Welcome to mirror list, hosted at ThFree Co, Russian Federation.

github.com/zabbix/zabbix.git - Unnamed repository; edit this file 'description' to name the repository.
summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
Diffstat (limited to 'templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml')
-rw-r--r--templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml140
1 files changed, 70 insertions, 70 deletions
diff --git a/templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml b/templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml
index ab1c676c3e4..78420d1e5bd 100644
--- a/templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml
+++ b/templates/net/dell_force_s_series_snmp/template_net_dell_force_s_series_snmp.yaml
@@ -1,6 +1,6 @@
zabbix_export:
version: '6.4'
- date: '2022-08-16T11:05:05Z'
+ date: '2022-10-27T14:44:02Z'
template_groups:
-
uuid: 36bff6c29af64692839d077febfc7079
@@ -8,8 +8,8 @@ zabbix_export:
templates:
-
uuid: e5ec7acc7efc4ac491b6fa552ab077ae
- template: 'Dell Force S-Series SNMP'
- name: 'Dell Force S-Series SNMP'
+ template: 'Dell Force S-Series by SNMP'
+ name: 'Dell Force S-Series by SNMP'
description: |
Template Dell Force S-Series
@@ -43,7 +43,7 @@ zabbix_export:
triggers:
-
uuid: f186488b337f4b1b8971992e8118d9cc
- expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0'
+ expression: 'max(/Dell Force S-Series by SNMP/icmpping,#3)=0'
name: 'Unavailable by ICMP ping'
priority: HIGH
description: 'Last three attempts returned timeout. Please check device connectivity.'
@@ -69,14 +69,14 @@ zabbix_export:
triggers:
-
uuid: 46798adec54c47a38cb599773767a2a7
- expression: 'min(/Dell Force S-Series SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series SNMP/icmppingloss,5m)<100'
+ expression: 'min(/Dell Force S-Series by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series by SNMP/icmppingloss,5m)<100'
name: 'High ICMP ping loss'
opdata: 'Loss: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'Unavailable by ICMP ping'
- expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0'
+ expression: 'max(/Dell Force S-Series by SNMP/icmpping,#3)=0'
tags:
-
tag: scope
@@ -102,17 +102,17 @@ zabbix_export:
triggers:
-
uuid: 04828676081147b4bfad0ad03385986e
- expression: 'avg(/Dell Force S-Series SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
+ expression: 'avg(/Dell Force S-Series by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
name: 'High ICMP ping response time'
opdata: 'Value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
-
name: 'High ICMP ping loss'
- expression: 'min(/Dell Force S-Series SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series SNMP/icmppingloss,5m)<100'
+ expression: 'min(/Dell Force S-Series by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series by SNMP/icmppingloss,5m)<100'
-
name: 'Unavailable by ICMP ping'
- expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0'
+ expression: 'max(/Dell Force S-Series by SNMP/icmpping,#3)=0'
tags:
-
tag: scope
@@ -258,7 +258,7 @@ zabbix_export:
triggers:
-
uuid: 2dc35c5813b042fd96f2ebc53f565799
- expression: 'last(/Dell Force S-Series SNMP/system.name,#1)<>last(/Dell Force S-Series SNMP/system.name,#2) and length(last(/Dell Force S-Series SNMP/system.name))>0'
+ expression: 'last(/Dell Force S-Series by SNMP/system.name,#1)<>last(/Dell Force S-Series by SNMP/system.name,#2) and length(last(/Dell Force S-Series by SNMP/system.name))>0'
name: 'System name has changed'
event_name: 'System name has changed (new name: {ITEM.VALUE})'
priority: INFO
@@ -339,7 +339,7 @@ zabbix_export:
triggers:
-
uuid: da99689aa1394d17af5008e5678915bc
- expression: 'max(/Dell Force S-Series SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
+ expression: 'max(/Dell Force S-Series by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
name: 'No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
@@ -347,7 +347,7 @@ zabbix_export:
dependencies:
-
name: 'Unavailable by ICMP ping'
- expression: 'max(/Dell Force S-Series SNMP/icmpping,#3)=0'
+ expression: 'max(/Dell Force S-Series by SNMP/icmpping,#3)=0'
tags:
-
tag: scope
@@ -382,7 +382,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: aecc6fdd58404347b3074b0c1db63f09
- expression: 'count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
+ expression: 'count(/Dell Force S-Series by SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
name: 'Fan {#SNMPVALUE}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
@@ -396,7 +396,7 @@ zabbix_export:
value: performance
-
uuid: a53271304dcf418aa5afdaa145436b70
- expression: 'count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1'
+ expression: 'count(/Dell Force S-Series by SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1'
name: 'Fan {#SNMPVALUE}: Fan is not in normal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: INFO
@@ -404,7 +404,7 @@ zabbix_export:
dependencies:
-
name: 'Fan {#SNMPVALUE}: Fan is in critical state'
- expression: 'count(/Dell Force S-Series SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
+ expression: 'count(/Dell Force S-Series by SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
tags:
-
tag: scope
@@ -436,7 +436,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 002c0f19cfe54fe08da2183654752470
- expression: 'min(/Dell Force S-Series SNMP/system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
+ expression: 'min(/Dell Force S-Series by SNMP/system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
name: '#{#SNMPINDEX}: High CPU utilization'
event_name: '#{#SNMPINDEX}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
opdata: 'Current utilization: {ITEM.LASTVALUE1}'
@@ -465,7 +465,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 41baaaa2eb6246b7982ac76928fbd0f8
- expression: 'min(/Dell Force S-Series SNMP/vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
+ expression: 'min(/Dell Force S-Series by SNMP/vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
name: '#{#SNMPINDEX}: High memory utilization'
event_name: '#{#SNMPINDEX}: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
priority: AVERAGE
@@ -488,7 +488,7 @@ zabbix_export:
drawtype: GRADIENT_LINE
color: 1A7C11
item:
- host: 'Dell Force S-Series SNMP'
+ host: 'Dell Force S-Series by SNMP'
key: 'system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}]'
-
uuid: 69c63b7fb65347cc9301b02e1f9cd45e
@@ -500,7 +500,7 @@ zabbix_export:
drawtype: GRADIENT_LINE
color: 1A7C11
item:
- host: 'Dell Force S-Series SNMP'
+ host: 'Dell Force S-Series by SNMP'
key: 'vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}]'
-
uuid: 620805730ede4c7281a1c736fcfeb130
@@ -806,9 +806,9 @@ zabbix_export:
trigger_prototypes:
-
uuid: b7b55335f42b4ace8434588bc70f7e60
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ recovery_expression: 'last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
@@ -859,21 +859,21 @@ zabbix_export:
-
uuid: f4903edf173f470482174ee9937cbb32
expression: |
- change(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
+ change(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
and (
- last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or
- last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or
- last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or
- last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or
- last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or
- last(/Dell Force S-Series SNMP/net.if.type[ifType.{#SNMPINDEX}])=117
+ last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or
+ last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or
+ last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or
+ last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or
+ last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or
+ last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117
)
and
- (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)
+ (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
- (change(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or
- (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)
+ (change(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or
+ (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)
name: 'Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before'
opdata: 'Current reported speed: {ITEM.LASTVALUE1}'
priority: INFO
@@ -882,8 +882,8 @@ zabbix_export:
dependencies:
-
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
- recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ recovery_expression: 'last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
-
tag: scope
@@ -891,13 +891,13 @@ zabbix_export:
-
uuid: e85a287c2e0e48e19cb43bf74d3f3535
expression: |
- (avg(/Dell Force S-Series SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or
- avg(/Dell Force S-Series SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and
- last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
+ (avg(/Dell Force S-Series by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or
+ avg(/Dell Force S-Series by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and
+ last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
- avg(/Dell Force S-Series SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and
- avg(/Dell Force S-Series SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])
+ avg(/Dell Force S-Series by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and
+ avg(/Dell Force S-Series by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])
name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage'
event_name: 'Interface {#IFNAME}({#IFALIAS}): High bandwidth usage (>{$IF.UTIL.MAX:"{#IFNAME}"}%)'
opdata: 'In: {ITEM.LASTVALUE1}, out: {ITEM.LASTVALUE3}, speed: {ITEM.LASTVALUE2}'
@@ -907,8 +907,8 @@ zabbix_export:
dependencies:
-
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
- recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ recovery_expression: 'last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
-
tag: scope
@@ -916,12 +916,12 @@ zabbix_export:
-
uuid: 00d2988bdd084719ba781562920d20fa
expression: |
- min(/Dell Force S-Series SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
- or min(/Dell Force S-Series SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
+ min(/Dell Force S-Series by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
+ or min(/Dell Force S-Series by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
- max(/Dell Force S-Series SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
- and max(/Dell Force S-Series SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
+ max(/Dell Force S-Series by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
+ and max(/Dell Force S-Series by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
name: 'Interface {#IFNAME}({#IFALIAS}): High error rate'
event_name: 'Interface {#IFNAME}({#IFALIAS}): High error rate (>{$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)'
opdata: 'errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}'
@@ -931,8 +931,8 @@ zabbix_export:
dependencies:
-
name: 'Interface {#IFNAME}({#IFALIAS}): Link down'
- expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
- recovery_expression: 'last(/Dell Force S-Series SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
+ expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
+ recovery_expression: 'last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
-
tag: scope
@@ -949,42 +949,42 @@ zabbix_export:
drawtype: GRADIENT_LINE
color: 1A7C11
item:
- host: 'Dell Force S-Series SNMP'
+ host: 'Dell Force S-Series by SNMP'
key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]'
-
sortorder: '1'
drawtype: BOLD_LINE
color: 2774A4
item:
- host: 'Dell Force S-Series SNMP'
+ host: 'Dell Force S-Series by SNMP'
key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]'
-
sortorder: '2'
color: F63100
yaxisside: RIGHT
item:
- host: 'Dell Force S-Series SNMP'
+ host: 'Dell Force S-Series by SNMP'
key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]'
-
sortorder: '3'
color: A54F10
yaxisside: RIGHT
item:
- host: 'Dell Force S-Series SNMP'
+ host: 'Dell Force S-Series by SNMP'
key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]'
-
sortorder: '4'
color: FC6EA3
yaxisside: RIGHT
item:
- host: 'Dell Force S-Series SNMP'
+ host: 'Dell Force S-Series by SNMP'
key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]'
-
sortorder: '5'
color: 6C59DC
yaxisside: RIGHT
item:
- host: 'Dell Force S-Series SNMP'
+ host: 'Dell Force S-Series by SNMP'
key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]'
-
uuid: 6782ece35ded46b08a4f45a9743b1ff5
@@ -1054,7 +1054,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: edc143c44b2d465cac94c4cf0fb588a6
- expression: 'last(/Dell Force S-Series SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2'
+ expression: 'last(/Dell Force S-Series by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2'
name: 'Interface {#IFNAME}({#IFALIAS}): In half-duplex mode'
priority: WARNING
description: 'Please check autonegotiation settings and cabling'
@@ -1111,7 +1111,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 764f08ab7a29481fa73a63ae256ff154
- expression: 'count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
+ expression: 'count(/Dell Force S-Series by SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
name: 'PSU {#SNMPVALUE}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
@@ -1125,7 +1125,7 @@ zabbix_export:
value: performance
-
uuid: a7d4ac882ec24cce9839c6012c7fa562
- expression: 'count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1'
+ expression: 'count(/Dell Force S-Series by SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1'
name: 'PSU {#SNMPVALUE}: Power supply is not in normal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: INFO
@@ -1133,7 +1133,7 @@ zabbix_export:
dependencies:
-
name: 'PSU {#SNMPVALUE}: Power supply is in critical state'
- expression: 'count(/Dell Force S-Series SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
+ expression: 'count(/Dell Force S-Series by SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
tags:
-
tag: scope
@@ -1165,9 +1165,9 @@ zabbix_export:
trigger_prototypes:
-
uuid: dc1064de6a6b4533be812e590b96927b
- expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
+ expression: 'avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
+ recovery_expression: 'max(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
name: 'Device {#SNMPVALUE}: Temperature is above critical threshold'
event_name: 'Device {#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
@@ -1182,9 +1182,9 @@ zabbix_export:
value: performance
-
uuid: f4d0a2c0b1a9468990e1f6dbfef1ab75
- expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}'
+ expression: 'avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
+ recovery_expression: 'max(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
name: 'Device {#SNMPVALUE}: Temperature is above warning threshold'
event_name: 'Device {#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
@@ -1193,8 +1193,8 @@ zabbix_export:
dependencies:
-
name: 'Device {#SNMPVALUE}: Temperature is above critical threshold'
- expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
- recovery_expression: 'max(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
+ expression: 'avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
+ recovery_expression: 'max(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
tags:
-
tag: scope
@@ -1204,9 +1204,9 @@ zabbix_export:
value: performance
-
uuid: f1bbf02af05041ef95ff80ff18fc02a7
- expression: 'avg(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
+ expression: 'avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
- recovery_expression: 'min(/Dell Force S-Series SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
+ recovery_expression: 'min(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
name: 'Device {#SNMPVALUE}: Temperature is too low'
event_name: 'Device {#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
@@ -1265,7 +1265,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 6f02e903dab24bf294015f43e0b52504
- expression: 'last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]))>0'
+ expression: 'last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]))>0'
name: '#{#SNMPVALUE}: Device has been replaced'
event_name: '#{#SNMPVALUE}: Device has been replaced (new serial number received)'
priority: INFO
@@ -1322,7 +1322,7 @@ zabbix_export:
trigger_prototypes:
-
uuid: 66049aa1d7cb45ebac1fe5292c309ba2
- expression: 'last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]))>0'
+ expression: 'last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]))>0'
name: '#{#SNMPVALUE}: Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possible reasons that system has been updated or replaced. Ack to close.'
@@ -1330,7 +1330,7 @@ zabbix_export:
dependencies:
-
name: 'System name has changed'
- expression: 'last(/Dell Force S-Series SNMP/system.name,#1)<>last(/Dell Force S-Series SNMP/system.name,#2) and length(last(/Dell Force S-Series SNMP/system.name))>0'
+ expression: 'last(/Dell Force S-Series by SNMP/system.name,#1)<>last(/Dell Force S-Series by SNMP/system.name,#2) and length(last(/Dell Force S-Series by SNMP/system.name))>0'
tags:
-
tag: scope
@@ -1459,7 +1459,7 @@ zabbix_export:
type: GRAPH_PROTOTYPE
name: graphid
value:
- host: 'Dell Force S-Series SNMP'
+ host: 'Dell Force S-Series by SNMP'
name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
valuemaps:
-
@@ -2411,7 +2411,7 @@ zabbix_export:
triggers:
-
uuid: 4246a064d33f428c8441491402ae8090
- expression: '(last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Dell Force S-Series SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Dell Force S-Series SNMP/system.net.uptime[sysUpTime.0])<10m)'
+ expression: '(last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Dell Force S-Series by SNMP/system.net.uptime[sysUpTime.0])<10m)'
name: 'Host has been restarted'
event_name: '{HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
@@ -2420,7 +2420,7 @@ zabbix_export:
dependencies:
-
name: 'No SNMP data collection'
- expression: 'max(/Dell Force S-Series SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
+ expression: 'max(/Dell Force S-Series by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
tags:
-
tag: scope