}'
                    value: Temp
                    formulaid: A
              operations:
                -
                  operationobject: ITEM_PROTOTYPE
                  operator: LIKE
                  value: Humidity
                  discover: NO_DISCOVER
        -
          uuid: b4f271299e9a47bf8543863a7d9be479
          name: 'Input phases discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#PHASEINDEX},1.3.6.1.4.1.318.1.1.1.9.2.3.1.2.1.1]'
          key: input.phases.discovery
          delay: 1h
          description: 'The input phase identifier. OID upsPhaseInputPhaseIndex.1.1'
          item_prototypes:
            -
              uuid: 161257625bc84427be6cfcd86023c2ec
              name: '{#PHASEINDEX}: Phase input current'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.2.3.1.6.1.1.{#PHASEINDEX}'
              key: 'phase.input.current[upsPhaseInputCurrent.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: A
              description: |
                MIB: PowerNet-MIB
                The input current in 0.1 amperes, or -0.1 if it's
                 unsupported by this UPS.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.1'
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
            -
              uuid: 080719150b424168999c21ff597e6948
              name: '{#PHASEINDEX}: Phase input voltage'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.2.3.1.3.1.1.{#PHASEINDEX}'
              key: 'phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: V
              description: |
                MIB: PowerNet-MIB
                The input voltage in VAC, or -1 if it's unsupported
                 by this UPS.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: 90e3258375e047b594deb0ecf7300c22
                  expression: 'min(/APC UPS Symmetra LX by SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX by SNMP/phase.input.voltage[upsPhaseInputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}'
                  name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage'
                  event_name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} input voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})'
                  opdata: 'Current phase {#PHASEINDEX} voltage: {ITEM.LASTVALUE1}'
                  priority: HIGH
                  tags:
                    -
                      tag: scope
                      value: notice
        -
          uuid: 4232ad35daa3403da085f1ba6c7af348
          name: 'Output phases discovery'
          type: SNMP_AGENT
          snmp_oid: 'discovery[{#PHASEINDEX},1.3.6.1.4.1.318.1.1.1.9.3.3.1.2.1.1]'
          key: output.phases.discovery
          delay: 1h
          description: 'The output phase identifier. OID upsPhaseOutputPhaseIndex.1.1'
          item_prototypes:
            -
              uuid: 2834306ba5464ffaa472c0adddc3d829
              name: '{#PHASEINDEX}: Phase output current'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.3.3.1.4.1.1.{#PHASEINDEX}'
              key: 'phase.output.current[upsPhaseOutputCurrent.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: A
              description: |
                MIB: PowerNet-MIB
                The output current in 0.1 amperes drawn
                 by the load on the UPS, or -1 if it's unsupported
                 by this UPS.
              preprocessing:
                -
                  type: MULTIPLIER
                  parameters:
                    - '0.1'
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
            -
              uuid: 7b0f22672b38492e92c8551c3009baef
              name: '{#PHASEINDEX}: Phase output load, %'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.3.3.1.10.1.1.{#PHASEINDEX}'
              key: 'phase.output.load.percent[upsPhaseOutputPercentLoad.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: '%'
              description: |
                MIB: PowerNet-MIB
                The percentage of the UPS load capacity in VA at
                 redundancy @ (n + x) presently being used on this
                 output phase, or -1 if it's unsupported by this UPS.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
            -
              uuid: a590ab8671574e119fe3335110fdee49
              name: '{#PHASEINDEX}: Phase output voltage'
              type: SNMP_AGENT
              snmp_oid: '1.3.6.1.4.1.318.1.1.1.9.3.3.1.3.1.1.{#PHASEINDEX}'
              key: 'phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}]'
              history: 7d
              value_type: FLOAT
              units: V
              description: |
                MIB: PowerNet-MIB
                The output voltage in VAC, or -1 if it's unsupported
                 by this UPS.
              preprocessing:
                -
                  type: DISCARD_UNCHANGED_HEARTBEAT
                  parameters:
                    - 6h
              tags:
                -
                  tag: component
                  value: power
              trigger_prototypes:
                -
                  uuid: b8c42d5d66d9403eba697920439ae956
                  expression: 'min(/APC UPS Symmetra LX by SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) > {$UPS.INPUT_VOLT.MAX.WARN} or max(/APC UPS Symmetra LX by SNMP/phase.output.voltage[upsPhaseOutputVoltage.1.1.{#PHASEINDEX}],{$TIME.PERIOD}) < {$UPS.INPUT_VOLT.MIN.WARN}'
                  name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage'
                  event_name: '{#PHASEINDEX}: Unacceptable phase {#PHASEINDEX} output voltage (out of range {$UPS.INPUT_VOLT.MIN.WARN}-{$UPS.INPUT_VOLT.MAX.WARN}V for {$TIME.PERIOD})'
                  opdata: 'Current phase {#PHASEINDEX} voltage: {ITEM.LASTVALUE1}'
                  priority: HIGH
                  tags:
                    -
                      tag: scope
                      value: notice
      tags:
        -
          tag: class
          value: power
        -
          tag: target
          value: apc
        -
          tag: target
          value: apc-ups-symmetra-lx
      macros:
        -
          macro: '{$BATTERY.CAPACITY.MIN.WARN}'
          value: '50'
          description: 'Minimum battery capacity percentage for trigger expression.'
        -
          macro: '{$BATTERY.TEMP.MAX.WARN}'
          value: '55'
          description: 'Maximum battery temperature for trigger expression.'
        -
          macro: '{$SNMP.TIMEOUT}'
          value: 5m
          description: 'The time interval for SNMP agent availability trigger expression.'
        -
          macro: '{$TIME.PERIOD}'
          value: 15m
          description: 'Time period for trigger expression.'
        -
          macro: '{$UPS.INPUT_FREQ.MAX.WARN}'
          value: '50.3'
          description: 'Maximum input frequency for trigger expression.'
        -
          macro: '{$UPS.INPUT_FREQ.MIN.WARN}'
          value: '49.7'
          description: 'Minimum input frequency for trigger expression.'
        -
          macro: '{$UPS.INPUT_VOLT.MAX.WARN}'
          value: '243'
          description: 'Maximum input voltage for trigger expression.'
        -
          macro: '{$UPS.INPUT_VOLT.MIN.WARN}'
          value: '197'
          description: 'Minimum input voltage for trigger expression.'
        -
          macro: '{$UPS.OUTPUT.MAX.WARN}'
          value: '80'
          description: 'Maximum output load in % for trigger expression.'
      dashboards:
        -
          uuid: fbf5cb79251d48bdbe4bc7b81dbd2d65
          name: 'UPS Summary'
          pages:
            -
              widgets:
                -
                  type: PLAIN_TEXT
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC UPS Symmetra LX by SNMP'
                        key: 'system.net.uptime[sysUpTime.0]'
                -
                  type: PLAIN_TEXT
                  x: '8'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC UPS Symmetra LX by SNMP'
                        key: 'input.fail[upsAdvInputLineFailCause]'
                -
                  type: PLAIN_TEXT
                  x: '16'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC UPS Symmetra LX by SNMP'
                        key: 'output.status[upsBasicOutputStatus]'
                -
                  type: PLAIN_TEXT
                  'y': '5'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC UPS Symmetra LX by SNMP'
                        key: 'battery.status[upsBasicBatteryStatus]'
                -
                  type: PLAIN_TEXT
                  x: '8'
                  'y': '5'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC UPS Symmetra LX by SNMP'
                        key: 'battery.runtime_remaining[upsAdvBatteryRunTimeRemaining]'
                -
                  type: PLAIN_TEXT
                  x: '16'
                  'y': '5'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: ITEM
                      name: itemids
                      value:
                        host: 'APC UPS Symmetra LX by SNMP'
                        key: 'battery.last_replace_date[upsBasicBatteryLastReplaceDate]'
                -
                  type: GRAPH_CLASSIC
                  'y': '10'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: INTEGER
                      name: source_type
                      value: '0'
                    -
                      type: GRAPH
                      name: graphid
                      value:
                        host: 'APC UPS Symmetra LX by SNMP'
                        name: 'Capacity of the UPS batteries'
                -
                  type: GRAPH_CLASSIC
                  x: '8'
                  'y': '10'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: INTEGER
                      name: source_type
                      value: '0'
                    -
                      type: GRAPH
                      name: graphid
                      value:
                        host: 'APC UPS Symmetra LX by SNMP'
                        name: Voltage
                -
                  type: GRAPH_CLASSIC
                  x: '16'
                  'y': '10'
                  width: '8'
                  height: '5'
                  fields:
                    -
                      type: INTEGER
                      name: source_type
                      value: '0'
                    -
                      type: GRAPH
                      name: graphid
                      value:
                        host: 'APC UPS Symmetra LX by SNMP'
                        name: Output
      valuemaps:
        -
          uuid: aec3362485c242ec928cb8ecfe5e61cf
          name: 'PowerNet-MIB::uioSensorStatusAlarmStatus'
          mappings:
            -
              value: '1'
              newvalue: Normal
            -
              value: '2'
              newvalue: Warning
            -
              value: '3'
              newvalue: Critical
            -
              value: '4'
              newvalue: 'Not applicable'
        -
          uuid: 912d8834176b4fe4a2f6bd12ef3ee3c1
          name: 'PowerNet-MIB::upsAdvBatteryReplaceIndicator'
          mappings:
            -
              value: '1'
              newvalue: 'no Battery Needs Replacing'
            -
              value: '2'
              newvalue: 'battery Needs Replacing'
        -
          uuid: e079fa8cc9614245b0fecf4b8f42feca
          name: 'PowerNet-MIB::upsAdvInputLineFailCause'
          mappings:
            -
              value: '1'
              newvalue: 'no Transfer'
            -
              value: '2'
              newvalue: 'High Line Voltage'
            -
              value: '3'
              newvalue: Brownout
            -
              value: '4'
              newvalue: Blackout
            -
              value: '5'
              newvalue: 'Small Momentary Sag'
            -
              value: '6'
              newvalue: 'Deep Momentary Sag'
            -
              value: '7'
              newvalue: 'Small Momentary Spike'
            -
              value: '8'
              newvalue: 'Large Momentary Spike'
            -
              value: '9'
              newvalue: 'Self Test'
            -
              value: '10'
              newvalue: 'Rate of Voltage Change'
        -
          uuid: 24229472978c42739cdbe7aa47e1d34c
          name: 'PowerNet-MIB::upsBasicBatteryStatus'
          mappings:
            -
              value: '1'
              newvalue: Unknown
            -
              value: '2'
              newvalue: Normal
            -
              value: '3'
              newvalue: Low
            -
              value: '4'
              newvalue: 'In Fault Condition'
        -
          uuid: 8c2c9721615c4408976f7632180ecfe3
          name: 'PowerNet-MIB::upsBasicOutputStatus'
          mappings:
            -
              value: '1'
              newvalue: Unknown
            -
              value: '2'
              newvalue: Online
            -
              value: '3'
              newvalue: 'On Battery'
            -
              value: '4'
              newvalue: 'On Smart Boost'
            -
              value: '5'
              newvalue: 'Timed Sleeping'
            -
              value: '6'
              newvalue: 'Software Bypass'
            -
              value: '7'
              newvalue: 'Off'
            -
              value: '8'
              newvalue: Rebooting
            -
              value: '9'
              newvalue: 'Switched Bypass'
            -
              value: '10'
              newvalue: 'Hardware Failure Bypass'
            -
              value: '11'
              newvalue: 'Sleeping Until Power Return'
            -
              value: '12'
              newvalue: 'On Smart Trim'
            -
              value: '13'
              newvalue: 'Eco Mode'
            -
              value: '14'
              newvalue: 'Hot Standby'
            -
              value: '15'
              newvalue: 'On Battery Test'
            -
              value: '16'
              newvalue: 'Emergency Static Bypass'
            -
              value: '17'
              newvalue: 'Static Bypass Standby'
            -
              value: '18'
              newvalue: 'Power Saving Mode'
            -
              value: '19'
              newvalue: 'Spot Mode'
            -
              value: '20'
              newvalue: E-Conversion
            -
              value: '21'
              newvalue: 'Charger Spotmode'
            -
              value: '22'
              newvalue: 'Inverter Spotmode'
            -
              value: '23'
              newvalue: 'Active Load'
            -
              value: '24'
              newvalue: 'Battery Discharge Spotmode'
            -
              value: '25'
              newvalue: 'Inverter Standby'
            -
              value: '26'
              newvalue: 'Charger Only'
        -
          uuid: 625f28bd49f14e49a1a7a4da01429906
          name: zabbix.host.available
          mappings:
            -
              value: '0'
              newvalue: 'not available'
            -
              value: '1'
              newvalue: available
            -
              value: '2'
              newvalue: unknown
  triggers:
    -
      uuid: 9d0c32f93c0c44f69b54c91fabfa1529
      expression: '(last(/APC UPS Symmetra LX by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/APC UPS Symmetra LX by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/APC UPS Symmetra LX by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/APC UPS Symmetra LX by SNMP/system.net.uptime[sysUpTime.0])<10m)'
      name: 'Host has been restarted'
      event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
      priority: WARNING
      description: 'Uptime is less than 10 minutes.'
      manual_close: 'YES'
      dependencies:
        -
          name: 'No SNMP data collection'
          expression: 'max(/APC UPS Symmetra LX by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
      tags:
        -
          tag: scope
          value: notice
  graphs:
    -
      uuid: 265f3050b3b94cbeae6fefdae02ea992
      name: 'Capacity of the UPS batteries'
      type: PIE
      graph_items:
        -
          color: 1A7C11
          item:
            host: 'APC UPS Symmetra LX by SNMP'
            key: 'battery.capacity[upsHighPrecBatteryCapacity]'
    -
      uuid: 2ef61780d42c4d61bcb89faf08691d08
      name: Output
      graph_items:
        -
          color: 1A7C11
          item:
            host: 'APC UPS Symmetra LX by SNMP'
            key: 'output.current[upsHighPrecOutputCurrent]'
        -
          sortorder: '1'
          color: 2774A4
          item:
            host: 'APC UPS Symmetra LX by SNMP'
            key: 'output.load[upsHighPrecOutputLoad]'
    -
      uuid: 4432ed7ca97d4d989b253383037f48ee
      name: Voltage
      graph_items:
        -
          color: 1A7C11
          item:
            host: 'APC UPS Symmetra LX by SNMP'
            key: 'input.voltage[upsHighPrecInputLineVoltage]'
        -
          sortorder: '1'
          color: 2774A4
          item:
            host: 'APC UPS Symmetra LX by SNMP'
            key: 'output.voltage[upsHighPrecOutputVoltage]'