diff options
Diffstat (limited to 'templates/net/morningstar/morningstar_prostar_mppt_snmp/README.md')
-rw-r--r-- | templates/net/morningstar/morningstar_prostar_mppt_snmp/README.md | 124 |
1 files changed, 62 insertions, 62 deletions
diff --git a/templates/net/morningstar/morningstar_prostar_mppt_snmp/README.md b/templates/net/morningstar/morningstar_prostar_mppt_snmp/README.md index 382ab7101ed..5865408c7fe 100644 --- a/templates/net/morningstar/morningstar_prostar_mppt_snmp/README.md +++ b/templates/net/morningstar/morningstar_prostar_mppt_snmp/README.md @@ -1,9 +1,9 @@ -# Morningstar ProStar MPPT SNMP +# Morningstar ProStar MPPT by SNMP ## Overview -For Zabbix version: 6.4 and higher +For Zabbix version: 6.4 and higher. ## Setup @@ -77,67 +77,67 @@ There are no template links in this template. |Name|Description|Expression|Severity|Dependencies and additional info| |----|-----------|----|----|----| -|Battery: Device charge in warning state |<p>-</p> |`last(/Morningstar ProStar MPPT SNMP/charge.state[chargeState.0])={$CHARGE.STATE.WARN}` |WARNING |<p>**Depends on**:</p><p>- Battery: Device charge in critical state</p> | -|Battery: Device charge in critical state |<p>-</p> |`last(/Morningstar ProStar MPPT SNMP/charge.state[chargeState.0])={$CHARGE.STATE.CRIT}` |HIGH | | -|Battery: Low battery voltage |<p>-</p> |`max(/Morningstar ProStar MPPT SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.WARN}` |WARNING |<p>**Depends on**:</p><p>- Battery: Critically low battery voltage</p> | -|Battery: Critically low battery voltage |<p>-</p> |`max(/Morningstar ProStar MPPT SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}` |HIGH | | -|Battery: High battery voltage |<p>-</p> |`min(/Morningstar ProStar MPPT SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.WARN}` |WARNING |<p>**Depends on**:</p><p>- Battery: Critically high battery voltage</p> | -|Battery: Critically high battery voltage |<p>-</p> |`min(/Morningstar ProStar MPPT SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}` |HIGH | | -|Load: Device load in warning state |<p>-</p> |`last(/Morningstar ProStar MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.WARN:"lvdWarning"} or last(/Morningstar ProStar MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.WARN:"override"}` |WARNING |<p>**Depends on**:</p><p>- Load: Device load in critical state</p> | -|Load: Device load in critical state |<p>-</p> |`last(/Morningstar ProStar MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar ProStar MPPT SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"fault"}` |HIGH | | -|Status: Device has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/Morningstar ProStar MPPT SNMP/status.hw.uptime)>0 and last(/Morningstar ProStar MPPT SNMP/status.hw.uptime)<10m) or (last(/Morningstar ProStar MPPT SNMP/status.hw.uptime)=0 and last(/Morningstar ProStar MPPT SNMP/status.net.uptime)<10m)` |INFO |<p>Manual close: YES</p> | -|Status: Failed to fetch data |<p>Zabbix has not received data for items for the last 5 minutes.</p> |`nodata(/Morningstar ProStar MPPT SNMP/status.net.uptime,5m)=1` |WARNING |<p>Manual close: YES</p> | -|Status: Device has "overcurrent" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","overcurrent")=2` |HIGH | | -|Status: Device has "mosfetSShorted" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","mosfetSShorted")=2` |HIGH | | -|Status: Device has "software" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","software")=2` |HIGH | | -|Status: Device has "batteryHvd" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","batteryHvd")=2` |HIGH | | -|Status: Device has "arrayHvd" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","arrayHvd")=2` |HIGH | | -|Status: Device has "customSettingsEdit" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","customSettingsEdit")=2` |HIGH | | -|Status: Device has "rtsShorted" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","rtsShorted")=2` |HIGH | | -|Status: Device has "rtsNoLongerValid" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","rtsNoLongerValid")=2` |HIGH | | -|Status: Device has "localTempSensorDamaged" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","localTempSensorDamaged")=2` |HIGH | | -|Status: Device has "batteryLowVoltageDisconnect" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","batteryLowVoltageDisconnect")=2` |HIGH | | -|Status: Device has "slaveTimeout" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","slaveTimeout")=2` |HIGH | | -|Status: Device has "dipSwitchChanged" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.array_faults[arrayFaults.0],#3,"like","dipSwitchChanged")=2` |HIGH | | -|Status: Device has "externalShortCircuit" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","externalShortCircuit")=2` |HIGH | | -|Status: Device has "overcurrent" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","overcurrent")=2` |HIGH | | -|Status: Device has "mosfetShorted" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","mosfetShorted")=2` |HIGH | | -|Status: Device has "software" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","software")=2` |HIGH | | -|Status: Device has "loadHvd" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","loadHvd")=2` |HIGH | | -|Status: Device has "highTempDisconnect" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","highTempDisconnect")=2` |HIGH | | -|Status: Device has "dipSwitchChanged" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","dipSwitchChanged")=2` |HIGH | | -|Status: Device has "customSettingsEdit" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.load_faults[loadFaults.0],#3,"like","customSettingsEdit")=2` |HIGH | | -|Status: Device has "rtsShorted" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","rtsShorted")=2` |WARNING | | -|Status: Device has "rtsDisconnected" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","rtsDisconnected")=2` |WARNING | | -|Status: Device has "heatsinkTempSensorOpen" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorOpen")=2` |WARNING | | -|Status: Device has "heatsinkTempSensorShorted" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorShorted")=2` |WARNING | | -|Status: Device has "heatsinkTempLimit" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempLimit")=2` |WARNING | | -|Status: Device has "inductorTempSensorOpen" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","inductorTempSensorOpen")=2` |WARNING | | -|Status: Device has "inductorTempSensorShorted" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","inductorTempSensorShorted")=2` |WARNING | | -|Status: Device has "inductorTempLimit" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","inductorTempLimit")=2` |WARNING | | -|Status: Device has "currentLimit" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","currentLimit")=2` |WARNING | | -|Status: Device has "currentMeasurementError" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","currentMeasurementError")=2` |WARNING | | -|Status: Device has "batterySenseOutOfRange" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","batterySenseOutOfRange")=2` |WARNING | | -|Status: Device has "batterySenseDisconnected" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","batterySenseDisconnected")=2` |WARNING | | -|Status: Device has "uncalibrated" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","uncalibrated")=2` |WARNING | | -|Status: Device has "tb5v" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","tb5v")=2` |WARNING | | -|Status: Device has "fp10SupplyOutOfRange" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","fp10SupplyOutOfRange")=2` |WARNING | | -|Status: Device has "mosfetOpen" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","mosfetOpen")=2` |WARNING | | -|Status: Device has "arrayCurrentOffset" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","arrayCurrentOffset")=2` |WARNING | | -|Status: Device has "loadCurrentOffset" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","loadCurrentOffset")=2` |WARNING | | -|Status: Device has "p33SupplyOutOfRange" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","p33SupplyOutOfRange")=2` |WARNING | | -|Status: Device has "p12SupplyOutOfRange" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","p12SupplyOutOfRange")=2` |WARNING | | -|Status: Device has "hightInputVoltageLimit" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","hightInputVoltageLimit")=2` |WARNING | | -|Status: Device has "controllerReset" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","controllerReset")=2` |WARNING | | -|Status: Device has "loadLvd" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","loadLvd")=2` |WARNING | | -|Status: Device has "logTimeout" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","logTimeout")=2` |WARNING | | -|Status: Device has "eepromAccessFailure" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT SNMP/status.alarms[alarms.0],#3,"like","eepromAccessFailure")=2` |WARNING | | -|Temperature: Low battery temperature |<p>-</p> |`max(/Morningstar ProStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.WARN}` |WARNING |<p>**Depends on**:</p><p>- Temperature: Critically low battery temperature</p> | -|Temperature: Critically low battery temperature |<p>-</p> |`max(/Morningstar ProStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}` |HIGH | | -|Temperature: High battery temperature |<p>-</p> |`min(/Morningstar ProStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.WARN}` |WARNING |<p>**Depends on**:</p><p>- Temperature: Critically high battery temperature</p> | -|Temperature: Critically high battery temperature |<p>-</p> |`min(/Morningstar ProStar MPPT SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}` |HIGH | | +|Battery: Device charge in warning state |<p>-</p> |`last(/Morningstar ProStar MPPT by SNMP/charge.state[chargeState.0])={$CHARGE.STATE.WARN}` |WARNING |<p>**Depends on**:</p><p>- Battery: Device charge in critical state</p> | +|Battery: Device charge in critical state |<p>-</p> |`last(/Morningstar ProStar MPPT by SNMP/charge.state[chargeState.0])={$CHARGE.STATE.CRIT}` |HIGH | | +|Battery: Low battery voltage |<p>-</p> |`max(/Morningstar ProStar MPPT by SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.WARN}` |WARNING |<p>**Depends on**:</p><p>- Battery: Critically low battery voltage</p> | +|Battery: Critically low battery voltage |<p>-</p> |`max(/Morningstar ProStar MPPT by SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}` |HIGH | | +|Battery: High battery voltage |<p>-</p> |`min(/Morningstar ProStar MPPT by SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.WARN}` |WARNING |<p>**Depends on**:</p><p>- Battery: Critically high battery voltage</p> | +|Battery: Critically high battery voltage |<p>-</p> |`min(/Morningstar ProStar MPPT by SNMP/battery.voltage[batteryTerminalVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}` |HIGH | | +|Load: Device load in warning state |<p>-</p> |`last(/Morningstar ProStar MPPT by SNMP/load.state[loadState.0])={$LOAD.STATE.WARN:"lvdWarning"} or last(/Morningstar ProStar MPPT by SNMP/load.state[loadState.0])={$LOAD.STATE.WARN:"override"}` |WARNING |<p>**Depends on**:</p><p>- Load: Device load in critical state</p> | +|Load: Device load in critical state |<p>-</p> |`last(/Morningstar ProStar MPPT by SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar ProStar MPPT by SNMP/load.state[loadState.0])={$LOAD.STATE.CRIT:"fault"}` |HIGH | | +|Status: Device has been restarted |<p>Uptime is less than 10 minutes.</p> |`(last(/Morningstar ProStar MPPT by SNMP/status.hw.uptime)>0 and last(/Morningstar ProStar MPPT by SNMP/status.hw.uptime)<10m) or (last(/Morningstar ProStar MPPT by SNMP/status.hw.uptime)=0 and last(/Morningstar ProStar MPPT by SNMP/status.net.uptime)<10m)` |INFO |<p>Manual close: YES</p> | +|Status: Failed to fetch data |<p>Zabbix has not received data for items for the last 5 minutes.</p> |`nodata(/Morningstar ProStar MPPT by SNMP/status.net.uptime,5m)=1` |WARNING |<p>Manual close: YES</p> | +|Status: Device has "overcurrent" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","overcurrent")=2` |HIGH | | +|Status: Device has "mosfetSShorted" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","mosfetSShorted")=2` |HIGH | | +|Status: Device has "software" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","software")=2` |HIGH | | +|Status: Device has "batteryHvd" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","batteryHvd")=2` |HIGH | | +|Status: Device has "arrayHvd" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","arrayHvd")=2` |HIGH | | +|Status: Device has "customSettingsEdit" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","customSettingsEdit")=2` |HIGH | | +|Status: Device has "rtsShorted" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","rtsShorted")=2` |HIGH | | +|Status: Device has "rtsNoLongerValid" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","rtsNoLongerValid")=2` |HIGH | | +|Status: Device has "localTempSensorDamaged" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","localTempSensorDamaged")=2` |HIGH | | +|Status: Device has "batteryLowVoltageDisconnect" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","batteryLowVoltageDisconnect")=2` |HIGH | | +|Status: Device has "slaveTimeout" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","slaveTimeout")=2` |HIGH | | +|Status: Device has "dipSwitchChanged" array faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.array_faults[arrayFaults.0],#3,"like","dipSwitchChanged")=2` |HIGH | | +|Status: Device has "externalShortCircuit" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.load_faults[loadFaults.0],#3,"like","externalShortCircuit")=2` |HIGH | | +|Status: Device has "overcurrent" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.load_faults[loadFaults.0],#3,"like","overcurrent")=2` |HIGH | | +|Status: Device has "mosfetShorted" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.load_faults[loadFaults.0],#3,"like","mosfetShorted")=2` |HIGH | | +|Status: Device has "software" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.load_faults[loadFaults.0],#3,"like","software")=2` |HIGH | | +|Status: Device has "loadHvd" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.load_faults[loadFaults.0],#3,"like","loadHvd")=2` |HIGH | | +|Status: Device has "highTempDisconnect" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.load_faults[loadFaults.0],#3,"like","highTempDisconnect")=2` |HIGH | | +|Status: Device has "dipSwitchChanged" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.load_faults[loadFaults.0],#3,"like","dipSwitchChanged")=2` |HIGH | | +|Status: Device has "customSettingsEdit" load faults flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.load_faults[loadFaults.0],#3,"like","customSettingsEdit")=2` |HIGH | | +|Status: Device has "rtsShorted" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","rtsShorted")=2` |WARNING | | +|Status: Device has "rtsDisconnected" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","rtsDisconnected")=2` |WARNING | | +|Status: Device has "heatsinkTempSensorOpen" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorOpen")=2` |WARNING | | +|Status: Device has "heatsinkTempSensorShorted" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorShorted")=2` |WARNING | | +|Status: Device has "heatsinkTempLimit" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempLimit")=2` |WARNING | | +|Status: Device has "inductorTempSensorOpen" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","inductorTempSensorOpen")=2` |WARNING | | +|Status: Device has "inductorTempSensorShorted" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","inductorTempSensorShorted")=2` |WARNING | | +|Status: Device has "inductorTempLimit" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","inductorTempLimit")=2` |WARNING | | +|Status: Device has "currentLimit" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","currentLimit")=2` |WARNING | | +|Status: Device has "currentMeasurementError" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","currentMeasurementError")=2` |WARNING | | +|Status: Device has "batterySenseOutOfRange" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","batterySenseOutOfRange")=2` |WARNING | | +|Status: Device has "batterySenseDisconnected" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","batterySenseDisconnected")=2` |WARNING | | +|Status: Device has "uncalibrated" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","uncalibrated")=2` |WARNING | | +|Status: Device has "tb5v" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","tb5v")=2` |WARNING | | +|Status: Device has "fp10SupplyOutOfRange" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","fp10SupplyOutOfRange")=2` |WARNING | | +|Status: Device has "mosfetOpen" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","mosfetOpen")=2` |WARNING | | +|Status: Device has "arrayCurrentOffset" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","arrayCurrentOffset")=2` |WARNING | | +|Status: Device has "loadCurrentOffset" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","loadCurrentOffset")=2` |WARNING | | +|Status: Device has "p33SupplyOutOfRange" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","p33SupplyOutOfRange")=2` |WARNING | | +|Status: Device has "p12SupplyOutOfRange" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","p12SupplyOutOfRange")=2` |WARNING | | +|Status: Device has "hightInputVoltageLimit" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","hightInputVoltageLimit")=2` |WARNING | | +|Status: Device has "controllerReset" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","controllerReset")=2` |WARNING | | +|Status: Device has "loadLvd" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","loadLvd")=2` |WARNING | | +|Status: Device has "logTimeout" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","logTimeout")=2` |WARNING | | +|Status: Device has "eepromAccessFailure" alarm flag |<p>-</p> |`count(/Morningstar ProStar MPPT by SNMP/status.alarms[alarms.0],#3,"like","eepromAccessFailure")=2` |WARNING | | +|Temperature: Low battery temperature |<p>-</p> |`max(/Morningstar ProStar MPPT by SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.WARN}` |WARNING |<p>**Depends on**:</p><p>- Temperature: Critically low battery temperature</p> | +|Temperature: Critically low battery temperature |<p>-</p> |`max(/Morningstar ProStar MPPT by SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}` |HIGH | | +|Temperature: High battery temperature |<p>-</p> |`min(/Morningstar ProStar MPPT by SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.WARN}` |WARNING |<p>**Depends on**:</p><p>- Temperature: Critically high battery temperature</p> | +|Temperature: Critically high battery temperature |<p>-</p> |`min(/Morningstar ProStar MPPT by SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}` |HIGH | | ## Feedback -Please report any issues with the template at https://support.zabbix.com +Please report any issues with the template at https://support.zabbix.com. |