diff options
Diffstat (limited to 'templates/net/dell_force_s_series_snmp/README.md')
-rw-r--r-- | templates/net/dell_force_s_series_snmp/README.md | 50 |
1 files changed, 25 insertions, 25 deletions
diff --git a/templates/net/dell_force_s_series_snmp/README.md b/templates/net/dell_force_s_series_snmp/README.md index 0585835a2ff..714c8353aae 100644 --- a/templates/net/dell_force_s_series_snmp/README.md +++ b/templates/net/dell_force_s_series_snmp/README.md @@ -1,9 +1,9 @@ -# Dell Force S-Series SNMP +# Dell Force S-Series by SNMP ## Overview -For Zabbix version: 6.4 and higher +For Zabbix version: 6.4 and higher. ## Setup @@ -100,30 +100,30 @@ There are no template links in this template. |Name|Description|Expression|Severity|Dependencies and additional info| |----|-----------|----|----|----| -|#{#SNMPINDEX}: High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/Dell Force S-Series SNMP/system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}` |WARNING | | -|Fan {#SNMPVALUE}: Fan is in critical state |<p>Please check the fan unit</p> |`count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1` |AVERAGE | | -|Fan {#SNMPVALUE}: Fan is not in normal state |<p>Please check the fan unit</p> |`count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1` |INFO |<p>**Depends on**:</p><p>- Fan {#SNMPVALUE}: Fan is in critical state</p> | -|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/Dell Force S-Series SNMP/system.name,#1)<>last(/Dell Force S-Series SNMP/system.name,#2) and length(last(/Dell Force S-Series SNMP/system.name))>0` |INFO |<p>Manual close: YES</p> | -|#{#SNMPVALUE}: Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> | -|#{#SNMPVALUE}: Operating system description has changed |<p>Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.</p> |`last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- System name has changed</p> | -|#{#SNMPINDEX}: High memory utilization |<p>The system is running out of free memory.</p> |`min(/Dell Force S-Series SNMP/vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | | -|Interface {#IFNAME}({#IFALIAS}): In half-duplex mode |<p>Please check autonegotiation settings and cabling</p> |`last(/Dell Force S-Series SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2` |WARNING |<p>Manual close: YES</p> | -|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p><p>3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))`<p>Recovery expression:</p>`last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0` |AVERAGE |<p>Manual close: YES</p> | -|Interface {#IFNAME}({#IFALIAS}): High bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/Dell Force S-Series SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Dell Force S-Series SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0`<p>Recovery expression:</p>`avg(/Dell Force S-Series SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/Dell Force S-Series SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> | -|Interface {#IFNAME}({#IFALIAS}): High error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/Dell Force S-Series SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Dell Force S-Series SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/Dell Force S-Series SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/Dell Force S-Series SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> | -|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`<p>Recovery expression:</p>`(change(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> | -|PSU {#SNMPVALUE}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1` |AVERAGE | | -|PSU {#SNMPVALUE}: Power supply is not in normal state |<p>Please check the power supply unit for errors</p> |`count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1` |INFO |<p>**Depends on**:</p><p>- PSU {#SNMPVALUE}: Power supply is in critical state</p> | -|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Dell Force S-Series SNMP/system.net.uptime[sysUpTime.0])<10m)` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | -|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/Dell Force S-Series SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> | -|Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/Dell Force S-Series SNMP/icmpping,#3)=0` |HIGH | | -|High ICMP ping loss |<p>-</p> |`min(/Dell Force S-Series SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> | -|High ICMP ping response time |<p>-</p> |`avg(/Dell Force S-Series SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> | -|Device {#SNMPVALUE}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3` |WARNING |<p>**Depends on**:</p><p>- Device {#SNMPVALUE}: Temperature is above critical threshold</p> | -|Device {#SNMPVALUE}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3` |HIGH | | -|Device {#SNMPVALUE}: Temperature is too low |<p>-</p> |`avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`min(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3` |AVERAGE | | +|#{#SNMPINDEX}: High CPU utilization |<p>CPU utilization is too high. The system might be slow to respond.</p> |`min(/Dell Force S-Series by SNMP/system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}` |WARNING | | +|Fan {#SNMPVALUE}: Fan is in critical state |<p>Please check the fan unit</p> |`count(/Dell Force S-Series by SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1` |AVERAGE | | +|Fan {#SNMPVALUE}: Fan is not in normal state |<p>Please check the fan unit</p> |`count(/Dell Force S-Series by SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1` |INFO |<p>**Depends on**:</p><p>- Fan {#SNMPVALUE}: Fan is in critical state</p> | +|System name has changed |<p>System name has changed. Ack to close.</p> |`last(/Dell Force S-Series by SNMP/system.name,#1)<>last(/Dell Force S-Series by SNMP/system.name,#2) and length(last(/Dell Force S-Series by SNMP/system.name))>0` |INFO |<p>Manual close: YES</p> | +|#{#SNMPVALUE}: Device has been replaced |<p>Device serial number has changed. Ack to close</p> |`last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p> | +|#{#SNMPVALUE}: Operating system description has changed |<p>Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.</p> |`last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]))>0` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- System name has changed</p> | +|#{#SNMPINDEX}: High memory utilization |<p>The system is running out of free memory.</p> |`min(/Dell Force S-Series by SNMP/vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}` |AVERAGE | | +|Interface {#IFNAME}({#IFALIAS}): In half-duplex mode |<p>Please check autonegotiation settings and cabling</p> |`last(/Dell Force S-Series by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2` |WARNING |<p>Manual close: YES</p> | +|Interface {#IFNAME}({#IFALIAS}): Link down |<p>This trigger expression works as follows:</p><p>1. Can be triggered if operations status is down.</p><p>2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.</p><p>3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.)</p><p>WARNING: if closed manually - won't fire again on next poll, because of .diff.</p> |`{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))`<p>Recovery expression:</p>`last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0` |AVERAGE |<p>Manual close: YES</p> | +|Interface {#IFNAME}({#IFALIAS}): High bandwidth usage |<p>The network interface utilization is close to its estimated maximum bandwidth.</p> |`(avg(/Dell Force S-Series by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Dell Force S-Series by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0`<p>Recovery expression:</p>`avg(/Dell Force S-Series by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/Dell Force S-Series by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> | +|Interface {#IFNAME}({#IFALIAS}): High error rate |<p>Recovers when below 80% of {$IF.ERRORS.WARN:"{#IFNAME}"} threshold</p> |`min(/Dell Force S-Series by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Dell Force S-Series by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`<p>Recovery expression:</p>`max(/Dell Force S-Series by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/Dell Force S-Series by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> | +|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before |<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Ack to close.</p> |`change(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`<p>Recovery expression:</p>`(change(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)` |INFO |<p>Manual close: YES</p><p>**Depends on**:</p><p>- Interface {#IFNAME}({#IFALIAS}): Link down</p> | +|PSU {#SNMPVALUE}: Power supply is in critical state |<p>Please check the power supply unit for errors</p> |`count(/Dell Force S-Series by SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1` |AVERAGE | | +|PSU {#SNMPVALUE}: Power supply is not in normal state |<p>Please check the power supply unit for errors</p> |`count(/Dell Force S-Series by SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1` |INFO |<p>**Depends on**:</p><p>- PSU {#SNMPVALUE}: Power supply is in critical state</p> | +|Host has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Dell Force S-Series by SNMP/system.net.uptime[sysUpTime.0])<10m)` |WARNING |<p>Manual close: YES</p><p>**Depends on**:</p><p>- No SNMP data collection</p> | +|No SNMP data collection |<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p> |`max(/Dell Force S-Series by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> | +|Unavailable by ICMP ping |<p>Last three attempts returned timeout. Please check device connectivity.</p> |`max(/Dell Force S-Series by SNMP/icmpping,#3)=0` |HIGH | | +|High ICMP ping loss |<p>-</p> |`min(/Dell Force S-Series by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series by SNMP/icmppingloss,5m)<100` |WARNING |<p>**Depends on**:</p><p>- Unavailable by ICMP ping</p> | +|High ICMP ping response time |<p>-</p> |`avg(/Dell Force S-Series by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}` |WARNING |<p>**Depends on**:</p><p>- High ICMP ping loss</p><p>- Unavailable by ICMP ping</p> | +|Device {#SNMPVALUE}: Temperature is above warning threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3` |WARNING |<p>**Depends on**:</p><p>- Device {#SNMPVALUE}: Temperature is above critical threshold</p> | +|Device {#SNMPVALUE}: Temperature is above critical threshold |<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p> |`avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`max(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3` |HIGH | | +|Device {#SNMPVALUE}: Temperature is too low |<p>-</p> |`avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}`<p>Recovery expression:</p>`min(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3` |AVERAGE | | ## Feedback -Please report any issues with the template at https://support.zabbix.com +Please report any issues with the template at https://support.zabbix.com. |