diff options
Diffstat (limited to 'templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml')
-rw-r--r-- | templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml | 140 |
1 files changed, 70 insertions, 70 deletions
diff --git a/templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml b/templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml index ab1c676c3e4..78420d1e5bd 100644 --- a/templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml +++ b/templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml @@ -1,6 +1,6 @@ zabbix_export: version: '6.4' - date: '2022-08-16T11:05:05Z' + date: '2022-10-27T14:44:02Z' template_groups: - uuid: 36bff6c29af64692839d077febfc7079 @@ -8,8 +8,8 @@ zabbix_export: templates: - uuid: e5ec7acc7efc4ac491b6fa552ab077ae - template: 'Dell Force S-Series SNMP' - name: 'Dell Force S-Series SNMP' + template: 'Dell Force S-Series by SNMP' + name: 'Dell Force S-Series by SNMP' description: | Template Dell Force S-Series @@ -43,7 +43,7 @@ zabbix_export: triggers: - uuid: f186488b337f4b1b8971992e8118d9cc - expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0' + expression: 'max(/Dell Force S-Series by SNMP/icmpping,#3)=0' name: 'Unavailable by ICMP ping' priority: HIGH description: 'Last three attempts returned timeout. Please check device connectivity.' @@ -69,14 +69,14 @@ zabbix_export: triggers: - uuid: 46798adec54c47a38cb599773767a2a7 - expression: 'min(/Dell Force S-Series SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series SNMP/icmppingloss,5m)<100' + expression: 'min(/Dell Force S-Series by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series by SNMP/icmppingloss,5m)<100' name: 'High ICMP ping loss' opdata: 'Loss: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Unavailable by ICMP ping' - expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0' + expression: 'max(/Dell Force S-Series by SNMP/icmpping,#3)=0' tags: - tag: scope @@ -102,17 +102,17 @@ zabbix_export: triggers: - uuid: 04828676081147b4bfad0ad03385986e - expression: 'avg(/Dell Force S-Series SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' + expression: 'avg(/Dell Force S-Series by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' name: 'High ICMP ping response time' opdata: 'Value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'High ICMP ping loss' - expression: 'min(/Dell Force S-Series SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series SNMP/icmppingloss,5m)<100' + expression: 'min(/Dell Force S-Series by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series by SNMP/icmppingloss,5m)<100' - name: 'Unavailable by ICMP ping' - expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0' + expression: 'max(/Dell Force S-Series by SNMP/icmpping,#3)=0' tags: - tag: scope @@ -258,7 +258,7 @@ zabbix_export: triggers: - uuid: 2dc35c5813b042fd96f2ebc53f565799 - expression: 'last(/Dell Force S-Series SNMP/system.name,#1)<>last(/Dell Force S-Series SNMP/system.name,#2) and length(last(/Dell Force S-Series SNMP/system.name))>0' + expression: 'last(/Dell Force S-Series by SNMP/system.name,#1)<>last(/Dell Force S-Series by SNMP/system.name,#2) and length(last(/Dell Force S-Series by SNMP/system.name))>0' name: 'System name has changed' event_name: 'System name has changed (new name: {ITEM.VALUE})' priority: INFO @@ -339,7 +339,7 @@ zabbix_export: triggers: - uuid: da99689aa1394d17af5008e5678915bc - expression: 'max(/Dell Force S-Series SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' + expression: 'max(/Dell Force S-Series by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING @@ -347,7 +347,7 @@ zabbix_export: dependencies: - name: 'Unavailable by ICMP ping' - expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0' + expression: 'max(/Dell Force S-Series by SNMP/icmpping,#3)=0' tags: - tag: scope @@ -382,7 +382,7 @@ zabbix_export: trigger_prototypes: - uuid: aecc6fdd58404347b3074b0c1db63f09 - expression: 'count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1' + expression: 'count(/Dell Force S-Series by SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1' name: 'Fan {#SNMPVALUE}: Fan is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE @@ -396,7 +396,7 @@ zabbix_export: value: performance - uuid: a53271304dcf418aa5afdaa145436b70 - expression: 'count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1' + expression: 'count(/Dell Force S-Series by SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1' name: 'Fan {#SNMPVALUE}: Fan is not in normal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: INFO @@ -404,7 +404,7 @@ zabbix_export: dependencies: - name: 'Fan {#SNMPVALUE}: Fan is in critical state' - expression: 'count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1' + expression: 'count(/Dell Force S-Series by SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1' tags: - tag: scope @@ -436,7 +436,7 @@ zabbix_export: trigger_prototypes: - uuid: 002c0f19cfe54fe08da2183654752470 - expression: 'min(/Dell Force S-Series SNMP/system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}' + expression: 'min(/Dell Force S-Series by SNMP/system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}' name: '#{#SNMPINDEX}: High CPU utilization' event_name: '#{#SNMPINDEX}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)' opdata: 'Current utilization: {ITEM.LASTVALUE1}' @@ -465,7 +465,7 @@ zabbix_export: trigger_prototypes: - uuid: 41baaaa2eb6246b7982ac76928fbd0f8 - expression: 'min(/Dell Force S-Series SNMP/vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}' + expression: 'min(/Dell Force S-Series by SNMP/vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}' name: '#{#SNMPINDEX}: High memory utilization' event_name: '#{#SNMPINDEX}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)' priority: AVERAGE @@ -488,7 +488,7 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Dell Force S-Series SNMP' + host: 'Dell Force S-Series by SNMP' key: 'system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}]' - uuid: 69c63b7fb65347cc9301b02e1f9cd45e @@ -500,7 +500,7 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Dell Force S-Series SNMP' + host: 'Dell Force S-Series by SNMP' key: 'vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}]' - uuid: 620805730ede4c7281a1c736fcfeb130 @@ -806,9 +806,9 @@ zabbix_export: trigger_prototypes: - uuid: b7b55335f42b4ace8434588bc70f7e60 - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' + recovery_expression: 'last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' name: 'Interface {#IFNAME}({#IFALIAS}): Link down' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE @@ -859,21 +859,21 @@ zabbix_export: - uuid: f4903edf173f470482174ee9937cbb32 expression: | - change(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 + change(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( - last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or - last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or - last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or - last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or - last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or - last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 + last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or + last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or + last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or + last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or + last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or + last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and - (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) + (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) recovery_mode: RECOVERY_EXPRESSION recovery_expression: | - (change(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or - (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2) + (change(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or + (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2) name: 'Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before' opdata: 'Current reported speed: {ITEM.LASTVALUE1}' priority: INFO @@ -882,8 +882,8 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' - recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' + recovery_expression: 'last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' tags: - tag: scope @@ -891,13 +891,13 @@ zabbix_export: - uuid: e85a287c2e0e48e19cb43bf74d3f3535 expression: | - (avg(/Dell Force S-Series SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or - avg(/Dell Force S-Series SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and - last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 + (avg(/Dell Force S-Series by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or + avg(/Dell Force S-Series by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and + last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 recovery_mode: RECOVERY_EXPRESSION recovery_expression: | - avg(/Dell Force S-Series SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and - avg(/Dell Force S-Series SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) + avg(/Dell Force S-Series by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and + avg(/Dell Force S-Series by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage' event_name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage (>{$IF.UTIL.MAX:"{#IFNAME}"}%)' opdata: 'In: {ITEM.LASTVALUE1}, out: {ITEM.LASTVALUE3}, speed: {ITEM.LASTVALUE2}' @@ -907,8 +907,8 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' - recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' + recovery_expression: 'last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' tags: - tag: scope @@ -916,12 +916,12 @@ zabbix_export: - uuid: 00d2988bdd084719ba781562920d20fa expression: | - min(/Dell Force S-Series SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} - or min(/Dell Force S-Series SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} + min(/Dell Force S-Series by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} + or min(/Dell Force S-Series by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} recovery_mode: RECOVERY_EXPRESSION recovery_expression: | - max(/Dell Force S-Series SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 - and max(/Dell Force S-Series SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 + max(/Dell Force S-Series by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 + and max(/Dell Force S-Series by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 name: 'Interface {#IFNAME}({#IFALIAS}): High error rate' event_name: 'Interface {#IFNAME}({#IFALIAS}): High error rate (>{$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)' opdata: 'errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}' @@ -931,8 +931,8 @@ zabbix_export: dependencies: - name: 'Interface {#IFNAME}({#IFALIAS}): Link down' - expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' - recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' + expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' + recovery_expression: 'last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' tags: - tag: scope @@ -949,42 +949,42 @@ zabbix_export: drawtype: GRADIENT_LINE color: 1A7C11 item: - host: 'Dell Force S-Series SNMP' + host: 'Dell Force S-Series by SNMP' key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]' - sortorder: '1' drawtype: BOLD_LINE color: 2774A4 item: - host: 'Dell Force S-Series SNMP' + host: 'Dell Force S-Series by SNMP' key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]' - sortorder: '2' color: F63100 yaxisside: RIGHT item: - host: 'Dell Force S-Series SNMP' + host: 'Dell Force S-Series by SNMP' key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]' - sortorder: '3' color: A54F10 yaxisside: RIGHT item: - host: 'Dell Force S-Series SNMP' + host: 'Dell Force S-Series by SNMP' key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]' - sortorder: '4' color: FC6EA3 yaxisside: RIGHT item: - host: 'Dell Force S-Series SNMP' + host: 'Dell Force S-Series by SNMP' key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]' - sortorder: '5' color: 6C59DC yaxisside: RIGHT item: - host: 'Dell Force S-Series SNMP' + host: 'Dell Force S-Series by SNMP' key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]' - uuid: 6782ece35ded46b08a4f45a9743b1ff5 @@ -1054,7 +1054,7 @@ zabbix_export: trigger_prototypes: - uuid: edc143c44b2d465cac94c4cf0fb588a6 - expression: 'last(/Dell Force S-Series SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2' + expression: 'last(/Dell Force S-Series by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2' name: 'Interface {#IFNAME}({#IFALIAS}): In half-duplex mode' priority: WARNING description: 'Please check autonegotiation settings and cabling' @@ -1111,7 +1111,7 @@ zabbix_export: trigger_prototypes: - uuid: 764f08ab7a29481fa73a63ae256ff154 - expression: 'count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1' + expression: 'count(/Dell Force S-Series by SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1' name: 'PSU {#SNMPVALUE}: Power supply is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE @@ -1125,7 +1125,7 @@ zabbix_export: value: performance - uuid: a7d4ac882ec24cce9839c6012c7fa562 - expression: 'count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1' + expression: 'count(/Dell Force S-Series by SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1' name: 'PSU {#SNMPVALUE}: Power supply is not in normal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: INFO @@ -1133,7 +1133,7 @@ zabbix_export: dependencies: - name: 'PSU {#SNMPVALUE}: Power supply is in critical state' - expression: 'count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1' + expression: 'count(/Dell Force S-Series by SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1' tags: - tag: scope @@ -1165,9 +1165,9 @@ zabbix_export: trigger_prototypes: - uuid: dc1064de6a6b4533be812e590b96927b - expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' + expression: 'avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' + recovery_expression: 'max(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' name: 'Device {#SNMPVALUE}: Temperature is above critical threshold' event_name: 'Device {#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -1182,9 +1182,9 @@ zabbix_export: value: performance - uuid: f4d0a2c0b1a9468990e1f6dbfef1ab75 - expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}' + expression: 'avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3' + recovery_expression: 'max(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3' name: 'Device {#SNMPVALUE}: Temperature is above warning threshold' event_name: 'Device {#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -1193,8 +1193,8 @@ zabbix_export: dependencies: - name: 'Device {#SNMPVALUE}: Temperature is above critical threshold' - expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' - recovery_expression: 'max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' + expression: 'avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' + recovery_expression: 'max(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' tags: - tag: scope @@ -1204,9 +1204,9 @@ zabbix_export: value: performance - uuid: f1bbf02af05041ef95ff80ff18fc02a7 - expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}' + expression: 'avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION - recovery_expression: 'min(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3' + recovery_expression: 'min(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3' name: 'Device {#SNMPVALUE}: Temperature is too low' event_name: 'Device {#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' @@ -1265,7 +1265,7 @@ zabbix_export: trigger_prototypes: - uuid: 6f02e903dab24bf294015f43e0b52504 - expression: 'last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]))>0' + expression: 'last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]))>0' name: '#{#SNMPVALUE}: Device has been replaced' event_name: '#{#SNMPVALUE}: Device has been replaced (new serial number received)' priority: INFO @@ -1322,7 +1322,7 @@ zabbix_export: trigger_prototypes: - uuid: 66049aa1d7cb45ebac1fe5292c309ba2 - expression: 'last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]))>0' + expression: 'last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]))>0' name: '#{#SNMPVALUE}: Operating system description has changed' priority: INFO description: 'Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.' @@ -1330,7 +1330,7 @@ zabbix_export: dependencies: - name: 'System name has changed' - expression: 'last(/Dell Force S-Series SNMP/system.name,#1)<>last(/Dell Force S-Series SNMP/system.name,#2) and length(last(/Dell Force S-Series SNMP/system.name))>0' + expression: 'last(/Dell Force S-Series by SNMP/system.name,#1)<>last(/Dell Force S-Series by SNMP/system.name,#2) and length(last(/Dell Force S-Series by SNMP/system.name))>0' tags: - tag: scope @@ -1459,7 +1459,7 @@ zabbix_export: type: GRAPH_PROTOTYPE name: graphid value: - host: 'Dell Force S-Series SNMP' + host: 'Dell Force S-Series by SNMP' name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic' valuemaps: - @@ -2411,7 +2411,7 @@ zabbix_export: triggers: - uuid: 4246a064d33f428c8441491402ae8090 - expression: '(last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Dell Force S-Series SNMP/system.net.uptime[sysUpTime.0])<10m)' + expression: '(last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Dell Force S-Series by SNMP/system.net.uptime[sysUpTime.0])<10m)' name: 'Host has been restarted' event_name: '{HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING @@ -2420,7 +2420,7 @@ zabbix_export: dependencies: - name: 'No SNMP data collection' - expression: 'max(/Dell Force S-Series SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' + expression: 'max(/Dell Force S-Series by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' tags: - tag: scope |